| Sl No | Description | Qty | Unit | Precision Engineers and Buildings L4 | M/s ABUTURAAB ELECTRICAL ENGINEERING L3 | AL-AWAAL BUILDERS AND DESIGN PVT LTD L1 | ARISE ENGINEERING WORKS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Carriage upto site (including Loading/Unloading),Testing and Erection of Steel Tubular Pole, 11 Mtr. Long Pole(ST-410 SP-56) with planting depth of 1/6 th of the height of the pole, (11 mtr. Long ) as per approved drawings/standards | 10 | No. | 31,999 ₹3,19,990 | 30,000 ₹3,00,000 Lowest | 46,000 ₹4,60,000 | 45,000 ₹4,50,000 |
| 2.00 | Supply, Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (100 Sqmm ACSR Conductor-Dog) as per approved drawings/standards | 9.27 | Km | 1,55,000 ₹14,36,850 | 1,40,000 ₹12,97,800 | 1,10,000 ₹10,19,700 Lowest | 1,25,000 ₹11,58,750 |
| 3.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Channel/ GI V X Arms/Extension Top/Angle Iron/Flat/Belting Angle/Anti Skidding Clamps/Fuse plates of various sizes including clamps as per approved drawings/standards | 320 | Kg. | 139 ₹44,480 | 110 ₹35,200 | 90 ₹28,800 Lowest | 145 ₹46,400 |
| 4.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of PG/T Clamps suitable for 100 Sqmm ACSR as per approved drawings/standards | 600 | No. | 120 ₹72,000 | 225 ₹1,35,000 | 40 ₹24,000 Lowest | 175 ₹1,05,000 |
| 5.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm (reputed make)as per approved drawings/standards | 30 | No. | 499 ₹14,970 Lowest | 600 ₹18,000 | 1,000 ₹30,000 | 500 ₹15,000 |
| 6.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with disc fitting (reputed make) as per approved drawings/standards | 6 | No. | 500 ₹3,000 Lowest | 700 ₹4,200 | 1,500 ₹9,000 | 500 ₹3,000 Lowest |
| 7.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvinized Nuts and Bolts as per approved drawings/standards | 15 | Kg. | 139 ₹2,085 | 105 ₹1,575 | 200 ₹3,000 | 100 ₹1,500 Lowest |
| 8.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2.5 Mtr long with GI strip (25x3)mm as per approved drawings/standards | 10 | No. | 499 ₹4,990 Lowest | 620 ₹6,200 | 1,500 ₹15,000 | 700 ₹7,000 |
| 9.00 | Supply & Laying of Cement bottoming for 11 Mtr ST Pole in 1:2:4 mix as per Standards 0.66 cum / pole including the Loading/Carriage/Unloading of required material. | 10 | No | 2,200 ₹22,000 Lowest | 3,500 ₹35,000 | 5,000 ₹50,000 | 2,500 ₹25,000 |
| 10.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2No.), anchor plate (300x 300 x 8 mm), nut-bolts, 2No.turnbuckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete as per approved drawings/standards | 2 | No. | 100 ₹200 | 3,000 ₹6,000 | 100 ₹200 | 1 ₹2 Lowest |
Tender Value
₹22.9 L
EMD Value
₹45,800
Closing Date
8 Jan 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer STD Sopore
Amargarh Sopore
Twining of 3 Km of 33 KV Watergam Line under Augmentation of 33 KV lines/ New Lines-PDDSS2021101361
2025_PDD_298612_1
STDS/ 30 of 2025-26
Open Tender
Electrical and Maintenance Works
Turn-key
90 days
STD Sopore
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,007
Yes
Executive Engineer STD Sopore
₹45,800
Yes
15 Jan 2026
19 Dec 2025
9 Jan 2026
19 Dec 2025
8 Jan 2026
22 Dec 2025
19 Dec 2025 - 22 Dec 2025
Amount
Supply, Carriage upto site (including Loading/Unloading),Testing and Erection of Steel Tubular Pole, 11 Mtr. Long Pole(ST-410 SP-56) with planting depth of 1/6 th of the height of the pole, (11 mtr. Long ) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (100 Sqmm ACSR Conductor-Dog) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Channel/ GI V X Arms/Extension Top/Angle Iron/Flat/Belting Angle/Anti Skidding Clamps/Fuse plates of various sizes including clamps as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of PG/T Clamps suitable for 100 Sqmm ACSR as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm (reputed make)as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with disc fitting (reputed make) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvinized Nuts and Bolts as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2.5 Mtr long with GI strip (25x3)mm as per approved drawings/standards
Supply & Laying of Cement bottoming for 11 Mtr ST Pole in 1:2:4 mix as per Standards 0.66 cum / pole including the Loading/Carriage/Unloading of required material.
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2No.), anchor plate (300x 300 x 8 mm), nut-bolts, 2No.turnbuckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete as per approved drawings/standards
Supply,Testing,Loading,Carriage,Unloading and fixing of Danger Plates with Clamps as per approved drawings/standards
Supply,Testing,Loading,Carriage,Unloading and fixing of Anti-Climbing Device with Clamps as per approved drawings/standards
Providing & Painting of Poles (11Mtr Long) with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards
Engagement of skilled labour along with necessary machinery(power saw) for cutting and clearance of tree branches interfering with electrical lines (whereever required), including proper disposal/stacking of cut material, complete with all tools, tackles, machinery, and safety equipment, as per directions of the Engineer-in-Charge
CONTENGENCIES /T&P
Supply of ISI-marked Safety Helmet made of high-quality, impact-resistant HDPE/ABS material, equipped with adjustable headband, chin strap, ventilation system, and sweat-absorbent inner lining, conforming to IS:2925 standards, of approved make and colour, as per directions of the Engineer-in-Charge
Supply of ISI-marked Safety Belt / Full Body Harness made of high-strength polyester webbing with adjustable shoulder and thigh straps, equipped with double lanyard, shock absorber, and forged steel snap hooks, conforming to IS:3521 standards, of approved make and quality, as per directions of the Engineer-in-Charge
Supply of Earthing Discharge Rod suitable for safely discharging high-voltage lines/equipment up to 33 kV, made of high-quality epoxy/fiberglass insulating rod with metallic clamp, complete with 16 sqmm multi-strand copper earthing cable of adequate length and earthing terminal, conforming to relevant IS/IEC standards, complete with carrying case, of approved make and quality, as per directions of the Engineer-in-Charge
Supply of ISI-marked industrial Safety Shoes made of genuine leather with steel toe cap, oil/acid/slip resistant PU sole, shock-absorbing heel, and padded ankle support, conforming to IS:15298 (Part 2) standards, of approved make, size, and quality, as per directions of the Engineer-in-Charge
Supply of Electrical Rubber Insulating Gloves suitable for working up to 33 kV, made of high-dielectric natural rubber, seamless, ergonomically designed, conforming to IS:4770 / IEC 60903 standards, duly tested and certified, complete with manufacturer’s test certificate, of approved make and quality, as per directions of the Engineer-in-Charge.
Supply of A4 size Copier Paper (210 mm × 297 mm), 75–80 GSM, 500 sheets per rim, smooth finish, suitable for high-speed photocopiers and printers, packed in moisture-proof ream wrappers, of approved make and quality, as per directions of the Engineer-in-Charge.
Supply of Original HP 335X High Yield Black Original LaserJet Toner Cartridge , high-yield type ensuring clear and smudge-free printing, duly packed and sealed, with manufacturer’s warranty, of approved make and quality, as per directions of the Engineer-in-Charge.
ARISE ENGINEERING WORKS (BID ID -2692231)
M/s ABUTURAAB ELECTRICAL ENGINEERING (BID ID -2692591)
Precision Engineers and Buildings (BID ID -2692609)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tendernotice_2.pdf
PDF • 1.52 MB
BOQ_968018.xls
BOQ • 0.30 MB
ilovepdf_merged_compressed.pdf
Tender Documents • 8.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .