Loading…
Loading…
Tender Value
₹121.6 Cr
EMD Value
₹2.4 Cr
Closing Date
17 Sept 2026, 3:00 pmClosed
Design, Supply, Erection, Testing & Commissioning of feeder line, AEC and BEC in connection with upgradation of 1x25KV traction system to 2X25 kV traction system between Bhadrak Khurda Road section of Khurda Road division of East Coast Railway to meet 3000MT loading target. (174RKM/394TKM)
ECoR-2x25-OHE-BK-01~ECOR
ECoR-2x25-OHE-BK-01
Open
Works - General
30 Months
Bhadrak, Odisha
₹0
₹2.4 Cr
17 Sept 2026
3 Aug 2026
3 Sept 2026
19 Aug 2026
104-Schedule 1 Section 4 Non Ferrous 271127025.00 Below/P
Item Breakup - 101-Schedule 1 section 1 General
Kilometre 1(c)Preparation of Traction Working Rule Diagram along with Working Instructions (App-G)
Each Erection station/Gate 1(d)Supply & Installation of Traction Working Rule Diagram Boards
Square Foot 8(b)(iii) Supply without Insulator and erection of material for termination of all aluminium 25KV Feeder / return conductor (Single SPIDER)
Each 11(a)(i) Supply without insulator and erection of a cut-in (9 Tonne) insulators
Each ECOR-CONST-HQ-ELECTRICAL/ECOR 11(a)(ii) Supply without Insulator and erection of a suspension (9 Tonne) Insulator
Each 11(b) Supply without Insulator and erection of 25 kV Post Insulator
Each 17 (b) Extra for special embedment of earth electrode.
Each 21. Supply and erection of HDPE polymer net on TTC/portal/SPS structures as per the standards laid down in RDSO drawing no TI/MI/0050 Rev-1
Sqm 23(a) Transfer of equipment from one mast or support to another
Each 23(d) Dismantling of Feeder/ Return Conductor
Kilometre 23(h)Dismantling of an Isolator.
Each 23(i)Dismantling of a Post/ Pedestal Insulator
Each 23(j) Dismantelling of PTFE Neutral section.
Set 23(m)Dismantling of cantilever assembly along with insulator
Set 23(p) Dismantling of jumpers (All types).
Each 23(u) Dismantling Work AL Busbar all size & Cu Busbar all size incl. all fittings
Metre 23(v) Dismantling of Booms & other components of Portals/TTC structures (excluding uprights) & drop arms, SPS etc
MT ECOR-CONST-HQ-ELECTRICAL/ECOR
MT 23(w) Dismantling of mast & temporary mast by cutting from 200 mm below the bottom of muffing level
Each 23(x) Dismantling of upright of all type of Portals/ TTC by cutting from 200 mm below the bottom of muffing level
Each 24(a) Uprooting of mast/Portal upright
Numbers 24(b) Cutting and removal of old foundation of masts and portals including back filling of pit
cum 24(c) Drilling of Hole in Mast/Rail as required i.e. for connection of BEC/AEC etc.
Each 24(e) Digging of trench up to 300 mm depth, Laying of BEC and Back filling
Kilometre 24(h) Drilling of Vertical Holes & Grouting of Galvanized Holding Down Bolt of Size 28 mm dia, 950 mm length with 100 mm threaded portion and 850 mm ragged type confirming to IS 2062-92 (Gr-A) including Washers & Nuts.
Each 29 Transportation of materials
MT 8(b)(i)Supply without insulator and erection of material for termination of Single conductor of Over head equipment or terminating wire.
Each Total 74341732.17
Item Breakup - 102-Schedule 1 Section 2 concrete
cum 2(a) (ii) Concrete for foundation and plinth in Rocky Soil (For M-10 and M- 15 grade concrete)
cum 2(a)(iii)Concrete for foundation and plinth in Hard Soil (For M-15 and M-20 grade concrete) ECOR-CONST-HQ-ELECTRICAL/ECOR
cum 2(a)(iv)Concrete for foundation and plinth in Rocky Soil (For M-15 and M- 20 grade concrete)
cum 2 (b)(i) In other than hard soil and rock (For M-10 and M-15 grade concrete)
cum 2(b)(ii) In other than hard soil and rock (For M-15 and M-20 grade concrete)
cum 2(c) (i) Reinforced concrete M-15 grade for foundation
cum 2(e) Concrete for Cylindrical type side bearing foundations (M-15 and M-20) (SBC - 11000 kgf/sqm)
Item Breakup - 103-Schedule 1 Section 3 Ferrous
MT 3(b)(i) Supply and erection of fabricated and galvanised structures (O, N & R type portals) with all necessary components other than masts
MT 3(b)(ii)Supply and erection of Structure steel (traction masts) fabricated and galvanised of all Type : B - series mast.
MT ECOR-CONST-HQ-ELECTRICAL/ECOR 3(b)(iii) Supply & Erection of special fabricated and galvanised steel structures other than Portals & traction- Masts not covered under items 3(b)(i) & 3(b)(ii).
MT 3(c) Supply only of fabricated steel other than masts
MT 3(d)(i) Supply and erection of a Guy Rod Assembly (3232/3242 etc as required, 5001/5001-1/5001-3, 5002, 5004/ 5005 /5005-2/5006-1/ 9070/9071/5006-2, 5007-1, 5008, 5220 with fastners)
Each 3(f) Supply and erection of 25KV Caution Boards/Plates.
Each 8(b)(v) Termination of AEC incl. all fittings &accessories i.e. Strain Clamp, adjuster etc.
Each 16(a)(i) Supply and erection of a structure bond
Each 16(a)(ii)Supply and erection of a Galvanised steel stranded wire structure bond.
Each 16(a)(iii)Supply and erection of a Cross Bond (Flat 50x6 GS/MS).
Each 16(b) Supply and erection of a longitudinal bond.
Each 16 (c) Supply and erection of a transverse and special bond
Each 17(a) Supply & erection of a single earth electrode.
Each ECOR-CONST-HQ-ELECTRICAL/ECOR 22(b)Supply and erection of anti monkey menace
Each 3(e) Supply of steel reinforcement for RCC
MT 4(a)(i)Supply without insulator and erection of single bracket assembly
Each 3(i) Supply and Erection of Retro- Reflective Type DJ ON (CLOSE)/ DJ OFF (OPEN)/ 500m/ 250m/ Train-18/ MEMU Neutral Section Boards
Each 3(m) Supply and Erection of Retro- Reflective type Power Block Working Limit Board.
Each 3(p) Supply and Erection of Set of Isolator Operation OPEN / CLOSE Boards
Set 3(q) Supply and Erection of Number Plate (Retro-Reflective Type).
Each 3(r) Supply and Erection of GI Pipe 50 mm B class at culvert, girder in rocky area, bridge etc. for laying BEC wire.
Metre Total 509464881.00
Item Breakup - 104-Schedule 1 Section 4 Non Ferrous
Kilometre 7(d) Supply & Erection of aerial earth conductor (AEC) with necessary accessories, fittings and fasteners on OHE mast/Portals
Kilometre 12(d)Supply & erection of PTFE Neutral section for 2x25 kV AC Traction system
Set ECOR-CONST-HQ-ELECTRICAL/ECOR
Set 13(a)Supply without Insulator and erection of 25 KV SP Isolators without earth contact assembly.
Each 13 (c) Supply without Insulators & erection of 25kV Double Pole Isolator for 2x25KV syatem
Each 13 (d) Extra for supply and erection of an earth contact assembly in an isolator
Each 15a(ii) Supply & erection of small copper jumper incl required No of PG Clamp 1041-2, Approx length of jumper 1.6m
Each 15(d) Supply of materials and erection of Large copper jumper 160 Sq. mm
Each 18(b) Supply & erection of Solid copper bus-bars 18mm.:
Metre 18(c)(i)Supply & erection of solid copper bus-bar connectors: Bus terminal (6310-1)
Each 18(c)(ii)Supply & erection of solid copper bus-bar connectors: Bus splice (6320)
Each 6(b) Supply & Erection of Current Carrying Flexible Dropper (CCFD) Wire dia 7.5 mm, 25 sq mm along with CCFD Assembly.
Set 15 (a) (iv) Supply & erection of a copper jumper (5mm dia dropper wire).
Each ECOR-CONST-HQ-ELECTRICAL/ECOR
Each 7(e) Supply and Erection of Buried Earth Conductor (BEC) with necessary accessories fittings and fasteners.
Kilometre 5. Supply and erection of span wire. (130Sqmm LS Wire
Metre 37(d) Supply & Erection of Aluminium Jumper
Item Breakup - 105-Schedule 1 Section 5 Insulator
Each 11(bx) Supply of 25 kV Post Insulator for Item 105
Each 13 (ax) Supply of Post & Operating rod insulators for single pole isolators
Set 13(cx) Supply of Post & Operating rod insulators for double pole isolators
Set 4(ax) (i)Supply of Stay arm Insulator Porcelain (CD1050)
Each 4(ax)(iv) Supply of Bracket Insulator Porcelain (CD1050)
Item Breakup - 106-Schedule 1 Section 6A (Non Sor)
Kilometre Supply of 240Sqmm XLPE Copper cable of 26KV/45KV(52KV) suitable for 25 KV traction system as per IEC 60840
Metre ECOR-CONST-HQ-ELECTRICAL/ECOR Laying of one number XLPE powe cable of grade26KV/45KV(52KV) , 240 s q m m direct in ground including excavation, sand cushioning, protective covering (By Bricks) and refilling the trench.etc. as required
Metre Supply, Erection, Testing and Commissioning of 26KV/45KV(52KV) out Door cable Termination Kit (Heat Shrinkable)
Numbers Laying of HT cable (XLPE) of size 1core x 240 sq.mm. in trench through GI pipe/RCC pipe / along or across the structures. With suitable arrangement along with clamps, fastner etc
Metre Cable route indicator (G.I type) Supplying and making cable route marker with 10cm X 10cm 5mm thick G.I plate with inscription there on bolted, welded to 35 mm X 6mm angle iron 60cm long and fixing the same in ground as required
Numbers Total 36122756.10
Item Breakup - 107-Schedule 1 Section 6 B Non-Sor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .