RequiredExperience with Government
RequiredOEM Authorization Certificate Emergency Lighting And Accessories (Portable Emergency Lighting System Tower Type With Battery Bank ( 30 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Portable emergency lighting system consisting Rechargeable Battery Bank
RequiredCharging unit with charging cables
RequiredMobile (from vehicle) charging kit and cables
RequiredTower/Telescopic Yes * 1/7 collapsible mast/Vertical mast
RequiredLED Luminaire
RequiredSupporting kits
RequiredTool Kits
RequiredStorage box for tool kits (Tool kit list to be furnih by seller at the time of supply) Type of battery Rechargeable * Chemistry of battery Lithium ion SMF Lead acid battery
RequiredLithium ion Battery capacity (minimum) 12 Ah * Minimum continuous working hours 10 hours 2 hours
Required4 hours
Required8 hours
Required10 hours
Required12 hours
Required18 hours Minimum System Lumens 5000 * IP rating of LED Luminaire IP65 IP54
RequiredIP65
RequiredIP66
RequiredIP67
RequiredIP68 Ruggedised Storage Box for main equipment Yes * TOWER CONSTRUCTION Minimum height of Tower/telescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) 3 metre 1 metre
Required2 metre
Required3 metre
Required4 metre
Required5 metre
Required6 metre
Required8 metre Material of Tower/lel escopic/Vertical Mast Aluminium Aluminium
RequiredMild steel
RequiredGalvanised Iron
RequiredFiber
RequiredStainless steel Minimum thickness of Tower/lelescopic collapsible mast/Vertical Mast material (+/-5%) 3 mm 3 mm
Required4 mm
Required5 mm
Required>5 mm Method of step up and step down of To wer/lelescopic/Vertic al Mast Winch mechanism Pnumatic
RequiredHydraulic
RequiredMotorised
RequiredWinch mechanism Step up and step down time of Tower/lelescopi c/Vertical Mast </=30 sec * The strength of the Tower/telescopic collapsible mast/Vertical Mast tower is to provide 40 km/hr 20 Km/hr
Required40 km/hr
Required50 Km/hr
Required80 Km/hr 2/7 support for it to remain erect at wind speed of BATTERY CONSTRUCTION Number of battery 1 1
Required2
Required3
Required4
Required6
Required8
Required10
Required12
Required16
Required20 Battery voltage 12 Volt * Battery bank construction shall have inbuilt charging arrangement with charging cables Yes * System must have Battery charging arrangement with AC power source input and with DC power source input with necessary cables Yes * Additional charging cable and kits for battery charging from automobile vehicles (Mobile charging option) Yes * Warranty card for battery 1 Year 1 Year
Required2 Years
Required3 Years
Required4 Years
Required5 Years System shall also work on 220/240V
Required50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes * LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * LED Modules as per the IS: 16103(Part-2)/2012 Yes * Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * LED chip Efficacy ≥130 Lm/Watt * 3/7 Colour temperature (+/-500K) 6000K 6000K
Required5000K
Required4000K Working life for LED (Minimum 50
Required000 burning hours as per LM-80 report) >/= 50
Required000 burning hours * Colour Rendering Index(CRI) ≥70 * Optic lense materal (UV stabilised) Poly carbonate lense * The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest IP66 IP66
RequiredIP67 Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover/polycarbonate and the metal housing to exclude the entry of the dust
Requiredwater
Requiredinsects etc.
RequiredYes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass/poly carbonate cover thickness >/=4 mm * Toughned Glass polycarbonate shall not get discoloured shall not suffer degration due to heat and ageing Yes * 4/7 within warranty period Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Operating temperature range -10 deg C to +50 deg C -20 deg. C to +50 deg. C
Required-10 deg C to +50 deg C "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed * Date of manufacture (month-year)
Requiredand lot number as identification mark inside each unit and the outside of each packaging box Yes * REPORTS AND CERTIFICATION Availability of type tet reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine
RequiredAlternator and Luminaires as per relevant IS specifications as applicable Yes * Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes * Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report Yes * 5/7 and Photo biological report for LED report from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Consignee) LED Luminaire shall have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting system as on date Yes * Total Weight of complete system (Must declare) in Kg </=10 Kg * Warranty for complete system 1 Year 1 Year
Required2 Years
Required3 Years
Required4 Years
Required5 Years Storage battery shall have Complusory Registration(CRS) of BIS as per IS 16270 : 2014 as applicable as on date Yes * * Bold specifications are the golden parameters.