Loading…
Loading…
Tender ID
Tender Value
₹25 L
EMD Value
₹20,000
Closing Date
24 Mar 2026, 6:00 pmClosed
executive engineer kadodara division
Tender for work of laying, testing and commissioning of 11/22 KV underground & Overhead XLPE cable under various scheme At Kadodara Ind Sub division ( Tantithaiya SS ) under jurisdiction of Kadodara Division of Surat Rural Circle.
286394
KAD/O&M/EXP/N-Procure/2026/03/No.222 date. 07-03-2026 SR. NO.04
Open
Electrical
Works
Surat
3 documents required · 3 mandatory
₹1,180
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹20,000
14 Mar 2026
14 Mar 2026
14 Mar 2026
24 Mar 2026
14 Mar 2026
Tender for work of laying, testing and commissioning of 11/22 KV underground & Overhead XLPE cable under various scheme At Kadodara Ind Sub
division ( Tantithaiya SS ) under jurisdiction of Kadodara Division of Surat Rural Circle.
Sr. No. Item Code Item Unit Rate for
Labour charge for excavation of cable trench of 400mm width x 1200mm depth, in any
140 9925000001 type of soil for laying of cable of size up to 240 mm2 (For additional cable 200 mm Meter
additional width shall be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 600mm width x 1200mm depth, in any
141 9925000002 type of soil for laying of cable of size up to 240 mm2 (For additional cable 200 mm Meter
additional width shall be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x 1500mm depth, in any
142 9925000003 type of soil for laying of cable of size up to 240 mm2 (For additional cable 200 mm Meter
additional width shall be considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to 240 mm2 & preparation
of sand layer 100mm thick, in the cable trench & covering the cable with 150 mm dia
(Inner), thickness 25 mm, 1.0 meter long RCC half round muffs and providing and fixing
143 9925000004 of 4inch width yellow colour polyethylene tape with printing "CAUTION ELECTRIC CABLE Meter
BELOW" at 0.75 m depth from ground surface after laying cable in trench. This will provide
indication that electric cable is passing underground so as to protect cable from mechnical
injuries, refilling the same, as per Instruction of Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger machine without damage to surface
road at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe confirms to IS 4984- 1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of size up to 240 mm2 in HDPE pipe, as
144 9925000005 per Site Condition (excluding cost of pipe). The detail map obtained from HDD machine Meter
and excell sheet(hard and soft copy) indicating the respective depth and distance from
adjacent landmark for each segment for HDD is must required to be submitted. HDD to be
carried out at depth 1.5 mtrs to 2.0 mtrs as per site conditions and as per instruction of
Labour charge for horizontal drilling manually without damage to surface road at max
2.0 mtrs depth & putting of 6.11 kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site
Condition (excluding cost of pipe). The detail map and excell sheet(hard and soft copy)
indicating the respective depth and distance from adjacent landmark for each segment of
cable to be submitted. Drilling to be carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as
per site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm thickness
146 9925000007 H.D.P.E. pipe confirms to IS 4984 and BIS certification for laying of underground 11KV / Meter
22KV XLPE cable up to 240 mm2 size.
Labour work for RCC concreting on disputed location and repairing of damage portion of
147 9925000008 road crossing for the work carried out for roads crossing as well as concreting & muffing CMT
of ploes including all materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width x 150 mm thick x
mm height embedded in earth at least 300 mm below & 350 mm above ground level
respectively at distance approx 50 meters along the length of cable. The RCC concreting
(1:2:4)(all necessary maeterials will be in bidder's scope) of route marker is to be carried
out 300 mm width x 150 mm thick x 300 mm below ground level as per instruction of
EIC. The route marker should be with name of company with approved yellow colour-
DGVCL. The distance from marker to cable and cable depth with feeder name etc., marked
with arrow sign is to be painted on it.The route marker is to be fixed at location near to any
fixed permanent location (not necessary to fix exact on top of cable) as per instruction of
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with cable
connection arrangement along with fitting of necessary fabrication for 11KV cable including
excavation of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable connection
arrangement along with fitting ofnecessary fabrication for 11KV/22 KV cable including
excavation of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with cable connection
arrangement along with fitting of necessary fabrication for 11KV cable including excavation
of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of
Erection of Single pole structure using 8.0 Mtr PSC pole with cable connection
arrangement along with fitting ofnecessary fabrication for 11KV/22 KV cable including
excavation of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to 240 mm2 on DP
153 9925000014 Structure with fixing of 02 Nos polymer cleats on top and middle part.Polymer cleats, Per Job
nut bolts etc. fixing material to be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984 and BIS certification on the erected DP structure
for the mechanical protection of cable by inserting the cable inside HDPE pipe. The HDPE
pipe shall be erected in such a way that 300mm shall be below the ground level and the
rest 2700 mm shall be supported on the DP Structure with 01 No Polymer cleat.All
materials including polymer cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI pipe with pit to be
filled with salt & coke and construction of chamber as per DGVCL Drg. No. dg /100 for DP
and cable. The earthing pit should be joined with cable by G.I. strip of size 1” width &
mm thick. All material GI pipe, Coke, Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations (outdoor) for upto 11kV 3C x
185 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for upto 22 kV
3C x 185 mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations (indoor) for upto 11kV 3C x
mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for upto 22 kV
3C x 185 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for upto 11kV 3C x
185 mm2 size XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for upto 22kV 3C x
mm2 size XLPE cable as per DGVCL technical specification
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep joint pits
for installation of 11kV / 22kV Straight through joints as per instruction of engineer-in-
charge & covering the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long
RCC half round muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable after
removal of semi conducting layer and applying of PVC heat shrinkable anti- tracking core
insulating tubing (1.1KV), on both end terminal using Aluminium long barrel heavy duty up
163 9925000024 to 240 sq mm lugs, Aluminium bus connector. Taping with PG- clamp for bus conductor as No.
per drawing and as per instruction of EIC. The Alluminium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating tapes.(11KV/22KV XLPE cable will be in scope of
DGVCL while all other materials will be in bidder's scope)
Testing of cable at various points and commissioning the feeder as per instruction of
engineer-in-charge.Test result shall be submitted by contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout drawings with
GIS mapping as per actual cable routing showing road crossing, HDPE pipe sleeving, Set
jointing locations, markers etc.
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm aluminium
sheet along with 1.0 mm dia aluminium binding wire for fixing of aluminium tag near end
166 9925000029 termination joint at DP structure for identifyng the cable. The details of feeder i.e. 11 / 22 No.
KV with feeder name shound be punched on the tag by letter punch of size 16 mm as per
instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations (outdoor) for 11kV 3C x 240 mm2
size XLPE cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for 22 kV 3C x
mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations (indoor) for 11kV 3C x 240 mm2
size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV 3C x 240 mm2
size XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for 11kV 3C x 240 mm2 size
XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for 22kV 3C x 240 mm2
size XLPE cable as per DGVCL technical specification
173 9925000047 Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade trench or in open space Cable
174 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
175 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round pipe No.
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC.
COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND
3 9926000003 PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON THE POLEAND No.
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY CROSSING ON
BG/MG/NG LINE FOR 0.400/11/22KV OVERHEAD LINES I.E INCLUDING EXCAVATION
OF PIT & REFILLING OF EARTH, FIXING CROSS ARMS, TOP FITTING CLAMPS,ANTI-
CLIMBING DEVICES DANGER BOARD, INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLES, FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 METERS.STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
INSULATORS ETC.COMPLETE & PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND NUMBERING WITH COST OF PAINTSAS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH, HG
FUSES OF 8 MTRS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS SUPPORTING ANGLES, CLAMPS,
ANTI- CLIMBING DEVICES, DANGER BOARDS, INSULATORS,DOFUSES ETC.
COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COSTOF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDINGOF ERECTION OF GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG
FUSES, 9 TO 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, FIXING OFCHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METER,200KG PSC POLE METERS POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
9 9926000009 ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING No.
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG
FUSES TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO
METERS STEEL POLES INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH
CARTING OF TRANSFORMERS FROM STORE TO SITE, FIXINGOF CHANNELS
SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING
10 9926000010 DEVICES, DANGER BOARDS,CONDUCTOR AND CABLE WIRING ETC. COMPLETE No.
AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTIONS OF
GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH
AS PER STANDARD SPECIFICATION WITH STAY CLAMPS, STAY WIRE, ANCHOR
ROD, TURN BUCKLE, EYEBOLT, GUY INSULATOR, CEMENT CONCRETE BLOCK
ETC. BUT EXCLUDING CONCRETING.
9926000012 CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF CEMENT SAND METAL CMT
(1:2:4) AND WATER ETC. AS PER STANDARD SPECIFICATION.(cement Should be
grade) used for Concreting.
9926000013 ERECTION OF COIL TYPE EARTHING INCLUDING COST OF COAL,SALT ETC. BUT No.
13 WITHOUT COST OF GI WIRE AS PER STANDARD SPECIFICATION(20kg solt+20kg
9926000014 ERECTION OF GI PIPE/CI PLATE TYPE EARTHING INCLUDINGCOST OF COAL SALT No.
ETC. BUT WITHOUT COST OF PIPE/GIPLATE GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
9926000015 ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH CLAMPS, BRASS NIPPLE, No.
BRASS HOLDER TECK WOOD BUSH,REFLECTORS FUSE, WIRING ETC. AS PER
STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
9926000016 STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA CONDUCTOR for ALL TYPE OF ONE
CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING COND
FIXING OF INSULATORS, BINDING JUMPERING ETC. PER
17 9926000017 STRINGING OF GI WIRE 8 SWG INCLUDING BINDING JUMPERING ETC. DO
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC 2.5/4MM2 TWIN
CORE CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF
18 9926000018 METER WITH METER EARTHING COMPLETE WORK AS PER STANDARD No.
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH PVC
4MM2/10MM2 FOUR CORE CABLE FROM TERMINAL POLE TO METERING POINT
19 9926000019 INCLUDING FIXING OF METER WITH METER EARTHING COMPLETE WORK AS PER No.
STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
9926000020 ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR No.
ERECTION OF POLE/ GUY ETC. AS PER STANDARD SPECIFICATION OVER &
20 ABOVE NORMAL COST COVERED AGAINST EXCAVATION OF PIT UNDER NORMAL
SOIL FOR ERECTION OF POLE,GUY, DOUBLE POLE STRUCTURE EARTHING WITH
THE APPROVAL OF SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
9926000025 Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING,HT LINE No.
CROSSING AND TELEPHONE LINE CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH , HG FUSES,TRANSFORMERS,
LIGHTENING ARRESTOR, DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC
POLE INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER
BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OFGUY
SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS, LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON
9 to 11 METERS RSJ POLE INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
27 9926000027 ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING No.
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS 270 KG PSC POLES
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
9926000030 STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR 11/22KV & LT ONE
LINES INCLUDING FIXING OFINSULATORS, BINDING JUMPERING ETC. COND
9926000031 STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES INCLUDING FIXING ONE
OF INSULATORS, BINDING JUMPERING ETC. COND
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF AB SWITCH,
HG FUSES, TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX.
OF 10 METERS 270 KGAND PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
32 9926000032 ANTI-CLIMBING DEVICES,DANGER BOARDS, CONDUCTOR AND CABLE WIRING No.
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
9926000033 DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF FABRICATION AT No.
33 STORE & STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
9926000034 DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF FABRICATION AT No.
34 STORE & STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITH
TRANSFORMER) WITH CREDITING OF FABRICATION & TRANSFORMER AT STORE
& STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITHOUT
TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
37 9926000037 AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY KM
INSULATED PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION
CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF
38 9926000038 MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH KM
CABLE BY INSULATED PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
39 9926000039 CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS KM
ETC. AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
40 9926000040 CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS KM
ETC. AS REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION
CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF
41 9926000041 MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH KM
CABLE BY INSULATED PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
9926000042 DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE OLD MATERIAL No.
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC
POLE(WITHOUT TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE
AND STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITH
TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
9926000045 DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND CREDITING FITTING KM
45 OF ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND CREDITING
46 9926000046 FITTING OF ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE KM
9926000047 DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND CREDITING FITTING KM
OF ALL ACESSARIES TO DEPARTMENTAL STORE.
9926000048 DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM AND KM
48 CREDITING FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
9926000049 DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM AND KM
49 CREDITING FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
9926000050 RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR ONE
11/22KV & LT LINES INCLUDING FIXING OF INSULATORS, BINDING JUMPERINGCOND
9926000051 RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING , ONE
BINDING JUMPERING ETC. COND
9926000052 LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER. (METER WILL BE No.
PROVIDED BY DGVCL)
9926000053 LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND OLD METER No.
53 SHOULD BE CREDITED TO SDN STORE. (METER WILL BE PROVIDED BY DGVCL)
9926000054 LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER CONNECTION. (CT PER
COIL WILL BE PROVIDED BY DGVCL) CT
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER
55 9926000055 CONNECTION AND OLD CT SHOULD BE CREDITED TO SDN STORE. (CT COIL
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER (MMB WILL BE
PROVIDED BY DGVCL)
9926000057 LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX. (METER WILL BE No.
PROVIDED BY DGVCL)
9926000058 PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER CABLE 3.5 METER No.
(CABLE TO BE PROVIDED BY AGENCY)
9926000059 LABOUR CHARGE FOR PROVIDING/RECONNECTION OF TERMINAL CONNECTION PER
WITH PROPER SIZE OF LUGS. (LUGS COST IS BORNE BY AGENCY) TERMI
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY
OF DEFECT IF ANY. A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN
PRO- FORMA REPORT SHOULD BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PER
PARAMETER OF VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-FORMA IS DTR
FILLED) AS PER THE INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY
OF DEFECT IF ANY. A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN
61 9926000061 PRO- FORMA REPORT SHOULD BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-
FORMA IN FAULT CONDITION IN WHICH READING PARAMETER IS NOT SHOWN IN
9926000062 INSTALLATION OF DTR METER INCLUDING METER BOX, PROVIDING & FIXING OF No.
1.5SQ MM SINGLE STRAND 10 CORE ARMOURED COPPER CABLE (3.5METER),
TERMINATION IN METER & COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
9926000063 INSTALLATION OF DTR METER INCLUDING METER BOX, TERMINATION IN METER No.
63 & COIL ETC. (WITHOUT 10CORE COPPER CABLE) (METER, METER BOX, C.T./P.T.
COIL WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not more than 0.75 mtr with 6 turns minimum
on XLPE Cable with single strand binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT Terminal protector (UV
64 9926000086 Resistance) with using 95/120/150 sq.mm long barrel aluminum lug. (1Set = 3 Nos i.e. on
Supply & Installation of HT EPR Tap on 11/22 kV Distribution Transformer with
replacement of bare conductor by HT ABC conductor (DO bottom side to transformer) after PER
removal of semi conductor by HT ABC (6 inch both side). HT ABC to be supplied by SET
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule,
Pipe-In- Cage (Pic) Type, Earth Electrodes for HT Feeder Pole Having 2000 mm Electrode
Length as per the Tender Specifications and Drawing. (All Materials Will Be Supplied By
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule,
Pipe-In- Cage (Pic) Type, Earth Electrodes for HT Feeder Pole Having 3000 mm Electrode
Length as per the Tender Specifications And Drawing. (All Materials Will Be Supplied By
Supply and Installation of 25 X 3 mm GI Strip having hot dip- galvanized-zinc coating of 80-
100 microns without any joints or welding. Both the end of the GI strip should be connected
with GI nut bolts and required fabrication work for giving separate earthing connections to
(1) Neutral of the transformer
68 9926000090 (2) MS structures of the transformer center (Approximately 25 meter GI strip per Meter
transformer centre
- as per requirement and instruction of Engineer in- charge) (All Materials will be
supplied by Agency)
Supply and Installation of uPVC standard make Pipe of 1.25" diameter for covering GI strip
with UV protected Cable Ties of 550 X 7.6 mm size to bind with pole face(Approximately
meter uPVC pipe for GI strip covering per transformer centre -as per requirement and
instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out
70 9926000093 fuse to Transformer H.T. including Busbar (12 mm sleev) as per technical specification. Meter
(All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out
71 9926000094 fuse to Transformer H.T. including Busbar(15 mm sleev) as per technical specification. (All Meter
Materials will be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-flammable) material with Weather
resistant, Non-conductive bird guard OD=300 MM, ID=33 MM, Width =1.25 MM, one side
cut from ID to OD. (All Materials will be supplied by Agency)
9926000096 Providing and fixing of LT Terminal protectors i.e. Re-useable boot (LT Side 1.1 kV) No
73 including LT (1.1 kV) insulating taps. All live part at LT side shall be covered with fixing of
LT insulating taps.
9926000097 Nylon Net (12 * 15 ft) Per Net
9926000098 Nylon Dori Per TC
9926000099 Labour charge for fitting Nylon Net (All fabricated material for fitting nylon net shall be Per TC
provided by DGVCL)
Total Tender Estimated Amount-
Rupees TwentyFive Lakh Only (Excluding. Gst)
Executive Engineer (O&M),
DGVCL Kadodara Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NOTICE.pdf
Integrity Part.pdf
Detail Technical Specification.pdf
DRAFT TENDER CONDITION.pdf
Schedule-B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .