Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹18.3 L+₹3.1 L (20.5%)Rejected-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | L2 | Rejected-Finance L2 bidder | |
| 3 | L3₹19.5 L+₹4.3 L (28.3%)Rejected-Finance 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L3 | Rejected-Finance L3 bidder | |
| 4 | L4₹19.6 L+₹4.4 L (29.3%)Rejected-Finance | L4 | Rejected-Finance L4 bidder |
Tender Value
₹18.6 L
EMD Value
₹28,000
Closing Date
28 Jul 2021, 3:00 pmClosed
The Chief Engineer, Sports Engineering Wing
Directorate of Sports and Youth Affairs, Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Upgradation and Renovation of Swimming Pool and Premises
2021_DSYA_427472_2
36/SEW/CE/2021-22
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram
Previous experience as clause 1.3.7 and 1.3.8
7 documents required · 7 mandatory
₹2,500
Yes
₹28,000
Yes
16 Sept 2021
14 Jul 2021
29 Jul 2021
14 Jul 2021
28 Jul 2021
14 Jul 2021
Amount
ELECTRICAL WORKS
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.4.5.4 : 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/ Watt), Air delivery minimum 210(cubic meter/minute), 300mm down rod , 2 number canopies, shackele kit, Copper winding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitable for 230V/240V single phase AC supply etc. complete as required
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/ Isolator16 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od273760/2020_2021 : Supply and installation of pre-wired,20W LED Batten fitting complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
od273761/2020_2021 : Supply of 250 mm sweep Light Duty Exhaust fan in plastic body with self opening;lowers working on 230 V single phase A/C as required
od273762/2020_2021 : Supply and installation of FRP burial type conical pole of overall height 3.9 mtr shaft length 3.9 mtr burial depth 0.9 mtr nominal depth 3 mtr with all accessories complete as required
od273763/2020_2021 : Supply and installation of 30 W post top LED bollard light fittings with die cast aluminium housing having IP 65 protection in the existing light post with all accessories complete as required
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
od273764/2020_2021 : Servicing of 1Ton AC units including the compressor, fan motor, evaporator unit and checking the filter units and filling R22 gas required with all accessories
od273765/2020_2021 : Supply installation testing and commissioning of single phase 1.5TR Split A/C Unit of approved make complete with suitable capacity drive motor ,air cooled condenser with all accessories,including condenser and evaporator coil(copper) ,hermitically sealed rotary compressor,copper piping ,drain piping etc including suitable stabilizer as required
od273766/2020_2021 : Supply and providing additional Copper piping(1/2"; & 1/4") per Mtr (including in & out) for the 1.5 TR Split AC units including sleev covering with necessary accessories complete as required
90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.50 sq.mm
90.12.7.3 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 10 sq.mm with factory made clamp
90.12.1.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 2 core 4 sq.mm
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.15.4.4 : Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.11 : Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
od273767/2020_2021 : Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in including RCC foundation and junctions box etc.complete 3 Meters
od273768/2020_2021 : Dismantling the existing MH light including the Choke and holder all accessories at the direction of Engineer in charge
90.6.6.3 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes. 4 sq.mm
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 6 sq.mm with factory made clamp
90.16.1.1 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required (14 SWG)
od273769/2020_2021 : Supply, installation, testing, and commissioning of single phase 1.5 HP submersible pump of approved to make including the starter for the motors and with all accessories.
od273770/2020_2021 : Supply and installation PH controller with panel mounted LED indicator for display with all accessories
od273771/2020_2021 : Supply Installation Testing and commissioning of 3kVA online ups Double conversion IGBT pure sine wave 72V with 6 nos of 12V tubular batteries for 3 hours backup with fixing stand
Fire Panel works
od273747/2020_2021 : Supply and laying of 2x 1.5sq.mm armored Copper FRLS cable ISI marked with proper clamping, supports, and terminations appropriately above ground as per technical specification
od273750/2020_2021 : Supply, installation, testing, and commissioning of hooter cum strobe at different locations complete for both audio and visual indication with all fixing accessories, etc. under the false ceiling, roof, wall, etc., with a time delay of max 30sec, interconnecting loop cable complete as requiredas per the technical specification. The product shall be FM approved and UL Listed.
od273752/2020_2021 : Supply, installation, testing, and commissioning of Addressable/Conventional type Multi-Detector (photoelectric cum rate of rising temperature type) complete with all accessories like base. base box, etc. to be installed under/above the false ceiling, roof, and concealed space, etc. interconnecting to loop cable complete as required. Shall be UL listed and FM Approved, complete as required as per the technical specification.
od273754/2020_2021 : Supply, installation, testing, and commissioning of Manual Call Point with break glass, hammer, and chain, complete as per Tech. Spec. Make:Win Fire /Ravel or equivalent
od273756/2020_2021 : Supply and fixing of Fire Extinguisher-CO2 4.5 Kg Type including with clamps
od273758/2020_2021 : Supply and fixing of Fire Extinguisher-ABC 5 Kg Type including clamps
od273759/2020_2021 : Supply and fixing of 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet
PA System
od273743/2020_2021 : Supply and providing Wired Lapel Microphone: Wireless Lapel Microphone: Wireless Lapel Microphone with following specification, Digital Wireless Lapel Mic incl. Condenser ,Wireless reciever, Body Pack Transmitter with Frequency Response:60 Hz – 12 kHz, Polar pattern Cardioid, Max. Sound Pressure Level:139 dB, Sensitivity:-43.50 dBV/Pa, Input impedance:22 kΩ as required
od273749/2020_2021 : Supply installation testing and commissioning of Portable Speaker: RMS Power Subwoofer: 700 W , Array Satellites: 300 W, Number of array satellites 4, Number of Smartlink adapters 1, Number of subwoofers 1, Max. SPL 125 dB, Frequency response 40 - 20000 Hz, Dispersion 110° horizontal x 34 °vertical, Wall-mounted Loudspeaker: RMS Power 80w, Max Power 160w, Dispersion 110° horizontal x 110° vertical, Impedance 8 Ohm, Portable Array System: RMS Power 80w, Max Power 160w, Dispersion 110° horizontal x 110° vertical, Impedance 8 Ohm as required
Lightening Protection
od273745/2020_2021 : Supply and installation vertical run - Round wires - , 8 mm / 50 mm², AlMgSi, semi-rigid Round wire according to DIN EN 62561-2 (VDE 0185 Part 202) for use as air-termination system or down conductor in lightning protection systems.Diameter Ø conductor: 8 mm Cross-section: 50 mm2 Material: AlMgSi Materi. with Conductor holder for Metal Roof.
od273748/2020_2021 : Supply and Installation of Universal connector For cross-connections, T connections and parallel connections Material of clamp: StSt Clamping range Rd: 8-10 mm Screw: M10 x 35 mm Standard: EN 62561-1
od273751/2020_2021 : Supply and installation of 1000 mm air terminal with accessories: Air-termination rod 10mm, total length: 1000 mm, Al Air-termination rod for protection of roof-mounted structures, Holder For air-termination rods Ø 10 mm
od273753/2020_2021 : Supply and Providing and fixing of test joint with an enclosure suitable for 10mm dia copper bonded solid steel round conductor with 100 microns of copper bonding (if pure copper conductor 25x3 mm solid tape also can be used) and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.
od273755/2020_2021 : Supply and installation of Providing and laying StSt solid round conductor 10mm diameter from earth electrode directly in-ground as required. StSt, high corrosion-resistant (Meets the requirement of (IS/IEC 62305
od273757/2020_2021 : Supply and Installation of Earthing: C-Bar 3/4"; dia, UL listed, 3000 mm long + 22.6 Kg GC+ and clamp for termination
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Power Care Electrical
POZITIVE POWER INDIA PVT LTD
ABM Electricals
Bidder Name
ABM Electricals
Power Care Electrical
POZITIVE POWER INDIA PVT LTD
SREEJITH S G
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_610400.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .