| 1 | L1₹45.2 LAccepted-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹46.3 L+₹27,495.90 (0.60%)Rejected-Finance 6146 HIRA CHOWK SIRKI BAZAR BATHINDA PB 151005 | BATHINDA | PUNJAB | 151005 | L2 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 3 | L3₹53.5 L+₹7.6 L (16.5%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 4 | L4₹54.4 L+₹8.4 L (18.3%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L4 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KOTA
DADWARA KOTA RAJASTHAN 324002
SPL REPAIR TO BLOCK NOS P-303 (01 TO 04) AND P-315 01 TO 04 JCO MD ACCNS AT GTC LINE AND CERTAIN REVENUE AND MINOR WORKS FOR CERTAIN UNITS AT MIL STN KOTA
2024_MES_663535_1
8867E8
Open Tender
Civil Works
Item Rate
183 days
GE KOTA
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE KOTA
₹95,000
Yes
26 Oct 2024
2 Jul 2024
12 Sept 2024
2 Jul 2024
4 Sept 2024
16 Jul 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid matte finish ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid matte finish ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm fixed on vertical surfaces as scarting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.complete all as specified and as directed.
M & L for 50 mm thick dressed sand stone slab for manhole cover jointed and pointed in CM (1:4) complete all as specified and as directed.
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 15 mm thick cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 18 to 20 mm thick over and including cement screed bed of 15 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 18 to 20 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on and including backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and as directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
Taking down existing treatment of any description such as PCC padding, lime concrete, mud phuska etc. and any numbers of layers upto any thickness from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed.
M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges complete all as specified and as directed.
Material & labour for rendering 20 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction finished even and fair complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only)
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) mixed with water proofing compound as per manufacturer instructions in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and fair complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed.
Preparation of newly plastered surfaces on ceilings and applying three coats of white wash complete all as specified and as directed.
M & L for preparation of old surface of wall and applying one coat of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying two coats of white wash complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed.
Taking down existing door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
Blank
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
S & F 35 mm thick, timber species of super group or group I or group II and durability class II as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (multi panels) with lock rail and panel of 9 mm thick, BWR grade, plywood conforming to IS 303 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned as per IS 1141 and chemically pressure treated as per IS 401.
M & L for 35 mm thick Iind class hard wood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (b) complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles & rails with 5 mm X 15 mm PVC sheet beading and decorative PVC beading of 10 mm X 10 mm (90⁰) used instead of exposed portion of PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed.
S & F 125 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F butt hinges, extruded aluminium alloy with galvanised mild steel wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 100B21 as per IS 205: 1992 complete all as specified and as directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 4 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, dia of bolt 12 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 100 mm long, dia of bolt 10 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F extruded aluminium alloy handle, fabricated type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 150 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 40 & 45 mm thickness of door shutter, fixed in floor complete all as specified and as directed.
S & F in renewal of floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 150 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 40 & 45 mm thickness of door shutter, fixed in floor complete all as specified and as directed.
S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
S & F in renewal of prelaminated particle board (decorative lamination on one side and other side balancing lamination), 18/19 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in tabletops, counter, furniture tops, etc. complete all as specified and as directed.
M & L for teak wood lipping, 6 mm thick for 12 mm thick, block board, veneered particle board, prelaminated particle board fixed with nails complete all as specified and as directed.
S & F mild steel continuous hinge, 40 mm nominal size, 1 mm thick, type IV as per IS 3818: 1992, bright finish and fixed to cupboard shutter complete all as specified and as directed.
S & F aluminium alloy hasps and staples, type -1, safety type, size 125 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 including fixing with screws complete all as specified and as directed.
S & F extruded aluminium alloy handle, fabricated type, 75 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F in renewal of stainless steel curtain rod made out of stainless steel sheet of grade X 02Cr19Ni1O (304 S2), surface finish No. 4 as per IS 6911: 2017, 25 mm dia including fixing to brackets and holders etc. complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Blank
S & F in renewal of Bib taps 15mm dia, chromium plated, long body, with CP flange all as per fixed in repairs complete all as specified and as directed. Make :- CERA cat part No G 1017152 /Jaquar cat pat no VGP-81037/ Hindware cat part No F 740011 or techno commercially equivalent makes specified in PS.
S & F in renewal of 15mm bore angle valve chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed with necessary fitting complete all as specified and directed. Make :- CERA cat part No G1017211 / Hindware cat part no F 740006 / Johnson cat part no JT 1643A or techno commercially equivalent Make specified in PS
S & F in renewal of 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F pillar taps, 15mm dia, long body/swan neck, fancy type suitable for fixing to wash basin screwed for iron pipe and fixed with necessary fittings and including PVC connection complete all as specified and as directed. Make :- CERA Cat Part No F1003103 / Jaquar cat Part No COP -021PM/ Hindware Cat Part No F 740002 or techno commercially equivalent makes specified in PS.
S & F in renewal of brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S & F in renewal of towel rail 600mm long of CP fixed with screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed. Make :- CERA Cat No.F5013104CH/Jaquar cat part No ACN-1111 SM/ Hindware cat part No F 450024 or techno commercially equivalent makes specified in PS.
S & F in renewal of vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed.
S & F in renewal of PVC low/high level flushing cistern white 10 liters capacity including PVC inlet pipe with brass check nuts low level full both sides along with PVC flush pipe 32 mm dia jointed to WC and handle including brackets fixed in repairs complete all as specified and as directed. Note:- Rate includes removing existing flushing system of CI or any other quality including brackets.
S & F 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant complete all as specified and as directed.
M & L in renewal of PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in renewal of wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F in renewal of Soap dish any type, fixed to plugs with chromium plated brass screws omplete all as specified and as directed. Make :- CERA Cat Part No F5013106CH/ Jaquar cat part No AKP 35731P/ Hindware cat part No F 450022 or equivalent makes as specified in PS.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed.
S & F rotational moulded polyethylene tripple layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed.
S & F in renewal of sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F in renewal of Kitchen stainless steel plate rack of size 30" X 36" X 10" awith partition for small/ large plates fabricated out of 24 gauge stainless steel sheet including necessary fixing / fittings & making good the existing surfaces complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store or taken on schedule of credit (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and as directed.
S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed.
S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed.
S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
S & F UPVC branch piece, Wye (45⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and as directed.
Supply and fix in renewal of PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm complete all as specified and as directed.
Providing and fixing galvanised steel holder bat clamps of approved design to 100 mm dia/ bore rain water pipe/ soil waste pipe embedded in and including cement concrete blocks 100 mm X 100 mm X 100 mm of Nominal Mix (M15) using 20 mm nominal size graded crushed stone aggregate and cost of cutting holes and making good at any floor complete all as specified and as directed.
Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating over areas exceeding 1.5 m but not exceeding 3 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius laid dry in retaining walls, abutments, soakage well and similar works, complete all as specified and as directed.
Material and labour for plastering 12 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and as directed.
S & F cast iron, centrifugally cast, socket and spigot, nominal dia 50 mm soil, waste and vent pipe as per IS 3989: 2009 in any length with cement joints, laid in trenches or in floors complete all as specified and as directed.
S & F cast iron, centrifugally cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 3989: 2009 in any length with cement joints, laid in trenches or in floors complete all as specified and as directed.
S & F cast iron vent cowl for 100 mm bore pipe complete all as specified and as directed.
M & L for loose filling with broken stone or boulder aggregates of gauge 40 to 80 mm in soakage pits, soakage wells, on open space etc. complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
M & L for cement concrete in surface channels and drains in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supplying and laying reinforced concrete pipes with collars, 150 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed.
M & L for concrete bed to drain pipes of internal diameter 150 mm laid in trenches in cement concrete M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated (profile) steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category C3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall cladding fixed with self drilling screws and washers as specified including end and side lap, necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Taking down carefully without point wiring by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in renewal of call bell suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of casing/capping shall be measured and paid as one unit length.
S & F LED tube fitting 4 feet 20 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP021604C0001 or equivalent technocommercially equivalent make as specified in PS.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP011608C0001 or equivalent technocommercially equivalent make as specified in PS.
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 100 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F in renewal of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with & including MCB SP 20 Amps 240 volts complete all as specified and as directed.
Supply and fix in renewal of Exhaust fans 300 mm sweep, metal body, double ball bearings heavy duty motor, air delivery 1850 m³/min, rated speed of 1400 revolution per minute, 4 blades, power consumption 70 W, rated voltage 200 V to 240 V, rated frequency 50 Hz complete all as specified and as directed.
Supply and fix in renewal of exhaust fan made of sturdy engineering plastic (having excellent impact and abrasion resistance, light weight and resistance to colour change), complete with louvers shutter, voltage 230V, 50 Hz, speed 1200 rpm, 250 mm sweep size, 5 number of blades, air delivery 860 cubic metre per hour, copper winding complete all as specified and as directed.
S & F in renewal of ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, 1350 rpm, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, including capacitor to ensure power factor more than 0.9, with all accessories complete all as specified and as directed.
Supplying, installing, testing & commissioning, Storage Geyser, five star rated, 25 litres Capacity, ABS plastic body material, stainless steel inner tank material, shock proof, auto cut, on-off indicator, thermoplastic body, corrosion free with safety valve, fusible plug, thermal cut out including fixing by grouting and fastener including taking out old unserviceable geyser complete all as specified and as directed.
Supply, installation, commissioning and testing in renewal of outdoor type, LT panel board of size 600 mm X 900 mm X 350 mm, CPRI approved factory made, powder coated suitable for 3 phase 4 wire 415 V, 50 Hz and provided with suitable 'U' type gasket to make it dust/vermin proof & general construction confirming to IS: 8623/93, floor block mounting type made out of 3.15 mm thick CRCA sheet with using 45 mm X 45 mm X 5 mm angle iron frame, factory fabricated duly compartmentalized for each control gear with front & back openable, lockable/ openable by keys from both sides louvers & air vent gasket for natural flow of air and to accommodate incoming/ outgoing MCCBs and TPN aluminium bus bar 400 Amp and alike complete including fixing of undermentioned MCBs and alike as under:- (a) Ammeter size 96 mm X 96 mm, flush mounted digital type, three phase of class 1.0- 01 No. (b) LED Indicator lamp RYB- 01 No (c) Voltmeter size 96 mm X 96 mm, flush mounted digital type, three phase, class 1.0- 01 No. (d) Aluminum bus bar 400 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mm x 50mm) conical type-01 Set. (Note: The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)
M & L in renewal of earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
M & L in renewal of earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
B B BUILDERS (BID ID -3070765)
L P Singh and Co. (BID ID -3069963)
Aditya Enterprises (BID ID -3070137)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .