Certain repair/replacement to internal electrification of MD and OTM accn at Mirthal, Perimeter lights, street lights, security lights, DG sets, lightening protection, bldg earthing and allied works at Damtal, Nangal Bhur,Kandrori,Mirthal,Kaunterpur
2019_MES_293329_1
GES/PKT/T-38/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Damtal, Nangal Bhur, Kandrori, Mirthal. Kaunterpur
Refer tender documents and NIT
9 documents required · 9 mandatory
₹500
GE South Pathankot
₹60,000
Yes
25 Feb 2020
28 Oct 2019
26 Nov 2019
28 Oct 2019
25 Nov 2019
11 Nov 2019
28 Oct 2019 - 3 Nov 2019
Amount
Supply and fix in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with 20x3mm copper strip including dismantling old one.
Supply and lay GI tubes light grade galvanised with all fittings laid in trenches etc for protection of cable of following sizes:-
a) 40 mm dia bore
b) 50 mm dia bore
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one. .
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with 20x3mm copper strip including dismantling old one.
Supply and fixing in repair air termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipe medium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
Supply and fixing in repair air termination single pointed copper rod 12mm dia 12mm dia and 300 mm long for fixing on GI pipe medium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
M&L for plain Cement concrete 1:2:4 type B-1, (Using 20 mm graded aggregate) as in foundation block for fixing GI pipe for installation of air termination rod etc. complete all as specified Note:- Unit rates includes for provn of form work for rough finished surfaces and finishing the exposed surfaces with 5 mm thick rendering in CM 1:3 all specified.
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanised iron or steel wire including dismantling old one.
Supply & Fixing in repair GI pipe medium grade 40 mm dia for fixing Aluminium strip 25x3.15 mm on roof for lightening protection duly drilling 2 Nos holes on Aluminum strip and GI pipe on one end and fixing with screws/suitable size of bolts & nuts complete all as specified. Note: GI Strip required will measured and paid separately.
Supply and fixing in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws including provision of 30 cmx25cmx8cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangement and duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
Material and labour earthing with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to20×3mm copper strip as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe,Copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) and dismantling old defective earthpit.
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd ISI marked complete all as spd.
All as per Srl item 22 above but 3.15mfd complete all as spd.
All as per Srl item 22 above but 4mfd complete all as spd.
Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. Make NBC/SKF (bearing with 8 balls shall only be used) complete all as spd.
Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
S & F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
S & F PVC Two way connector for ceiling fan complete all as specified and directed.
Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/site requirement/Make of fan complete all as spd.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
Dismantling and Re-winding of exhaust fan/industrial wall mounting fan/pedstral fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
All as per Srl item 34 above but 400mm-450mm sweep complete all as spd and directed..
S & F louver, suitable for exhaust fan of any make and size upto 300 mm, fixed in repair complete all as specified and as directed.
All as per item 36 above but of size 400 mm
All as per item 36 above but of size 450 mm
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/wall mounting fan/Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Taking down carefully from wall after unscrewing nut/bolts geysers 50/25 ltr capacity and strip opening the same for taking out internal tank, syphon assembly etc and re-assembling and re-fixing after repair, spares to be replaced shall be measured under respective items of Sch here-in-after.
Supply and replacement internal copper/SS tank of geyser 25 ltr ISI marked capacity complete with syphon –assembly, 1.5/2.0 kw element , rubber gasket , thermostat switch , all as specified and directed. The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .)
Supply and replacement of syphon assembly ISI marked made out of brass of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directed.
Supply and replace thermostat switch ISI marked for geyser AC 230 volt adjustable range from 0-90 degree Celsius )
Supply and replacement cup type geyser element AC 230 volt, of rating 1500/2000 watt.
Supply and replace triangular type geyser element AC 230 volt, of rating 1500/2000 watt.
Supply and replacement outer body suitable for 25 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified and directed.
Supply and replace glass wool of 25 ltrs capacity geyser complete all as specified and directed by Enginner-in-Charge.
Supply and replace indicator lamp square/round type suitable for geyser 25/50 ltr all as per sample AC 230 Volt.
Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 1.0 Sqmm.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed. Make: C&S/Hager/Indoasian/Havells.
De-scaling of geyser of capacity 25/50 ltr after taking down the geyser from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of geyser complete all as directed by Engineer-in –Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
Replacement of spring loaded air release valve ISI marked suitable for 25 and 50 ltrs capacity Geysers.
Replacement of safety valve / dead wt. valve ISI marked suitable for 25, and 50 Ltrs capacity geysers.
Supply and replace pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm .
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm.
Supply and fixing anchor SS bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor SS bolt shall be grouted with hammer drill only)
All as per Srl item 58 above but 25 ltr capacity –ditto-
Supply and replace brass non return valve suitable for 25/50 ltr geyser of size 15 mm.
Supply and replace bottom cover plate of geyser of capacity 25/50 ltr complete with MS screw all as per sample.
Dismantling of Insulated hot water storage tank of capacity 200/300/500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
Service and descaling of Solar Evacuated tube Collector/Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity 200 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
Replacement of heating element 2/3 KW suitable for stand by back up supply to solar water heater.
S&F in replacement stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
Supply and fix in replacement of rotational moulded polyethylene water storage tank three layer of 1000 Ltr storage cap with float valve 20mm dia PTMT with proper fixing on stand with Including suitable connected with accessories as specified or directed by Engr-in-carge. (Note: MS Angle measured and paid separately)
S&F laminated sticker of size 8"x12" having background of navy blue and letters of white colour as directed by Engr-in-charge. The words shuold have in capital letters. The following do's and don't shall mentioned of the sticker :-
(i) The geyser should be switched on 60 to 75 minutes before the actual time when hot water is required.
(ii) Switch off the geyser during night.
(iii) Switch off the geyser when not required for 3 to 4 hours continuously.
(iv)The indicator lamp indicates that the current is passing through the heating element and water heater is working.
(v) In case any water leak is noticed from any part of geyser including accessories, should be reported to MES.
DON'TS
(i) Don’t Keep the geyser switched on during night or at the time when not required.
(ii) Don't adjust the high pressure reducing valve.
(iii) Don't use the geyser when indicator lamp is not working.
(iv) Don't use the geyser when three pin plug with necessary earthing connection have not been provided.
(v) Don't switch on the geyser if water does not come out from the delivery tap.
(vi) Don't close inlet water stopcock.
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
Point wiring for one light point or fan point controlled by one switch with 1.5 sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green color) as earth lead drawn in and including non metallic rigid PVC conduit including new pressed steel sunken box of required size as directed by Engr in Charge & 3mm thick plastic laminated top sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
All as per srl item 83 above but for one light point controlled by 2 nos two way switches.
All as per srl item 83 above but for one 3 pin 5A socket outlet independent board.
All as per srl item 83 above but for one 5A socket outlet on the same board
All as per srl item 83 above but for one 5A socket outlet below the board.
All as per srl item 83 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green color) as earth lead drawn in and including non metallic rigid PVC conduit medium grade with all fittings (ISI Marked) controlled by one switch including new pressed steel sunken box of required size, & as directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including making good the disturbed surfaces to match with the existing specification complete all as specified.
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole two way 5 amps, 230 volts. Note : The quoted rate inclusive for the following :-.(a) The material shall be ISI marked. In case of non-availability, the certificate for the same to be submitted (b) Test certificates to be submitted before commencement of work/ claiming for payment .(c) Warranty certificate for minimum 2 years to be submitted from OEM.
M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts. Note : The quoted rate inclusive for the following :-.(a) The material shall be ISI marked. In case of non-availability, the certificate for the same to be submitted (b) Test certificates to be submitted before commencement of work/ claiming for payment .(c) Warranty certificate for minimum 2 years to be submitted from OEM.
M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 15 Amp, 230 volts. Note : The quoted rate inclusive for the following :-.(a) The material shall be ISI marked. In case of non-availability, the certificate for the same to be submitted (b) Test certificates to be submitted before commencement of work/ claiming for payment .(c) Warranty certificate for minimum 2 years to be submitted from OEM.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 5 Amp and 15 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 5 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body 2 in 1, 5 pin 5 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body 2 in 1, 5 Amp and 15 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts.
M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified.
M and L for replacement of existing old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed.
M & L for replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
S & F for replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting, fixing with proper round block all as directed.
Supply & fix in replacement Heavy duty vaccum pressure impergenated copper ballast (VPIT) for CFL 9/10/11 watts.
All as per srl item No-101 above but for 18 watts
Supply & fix in replacement compact fluorescent lamp 9 watts 230 volts 6500 K, 2 pin
Supply & fix in replacement compact fluorescent lamp 11 watts 230 volts 6500 K, 2 pin
Supply & fix in replacement compact fluorescent lamp 18 watts 230 volts 6500 K, 2 pin
Modular point wiring for One light point or one fan point or bell point controlled by one module switch SP 230 Volts with 1.50 sqmm in FRLS PVC insulated copper conductor cable ( multistrand) single core PVC insulated cable in existing PVC concealed conduit terminated in new sunken pressed steel boxes of suitable size as required at site including inner and outer frame plate for mounting of modular switches/socket/ fan regulators and continuous earth wire 1.5 Sqmm FRLS copper cable PVC insulated controlled by one switch for one light/ fan /sockets point/ all as specified and directed by Engr-in-Charge. (Note:- In ceiling Portion surface conduit wiring to be done). Note: Modular inner and outer frame plate shall be included in quoted rate. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
All as per srl item 106 above but for one 3 pin module socket out let 5/6 Amps on same board.
All as per srl item 106 above but for one module socket out let 5/6 Amps on Independent board.
All as per srl item 106 above but for one module socket out let 5/6 Amps on below the board.
All as per srl item 106 above but for one light point controlled by 2 nos two way module switches.
All as per srl item 106 above but for one 3 pin 15 Amps module socket outlet independent with 2.5 sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in existing PVC conduit.
M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI Marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable switch piano with Modular switch 2 way 6A, 1 module ISI Marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI Marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing old u/s submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 4 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
M & L for replacement of existing old u/s submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 6 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
M & L for replacement of existing old u/s tube light fitting with energy saving decorative batten type fitting with LED tube rod 18 watt energy efficient tube light fittings LED complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of suitable size from ceiling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90. Note :(i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply and Fix in replacement existing UNSV tube light fitting with LED 20W inverter batten type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and fixing LED Bulk head light fitting 1X10watts complete , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required. Note :(i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply and fix in replacement existing UNSV Recess/suspended slim LED panel light with powder coated rim 36 watt of size 2x2 feet high efficiency designer recessed mirror optic luminary with ceiling cut out size 36 watt including LED lamps complete including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required and specified by Engr-in-Charge. Note :(i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F in replacement existing UNSV decorative round surface mounted slim LED panel of 18 watt with powder coated finished in white housing complete with all accessories and including LED lamp, connection up with three core twisted flexible copper conductor cable with suitable size. Note :(i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F in replacement existing UNSV decorative square recess mounted slim LED panel of 18 watt with powder coated finished in white housing complete with all accessories and including LED lamp, connection up with three core twisted flexible copper conductor cable with suitable size. Note :(i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
M & L for replacement of existing old u/s mirror light fittings with sleek energy efficient decorative LED mirror light 10 watts, 2 feet with diffuser complete with all accessories prewired and making connection with 3 core copper flexible cable of suitable size from ceilling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90. Note :(i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F inverter LED 7 watt 230 volts,50 Hz, ,lumen 700 lm, rated current 35 mA, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specified and directed.
S&F inverter LED 9 watt 230 volts,50 Hz, ,lumen 900 lm, rated current 45 mA, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specified and directed.
S&F inverter LED 12 watt 230 volts,50 Hz, ,lumen 1200 lm, rated current 60 mA, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specified and directed.
Supply & fix in replacement of existing old u/s Choke eletronic with choke electronic 40/36 watts 230 volts domestic use complete all as specified and directed.
Supply & fix in replacement of existing old u/s choke eletronic 28 with choke electronic suitable for T-5 fitting watts 230 volts domestic use complete all as specified and directed.
S & F in replacement existing UNSV lights with wall mounted decorative bracket light with designer frosted glass globe 20Watt with prefixed lamp of 20 watt complete.
Supply & Fix in replacement sheet metal enclosure with DB's ( grouted in walls) double door type IP-43 Protection,Isolated Neutral, Door earthing, cement spill protector, IK-08 for MCB's 04 ways with 200 Amps 240 volts rated copper bus bar all as specified. Note : (i) The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.(ii) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment
Supply & Fix in replacement sheet metal enclosure with DB's ( grouted in walls) double door type IP-43 Protection,Isolated Neutral, Door earthing, cement spill protector, IK-08 for MCB's 08 ways with 200 Amps 240 volts rated copper bus bar all as specified. Note : (i) The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.(ii) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment
Supply & Fix in replacement sheet metal enclosure with DB's ( grouted in walls) double door type IP-43 Protection,Isolated Neutral, Door earthing, cement spill protector, IK-08 for MCB's 12 ways with 200 Amps 240 volts rated copper bus bar all as specified. Note : (i) The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.(ii) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment
Supply and fix in replacement of Surge protection device Single phase of rating 10KV/KA for Distrubution board complete all as specified and directed.
Supply and fix in replacement of Electronic driver suitable for 36 watt LED lights complete all as specified and directed.
Supply and fix in replacement of Electronic driver suitable for 18 watt LED lights complete all as specified and directed.
Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN C curve ,240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including replacement of defective and providing thimble for outgoing cable.
Replacement of unserviceable MCCB 63 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge
Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge
Supply and fix in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, including replacement of defective and providing thimble for outgoing cable upto 35 sqmm having sliding shutter.
M&L for replacement of existing unserviceableVTPN DB and S & F in replacement Metal enclosure VTPN which is shock, rust, dust, impact and vermin proof with internally embedded gaskit high grade gasket. The enclosure suitable size with degree of protection IP-54,Isolated neutral bus bar ,Cement spill protector,door earthing DBs double door type TPN suitable for MCCB as incommer and MCB as outgoing AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCCB and MCB will be measured separately). Note : (i) The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.(ii) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment
S & F for replacement of existing u/s tube rod 36 watt with LED tube rod 18/20 watt energy efficient tube light 4 feet long . Note power factor should not be less than 0.90.
Supplying and fixing in replacement of old u/s service cable size 4 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per srl item 146 above but for service cable of size 6 sqmm,complete all as spd and directed.
All as per srl item 146 above but for service cable of size 10 sqmm,complete all as spd and directed.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes 16 sqmm 4 core complete all as specified and directed..
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes 25 sqmm 4 core complete all as specified and directed.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
All as per Srl item No 151 here in above but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Supply, lay and testng cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.
Supply and fixing in replacement of lights sensitive switches with outer sensor,sensitive distance 50m current capacity 16A & control from 1 lux to 100k lux complete all as specified and as directed.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels .
Supply only the following spares suitable for LED street/Flood light fittings :-
Electronic driver suitable for 90 to 120 W LED light fitting
Electronic driver suitable for 70 to 80 W LED light fitting
Electronic driver suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Supply only the following spares suitable for street/Flood light fittings :-
Ballast SV/MH 400 W
Ballast SV/MH 250 W
Ballast SV/MH 150 W
Ballast SV/MH 70 W
HPSV/MH lamps 400 W
HPSV/MH lamps 250 W
HPSV/MH lamps 150 W
HPSV/MH lamps 70 W
Igniters for 150W to 400 W
Tube rod 14 watt T-5
Electronic ballast 1x14 watt
Electronic ballast 4x14 watt
Lamp Holder suitable for suitable for MH/HPSV 70 to 250 W
Lamp Holder suitable for 40 watt LED
LED Lamp 40 watt
Dismantling LED light fitting of capacity 90 to120 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of capacity 70 to 80 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of capacity 40 to 60 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of capacity 25 to 36 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2300 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 25 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings from any height andSupply & fixing Solar smart intergreted Solar LED Street light fitting (All in one type) with built in Mono Crystalline Panel, lithium ion battery (LiFePO4), MPPT charger controller, PIR sensor with colour temp 600-6500 K with minimum 40 W capacity LED light fittings with hybrid switch, Mono crystalline solar panel of capacity 48W+ 4W (mono), PIR sensor, IP65, 12.8V, 27 Ah lithium ion (LiFePo4) battery inbuilt in fitting, MPPT charge controller with efficiency > 90%, CRI > 70, autonomy for minimum 2 days, charging time 1 day, suitable for working temperatures -10 Degree C to +55 Degree C, fixed on 9.0 meter steel tubular pole/RCC pole complete all as directed & specified. Note : The rate is inclusive of fitting, battery, controller etc complete. The GI pipe bracket along with clamps will be measured and paid separately.
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4200 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6800 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 11000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 9500 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 100 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete. Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Taking down old unserviceable street light fittings from any height and Supply & Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 8500 lumens suitable wattage for efficiency not less than 95 lumens/Watt,min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc complete and testing on completion all as specified and as directed. Note: The GI pipe if rquired bracket will be measured and paid separately under relevant schedule items
Note for Item No.186 to 196 here in above : (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD - < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity - 10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 using 20 mm graded aggregate for coping of poles and stay including form work.
Supply and fixing timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one .
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 8 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 8 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and as directed by Engr-in-Charge.
Decarbonising of the control panel of High mast/Mid mast and including sevicing of parts such as contactors/timers including replacement of pitted lugs,thimbles, control wiring etc complete including painting with a coat of synthetic enamel paint
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
M&L for preparation of old painted surfaces of 9 m long PCC poles incl removing oily/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.5 mtr height including applying a coat of white wash on pole coping and lettering the pole details with with white letters/ blackground etc complete all as directed
S&F in replacement of cone LED bollard 8 watt, 5700 K complete with all accessories including dismantling defective and connecting electrically all as specified and as directed.
Material & labour for decarbonising of LT panel board of any size/ capacity made out of thermoplastic-polycarbonate boxes with IP-65 protection by taking shut down of panel & strip opening of boxes carefully, cleaning the carbon content with CTC solution, replacement of embedded polyurethane gasket,replacement of pitted control wiring, thimbles ,replacement of nuts, bolts ,washers, cable glands/ PVC gromates, cable lugs, tightening the busbar chamber, dismantling the broken/ defective boxes, inspection of Ammeters/ Voltmeters/ Multifunction meters re-assembling after replacement of new boxes, testing & commissioning complete all as directed. Note : The defective thermoplastic-polycarbonate boxes, LED Lamps,Ammeters , Voltmeters, Multifunction meters, CTs will be measured and paid separately under relevant schedule items .
Supply only the following spares for carrying out repairs to under relevant Sch item above
CTs moulded type class-1.0, 5VA burden suitable for AC 230V (phase-earth )50 Hz supply busbar system of suitable for ratio range 100 to 800/5 Amps capacity
LED Indication Lamps
Thermoplastic-polycarbonate boxes shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant , with inetrnally embedded gasket high grade made of polyurethane, with IP 65 protection suitable for 415 V 50 Hz 63 to 160 A 3/4 pole MCCB with cable entry .
Thermoplastic-polycarbonate boxes shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant , with inetrnally embedded gasket high grade made of polyurethane, with IP 65 protection suitable for 415 V 50 Hz 200 to 320 A 3/4 pole MCCB with cable entry .
Thermoplastic-polycarbonate boxes shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant , with inetrnally embedded gasket high grade made of polyurethane, with IP 65 protection suitable for 415 V 50 Hz 400 to 630 A 3/4 pole MCCB with cable entry .
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor.
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR.
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR.
M&L in replacement of existing unserviceable cantactor MNX-25/MNX-40 at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed .
M&L in replacement of existing unserviceable contactor MNX-9 /MNX-18 at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed .
M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
M&L in replacement of existing unserviceable MCB 32 - 63 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage.
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 12 Stage.
Maintenance and servicing of DG set consisting of replacement of fule filter, air filter and lub oil filter including replacement of eninge oil all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM.Note: Engine oil will be measured and paid seperately.
(a) DG Set 7.5 KVA to 25 KVA.
(b) DG Set 30 KVA to 50 KVA.
(c) DG Set 62.5 KVA to75 KVA.
M & L for replecement of existing unservicible Fan Belt and testing complete for the following capacity of DG Sets and any make as per OEM.
(a) DG Set 7.5 KVA to 25 KVA.
(b) DG Set 30 KVA to 50 KVA.
(c) DG Set 62.5 KVA to 75 KVA.
M & L for replecement of existing unservicible Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make: :-
(a) DG Set 7.5 KVA to 25 KVA.
(b) DG Set 30 KVA to 50 KVA.
(c) DG Set 62.5 KVA to75 KVA.
Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed for the following capacity of DG Sets and any make as per OEM.
(a) DG Set 10 KVA to 25 KVA.
(b) DG Set 30 KVA to 50 KVA.
(c) DG Set 62.5 KVA to75 KVA.
M&L for repair and overhauling of unsv self starter 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
M&L for repair and overhauling of unsv dynamo/alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 34 KVA to 75 KVA.
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 180 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 100 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed
M & L for repair of Water pump of 10.5 to 40 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M & L for repair of Water pump of 50 to 75 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 10 to 40 KVA DG Set of any make and model complete all as directed.
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 50 to 75 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calliberation of fuel injector assembly including replacement of unsv/defective spares of 10 to 40 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calliberation of fuel injector assembly including replacement of unsv/defective spares of 50 to 75 KVA DG Set of any make and model complete all as directed.
Supply and fix in replacement battery leads set, PVC insulated multisranded, copper conductor of min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets of different capacities.
M/L for replacement of coolant for radiator for DG set at various locations.Make: Servo/HP/Indian Oil.
M/L for replecement of Lub Oil (Engine Oil) of grade 20W40 for Engine for DG set at various locations.Make: Servo/HP/Indian Oil.
M & L for replacement of starter ring gear assembly for capacity 34 to 50 KVA DG set.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including replacement of PVC pipe fuel level indicator, writing of tank capacity, date of cleaning and next due date for tank to be cleaned for following capacities of DG Set and any make as per OEM.
(a) DG Set 10 KVA to 25 KVA.
(b) DG Set 30 KVA to 50 KVA.
(c) DG Set 62.5 KVA to75 KVA.
M & L for scrapping of old paint from DG set and preparation of old painted surfaces for re-painting. Repainting complete body of DG set with superior quality super enamelled paint of colour as per standard engineering practice for engine, alternator, base frame etc by sparying including writting SM/MES No, all as specified and directed.
(a) DG Set 10 KVA to 25 KVA.
(b) DG Set 30 KVA to 50 KVA.
(c) DG Set 62.5 KVA to75 KVA.
Sch of Credit = 130771.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
KULBHUSHAN AGGARWAL
M/S Vijay Punj Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .