| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹42.7 L+₹64,270.10 (1.53%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹42.8 L+₹75,146.90 (1.79%)Rejected-AOC | L3 | Rejected-AOC ok |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
2 Aug 2022, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
ADDN/ALTN TO BLDG NO P-17 OF CADET HOSPITAL AT RIMC DEHRADUN
2022_MES_535963_1
9737/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹87,200
Yes
27 Sept 2022
5 Jul 2022
4 Aug 2022
5 Jul 2022
2 Aug 2022
19 Jul 2022
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed.
M&L for plain Cement concrete 1:4:8 Type D-2 (40 mm graded crushed stone aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
M & L for use and waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough flat finished surfaces of concrete complete all as specified and directed.
M & L for use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough flat finished surfaces of concrete complete all as specified and directed.
M & L for use and waste for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough square, rectangular or polygonal finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete M-25 (design mix) (20 mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete M-25 (design mix) (20 mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Reinforced cement concrete M-25 (design mix) (20 mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismantling of Brickwork or stone/bou-lder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed.
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M & L for providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or Electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips or 3mm dia GI wire spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm, all 'T'' sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement 1:6 complete all as specified and directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M & L for returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
M & L for removing excavated soil n. exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M & L for rendering 15 mm thick on surface other than fair faces of brick work or concrete surface in cement mortar 1:6, surface finished even and fair (without using extra cement) complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:4, surface finished even and fair (without using extra cement) complete all as specified and directed.
M&L for preparation of surface of wall and applying interior grade wall care putty 1 to 2 mm thick to make the surface smooth over and incl. two coat of oil bound distemper over a coat of primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of wall and applying exterior grade wall care putty 1 to 2 mm thick to make the surface smooth over and incl. finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls (plastered) by brooming down with coir wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and finally clean with sand paper and incl. two coats oil bound distemper any tint on already prepared surfaces of walls over a coat of primer all as directed by Engr-in-Charge.
M&L for preparation of old plastered surface of wall and applying two coat of exterior emulsion paint over a coat of primer complete all as specified and directed.
Taking down shutter of any description, n. exc. 1 Sqm each complete all as specified and directed.
Taking down shutter of any description, exc. 1 Sqm but n. exc. 2 Sqm each complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete.
S & F 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
Supply and fix in repair aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty shutter to be partly glaze with 5mm thick tined coloured glass in upper panel and partly paneled with 12mm thick both side laminated particle board in lower panel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed at site. Chowkhat Frame:- 101.60x44.45x1.60mm, Shutter vertical style :- 85x44.45x1.56mm, shutter middle Rail :- 83.50x44.45x1.54mm, Shutter Top Rail and bottom Rail :- 114.30x44.45x1.55mm
M&L for powder coated Aluminium partition (Fixed) made out of aluminium powder coated section 83 x 44.45 x 2.00 mm including 5 mm thick glass/ACP Sheet complete with rubber packing/aluminum beading etc including dismantling of existing structure complete all as specified and directed
Material and labour for aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one nos wire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mm, Shutter inner lock size 37.50x15x1.60 mm, Shutter side (Handle) size 37.50x15x1.36 mm, Chowkhat bottom size : 50.30x26x1.20mm, Chowkhat top & sides size: 50.30x26x1.00mm
S&F pre laminated Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side pre lam PVC sheet and edges will be painted to match with pre lam sheet, PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made pre laminated solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded both side pre lam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side pre lam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of both side pre lam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing complete all as specified and directed.
S&F Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 200 mm long, solid in one piece powder coated mild steel bright finish barrel tower bolts 10mm dia shoot complete all as specified and directed.
S&F 150 mm long, solid in one piece powder coated mild steel bright finish barrel tower bolts 10mm dia shoot complete all as specified and directed.
S&F 150mm size solid in one piece powder coated mild steel bright finish handles, D type and fixed with stainless steel screws complete all as specified and directed.
S&F 100 mm size powder coated mild steel butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and directed.
S&F 300mm long powder coated mild steel sliding door bolts, hasp and staple type with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
M&L for preparation of new steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wooden surface 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for forming embankments including raising (or lowering) earth filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 25mm thick cement concrete in 1:2:4 type B-0 ( 12.50 mm graded aggregate) complete all as specified and directed.
M&L for 100mm thick cement concrete 1:4:8 type D2 (40mm graded stone aggregate) complete all as specified and directed.
M & L for non Skid coloured ceramic tiles 7-8 mm thick(Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match of coloured tiles over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M & L for vitrified ceramic dark shade tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
All as per item No 56.00 here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M & L for ceramic glazed coloured/ design tile in vertical surfaces (300x 450mm) x 7mm thick such as dado and skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified.
S&F 15mm bore pipe medium grade galvanised with all fittings & fixed to wall and ceiling or laid in floor complete all as specified and directed.
All as per item No 59 above but 20mm dia.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts) and trap including connection to drain (outgoing pipe) & to flushing pipe, anti syphonage pipe, including health faucet etc. complete all as specified and directed.
S&F in repair 15mm bore chromium plated fancy type bib tap of cast copper alloy with crutch of butterfly handle, screwed in iron pipe complete all as specified and directed.
S&F in repair 15mm chromium plated fancy type, stop valves/ angle valve cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends fixed, complete all as specified and directed.
S&F in repair 15mm nominal internal bore PVC connection 450mm long with two brass nuts and PVC washer complete all as specified and directed.
S&F in repair 10 ltr capacity PVC low level flushing cistern including PVC syphon and float valve with PVC long band for out let connection of cistern with WC complete fixing the cistern with wall in pressured connecting with WC complete all as specified and directed.
S&F in repair vitreous china washbasin, white flat back, size 580x450mm excluding taps, waste pipe chain and plug and porcelain but including brackets complete all as specified and directed.
S&F 15mm brass chromium plated wall mixer complete all as specified and directed.
S&F 15mm brass CP central hole basin mixer fancy type complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with shower arm complete all as specified and directed.
S&F 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20 mm brass ball valve complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 type C-1 as in plinth protection, finished even and fair complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring, fixed to wall including dismantling of old pipes complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring, fixed to wall including dismantling of old pipes complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring, laid in trenches or in floors including dismantling of old pipes complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring, laid in trenches or in floors including dismantling of old pipes complete all as specified and directed.
S & F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S & F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
M & L 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
M & L for surface dressing in soft/loose soil n.exc (not exceeding) 15cm deep and getting out complete all as specified and directed.
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing complete all as specified and directed.
M&L for point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multi stranded copper conductor single core FRLS cable drawn through and including non metallic rigid PVC concealed/ conduit on wall as required for One light/bell point controlled by one-one way switch complete all as specified and directed.
All as per item No 82 above but One bell point controlled by one-one way switch.
All as per item No 82 above but wiring for One ceiling fan / exhaust fan.
All as per item No 82 above but wiring for One three pin 5 Amp socket on same board with other switches.
All as per item No 82 above but wiring for One three pin 5 Amp socket on independent board.
All as per item No 82 above with 4 Sqmm wire/cable for one 3 Pin 15 amp socket on independent board
S & F Modular Fan Regulator electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed.
S&F switch modular 6 Amps 230 Volts one way switch complete all as specified and directed.
S&F Socket modular 6 Amps AC 230 Volts 2/3 pin combined 2 modular type complete all as specified and as directed
S&F Socket 6A/16 Amps-2/3 pin combined AC 230 Volts modular type complete all as specified and as directed.
S&F Switch modular type AC 230 volts 16 Amps one way complete all as specified & as directed.
S&F modular bell push 6 Amp one module one way complete all as specified and directed.
S&F GI sunken box with flush metal GI box 1 module suitable for modular switches incl plastering, making good disturbed surfaces of wall, painting to match the existing finishes complete all as specified and directed.
All as per item no 94 here in above but 2 module.
All as per item no 94 here in above but 3 module.
All as per item no 94 hrer in above but 4 module.
All as per item no 94 here in above but 6 module.
All as per item no 94 here in above but 8 module.
All as per item no 94 here in above but 12 module.
S&F combind cover plate white 1 module suitable for modular switches complete all as specified and directed.
All as per item no 101 here in above but 2 module
All as per item no 101 here in above but 3 module
All as per item no 101 here in above but 4 module
All as per item no 101 here in above but 6 module
All as per item no 101 here in above but 8 module
All as per item no 101 here in above but 12 module.
S&F ceiling rose surface Bakelite 3 terminals of size 65x25mm complete all as specified and directed
S&F Calling Bell single phase 230 Volt Ding Dong complete all as specified and directed.
S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F BLDC Ceiling Fan complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , complete connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (As per site requirement) and necessary nuts and bolts complete all as specified and directed.
S&F Exhaust fan 150 mm PVC body made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
All as per item no 112 here in above but exhaust metallic type fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed
S&F Wall fans 230 volts single phase oscillating 400 mm sweep complete all as specified and directed
S&F Mirror light decorative compact luminaries with decorative ends caps 9/10 Watt or higher LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make Philips BN 021 LED10S -6500 PSU GR S1 /Havells Cat No ENDURALINEARNEOBS10WLED840SPCWH / CG LCL-07-CDL
S&F Bulk head luminaire with opal diffuser with and including retrofit LED lamp 10 watts complete all as specified and directed. Make : CG cat LBHP-10-CDL/Philips WT140W LED7S CW PSU S1 PC/Havells ENDURA RUGBYNEO N /Mepro cat no BCL 23 Plain
S&F LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 4000K/6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make:Wipro Cat part No LL20-281-XXX-65AL1/ Philips cat part No BN021C LED20S PSU CWGR S2/Havells Cat No ENDURA LINEARNEOBS20W LED865SPCWH.
S&F LED down lighter concealed ceiling light 12W Sky Spot COB (WW) complete all as specified and directed. Note:- Test certificate shall be submitted by the contractor.
S&F LED down lighter concealed ceiling light 36/30 Watt White light fully diffused recessed mounted 2'X2' LED Troffer with micro prismatic diffuser suitable for indoor spaces. complete all as specified and directed. Note:- Test certificate shall be submitted by the contractor.
S&F Electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc ,AC single phase 230/ 240 Vot and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
S&F TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper bus bar for each phase with two neutral bar & two earthbar and cable ties for cable management including mounting arrangement for DPX3 MCCB 125 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed.
S&F MCCB 3 Pole 125 Amp, 25KA thermal magnetic complete all as specified and directed.
S & F sheet metal enclosure TPN for DB's when MCB's to be used 4 way with 200 amps bus bar and double door complete all as specified and directed.
S & F sheet metal enclosure SPN for DB's when MCB's to be used 12 way with 200 amps bus bar and double door complete all as specified and directed.
All as per item no 124 here in above but DB' 8 way.
All as per item no 124 here in above but DB 4 way.
S&F metal clad single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 Amp 240Volt complete all as specified and directed.
S&F MCB TPN 63 Amps 10 kA, 430 Volt complete all as specified and directed.
S&F MCB SPN 240 Volt 10 KA 6 to 40 Amp 'C' series conforming to IS complete all as specified & directed.
S&F MCB SP(single pole) 240 volt, 10 KA, 6-40 Amp, 'C' series confirming to IS complete all as specified and directed.
M&L in replacement for sub main wiring with 3 runs (P+N+Earth continuity conductor) of 2.5 Sqmm single core, PVC insulated, unsheathed, multi stranded copper conductor FRLS cable 1100 volts grade recommended colour code ,drawn through and including concealed PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting all wires with suitable size thimble complete all as specified and directed. Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 131 herein above but sub main wiring with 4 Sqmm nominal area copper conductor.
All as per item No 131 herein above but sub main wiring with 6 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit.
All as per item No 131 here-in-above but sub main wiring with 6 runs(3 run for Phase, 1 run for neutral & 2 run for earth with approved colour) of 10 Sqmm complete all as specified and directed. Note:-6 runs of 10 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ Lt panel etc. and testing on completion, complete all as specified & directed.
All as per item No 135 here-in-above but , using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and as directed.
Supply, laying, connecting and testing in replacement of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 95 Sqmm 3.5 core 1100 volt including all necessary connection accessories like thimble, cable glands, nuts & bolts complete all as specified and directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness all complete all as specified and directed. Note :- Only punned down sand thickness 18CM shall be measured and paid.
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and directed.
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for GI tubing medium grade (ISI marked) 50mm dia with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc complete all as specified and directed.
Supply install Testing & Commissioning of thermoplastic Polycarbonate IP 65 Distribution Board in accordance with IEC 60 529 (Dust Proof, Water Proof & Weatherproof) Thermoplastic Polycarbonate DB of Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing, UV Resistant, Silica and Halogen Free recyclable material. Type tasted as per IEC 61 439-1. Total Insulated with System Voltage 415V AC, 50Hz, and 5 wires complete all as specified and directed.
(a) The board/panel should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 ( 5 Joule) in accordance with IEC 62262.
(b) The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT OF DEGREE OF INGRESS PROTECTION IP 65/ IP54 IN ACCORDANCE WITH IEC 60529.
(c) The gasket should be internally embedded made of polyurethane.
(d) The manufacturer of board / panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 61439-
The CPRI report shall have mention of following tests performed and passed out satisfactorily:
1. Temperature Rise. 2. Dielectric Properties. 3. Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. 4. Effectiveness of Protective Circuits. 5. Clearance & Creepage Distance. 6. Mechanical Operation
• For the assembly of Power switch gear and control gear assemblies (PSC) up to 630A in accordance with IEC 61439 Part1 & 2.
• The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer.
• Guarantee and warrantee certificates will be accepted only from original manufacturer.
• Routine test certificate should be provided along with panel board. The certificate should be from original manufacturer or some panel builder authorized by original manufacturer.
• As standard mail bus bar system EMC-complaint, with N/PEN conductor in the area of phase conductors and with the same current carrying capacity as the phase conductors.
• The panel should passed glow wire test 960oC in accordance with 60695-2-11[ flame retardant and self-extinguishing
• Cable entry via metric knockouts in all box walls via flanges with metric knockouts or elastic membranes or cable inserts with up to 74mm cable diameter.
• Facility for lead sealing and locking.
Comprising of the following.
Incomer :–
(i) 250A 4P On load Change over switch - 1 Nos. (ii) MCCB – 1No 250A 4P MCCB – 1Nos
(iii) RYB indication lamps – 1Set (iv) Digital type multifunction meter – 1 Set Copper Bus bar rated for 400A
Outgoings.
(i) 63 A 4P MCCBs – 5 Nos (ii) Floor mounting type with canopy.
UNOQ Private Limied
V K Constructive Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .