Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical KAMRUP ASSAM 781124 INDIA UDYAM AS 16 0006860 | KAMRUP | ASSAM | 781124 | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | L.G REFRIGERATION L1 | IMPERIAL COOLING SOLUTIONS L2 |
|---|---|---|---|---|---|
| 1.00Incidental repairing of 02 (Two) No.Walk in Chiller machine (Modular Cold Room) (Blue Star make) of Capacity 6000 BTU/Hr (for nominal size 6'X6'X8' ) and 10000 BTU/Hr (for nominal size 10'X8'X8') with hermetically sealed Reciprocating compressor operating on refrigerant R-404A, for operation on 230 V (single phase), 50 Hz, AC supply with PUF Wall,floor and ceiling panel,PUF insulated hinged type door ,S.S rack etc. with following spares . | |||||
| 1.01 | Providing, fitting, fixing of hermetically sealed reciprocating compressor for suitable for above specification complete as per direction of the Engineer-in-charge. | 1 | No | 12,000 ₹12,000 Lowest | 42,000 ₹42,000 |
| 1.02 | Providing, fitting, fixing of Microcontroller / Data lodger with display for suitable for above specification complete as per direction of the Engineer-in-charge. | 1 | No | 8,000 ₹8,000 Lowest | 18,000 ₹18,000 |
| 1.03 | Leak testing of condenser & evaporator unit for performance, flashing, gas charging and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge. | 2 | No. | 2,500 ₹5,000 Lowest | 15,000 ₹30,000 |
| 1.04 | Providing and fitting fixing of Sensors for suitable for above specification complete as per direction of the Engineer-in-charge. | 2 | No | 500 ₹1,000 Lowest | 7,000 ₹14,000 |
| 2.00 | General servicing of Walk in Chiller machines (as per Sl No.-1) including all routine & preventive checks/tests/maintenance, cleaning of condenser/evaporator coils, chiller room with suitable detergent/chemical solution and flushing with high pressure jet of water/blower, filter replacement etc for satisfactory working of the system as per direction of the Engineer In-charge. | 1 | Job | 3,000 ₹3,000 Lowest | 22,000 ₹22,000 |
| 3.00 | Comprehensive Annual Maintenance (CAMC) for above specification Walk in Chiller (as per Sl No.-1) complete as per direction of the Engineer-in-charge. installed at Blood Bank of GBP hospital for 01 (one ) year. | 1 | Job | 1,90,000 ₹1,90,000 | 1,40,000 ₹1,40,000 Lowest |
Tender Value
₹2.8 L
EMD Value
₹5,562
Closing Date
17 May 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division, Agartala
Incidental repairing general servicing and post repairing CAMC for one year of 02 Two No Walk in Chiller Blue star make at Blood Bank of AGMC and GBP Hospital Agartala
2025_CEPWD_61148_1
12_EE_DNIeT_MECH DIVN_AGT_2025_26
Open Tender
Electrical Works
Works
410 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹5,562
3 Sept 2025
8 May 2025
17 May 2025
8 May 2025
17 May 2025
8 May 2025
Amount
Incidental repairing of 02 (Two) No.Walk in Chiller machine (Modular Cold Room) (Blue Star make) of Capacity 6000 BTU/Hr (for nominal size 6'X6'X8' ) and 10000 BTU/Hr (for nominal size 10'X8'X8') with hermetically sealed Reciprocating compressor operating on refrigerant R-404A, for operation on 230 V (single phase), 50 Hz, AC supply with PUF Wall,floor and ceiling panel,PUF insulated hinged type door ,S.S rack etc. with following spares .
Providing, fitting, fixing of hermetically sealed reciprocating compressor for suitable for above specification complete as per direction of the Engineer-in-charge.
Providing, fitting, fixing of Microcontroller / Data lodger with display for suitable for above specification complete as per direction of the Engineer-in-charge.
Leak testing of condenser & evaporator unit for performance, flashing, gas charging and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge.
Providing and fitting fixing of Sensors for suitable for above specification complete as per direction of the Engineer-in-charge.
General servicing of Walk in Chiller machines (as per Sl No.-1) including all routine & preventive checks/tests/maintenance, cleaning of condenser/evaporator coils, chiller room with suitable detergent/chemical solution and flushing with high pressure jet of water/blower, filter replacement etc for satisfactory working of the system as per direction of the Engineer In-charge.
Comprehensive Annual Maintenance (CAMC) for above specification Walk in Chiller (as per Sl No.-1) complete as per direction of the Engineer-in-charge. installed at Blood Bank of GBP hospital for 01 (one ) year.
IMPERIAL COOLING SOLUTIONS (BID ID -175766)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_62192.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .