Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC NEAR ANAJ MANDI SUBHASH NAGAR BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹11.3 L+₹2.5 L (28.4%)Rejected-Finance C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹11.7 L+₹2.9 L (33.4%)Rejected-Finance | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹12.0 L+₹3.2 L (36.2%)Rejected-Finance 113 SURESH SHARMA NAGAR NEAR S S V ENTER COLLEGE BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹13.4 L+₹4.6 L (52.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹16.6 L
EMD Value
₹33,200
Closing Date
13 Mar 2023, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
SPL REPAIRS TO BLDG NO P-74 (LIVING ACCN OF GUARD) AND PROVISION OF 01 X URINAL POINT WITH WATER TANK NEAR ANIMAL SICK LINE AT 06 ADV FD VET HOSP UNDER AGE B/R - I OF GE WEST BAREILLY.
2023_MES_580404_1
8093/C/E8
Open Tender
Civil Works
Item Rate
120 days
GE WEST BAREILLY
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹33,200
Yes
GE WEST BAREILLY
28 Mar 2023
11 Feb 2023
16 Mar 2023
11 Feb 2023
13 Mar 2023
27 Feb 2023
23 Feb 2023
Amount
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles and dismantling of wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for glazed ceramic coloured tiles 300 mm X 600 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles and dismantling of wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) with and including making good the disturbed portion of wall in cement mortar 1:4 complete all as specified and directed.
S & F of factory made steel window or ventilator fixed type with glazing bars complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) with and including making good the disturbed portion of wall in cement mortar 1:4 complete all as specified and directed.
S & F of 1.25 mm thick pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc including cutting holes and making good the same in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed. NOTE: - 10 mm deformed bar shall be provided in bottom portion in each frame and cost of the same shall deemed included in the quoted rate of this item.
S & F of 1.25 mm thick pressed steel frame of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S & F of 35 mm thick (Batten thickness) factory made plain, framed, panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneers on both faces and size of the members of shutter are as per IS-1003 (Part-I) made of kiln seasoned & chemically pressure treated 2nd class hardwood complete all as specified and directed.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, Part-I (Specifications) complete all as specified and directed.
S & F of 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
S & F of 300 mm long mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts complete all as specified and directed.
S & F of 150 mm long mild steel pressed handle, oval type, stove enamelled black complete all as specified and directed.
S & F of 140 mm size (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F of stainless steel curtain rod 32 mm dia of approved quality with two number decorative brackets and end knobs (As per approved design) fixed to brick / concrete wall with rawl plugs and mild steel screws complete all as specified and directed.
S & F of steel windows with pressed steel frame of size 95 X 45 X 1.25 mm thick, side hung shutter including box type hinges with steel handle and steel peg stay complete with glazed openable shutter with glazing bar (open out side) and wire gauged openable shutter without glazing bar(open inside), dovetailed or welded complete all as specified, directed and shown on Drg No. TD/088 dated 07 Jan 2002. NOTE: - Two shutters i.e. wire gauged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit. Rate for filling of PCC in the back of frame shall deemed included in quoted rate. MS grill shall be measured and paid separatly under relevant item of this schedule.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed.
M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing pre-cast cement concrete landing, cover slabs, chullah hoods, chajjas, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:4 including demolition of existing reinforced covers complete all as specified and directed.
Demolition of brickwork built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for complete removal of existing wall treatment including preparing the old decorate wall surfaces and applying one coat of cement base paint complete all as specified and directed.
M & L for complete removal of existing wall treatment including preparing the old decorate wall surfaces and applying one coat of distemper oil emulsion complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for applying 2 mm thick wall care putty on wall / ceiling surface including rubbing down the surface with sand paper after getting dried to obtain a smooth & even surface complete all as specified and directed.
M & L for 20-25 mm thick machine cut Kota stone slab mirror polished as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough including dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in cement mortar complete all as specified and directed.
M & L for 18-20 mm thick machine cut Kota stone slab mirror polished as in risers of steps, skirting, dado and pillar, landing in single piece with round nosing with three numbers of serration, over cement screed bed, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles and dismantling of wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
S & F of 20 mm thick mirror polished granite stone slabs (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, set in over and including 15 mm thick cement screed in cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab and dismantling of wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
Rounding to exposed edges of stone slab as in steps, cooking platform and the like complete all as specified and directed.
Demolition of existing plinth protection any description and thickness and M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 75 mm wide and 3 mm thick glass dividing strip inserted in position at every one meter and change of direction complete all as specified and directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
S & F in repairs water closet vitreous china squatting pan ‘Orissa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed.
S & F in repairs PVC white low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS-7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting not exc. 10 cm in girth complete all as specified and directed.
S & F in repairs 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15 mm bore fancy type, chromium plated stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs 15 mm bore fancy type, chromium plated angle valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs 15 mm bore fancy type, chromium plated stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs vitreous chinaware coloured wash hand basin with pedestal of size 55 X 45 X 82 cm including fancy type chromium plated pillar tap, chromium plated waste coupling, waste pipe and other fixing arrangement, cutting for and pinning in walls and making good complete all as specifed and directed. MAKE- WHB of Cat. No. 10072 & Pedestal of Cat No. Ped 11029 Neptune of Hindware, Parryware Cat No. C0480 (SP) 181/CTH, C 0375 pedestral, Cera Cat No. 2090107 Pedestal and Cat No. S 2040112 for WHB.
S & F of 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F of 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 Kgf per Sqcm and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
Re-fixing of 15 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
Re-fixing of 20 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
Taking up including disconnecting pipes and fittings of any size asbestos cement pressure pipe any class (including all fittings) complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend any radius provided with oval access door complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius provided with oval access door complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal provided with oval access door complete all as specified and directed.
S & F in repairs 100 mm dia grating doom of PTMT (minimum weight 25 gram) complete all as specified and directed.
S & F in repairs 20 mm dia brass chromium plated tubular towel rail ‘D’ type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S & F in repairs 125 mm size brass chromium plated shower rose with or with out swivel joint including fixing to steel pipe or union complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S & F stack clamp made of 50 mm X 5 mm flat iron and 16 mm dia round iron stay including nut bolts and securing ends of stay to wall or roof suitable for 80 mm bore pipe complete all as specified and directed.
S & F stack clamp made of 50 mm X 5 mm flat iron and 16 mm dia round iron stay including nut bolts and securing ends of stay to wall or roof suitable for 110 mm bore pipe complete all as specified and directed.
M & L for providing 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor, laid in panels and finishing top surface even and smooth with using extra cement complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for hard core of gauge exc. 63 mm but not exc. 100 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:2:4 type B-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for 60 mm thick, M-35 grade machine pressed pre-cast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over and including 25 mm thick sand cushioning complete all as specified and directed.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position including dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity alongwith S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) and GI nipples as required complete all as specified and directed.
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2020) complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part-II (2020) complete all as specified and directed.
S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 100 mm long stainless steel butt hinges, medium weight cold rolled with mild steel hinge pin, bright polished complete all as specified and directed.
S & F of 125 mm long anodised aluminium handle, cast type complete all as specified and directed.
S & F in repairs stainless steel plate rack overall weight not less than 5 Kg of size as per sample complete all as specified and directed as per model No. KPR-315 of M/S Blue Star or equivalent of Jayna make.
S & F in repair 125 mm size chromium plated shower rose with or without swivel joints, including fixing to steel pipe or union as per model No. F7010305 of Cera, model No. F160006 of Hindware or model No. T9985 A1 of Parryware complete all as specified and directed.
S & F in repairs PVC toilet cabinet with mirror of overall size 20"X16" of selecred quality complete as specified and directed.
S & F in repairs 75 mm X 32 mm dia chromium plated waste fitting special size suitable for stainless steel sinks including PVC flexible waste pipe of suitable length and approved quality complete all as specified and directed.
S & F in repairs of PVC corners (Set of three) of size (12''X12", 9"X9" and 6"X6") with railling complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance exc. 250 m but not exc. 500 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 75 mm wide and 3 mm thick glass dividing strip inserted in position at every one meter and change of direction complete all as specified and directed.
M & L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster consisting in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:4 finished even and fair complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for glazed ceramic coloured tiles 450 mm X 350 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
S & F of 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 Kgf per Sqcm and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of vitreous china urinals, bowl type (flat back or corner wall type) size 465 X 355 X 265 mm white (minimum) with grating and union for discharge pipe but excluding flushing cistern, flush pipe etc. complete all as specified and directed.
S & F of 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F of 15 mm bore fancy type, chromium plated stop valve/angle valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F of vitreous china wash basin white, flat back, size 580 X 450 mm excluding taps, waste, chain and plug but including brackets, cutting for and pinning in as required complete all as specified and directed.
S & F of 15 mm bore brass chromium plated fancy type basin mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and directed.
S & F of fancy type glass cornor 300 mm radius made of 10 mm thick toughned glass along with railing and fixed with fancy type stainless steel screws complete all as specified and directed.
S & F of PVC waste pipe of suitable dia and length for wash basin and urinal complete all as specified and directed.
S & F of 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F of 20 mm dia brass chromium plated tubular towel rail ‘D’ type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position with and including 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) and GI nipples as required complete all as specified and directed.
M & L for cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M & L for 150 mm bore salt glazed stoneware drain pipes grade ‘A’ laid in trenches and jointed in cement sand mortar 1:1 with spun yarn complete all as specified and directed.
M & L for cutting into existing manhole for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm dia pipe complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, casing-N-caping, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, shade conical etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and distemper / white wash / colour wash etc. complete all as specified and directed.
M & L for point wiring for one light point / fan point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 137.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 137.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the independent board complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F of electronic type fan regulator 230 volts, step type having five steps, switch type, hum free complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate isolated body complete all as specified and directed.
S & F of flush mounting factory made SPN DB's Double door, 4 way, IP-42 Protection, detachable gland plates for MCB fitted with bus bar, earth bar and neutral links with and including taking down old unserviceable one complete all as specified and directed.
S & F of MCB single pole, 240 volts, 6 to 32 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of MCB single pole and neutral, 415 volts, 32 to 40 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F in repairs, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size complete all as specified and directed.
S & F in repairs, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 10 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size complete all as specified and directed.
S & F of LED Lamp 7 Watt, 230 Volt AC integrated circuit complete all as specified and directed.
S & F of Lamp holders PVC /polycarbonate insulated body modular type with back plate suitable for batten fitting/angle fitting complete all as specified and directed.
Taking out old unserviceable earthing any type and M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
Taking down carefully ceiling fan and keeping the safe custody for reuse at site after completion of building repair work including hanging of the same and making electric connection from ceiling rose to fan complete all as specified and directed.
S & F in repairs 1100 volts grade heavy duty 4.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 2.50 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sqmm 2 core with and including taking out old unserviceable one complete all as specified and directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, punning complete all as specified and directed. Note:- Punning thickness of 18 cm will be considered for payment.
M & L for laying brick as in protection covers over cables using sub class 'B' old size bricks laid flat, length wise perpendicular to the axis of cable complete all as specified and directed.
S & F in replacement 40 mm bore GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed.
NOTE:-Tenderers may note that amount of credit Rs 30,200.00 will be deducted from the total amount arrived at the time of Acceptance of tender.
hardeep singh enterprises
JAI SRI RAM ASSOCIATE
M/S Harshri Nath Enterprises
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .