Nanditha M T, ASSISTANT ENGINEER
The Assistant Executive Engineer, LIDEW Subdivision , Ponnani Block Panchayat
Annual Plan-Ponnani BP 2025-26- Electrification of motor shed-at Kanthallur Padasekharam Vattamkulam GP
2026_LSGD_855620_3
02/AE/LIDEW/BP-PNI/2026
Open Tender
Electrical Works
150 days
EDAPPAL
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹1,509
Yes
12 Jun 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
20 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1elefn | ||||||
| 1.001 | OD57761/2026-2027:Supply and installation of dust & vermin proof, 3 phase syntex meter board(GSMB-6535 STD-NF) to fix KSEB meters ,fuse units, CT etc as required including fixing it on wall, making good the damages, colour washing etc and giving connection as required | - | each | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | OD57876/2026-2027:Supply and providing32A HRC fuse link with base and giving connection in the existing meter board | - | each | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | OD57875/2026-2027:Supply and providing 32A neutral link mounted on DMC/SMC base and giving connection in the existing meter board | - | each | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) | - | sqm | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N | - | each | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
40 amps | - | each | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | OD57872/2026-2027:Supply and fixing T&T make MU-G6 DOL Starter relay range 6-10 A Cat NO SS 97756 COVO consisting of volt meter/ Ammeter/ single phasing cum dry run preventor etc suitable for 5 HP submersible motor pump set on existing board and giving connection etc as required | - | each | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 90.14.24.17:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. | - | each | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | OD57882/2026-2027:Supply and providing digital multi function meter to readV,A,F,3phase accuracy class 0.5 in the existing panal board and giving connection as required | - | each | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tendernotice_2.pdf
PDF • 0.18 MB
Tendernotice_3.pdf
PDF • 0.10 MB
PA.pdf
Tender Documents • 0.19 MB
viewsbd (1).pdf
Tender Documents • 1.64 MB
viewsbd.pdf
Tender Documents • 1.64 MB
AFFIDAVIT.pdf
Tender Documents • 0.17 MB
FT.pdf
Tender Documents • 0.18 MB
BOQ_1446062.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid