| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC LOWEST | |
| 2 | Rejected-Technical | - | Rejected-Technical Reject |
Tender Value
₹59.9 L
EMD Value
₹1.1 L
Closing Date
29 Nov 2021, 6:00 pmClosed
CWEHILLSDEHRADUN
CWE HILLS MALL ROAD DEHRADUN
REPAIR/MAINT OF INTERNAL WIRING, SUBMAIN WIRING, MCB DBS AND OTHER CONNECTED/MISC WORKS IN ZONE B AREA UNDER GE CLEMENT TOWN
2021_MES_467472_1
85330/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CLEMENT TOWN
Class C Cat bi
8 documents required · 8 mandatory
₹1,000
Yes
GE CLEMENT TOWN
₹1.1 L
Yes
13 Jan 2022
12 Aug 2021
1 Dec 2021
12 Aug 2021
29 Nov 2021
17 Nov 2021
Amount
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down carefully by unscrewing from ceiling roses, Light fittings for reuse at site, and refixing the same after repair etc complete all as specified and directed
Dismantling and taking down carefully sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed.Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified
Taking down old unserviceable meter box of any size & any type from wall by disconnecting all electrical connections complete all as specified & directed
Taking down energy meter from unserviceable meter box carefully and re-fixing on new panel board, sealing with sealing compound and wire complete all as directed & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item no 7 mentioned here-in-before but One 3 pin/5 pin 5 Amps/6 Amps socket outlet on same board with other switches .
All as per item no 7 mentioned here-in-before but One 3 pin/5 pin 5 Amps/6 Amps socket outlet on indepdent board with other switches .
All as per item No 7 above but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size.
All as per item No 7 above but With cables 2.5 sq mm size. Pvc insulated FRLSH cable for 15 Amps power point
Material & Labour for Point Wiring for one call bell point / light Point/ one fan point controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including surface rigid PVC conduit on wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed.
All as per item No 12 above but One 3pin/5pin 5/6 Amps socket out let on same board with other switches ,
All as per item no 12 mentioned here-in-before but One 3 pin/5 pin 5 Amps/6 Amps socket outlet on indepdent board with other switches .
All as per item No 12 above but controlled by two way switch 5/6 Amps ,
All as per item No 12 above but With cables 2.5 sq mm size. Pvc insulated FRLSH cable for 15 Amps power point
All as per item No 7 above but in existing concealed conduit.
All as per item No 8 above but in existing concealed conduit.
All as per item No 9 above but in existing concealedconduit.
All as per item No 10 above but in existing concealed conduit.
All as per item No 11 above but in existing concealedconduit.
All as per item No 12 above but in Casing and Caping
All as per item No 13 above but in Casing and Caping
All as per item No 14above but in Casing and Caping
All as per item No 16above but in Casing and Caping
Supply and fix Modular switch 1 way 6 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and directed . Make: Legrand cat No:6734-01 / Indoasian Cat No: 800000 or equivalent make of L&T /Havells
Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and as directed . Make: Legrand cat No: 6734 11/ Indoasian Cat No: 800002 or equivalent make of L&T /Havells
Supply and fix Modular Socket outlet, 6A -2/ 3 pin combined, 2 module ISI marked, 230 volts, 50 hz all as specified and directed .Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or equivalent make of L&T/Havells
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module complete all as specified.Make: Legrand cat No: 6734 85 / Indoasian cat no: 800022 or equivalent make of L&T/HavelS
Supply and fixing switch modular flush type single pole, two way 6 Amp, 1 modulecomplete all as specified and as directed .Make: Legrand cat No: 6734 02 / Indoasian cat no: 800001 or equivalent make of L&T/HavelS
Supply and fixing modular bell push single pole one way 6 Amps 1 module complete complete all as specified and a0485 / Indoasian cat no: 800007 or equivalent make of L&T/HavelS
Supply and fixing step socket type modular fan regulator 120/280 V , 2 module all as specified.
Supply and fixing bell ding dong AC 230/240 Volts single pole
Supply and fixing ceiling rose surface bakelite 65x25mm dia having three terminals all as specified
Supply and fixing batten/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
Supply and fixing as in repair switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC complete all as specified and as directed.Cat part no HSN8536/14111 OF Anchor, HSN 8536/9001 0f cona or equivalent in Havells .
Supply and fixing as in repair switch piano flush single pole, one-way15/ 16 Amp, 240 Volts AC complete all as specified and as directed Cat part no HSN8536/33118 OF Anchor, HSN 8536/9216 0f cona or equivalent in Havells .
Supply and fixing as in repair socket out let 3/5 pin 5/6 Amps flush type complete all as specified and as directed Cat part no HSN8536/14302 OF Anchor, HSN 8536/9001 0f cona or equivalent in Havells .
Supply and fixing as in repair socket out let 5/6pin 5/15 Amp and 15 Amp flush type (multi) suitable for 240 Volt Accomplete all as specified and as directed Cat part no HSN8536/14307 OF Anchor, HSN 8536/9146 0f cona or equivalent in Havells ..
Supply and fixing in repair bell ding dong AC 230/240 Volts single pole
Supply and fixing as in repair batten/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.Cat part no HSN8536/38538 OF Anchor, HSN 8536/3966 0f cona or equivalent in Havells
Supply and fixing in repair step socket type fan regulator 120/280 V all as specified.
Fixing only LED lights fitting mirror type with high out put diffuser 2 feet, 10 watt 220V, AC including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Fixing only LED lights fitting 1X20 watt , 220V, AC decorative box type with driver, holder including LED tube rod 20 watt, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Fixing only LED light fitting 1X10watts bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified & as directed.
Fixing only round shape 6 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
fixing only round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Fixing only round shape 12 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.( Note :- LED light fiitings mentioned under item No43,44,45,46,47 and ,48 will be issued under Sch B free for fixing only )
S& F Glaze Wall Light including 9/10 watt LED lamp ( B22), 6500 K , Cat part No- LHFOECE1TZ1B014 of make Havells or equivalent in Philips/ C&S / Crompton all as specified and as directed
Fixing only LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and as directed Connection toluminaire shall be done in suitable PVC connector wwithin the bracket/luminaire end and are inclusive in above.
Fixing only LED luminaire 600mm X 600mm, 35/36 watt, 220V AC recessed type suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed. ( Note :- LED light fiitings mentioned under item No 50 and 51 will be issued under Sch B free for fixing only )
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415 V AC 4 way with 200 Amps rated bus bar all as specified and directed .
Fixing only LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 on and S&f GI light grade pipe 40mm bore bracket of suitable size including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and as directed Connection toluminaire shall be done in suitable PVC connector wwithin the bracket/luminaire end and are inclusive in above.
Supply and fixing sheet metal enclosure double door type for MCCB DBVTPN 4 way with 160 Amps with 36 KA ,4 POLE MCCB COMPLETE all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBS DB SPN 12 way with 200 Amps with rated bus bar COMPLETE all as specified and directed .
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity all as specified.
Supply and fixing MCB 5 to 30 Amp 'B' series 10 KA repturing capacity complete all as specified.
Supply and fixing MCB isolator 4 pole 63 Amps 240 V 10 KA repturing capacity all as specified. Make -Legrand, ABB/ Schnider
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with 01 No, RCCB 25 Amp, DP, 240 Volts, AC Complete all as specified.
Supply and fixing single pole and neutral enclosure modular type with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC all as specified. Make -Legrand, ABB/ Schnider
Taking down old u/s cable & Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 25 sqmm 4 core complete all as specified & as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cables, pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed
M & L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable ( measurement to be taken after punning down consolidated thick ness ). complete all as specified and as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FR ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall as per existing along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FR ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable 1100Volts grade in existing conduit along with 4.0 Sq mm PVC insulated unsheathed copper conductor cable as earth wire and wire connected with main earth dolly including making good surfaces all as specified and directed
Supply and fixing temper proof electronic meters in repair, testing commissioning and sealing of temper proof LCD display with polycarbonate cover 230/240 Volt, capaciaty 10-60Amps (Single phase) acccuracy class-I, 50 Hz, confirming to IS 13779, IP-54 with parameter to show data, time current reading , load, PF , voltage and KWH complete including electric connection incoming and outgoing with PVC insulated unsheathed multi stranded copper conductor FR cable single core 1100 Volt grade of size 4 sqmm with proper tinned copper lugs and Flexible PVCconduit medium grade 20 mm dia surface concealed where required and taking out of old electric meter and unserviceable cable complete all as specified and directed.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size 900X700X250mm minimum suitable for 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following :- (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleave and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings. ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three)
INCOMING SUPPLY:- i) MCCB 100 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No Make of MCCB -L&T/Siemens/Legrand/Schneider. OUTGOING SUPPLY:- i) MCB SPN 40 Amps 230 Volts, 50Hz, ruptiring capacity 10 KA = 5 Nos, Make of MCB-L&T/Siemen /Legrend/Schneider. ii) Space required for 04+1 Nos Electric Energy meter single Phase, AC 240V, 10-60 Amps iii) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible . Notes:- 1. The panel manufacturer should have following certification:- i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from GE (MES) Clement Town, Dehradun before fabrication. 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size 1350X700X250mm suitable for 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following :- (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleave and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings. ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three)
INCOMING SUPPLY:- i) MCCB 125 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No Make of MCCB -L&T/Siemens/Legrand/Schneider. OUTGOING SUPPLY:- i) MCB SPN 40 Amps 230 Volts, 50Hz, ruptiring capacity 10 KA = 07 Nos, Make of MCB-L&T/Siemeris/Legrend/Schnelder. ii) Space required for 06 Nos Electric Energy meter single Phase, AC 240V, 10-60 Amps iii) DMC Connector 2 way 100 A for outgoing submain supply-7 Nos Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible . Notes:- 1. The panel manufacturer should have following certification:- i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from GE (MES) Clement Town, Dehradun before fabrication. 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2.
Supply and laying , un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmX 150mmX40mm with breaking load capacity 200 KG complete all as specified & as directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .