RequiredExperience with Government
RequiredOEM Authorization Certificate Bid to RA enabled Yes Potable Water Purification System Reverse Osmosis Or UV Based ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certification for the product CE CE
RequiredNSF Certification number and date - * Manufacturers Quality System ISO 9001:2015 ISO 9001:2015 1/6 Certifications Manufacturers Environment Management System Certifications ISO 14001:2004 ISO 14001:2004 Manufacturers Health and Safety Management System Certifications ISO 18001:2007 ISO 18001:2007 Performance Parameters Maximum Input Water TDS allowed to the system 1000 1000 Type of water purification technology UV RO+UV+UF
RequiredUV Aavailability of sediment and activated carbon filter Yes * Operation Fully automatic with auto cut off Fully automatic with auto cut off Ultraviolet (UV) LAMP Yes Yes Conformity to Standard for Ultraviolet system IS 14724 (latest) for water purification system with Ultraviolet disinfection IS 14724 (latest) for water purification system with Ultraviolet disinfection "Ultra Voilet (UV) Lamp power in watts (Hint put zero in case UV is not available)" 40 * Recovery at 27 degree Centigrade 90-100 90-100 Output Water Conforming standard IS 10500 (latest) * Filtration Capacity in liter/hour 100 100 Provision of Arsenic removal No Yes
RequiredNo Provision of Floride removal No Yes
RequiredNo Provision of Chloride removal No Yes
RequiredNo Alkaline filter No Yes
RequiredNo Storage tank Inbuilt Inbuilt
RequiredNot available Type of out put water Storage Tank Stainless Steel Stainless Steel Storage Tank 50ltr 8ltr
Required10ltr
Required12ltr
Required16ltr
Required2/6 Capacity (storage tank external for higher capacity if required to be arranged by buyer) 25ltr
Required50ltr
RequiredStorage tank to be arranged by buyer
RequiredNA Minimum inlet pressure 0.3 KG/CM2 0.3 KG/CM2 Maximum inlet pressure 3.5 KG/CM2 * Maximum inlet temperature 35 DEGREE 35 DEGREE
Required40 DEGREE Digital display No Yes
RequiredNo Real time TDS display No Yes
RequiredNo Real time pH Display No Yes
RequiredNo High pressure pump No Yes
RequiredNo Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes Micron Filter Yes Yes Total Dissolved Solids Removal Percentage from RO Membrane NA for UV only NA for UV only Particulate Filter Porosity 5 micron 5 micron Pressure vessel Sand Filter No Yes
RequiredNo Pressure vessel carbon Filter No Yes
RequiredNo Pressure Vessel Dual Media Filter No Yes
RequiredNo Membrane Housing No Yes
RequiredNo Body of filter ABS Food grade ABS Food grade Auto cut Yes Yes Number of candles 4 2
Required3
Required4
Required5
Required6 or more Power supply 230 Volt single phase 230 Volt single phase Installation Type Floor Mounted Wall mounted
RequiredUnder sink
RequiredFloor Mounted
RequiredFloor Mounted and Enclosed Miscellaneous Parameters Warranty in years including replacement of filters Sediment & carbon twice a year) 1 1 3/6 Warranty in years free replacement of machine NA 1
Required2
Required3
RequiredNA Antiscalant- where silica is up to 10 ppm/where Mica is up to 100 ppm No No Availabilty of type test Test REPORT for Filtering Size of micron Particles No Yes
RequiredNo TYPE Test certificate No and date for Filtering Size of micron Particles - * Name and Address of laboratory which conducted Test for Filtering Size of micron Particles: - * Availability of type Test Report on Microbial Efficacy from Govt/NABL/ilac Lab - * Type Test certificate No and date for Microbial Efficacy - * Name of the lab - * Availability of test report from Govt/NABL/ilac Lab (Design Evalution Report as per IS:14724 Yes Yes Test certificate No and date - * Name and Address of laboratory which conducted Test - * Availability of test report from Govt/NABL/ilac Lab regarding water quality as per IS:10500 Yes * Type Test certificate No and date - * Name and Address of laboratory which conducted type Test regarding water quality - * 4/6 Copies of certifications and reports to be given to buyer at time of supplies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Availability of toll free centers for customer support Yes Yes Installation and Commissioning inclusive in the scope of Supply* Yes Yes Availability of NABL Accredited Laboratory Facility with OEM Yes Yes Name and Address of NABL Accredited lab with OEM
RequiredIf Not available put NA - * Inlet Pipe & Fitting from raw water scorces to water purification system Not applicable Not applicable Pipe & Fitting from Out let to purified water tank To be arranged by buyer/consignee To be arranged by seller (upto 15ft)
RequiredTo be arranged by buyer consignee
RequiredNot applicable Electrical fitting and plug points To be arranged by buyer/consignee * Scope Civil Work if any required during installation All Civil work shall be responsibility of buyer * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents