Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.5 L+₹1.3 L (10.1%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
12 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati-15 Assam Pin 781015 Tele 0361 2841626
ADDN/ALTN TO ALKALINE BATTERY CHARGING ROOM AT AF STN KUMBHIRGRAM
2023_MES_589329_1
CWE(AF)/KUM/TOKEN-37 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Kumbhirgram
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I AF Kumbhirgram
₹30,000
Yes
14 Jul 2023
13 Apr 2023
19 May 2023
13 Apr 2023
12 May 2023
27 Apr 2023
Amount
M & L for 15mm thick plastering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including taking down old damaged cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
Supply only water proofing compound as per latest IS specification complete all as specified and as directed.
M&L for Complete removal of existing treatment, including preparation of plastered or unplastered surfaces of wall and applying two coats of Acrylic emulsion exterior paint of required shade (Company Depot Tinted) @ 1.67 litre/ 10 sqm over and including a priming coat of exterior primer applied @ 2.20 litre/ 10 sqm over old decorated surfaces of wall complete.
M & L for 15mm thick plastering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement including taking down old damaged cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
Preparation of newly plastered internal surfaces of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and as directed.
M & L for 5mm thick plastering in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement including taking down old damaged cement plaster including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and as directed.
M&L for 15 mm thick screed bed or bedding layers in cement mortar (1:4) mixed with WPC as per manufacturer's instruction in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, finished even and smooth without using extra cement complete all as specified and directed. (NOTE : WPC & Polymeric membrane shall be measured and paid separately under relevant item ).
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with WPC as per manufacturer's instruction finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed. (NOTE : WPC shall be measured and paid separately under relevant item ).
M&L for Demolition of existing roof padding like lime concrete etc and Taking down tarfelt with tiles and cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc and providing water proofing treatrment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.25 ltrs/ sqm over plastered surfaces of roof incl parapet surface. (b) Over the priming coat laying one layer APP based polymeric membrane of approved manufacturer 3mm thick weight not less than 3.50 Kgs / Sqm reinforced with non woven polyester febric weight not less than 160 gms/ Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymeric membrane shall be done torch on method or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) APP bassed polymeric membrane shall be "Dr Fixit" manufacturered by M/S Pidilite Industries or "MOPLY FP 3MM" manufactured by M/S Texsa India Limited and 'Hyperplus" by IWL India Limited (iv) Applying two coats of Aluminium paint over APP membrane@100gms/sqm.)
Taking down chowkats or frame with shutters (without taking off shutters from the frames ) exc. 1.5 sqm but n.exc. 4 sqm each complete all as specified and as directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frames ) n.exc. 1.5 sqm each complete all as specified and as directed.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S&F aluminium window and ventilator shutters powder coating of any colour (Thickness or powder coating not less than 50 micron) sliding type glazed, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S&F powdered coated (minimum 50 micron) aluminium anodised (minimum 15 micron) frames for windows and ventilators (Square/rectangular/channel type as required) of size 47.62mm x 44.45mmx 2.17mm thick ( 1.072 Kg/m) with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed.
S&F 12mm thick Pre laminated exterior grade both side laminated board complete all as specified and as directed.
S&F in repair aluminium deco grills confirming to DG-104 grade complete all as specified and as directed.
Supply and fix Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
Supply and fix Mortice latch with two levers (vertical type), aluminium anodised body and fixed complete all as specified and as directed.
Supply and fix 200 mm long Aluminium anodised barrel tower bolt extruded section (Conforming to IS) complete all as specified and as directed.
Supply and fix fancy type stainless steel handles, 300mm long complete all as specified and as directed.
M&L for making good jambs, forming jambs etc to opening, including cutting, toothing and properly bonding into old work, also facing, jointing, pointing and painting to match the existing work complete all as specified and as directed.
Dismentling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified and as directed.
M& L for 75mm thick PCC type C-2, 1:3:6 (using 40mm graded stone aggregate) in plinth protection including necessary formwork complete all as specified and as directed
M&L for 20mm thick screed bed or bedding layer in CM 1:6 as in floor complete all as specified and as directed
M&L for non skid ceramic coloured tiles 300mmX300mmX7mm thick in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed.
All as per serial item No 28 above but as in skirting in vertical surfaces with and including screed bed of 10mm thick in CM 1:4 complete all as specified and as directed.
M&L for Glazed ceramic tiles on vertical surfaces 350x250x7mm / 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete with and including screed bed of 10mm thick in CM 1:4 all as specified and as directed.
M&L for preparing of old surfaces of walls and applying two coats of oil emulsion distemper on the same after complete removing the existing treatment and preparation of internal wall surfaces with minimum1mm thick wall care putty and appying one coat of primer complete all as specified and as directed.
Demolition of cement concrete ,(reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified and directed.
Mild steel TMT bar 10 mm and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.
Material and Labour for RCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L for cutting V shaped grooves in existing cracks removing all loose particles, paints, dust etc including filling up the prepared groove surfaces with solvent free moisture tolerent thyrotropic two part structural adhesive and repair mortar Sikadur - 31 or equivalent as approved by AGE(I) complete all as specified and as directed.
Excavation in trenches in soft/loose soil etc n. exc 1.5 m wide and exc 1.5m but n.exc 3m in depth for foundation etc or for laying of pipe, cable etc and getting out complete all as specified and directed by Engineer-in-charge.
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point, complete all as specified and as directed.
Material and Labour for dry sand cushioning with coarse sand in trenches for protection of underground electric cable 8cm deep before laying the cable and 15cm thick after laying & stretching of cable complete all as specified and as directed. (Note:- Only punned thickness of 18cm shall be measured and paid)
Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed.
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with aluminium conductor 1100 volts grade of cross sectional area 25 Sqmm 4 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply and fix hi wall split units indoor/outdoor comlete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air qualiy with minimum 3 star rating and EER 3.2 of capacity as 1.5 TR all as specified and directed Note : Cost and provision of making holes for necessary connections through the existing walls, PVC pipe 15 mm bore dia for draining out condensated water, copper tube with insulated material for complete Job brickwork with sub class 'B' brick with cement mortar 1:6 and randering with 15 mm on fair face of brick work with cement mortar 1:4 , including making shed with structural iron of size 50x60x6 mm with GI sheet, having platform of size 0.6x0.45x0.9 M for keeping outdoor unit of split AC complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA all as specified and directed
Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc, complete all as specified and directed.
Material and labour for point wiring with two single core PVC insulated & shathed copper conductor cable 1100 Volts grade HR FR of size 1.5 Sqmm (nominal area) each drawn through and including stove enamelled steel conduit of suitable size (concealed) for flame proof wiring complete with flame proof accessories with one 1.5 sqmm single core PVC insulate solid copper conductor cable 1100 Volts grade HR FR as earth continuity wire, for one light point/fan point controlled by one flame proof switch complete all as specified and as directed.
Material and labour for point wiring with two single core PVC insulated & shathed copper conductor cable 1100 Volts grade HR FR of size 1.5 Sqmm (nominal area) each drawn through and including stove enamelled steel conduit of suitable size (concealed) for flame proof wiring complete with flame proof accessories with one 1.5 sqmm single core PVC insulate solid copper conductor cable 1100 Volts grade HR FR as earth continuity wire, for one flame proof 5 Amp Socket Point (Independent) controlled by one flame proof switch complete all as specified and as directed.
Material and labour for point wiring with two single core PVC insulated & shathed copper conductor cable 1100 Volts grade HR FR of size 1.5 Sqmm (nominal area) each drawn through and including stove enamelled steel conduit of suitable size for (concealed) flame proof wiring complete with flame proof accessories with one 1.5 sqmm single core PVC insulate solid copper conductor cable 1100 Volts grade HR FR as earth continuity wire, for one flame proof 5 Amp same board controlled by one flame proof switch complete all as specified and as directed.
Material and labour for point wiring with two single core PVC insulated & shathed copper conductor cable 1100 Volts grade HR FR of size 4.0 Sqmm (nominal area) each drawn through and including stove enamelled steel conduit of suitable size (concealed) for flame proof wiring complete with flame proof accessories with one 4.0 sqmm single core PVC insulate solid copper conductor cable 1100 Volts grade HR FR as earth continuity wire, for 15 Amp Power point controlled by one flame proof switch complete all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated un-sheathed cable 1100 Volts grade HRFR with multi-stranded copper conductor of 6 sq mm size and drawing into and includig stove enamelled steel conduit of suitable size (concelaed) for flame proof wiring with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 4.0 sqmm, single core, as earth continuity wire all as specified and as directed. Note: Two runs of 6 Sqmm cable and one run of 4 Sqmm earth continuity conductor shall be measured as one run length.
Supply and fix FLP/WP Switch/Isolator 10 Amps single pole for ON/OFF all as specified and directed
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 6A, 250V, 2P+earth complete all as specified and directed
Supply and fix flame proof fan regulator complete all as specified and directed
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as per specified and directed
Supply and fixing LED light fitting 30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fixing flame proof sheet metal enclosure for MCB DBs, phosphatised, Powder coated , single pole and neutral (12 way SPN ) 240 Volt , neutral bar and with blank plate for covering of balnk mcb position complete all as specified and directed.
Supply and fixing sheet metal enclsourefor MCB DBs CRCA phosphatised power coated, 415 volt netural bar and with blank plate for covering of balnk MCB position complete all as specified and directed.
Supply and fix MCB TPN 63 Amps 415 volts complete all as specified and directed
Supply and fixing Amp rating, 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity 32 Amp SPN in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in proper position MCB single pole of capacity upto 6-32 amps, 240 Volts C-curve with 10kA breaking capacity complete all as specified and directed
M&L for Earthing complete with galvanized steel earth plate electrode 600 x600 x 6 mm, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the of plate not less than 1.5m below ground level connected to galvanized earth strip 32x6 mm by means of bolt, nut, check nut and washer of galvanized iron or steel earthing lead to be protected by galvanized iron pipe of 40 mm bore light grade and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20 mm bore galvanized iron pipe medium grade for watering wire mess, charcoal or coke and common salt in alternative layers of 15cm (compacted thickness) all around the earth electrode, concrete earth pit in PCC(1:3:6) type CI, 50mm thick precast RCC (1:2:4) type B1cover slab reinforced with 8mm dia TMT bar @ 15cm C/C both ways and suitable handle made out of 10mm dia , including necessary excavation and earth work, returning filling and disposal of surplus soil to a distance n. exc 50m and testing on completion complete all as shown in electrical plate No 3 SSR Part-I and as directed.
M&L for taking down carefully existing fire alarm system with 8 Nos smoke sensor complete with all accessories and re-fixing the same at same place after the completion of addition alteration work with all minor parts by authorised person of fire alarm system with serviceability testing of fire alarm system complete all as per specified and directed. (Note:- If any damages in parts of fire alarm system will be replaced with new one by the contractor own risk)
Taking down exhaust fan and kept aside or handed over to MES store yard for taken into account and fill the complete hole of exhaust fan with necessay PCC, plaster work to match with the existing surfaces complete all as specified and directed
M/S PIJUSH BHATTACHARJEE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .