Executive Engineer,Tapi (R & B) Division,Vyara
Construction of Godown Building (2500 Metric Ton Capacity ) At Khushalpura, Taluka-Vyara Dist.Tapi.
314621
04 OF 2026-27
Open
Civil Works - Buildings
Tapi
18 documents required · 16 mandatory · 2 optional
₹6,000
Executive Engineer,Tapi (R & B) Division,Vyara
₹4.2 L
16 Jun 2026
16 Jun 2026
16 Jun 2026
2 Jul 2026
16 Jun 2026
No figures
1 Excavation for foundation upto 1.50 mt depth including sorting out and stacking of 615.70 Cumt 120.01
useful materials and disposing the excavated stuff upto 50 mt lead (A) Loose or soft soil.
2 Excavation for foundation 1.50 mt to 3.00 mt depth including sorting out and stacking of 246.40 Cumt 166.44
useful materials and disposing the excavated stuff upto 50 mt lead (B) Dense or hard soil
3 Filling in foundation and plinth with sand in layers of 20 cm. Thickness including 360.50 Cumt 471.69
watering ramming and consolidating etc. comp.
4 Filling available excavated Earth (Excluding Rock) in trench plinth side of foundation . in 529.42 Cumt 133.65
layer not excluding 20 cm in depth consolidation each deposited layer by ramming and
watering etc. complete
including ramming watering and consolidating etc. complete
6 Anti-Termite System:Providing and laying of permanent piping technology anti-termite 1768.10 Sqmt 63.63
treatment before flooring work by installing LLDP (Low linear density polyethylene) tube
of 8 mm O.D. & 6.4 mm 1.D. with inbuilt pressure compensation chip every 30 cm interval
in the tube, having working pressure of 2 Kg/cm2 and release rate of 1.9 Itr/hour fixed by
P-clips and nails. The LLDP pipe shall be installed at the entire periphery of the building
and at internal network of building at a depth of 20 to 200 mm under floor at every 2 to
mtr. c/c distance (adjusted as per building layout ) & Ends of loop pass through a PVC
elbow of minimum 32 mm ID at junction box of wall and floor level, entering into a steel
reinforced grooved flexible pipe of minimum 22 mm ID leading into junction box and the
loops shall terminate in junction boxes & test every junction during injecting chemicals
for termite control treatment. The anti termite chemical Imidacloprid 30.5% SC mix as
per IS-6313 (part III) shall be injected by the pressure pump diluted with water @
ml/5 ltr of water at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The contractor shall submit
approved line plan for piping system and junction boxes dully approved by Engineer-in-
Charge with bond of 5 year warranty.(II)Anti Termite chemical injected area (Chemical
injecting incl. labour cost)
7 Providing and laying controlled cement concrete M.150 and curing complete including 335.50 Cumt 4007.51
the cost of formwork and excluding reinforcement for reinforced concrete work in (A)
Foundations and plinth pcc
8 Providing and laying controlled cement concrete M.250 and curing complete including 610.10 Cumt 4712.66
the cost of formwork and excluding reinforcement for reinforced concrete work in (A)
Foundations, footings, and Mass concrete.
9 Providing and laying controlled cement concrete M-250 and curing complete including 44.10 Cumt 7641.66
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in (d) columns Up to Plinth level.
Item Rate In
Description of Item Quantity Unit Amount
No figures
10 Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- machine cut 203.90 Cumt 3080.90
stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in
(A) Foundation and Plinth
11 Providing and laying controlled cement concrete M-200 and curing complete including 72.10 Cumt 7633.58
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts G.FLOOR
12 Providing and laying controlled cement concrete M-200 and curing complete including 54.70 Cumt 7633.58
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts F.FLOOR
13 Providing and laying controlled cement concrete M-250 and curing complete including 184.40 Cumt 6077.17
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Ground & Plinth BEAMS
14 Providing and laying trimix flooring of 200mm thick controlled cement concrete M-200 1745.10 sqmt 997.88
and curing complete excluding the cost of form work but including the cost of
reinforcement for reinforced concrete work in FLOORING SLABS including Compaction
and finishing of cement concrete surface by trimix process inclusive of labour charges for
the trimix vacuum dewatering process on cement concrete surface by using vacuum
dewatering pump, surface floater, surface vibrator including Channelling & making
grooves and rough finish to surface by providing expansion Joints, Contraction joints &
construction joints with filling of joints with asphalt filler as directed by Engineer In
charge & as per specification.
15 Providing and laying controlled cement concrete M.200 and curing complete including 71.60 Cumt 6303.41
the cost of formwork and excluding reinforcement for reinforced concrete work in (C)
Ground floor Beams,
16 Providing and laying controlled cement concrete M-200 and curing etc. complete 20.60 Cumt 6903.35
including the cost of form work and reinforcement for reinforced concrete work in (c)
Chhajja for Ground+First floor
17 Providing and laying controlled cement concrete M-200 and curing etc. complete 3.20 Cumt 6943.75
including the cost of form work and reinforcement for reinforced concrete work in (c)
Lintal for Ground floor
18 Providing and laying controlled cement concrete M-200 and curing etc. complete 5.60 Cumt 7181.10
including the cost of form work and excluding the cost of reinforcement etc. complete in
(E) Stair case up to floor two level for Ground Floor
19 Providing and laying controlled cement concrete M-200 and curing etc. complete 14.40 Cumt 5685.29
including the cost of form work and excluding the cost of reinforcement etc. complete in
RCC Vertical and horizontal fins for Ground floor
20 Providing and laying controlled cement concrete M-200 and curing etc. complete 15.30 Cumt 5685.29
including the cost of form work and excluding the cost of reinforcement etc. complete in
RCC Vertical and horizontal fins for First floor
21 Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and 215916.50 Kg 77.29
placing in position complete upto floor two level
Item Rate In
Description of Item Quantity Unit Amount
No figures
22 Brick work using common burnt clay building bricks having crushing strength not less 140.30 Cumt 4153.07
than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine
sand)(B) Conventional
23 Brick work using common burnt clay building bricks having crushing strength not less 217.00 Cumt 4434.92
than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine
sand)(B) Conventional for GF+FF
24 Providing 15mm thick cement plaster in single coat on Rough (Similar) side of single or 1213.60 Sqmt 203.13
half birck walls / concrete wall for interior plastering and finished even and smooth in C
M 1:4 (1 cement : 4 coarse sand) with finished with trove lincluding scaffolding curing etc.
complete. For Ground floor
25 Providing 15mm thick cement plaster in single coat on Rough (Similar) side of single or 369.90 Sqmt 203.13
half birck walls / concrete wall for interior plastering and finished even and smooth in C
M 1:4 (1 cement : 4 coarse sand) with finished with trove lincluding scaffolding curing etc.
complete.. For first floor
26 Providing 10 mm. Thick Mala cement plaster in single coat for plastering on ceiling and 155.70 Sqmt 204.63
soffits of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement :
sand) with finished with trove lincluding scaffolding curing etc. complete. Ground Floor
27 Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and soffits 253.80 Sqmt 204.63
of stairs and finished even and smooth in : (I) Cement mortar 1:4 (1 cement : 4 sand)
with finished with trove lincluding scaffolding curing etc. complete. First Floor
28 20 mm Thick sand faced cement plaster on walls upto all height above ground level 2055.20 Sqmt 337.52
consisting of 12 mm Thick backing coat of c.m. 1:3 (1 cement : 3 sand) and 8 mm Thick
finishing coat of c.m. 1:1 (1 cement : 1 sand) with 1x1cm Groves at juction of structure
member etc. comp.etc. complete.
29 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 125.60 Rmt 43.22
30 White washing with lime on wall surfaces (three coats) to give an even shade including 1583.50 Sqmt 18.59
thoroughly brooming the surface to remove all dirt, dust, mortar drops and other foreign
31 White washing with lime on ceiling surface and/or sloping roofs (three coats) to give an 409.50 Sqmt 19.75
even shade including thoroughly brooming the surface to remove all dirt, dust, mortar
drops and other foreign matter.
32 Finishing wall with water proofing cement paint of approved brand and manufacture and 2055.20 Sqmt 91.82
of required shade on wall surface (three coats) to give an even shade after thoroughly
brushing the surface to remove all dirt, and remains of loose powdered materials
33 Providinfg and fixing 16mm dia MS bar grills of required pattern for windows/ Door 900.00 kg 130.29
using 16mm dia M.S angle/ M.S pipe, M.S flats and other structural steel at required
spacing with galvanized wire jali 20mm x 20mm including cutting, welding and fabriction
etc. including one coat of primer of approved quality and two coats of oil painting as per
detail drawing etc complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
34 Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths 50.00 Sqmt 3555.04
inter-locked together through their entire length and jointed together at the ends by end
locks mounted on specially designed pipe shaft with bracket plates, guide channels and
arragements for inside and outside locking with push-pull operation including the cost of
hood cover and spring etc. complete. (B) Shutters having width 3.5 M. and above
35 P & L 60x60cm Hand Dressed Mirror polished Blue Kota Stone slab 30 mm thick flooring 1740.90 Sqmt 1084.30
over 20 mm (average)thick base of cement mortar 1:6 (1-cement 6-coarse sand) or L.M
1:1.5 (1 Lime putty : 1.5 coarse sand laid over and jointed with grey cement slurry mixed
with pigment to match the shade of slab including rubbing and polishing etc.complete(30
36 P & L 41x57cm Hand Dressed Mirror polished Blue Kota Stone slab 30 mm thick in riser 81.70 Sqmt 1103.87
of steps,skirting dedo and pillars laid on 10 mm thick cement mortar 1:3 (1-cement 3-
coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade
of slab including rubbing and polishing etc.complete(30 mm thick)
37 Providing Plinth Protection to Building including excavation in ordinary soil and laying 253.70 Sqmt 2158.37
cement concrete 1:3:6 using stone aggregates of 40mm nominal size in foundation layer
100 mm thick below pre-cast Rubber Dye inter locking concrete block 60mm thick with
grade of concrete M200 pneumatic compressed by mechanically pressed and as per
approved design including 75mm Sand layer for levelling and filling the joint with sand
in proper line and level etc. complete, Including Providing and fixing pre-cast concrete
kerb stone of grey cement based concrete block 30cm length, 30cm height and 15cm thick
of M250 grade concrete as per approved design and including excavation for fixing in
proper line and level, filling the joint with C:M 1:3 (1cement:3 fine sand) etc. complete.
38 Providing and laying broken chine mosaic flooring for terrace using 12 mm to 20 mm 298.10 Sqmt 1124.69
broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out upto surface using white cement including rounding
off junctions and extending them upto 15 cm along the wall,clearing with water and oxalic
acid etc. as directed. and Providing and laying cement concrete flooring 1:2:4 (1- cement :
2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid in one layer and
finished with a floating coat of neat cement. (B) 50mm thick.
39 Providing and fixing polished 18 mm thick Granite stone with full round edge and 71.70 Sqmt 1701.85
polished of approved quality in clading on sill and around the doors/ windows/
ventilation with 20 mm thick cement plaster CM (1:4) and fixing with cement slurry &
adhesive including moulding of exposed edges as directed by engineering in charge etc.
Item Rate In
Description of Item Quantity Unit Amount
No figures
40 Constructing brick masonry chamber for underground C.I. Inspection chamber and bends 10.00 No 3208.77
with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 precast RCC
cover 455mm x 610mm intenal dimensions with frame (R.C.C. top slabe with 1:2:4 mix (1-
cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10
inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed concrete etc. complete (i) Inside dimensions 455mmx
610mm and 450mm deep for single pipe line.
41 Constructing brick masonry chamber for underground C.I. Inspection chamber and bends 8.00 No 3916.78
with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame
to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe
with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i)
Inside dimensions 500mmx 700mm and 450mm deep for single pipe line.
42 Extra over items for every additional depth of 0.1M. of part thereof beyond 450mm depth 10.00 Each 242.39
for Brick masonry chamber.(i) for 455mm x 610mm size.
43 Extra over items for every additional depth of 0.1M. of part thereof beyond 450mm depth 8.00 Each 264.86
for Brick masonry chamber.(i) for 500mm x 700mm size.
44 Providing cement vata (10cm x 10cm size) quarter round in cement mortar 1:1 including 91.40 Rmt 24.28
neat cement finishing watering etc. Complete
45 Providing and fixing in position 150 mm high, English letters made from 1.0 mm thick 30.00 No 282.80
stainless steel sheet as directed by Engineer in charge with all necessary tools & plants
etc. complete.
46 Providing and fixing Germany glass brick German size 19 x 19 x 10 cm is opening and 68.00 Sqmt 2934.05
fixed with white cement and boundary adhesive as per design and sealing the joints with
silicon structural sealant SSG-4000 including all labour cost etc complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
47 Providing and fixing approved quality prefabricated 0.80 mm thick colour coated 1023.00 Sqmt 1969.50
GALVALUME self-supporting roofing system, 100% leak proof, of Proflex / Steel Craft or
equivalent make approved by GSCSC Ltd., at height up to 10.0 m from base level, with
proper perfect curve geometry, true to line and level, including placing and fixing
complete, for Bay-3 (SPAN/5) having span 23.00 m, arch rise 4.60 m, arch length 26.78 m,
length 42.00 m, height 6.00 m, , including on-site manufacturing and simultaneous
installation facility, necessary roll forming, fabrication, seaming, all civil works, steel
works, fabrication works, erection, supply and fixing of hangers, clamps, fasteners and
accessories, complete in all respects, including providing and fixing turbo ventilators at
approved locations with proper cut-outs and all required sealants of GE / Wacker or
approved equivalent for complete waterproofing; the contractor shall submit detailed
specifications, structural design data, test certificates and drawings prior to
commencement of work, carry out minimum three (3) metallurgical tests, fabricate,
corrugate, lift, place, erect and fix the roofing sheets at site at any height with excellent
workmanship, the colour of sheets shall be as approved by the Architect, and the
contractor shall provide 3 years guarantee, performance bond and maintenance for the
prefabricated self-supporting roofing system without any extra cost, complete as per
directions and to the full satisfaction of the Engineer-in-Charge, including Imported
Galvalume material having BMT 0.80 mm (APT 0.85 mm) or BMT 1.10 mm (APT 1.15 mm)
with thickness tolerance ±0.02 mm and coil width 912 mm with tolerance ±4 mm
48 Providing and fixing Turbo ventilators on the top of the self supported steel roof at the 14.00 No 10150.50
prescribed location as per the design and drawing, made out of high grade aluminium of
brand everflow and equivalent. The turbo ventilators are to be fixed by using the housing
made of polycarbonate of reputed brand and sealants of GE , Wreckers so there entire
joinery with the roof . The rate is water proof. The rate is inclusive of all tools, tackles,
fabrication, wastage and necessary civil work and everything to complete the work in
perfect manner.
49 Extra for additional height of propping and centering where the height of propping and 1576.10 Sqmt 706.05
centering exceeds 4 .O M between supporting floor to ceiling including temporary brick or
stone pillars for supporting as required. (ii) Height more than 5.0 M.and upto 6.0 M.
50 Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) 112.00 Rmt 857.65
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe
line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at
every 2000 mm center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all materials.
Item Rate In
Description of Item Quantity Unit Amount
No figures
51 Providing and fixing the approved quality prefabricated 0.80 mm thick colour coated 747.00 Sqmt 1666.50
GALVALUME self-supporting 100% leak proof roof of proflex, steel craft or equivalent
quality approved by GSCSC LTD at the height up to 10 MT base level with proper perfect
curve geometry in line and level and placing and fixing. The prefabricated self-supporting
roofing includes on site manufacturing & simultaneous installation facility, necessary roll
farming, fabrication , seaming civil work, steel work, fabrication , erection , hangers
clamps, the contractor has to fix turbo ventilators at desired location having perfect cut
outs on the roof with all necessary sealants of GE OR wrecker for complete water
proofing. the contractor must provide all the detail specification , structural data, test
certificate & drawing of the roofing system prior to commencement of work. the roofing
shall be fabricate, corrugated , lifted, placed , erected, fixed at specific location up to any
height at site and work shall be completed in excellent workmanship up to satisfaction of
engineer in charge . The colour should be as per approved shed by architect. The
contractor shall provide minimum 3 metallurgical test before commencement of work.
The contractor has to give 3 years guaranty performance bond and maintenance for
prefabricated roofing system without any extra cost. Including IMPORTED GALVALUME
Material having BMT: 0.8mm, APT: 0.85 mm, Tolerance : +/- 0.02 MM, Coil Width:
mm, Tolerance: +/- 4 mm.
52 Box cutting the road surface to proper slope and camber for making a base for road work 1279.00 Cum. 106.65
including removing the excavated stuff and depositing on the road side slope as directed
upto 50Mt.lead.
53 Filling in plinth with sand under floors including watering ramming, consolidating and 270.00 Cum. 434.30
dressing complete for road work
54 Construction of granular sub-base 150 mm thick by providing coarse graded machine 445.00 Cum. 904.96
crushed B.T. material satisfying MOST specification of grading I (B.T. stone aggregate
mm to 26.5 mm 35 %, 26.5 to 4.75 mm - 45 % and 2.36 mm below - 20 % )including
spreading in uniform layer with motor grader on prepared surface, mixing by mix in place
method with rotavator at OMC and compacting with vibratory roller to achieve the
desired density etc. complete.
55 Providing and laying wet mix macadam base course 250 mm thick using machine crushed 539.00 Cum. 1170.59
B.T. chips as per required gradation mixing with required optimum quantity of water,
conveying the mix to site of work, spreading in to grade and camber with mechanical
paver and consolidation each layer with vibratory roller including cost of material labour
plant and equipment etc. complete.
56 Compaction and finishing of cement concrete road by trimix M.250 process providing 2691.00 Sqm. 63.63
extra Labour charges for the trimix vacume dewatering service process on cement
concrete road sutface by using vacuum dewatering pump floater surface vibrator
including making groves and rough finish to surface including leveling etc complete.
57 Providing and fixing pre-cast Rubber Dye inter locking concrete block 60mm thick with 260.00 Sqm 704.07
grade of concrete M30 pnumatic compressed by mechanically pressed and as per
approved design confirming to IS 15658: 2006 including 35mm Sand layer for levelling
and filling the joint with sand in proper line and level as per guidelines of IRC SP 63-2018
etc complete.
Item Rate In
Description of Item Quantity Unit Amount
No figures
58 Providing and Laying homoginious Grey cement based concrete kerbing of size 30 cm x 520.00 Rmt. 370.68
30 cm x 10 cm size as per detailed drawing having grade of concrete M25 grade, including
necessary excavation, BBCC 1:5:10 7.5 cm as per ddetailed drawing fixing in line and
level, filling joints in CM 1:3 with smooth finished, white washing three coats etc.
complete as directed by Engineer in charge.
59 Providing laying (to level or slopes) and jointing reinforced concrete Light duty non- 174.00 Rmt. 678.01
pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends
prepared for collar joints including testing of joints complete.(D)
60 Drilling of min. 250 mm dia. bore hole in all strata including dualover burden strata by 50.00 Rmt 865.57
combination DR/DTH rig including lowering 200 mm dia MS ERW pipes in bore hole and
testing etc.all work as per directed engineer incharge.
61 Manufacture, supply and delivery of cage typeTrapezoidal shape ( ' V ') wire wound low 50.00 Rmt 1682.66
carbon, Galvanized screen pipe and Stainless Steel Screen pipes, confirming IS: 8110 For
(B) 200mm dia 1) 1.00mm Slot size
62 Bore plug having 100 mm height made from M.S. plate with 3 holes at equal distance on 1.00 No. 1161.62
circumference for nut-bolts type, locking arrangement with nuts-bolts & lock nuts of std.
Make complete. For 250mm dia
63 Providing PVC insulated flat submersible cable as per detailed technical specifications of 50.00 Rmt 121.20
R/C of GWSSB conforming to IS 694, IEC 60227 / 60228.d)1 R x 3 C x 6.0 mm2
64 Suppling and installing 3 Phase Borewell 3.0 HP Submersible Pump Sets Electric motor 1.00 Set 37130.63
driven conforming to I.S. 8034 and motor conforms to IS-9283 working at 3 phase
400/440 volt 50 C/S A.C. supply & 2900 R.P.M. cat
65 Providing and fixing check or non return pully wheel valve of 50 mm diameter. 1.00 No. 1111.00
66 Manufacture, supply and delivery of following ISI marked HDPE pipes (IS:4984/1985 45.00 Rmt 152.51
with latest amendment) having material Grade PE-80 in approximate 100 meter coil
length or as per GWSSB requirement with SS 316 nipple at both ends having 11 TPI
threads as per specifications, press fitted and bolted having nominal diameter as under as
per detailed technical specifications.
67 Providing following type of Modular Type Accessories mounted with PVC / 36.00 Nos. 410.06
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site
situation directed by Engineer In charge.(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole
Modular MCB SwitchCatIII
68 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete 985.30 Mtr. 33.33
to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as
directed (b) 25 mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
69 Providing & Erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded 240.00 Mtr. 62.62
Copper conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity in existing pipe With 2 wire 2.5 sq. mm
70 Providing Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper 70.00 Mtr. 121.20
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (e) in existing pipe (b) 2 wire 6sq. mm
71 Providing Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper 754.00 Mtr. 86.86
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (e) in existing pipe (a) 2 wire 4 sq. mm
72 Supplying and erecting LED street light / Flood light fittings with High power White LEDs 20.00 Nos. 3345.12
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of
between the ranges shown.) ((A) Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage protection. (i) above 36 to
wattsCatIII
73 Supplying and erecting LED street light / Flood light fittings with High power White LEDs 36.00 0.00 7266.95
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of
between the ranges shown.) (B) Flood Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage protection. 100 to 120 watts CatIII
Item Rate In
Description of Item Quantity Unit Amount
No figures
74 Supplying and erecting LED street light / Flood light fittings with High power White LEDs 4.00 Nos. 4092.52
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of
between the ranges shown.) (C) Post Top Lantern LED fitting comprises of finish cast
aluminum spigot and spun aluminum canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and accessories wired upto terminal block.IP
65(i)20- 30WCat-lll
75 Providing & erecting Switch board for Computer or electric apparatus consisting of 8.00 Nos. 1133.22
following modular type accessories mounted with PVC / Metallic concealed/open box
with single mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type AccessoriesCat. III
76 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate 20.00 Nos. 112.11
on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI MarkCatIII
77 Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 10.00 Nos. 295.93
KA breaking capacity & confirms to IS : 8828 in exist (B) 40 Amp. Cat.III
78 Replacing Old & us Switches by Providing & erecting 415V MCB Four Pole Switch for 4.00 Nos. 638.32
Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing
box having following capacity (b)40 Amp. Cat-III
79 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / 2.00 Nos. 1492.78
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing(b) sheet steel double door (IP-43)(iv)12
80 Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB. 4.00 Nos. 176.75
81 providing and erecting Approved make RCCBs conforming to IS: 12640 and having 2.00 Nos. 2235.13
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed (ii) 40Amps. DP Cat III
Item Rate In
Description of Item Quantity Unit Amount
No figures
82 Pipe type earthing having 150 cms.long and 2.5 cms. dia. galvanised iron pipe with 4.00 Nos. 368.65
coupling and buch buried in specially prepared earth pit complete with necessary 8 SWG
earth wire.
83 For using salt and charcoal / coke as required for pipe type earthing. 4.00 Nos. 171.70
84 Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing 6.00 Nos. 4591.46
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of
12mm with constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test certificate including value of
earth resistance of installation duly stamped and signed by agency and officer Incharge
has to ensure the value of earthing resistane mentioned in test Certificate) & having back
filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar
content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted by Agency. (a) For
Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.. [3-14-9]
85 Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity 40 1.00 Nos. 49559.69
Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by 15˚
C within a hour, The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded by evaporating coil,
thermostats, relay etc. complete with necessary inlet & outlet connection. The body of
water cooler will be made from Stainless Steel.
86 Supplying & erecting reverse osmosis (RO) water purification system with M.S. powder 1.00 Ea. 77891.20
coated pedestal frame, prefilter housing carbon filter suitable buster DC pump, auto low &
high pressure switches with following size of LPH capacity & erected as directed [D]
LPH with 1 phase / 3 phase Raw water pump of 500LPH @ 2.5kg/cm2 - (1N0 - Kirloskar
/CRI/Lubi), Dual media filter 10"x54" - (1 No), Micron cartridge filter 20" x 2.5" ( 1No),
High pressure pump 500LPH @ 10kg/cm2 - (1No - Shimge /CRI /Lubi), RO Membrane
housing with RO membrane of 40*40 - (1No), RO pressure tube 4" x 1E - ( 1No), 0 -
1200LPH Rotameter -(2 Nos), with Recovery Rate 50%.
87 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 2.00 Nos. 38.38
insulated armoured cable complete with out going tails, insulating tape etc for following
size of cables. (c) 2 to 4 core 6Sq. mm
88 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 2.00 Nos. 38.38
insulated armoured cable complete with out going tails, insulating tape etc for following
size of cables. (C) 2 to 4 core 10 Sq. mm
Item Rate In
Description of Item Quantity Unit Amount
No figures
89 Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following 8.00 Nos. 6.06
size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.
90 Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following 8.00 Nos. 13.13
size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (B) 10 Sq.mm
91 Providing Street light pole bracket consisting of" B" Class MS .pipe of 4.2 cms. outside 12.00 Nos. 450.46
dia.complete with suitable MS sleeve tubing of required size and length suitable for
76.5mm/80mm/require size of pole top having nuts and bolts for fixing the brackets and
having spread of 0.5 mtr. Length with 110 deg.with vertical plane and suitable welded
stiffener reducer and nipple with checknut complete painted with one coat.of Red oxide /
PU base primer and two coats of Aluminium / PU paint. paint with following nos of
arms.[A] Single Arm bracket 0.5 Mtr
92 Providing Street light pole bracket consisting of" B" Class MS .pipe of 4.2 cms. outside 4.00 Nos. 569.64
dia.complete with suitable MS sleeve tubing of required size and length suitable for
76.5mm/80mm/require size of pole top having nuts and bolts for fixing the brackets and
having spread of 0.5 mtr. Length with 110 deg.with vertical plane and suitable welded
stiffener reducer and nipple with checknut complete painted with one coat.of Red oxide /
PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.
(B). with Double Arm Bracket 0.5 Mtr
93 Supplying & erecting approved make IP 55 grade Company fabricated Timer Panel of 3.00 Nos. 13350.18
following capacity for switch On-Off street lights on time scheduling basis made from 16G
CRCA sheet duly epoxy power painted inside and outside with hinged doors and locking
arrangement consisting of suitable size of 4 Pole MCB and 4 pole contactor (cat-III)with
analog time switch, auto manual switch of same make and suitable input and output
Bakelite terminals and with door earthing approved by Engineer in charge.(B) 40 Amp
94 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 40.00 Kg 794.87
95 Providing & laying approved make Double walled corrugated pipes (DWC) of 734.40 Mtr. 62.62
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same
material at required depth for laying of cable. below ground / road surface for enclosing
cable and back filling the same to make ground as per original.(a)50 mm dia.
96 Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to e erected at 30.00 Mtr. 69.69
road crossing on or floor as directed for laying of cable. The pipes as following size of dia
& weight per 6 mtr. (a). 50 mm Dia. (2.5Kg/6RMT).
97 Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to e erected at 20.00 Mtr. 171.70
road crossing on or floor as directed for laying of cable. The pipes as following size of dia
& weight per 6 mtr. (b). 90 mm Dia (8.0 Kg / 6RMT).
Item Rate In
Description of Item Quantity Unit Amount
No figures
98 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The 16.00 Nos. 6874.06
pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by manufacturer considering site
requirement(C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M16 Bolts and 600mm long with necessary G.I. J
Bolts .Approx Pole weight 46 kg
99 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to 192.00 Mtr. 137.36
be erected as directed With 3 core 2.5 Sq. mm size.
100 Providing and erecting Approved make Four pole moulded case circuit breaker having 3.00 Nos. 6173.12
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.
housing.ICS=100% of ICU only Cat III
101 Supplying & erecting approved make Four Pole 415V change over switch interior for 1.00 Nos. 7790.13
panel mounting with operating mechanism A.C.23 duty confirming to IS for (C)100-125A
102 Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium 1.00 Nos. 660.54
Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. /
sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for
phase sequence of following current carrying capacity, erected with necessary bus bar
supports /insulators, main cable socket to each busbar,erected in existing cubical panel
with necessary connections.(A) Suitable for 100 Amp. Capacity
103 Providing & erecting weather proof, dust & vermin proof, floor mounted front operated 4.00 SqMtr 10468.65
indoor type cubical panel board necessary IP-42 and above protection as per approval
from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors,
16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for
measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with locking arrangement and rubber
gasket,heavy duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted with epoxy powder
(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base
beams) The panel shall be supplied with following approved manufacturers with
following size.(A) locally fabricated panel board(i) with 350 mm depth
104 Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 2.00 Nos. 1275.63
digits LED display, 0 to 750 AC Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration certificate.
Item Rate In
Description of Item Quantity Unit Amount
No figures
105 Supplying and erecting approved make panel mounting type Digital Ammeter having 3 2.00 Nos. 1558.43
digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to
operate on 500 Volt AC , erected on existing panel board with all connection, wiring etc
.with manufacturers calibration certificate
V on existing panel board with necessary connections.
107 Supplying and erecting approved make suitable panel indicator LED type lamp, lens 6.00 Nos. 43.43
cover, complete erected with necessary connections.
108 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid 200.00 Mtr. 140.39
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (C) 4 core 10 Sq. mm
109 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid 616.00 Mtr. 126.25
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (B) 4 core 6 Sq. mm
110 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the 734.40 Mtr. 55.55
fault all over the run and back filling the same and making the surface as normal ground.
111 Supplying and erecting approved make double ball bearing oscillating type Heavy duty 16.00 Nos. 6438.75
bracket fan with Aluminium Blades A.C. 23OV. 50cy/s wall mounted with height
adjustment and rotary tilting device complete with guard, wall bracket,mounting
accessories as directed.(B) 600mm
Total Rs.
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and words) of the estimated rate mentioned
above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
Item Rate In
Description of Item Quantity Unit Amount
No figures
The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra
1 payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C
Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost of difference of cement
4 consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Executive Engineer
Tapi ( R & B ) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
FINAL GODOWN SBD_11zon.pdf
BOQ-godown.pdf
SPECIFICATION-godown.pdf
4 Building-Specification Booklet (2 side).pdf
1.0 GRs - SBD with Index (2 side).pdf
exxtrs exss gr.pdf
4.0 Specification (Electrical Work)_11zon.pdf
Electri-Special condion Godow.pdf
3.0 NOMINATED ELECTRICAL SUB CONTRACTORS (2).pdf
5.0 Approved make list 2013 2014 Part 1.pdf
6.0 Approved make list 2013 2014 Part 2.pdf
Electri-Techanical specification.pdf
Download all tender documents and submit your bid