| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 CrAdmitted-Finance | ₹26.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹30.0 CrAdmitted-Finance | ₹30.0 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Two class below the eligible class |
| Sl No | Description | Qty | Unit | Kurian And Varghese L1 | CREATIVE BUILDERS L2 |
|---|---|---|---|---|---|
| 1.00LIST OF WORKS | |||||
| 2.00Schedule A Part I( to Part IX) | |||||
| 3.00 | Total amount of Sch 'A' Part-I (Buildings & Structures) | 1 | Lumpsum | 4,02,60,000 ₹4.0 Cr | 6,29,99,999 ₹6.3 Cr |
| 4.00 | Total amount of Sch 'A' Part-II ( Excavation, Earth work and Site clearence) | 1 | Lumpsum | 41,95,592 ₹42.0 L | 35,99,999 ₹36.0 L |
| 5.00 | Total amount of Sch 'A' Part-III (Internal Water Supply) | 1 | Lumpsum | 64,609 ₹64,609 | 84,999 ₹84,999 |
| 6.00 | Total amount of Sch 'A' Part-IV (Internal Electric Supply) | 1 | Lumpsum | 1,87,838 ₹1.9 L | 1,56,999 ₹1.6 L |
| 7.00 | Total amount of Sch 'A' Part-V (Road/Path/Hardstanding) | 1 | Lumpsum | 27,58,000 ₹27.6 L | 34,99,999 ₹35.0 L |
| 8.00 | Total amount of Sch 'A' Part-VI(Sewage Disposal) | 1 | Lumpsum | 2,75,000 ₹2.8 L | 2,38,999 ₹2.4 L |
| 9.00 | Total amount of Sch 'A' part-VII (Area Drainage) | 1 | Lumpsum | 13,18,785 ₹13.2 L | 13,99,999 ₹14.0 L |
| 10.00 | Total amount of Sch 'A' part-VIII (Retaining wall/Compound wall) | 1 | Lumpsum | 9,05,785 ₹9.1 L | 10,99,999 ₹11.0 L |
Tender Value
₹20 Cr
EMD Value
₹15 L
Closing Date
18 Nov 2022, 6:00 pmClosed
CE NW Kochi
CE (NW) Kochi
ROVISION OF 25M SWIMMING POOL AT NAVAL STATION KOCHI
2022_MES_542652_2
891008
Open Tender
Civil Works
900 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) NW Kochi
₹15 L
9 Dec 2022
14 Oct 2022
21 Nov 2022
15 Oct 2022
18 Nov 2022
4 Nov 2022
15 Oct 2022 - 2 Nov 2022
Amount
LIST OF WORKS
Schedule A Part I( to Part IX)
Total amount of Sch 'A' Part-I (Buildings & Structures)
Total amount of Sch 'A' Part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' Part-III (Internal Water Supply)
Total amount of Sch 'A' Part-IV (Internal Electric Supply)
Total amount of Sch 'A' Part-V (Road/Path/Hardstanding)
Total amount of Sch 'A' Part-VI(Sewage Disposal)
Total amount of Sch 'A' part-VII (Area Drainage)
Total amount of Sch 'A' part-VIII (Retaining wall/Compound wall)
Sch 'A' Part- IX(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 800mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 700mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Material and labour for RCC with ready mix concrete(RMC) M30 grade in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Material and labour for RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drawing. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Material and labour for TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drawings including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Material and labour for TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on deawings including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Material and labour for TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 12mm dia as in stirups for pile caps and gared beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
All as per item No 20 above but 5mm dia and over up to & including 12 mm dia as in helicals of pile reinforcement including rings and necessary tack welding to pile reinforcement at all points of contacts.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 800mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 700mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 800mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 700mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
All as per Item No 31 herein before but exceeding 1.5m and not exc 3m
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance exceeding 1.5Km and not exceeding 5km deposited whereever dircted at a level not exc 1.5 m above starting point .
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
INTERNAL ELECTRIFICATION: Material and labour for Point wiring using approved colour coding as per IS with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for One light/Ceiling Fan/exhaust fan point controlled by one 5/6 amps one way switch. .(NOTE: Switch and socket to be measured and paid for separately).
All as per Item No 36 herein before but One modular Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps switch one way
All as per Item No 36 herein before but One light point controlled by two switches 5/6 amps two way.
All as per Item No 33 herein before but One modular Socket outlet, three/five pin, 5 Amp, controlled by one 5/6 amps one way switch on same board with other switches
Material and labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI marked including heavy duty, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent .(NOTE: Switch and socket to be measured and paid for separately).
Supply and fix Ceiling fan 1200mm sweep copper wound having minimum service value of 6.00, BEE five star rated with brushless DC(BLDC) motor and min air delivery 210CFM including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan complete all as specified and directed by Engr-in-Charge
Supply and fix Exhaust fan Steel body, 300 mm sweep 230 Volts AC 50 Hz, with blades, frame and louvers, including connecting up from ceiling rose with 3 core flexible copper cable, PVC sheathed of size 1.5 sqmm complete all as specified and directed by Engr-in-Charge
Supply and fix Exhaust fan made of sturdy engineering plastic complete, with louvres, copper wound of sweep 250 mm 230 Volts AC 50 Hz, , including connecting up from ceiling rose with 3 core flexible copper cable, PVC sheathed of size 1.5 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED lights fitting 1x 12W, 220V, round shape with high efficiency diffuser, soft glare free light complete, suitable for ceiling fitting, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeg all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete fixed as building security light on walls with suitable size GI pipe bracket, bent to shape up to 1.5 m long, including connecting up from junction box/ ceiling rose with twin core weather proof copper cable, I.5 sqmm complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Air circulator fans industrial heavy duty wall mounted ,100W, single phase, oscillating, 450mm sweep 1440 RPM, air delivery not less than 150m³/min suitable for wall mounting with and including wall mounting arrangements suitable to mount on steel/ Wall surfaces all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED Flood light fitting 1x80W luminaires with ultra sleek, light weight and secondary optics, made of pressure die cast housings with 1P 66 ingress protection and impact resistance of IK 07, 4KV inbuilt and 10KV extenal surge protection, including connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED High bay Light fitting, 100W,extra efficient having lumen out put 150Lm/W, with elliptical design, modular lens optics for optimised light distribution to improve operational efficiency, with EMC/EMI compliant plotted driver all as specified and as directed by the Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0Sqmm 2 core(For high bay lights) all as specified and as directed by the Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16Sqmm 4 core from main building DB complete all as specified and as directed by the Engineer-in-Charge.
INTERNAL WATER SUPPLY:-Supply and fixStop cock angular 15mm bore with wall flange complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Bib cock with wall flange complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Helth faucet/hand shower with 8mm dia wall hook and easy flexible tube in chrome finish 1.5m long with nuts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over head shower rose of PTMT any colour for fixing with 15mm pipe with shower arm 15mm size 195m long with 45 degree with flange PTMT complete all as specified and as directed by the Engineer-in-Charge.
SEWAGE DISPOSAL:-Matrial and labour for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 type D2 below foundation, RCC M-30 design mix in walls, base slab, baffle walls and Roof slab incl. beams etc with vent shaft manhole openings with cover connection etc., with effective depth of 1.50m and over all depth of 3m for 50 users complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 m dia x 3 m effective depth complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay DWCPE pipe 163mm internal diameter laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
RETAINING WALL/COMPOUND WALL:-Matrial and labour for Design Mix M30 as per IS- 456 with using 20mm graded stone aggregate for , retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for RCC M30 design mix for lintels/beam over 1.5 Mtr span complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for RCC type B1 (1:2:4) using 20 mm grade aggregate for coping complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for RCC type B1 (1:2:4) using 20 mm grade aggregate for Columns complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Formwork to rough finished surfaces flat sides of concrete walls ,retaining wall, abutmemts etc vertical or batter complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for fair finished formwork to face of wall, face and sides of beam/coping complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for TMT bars 10 mm dia nd over cut to length bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No.67 above but for stirrups all as specified and as directed by the Engineer-in-Charge.
Material and labour for Preparation of newly concrete surfaces of wall and applying two coats of antifungal paint over a coat of primer over a coat of external putty all as specified and as directed by the Engineer-in-Charge.
Material and labour for Framed work s in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(Exclusive of steel sheeting or other covering, running rails and guides)and hanging also fastening and fixing complete all as specified and as directed by the Engineer-in-Charge.
EXTERNAL WATER SUPPLY:-Matrial and labour for Cutting of existing Cast Iron pipe line 200 mm in position and inserting Tee of size 200 x 200 x 100 along with fixing of necessary fittings and fixtures such as tail piece expansion /crumble joint including excavation and earth work complete all as specified and as directed by the Engineer-in-Charge.
Supply and Laying of Pipes galvanized, “Medium class”,complete including fittings 100 mm (4”) dia complete all as specified and as directed by the Engineer-in-Charge.
Supply and Laying of Pipes galvanized, “Medium class”, supplied and laid complete including fittings 80 mm (3”) dia all as specified and as directed by the Engineer-in-Charge.
Supply and Laying of Pipes galvanized, “Medium class”, supplied and laid complete including fittings 40 mm (1 1/2”) dia complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Valve, butterfly conforming to IS 13095 supplied and installed complete of size 100 mm (4”) dia all as specified and as directed by the Engineer-in-Charge.
Supply and fix Valve, butterfly conforming to IS 13095 supplied and installed complete of size 80 mm (3”) dia all as specified and as directed by the Engineer-in-Charge.
Supply and fix Valve, butterfly conforming to IS 13095 supplied and installed complete of size 40 mm (1 1/2”) dia all as specified and as directed by the Engineer-in-Charge.
EXTERNAL ELECTRIFICATION: Supply, spreading and levelling riddled soil as earth cushioning to UG cable by using IS seive to seperate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site. Note:- Punned thickness shall be measured and paid.
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm confirming to IS:5039:1983 and duly ISI marked.. all as specified and as directed by the Engineer-in-Charge.
Supply and lay Tubes, 'light grade' 80mm bore, galvanised with all fitting laid in trenches, roads, nalah, road crossing etc all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 240 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 35 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2 core 10 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping . all as specified and as directed by the Engineer-in-Charge.
Supply and fix 4pole MCCB 100 Amps 30 kA with enclousre fabriated out of 2mm hick CRCA sheet dluly powder coated complete with and including making ncessery arrangements/ alteations in existing LT panel board fo fixing for Main supply complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED street light IP66, 115/120W, with single die cast ceramic base, high power LED Source, PDC housing, toughened glass cover, and unique peanut lens to ensure uniform light distribution all as specified and as directed by the Engineer-in-Charge.
Supply and lay Rubber mat confirming to IS 15652/2009, BIS,CPRI and ERDA approved, of dielectric strength 45KV, suitable for AC rms voltage grade 3.3KV-11KV, of size 1 meter x 2 meter x 3 mm all as specified and as directed by the Engineer-in-Charge.
Supply, install, testing and commissioning of factory made and CPRI tested indoor typeLT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 600 Amps for phases and 600 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties( Location LTP No 1 of schematic plan)
INCOMINGS: (a)MCCB 415 Volts,100 Amp rating, 4 Pole Microprocessor based 18 kA 1 No.(b)Digital volt meter 0-500 Volts-01. (c)Digital Ampere meter 0-400 Amps with and including CTs. OUTGOING:-(a )MCCB 63 A 18 kA 4 pole 415 Volts with thermal magnetic relay -03 Nos(Filtration plant of swimming pool and spare) (b)MCB 230 Volts, 16 Amp , rating 2 Pole , 10 kA 50 Hz- 3 Nos(01 No filtration plant room, Street light and spare)(c )Internal wiring of panel with stranded copper cable of suitable size(d)Neon phase indicating lamp(Set of three)-01 Set(e)Stenceling of pannel board including marking of distribuitions
Earthing of machinery/equipment Installed at power house/substation, using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode for LT panel 1 and Filterartion plant starter panel
Supply, install, test and commissioning of Air Blower with suitable 3 Ph motor IE-2 rated , ISI marked required for filtration unit back wash process of suitable capacity but not less than 300 Cum /Hr , or as recommended by OEM for swimming pool all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Water circulation, Horizontal split casing end suction pump 415 V, 50 Hz, 1450 RPM with suitable DOL starter including stater panel complete suitable for pressure filter designed discharge capacity 80 m3 / hour @ 25 Mtr head having pump efficiency 65-75%, and suitable for filtration plant as per Sl No 105 above for ensuring turnover period 5-6.0 hour with suitable capacity prime mover. The pump shall be of cast iron body, bronze impeller, with mechanical seals, TEFC squirrel cage IE-2 induction motor, with M.S. Fabricated base plate, mounting channel frame, accessories and fittings like pressure gauges, Air release valve, drains, coupling, coupling guard etc including PCC foundation, vibration isolation arrangement complete all as specified in the particular specification. (2 working and one stand by) all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of chlorine dosing pump (venturi drive pump) 0 - 6 LPH with PP/PVC dozing tank capacity 150 Ltr - 2 Nos and piping for in let & out let connection complete with control valves, NRV,metering, electric cabling & copper wiring through suitable size PVC concealed conduit from Main control panel to booster pump all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Acid/alkali Dosing pump (venturi drive pump) 0 - 6 LPH with PP/PVC dozing tank capacity 150 Ltr with high speed stirrer and piping for in let & out let connection complete with control valves,NRV,electric cabling & copper wiring through PVC conduit from Main control panel to booster pump all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Pool Hair & lint catcher size -500 MM x 750 MM X 40 MM with mesh & handle made of SS 304 grade all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Trolley mounted suction sweeper with self priming electric driven pump set suitable for cleaning swimming pool capacity ,complete with PVC braided vacuum hose pipe of length minimum 30 Mt, 900 mm size Aluminium / bronze vacuum head, flexible copper cable from Main, PVC floats, wire rope and all connected accessories complete
Supply and fix 18 inch long Nylon brush all as specified and as directed by the Engineer-in-Charge.Make : Ion Exchange India Ltd/Voltas /Eureka Forbes
Supply and fix Telescopic pole 4.8 Mtr long with extendible up 9 Mtr made of aluminium tubing complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Test Kit for PH & Residual chlorine all as specified and as directed by the Engineer-in-Charge.
Supply and fix Leaf rack made out of aluminium frame all as per sample complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Leaf skimmer made out of aluminium frame all as per sample complete all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Pool under water lights, integral LED 20Watt, wall mounted type working on 12 V DC, IP68 complete with built-in driver, including push in connector all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of junction box of suitable size round/square type with water proof covering made of ABS plastic material for under water lights. all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Pool floor inlets (pool jets) 63 mm dia including tail piece of 63 mm dia 20cm long wit pool floor inlets, made out of ABS plastic white colour with SS screws suitable for flow rate of 5000 ltr/hr top of floor tiles provided in bottom of swimming pool all as specified and directed.
Fabricate, Supply install test and commissioning of indoor type panel board & Cabling work for pool under water lights & motors , suitable for 440 Volt, 3 phase & Neutral , 50Hz supply ,IP-42 Deg of protection , floor mounted weather and vermin proof, factory fabricated with 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thickness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel opper lugs for cable terminations complete, with locking arrangements ,duly powder coated with siemens grey colour after chemical treatment ,with suitable ventilation ,including LED RYB indicators ,MCCB's with suitable size PVC insulated(unsheathed)single core multi stranded copper cable, copper bus bars, all internal circuit protection wiring with suitable size FRHR 1100 V grade wiring with 2.5 sqmm and MCB protection with suitable rating and 10 KA breaking capacity,including terminal adapters,spreader links on incoming and out going sides of MCCB's, complete, operations incl Auto manual facility for each bank, with bank ON/OFF indication for each bank incl all internal wiring, CT's , Protection devices, MCBs protection for metering, contactors, indication lamp etc all as specified and directed.
Supply and lay PVC pipe grey in colour 50 mm for dosing system -10kg/cm2 with valves ,NRV ,fittings etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay PVC pipe grey in colour 75 mm for distribution line -10kg/cm2 with valves ,NRV ,fittings etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay PVC pipe grey in colour 100 mm pool floor inlet distribution line -10kg/cm2 with valves ,NRV ,fittings etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay PVC pipe grey in colour 150 mm for pool floor inlet line -10kg/cm2 with valves ,NRV ,fittings etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay PVC pipe grey in colour 200 mm for pump suction & delivery header line -10kg/cm2 with valves ,NRV ,fittings etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay PVC pipe grey in colour 250 mm for over flow system -6kg/cm2 with valves ,NRV ,fittings etc complete all as specified and as directed by the Engineer-in-Charge. Note for Item Nos:- Unit rate quoted shall inclusive of Rates of all fittings & valves of pressure rating 10kg/cm2
Material and labour for Electrical cables for Underwater lights with PVC conduit 2 core ,2.5 sqmm , 4.0 sq mm copper cable with Rigid PVC conduit from junction/deck box to light panel & Cable for Pump with Blower- 4.0 core - 4.0 sq mm , 6.0 sq mm -4.0 core copper cable all as specified and as directed by the Engineer-in-Charge.
Supply install test and commissioning of Factory made Vertical cylindrical type multi grade pressure sand filter capacity minimum 80 m3 / hour made from MS sheet suitable with size 2000 mm dia for working pressure 2.5 Kg/cm2 duly painted (inner & outer) with red oxide primer and two coats of epoxy paint complete with suitable size of inlet, outlet valves,NRVs, control valves for operation, back wash system including valve manifold, drain out facilities complete including frontal piping of 150 MS suitable sizes pipes for discharge of 80 M3 /hour / pressure rating 2.5 Kgf/cm2,fittings and filtration rate of 25 m3/m2/hr ,including initial filling of filter media , as required for smooth function and operation all as per manufacturer”s recommendations,for swimming pool of 8,00,000 ltr capacity and turn over period of 5-6 hours. Note: 1. Rate quoted shall be inclusive of all type & size of UPVC/HDPE/MS frontal piping, control valves connected to the pressure filter and PCC foundation of suitable size as per manufacturers instructions 2. Piping up to pressure filter in-let & beyond out let of pressure filter and drain pipe shall be measured and paid separately.
Taking down Aluminium/copper point wiring for light/fan/5A/15A plug point including switches,sockets/regulators and deposited in store all as specified and as directed by the Engineer-in-Charge.
Taking down submain wiring Aluminium/copper incl 2x4sqmm/6sqmm/10sqmm and deposited in store all as specified and as directed by the Engineer-in-Charge.
Taking down old main switches/MCB DBs and deposited in store all as specified and as directed by the Engineer-in-Charge.
Taking down Ceiling fan of any capacity and depositing to MES for further disposal all as specified and as directed by the Engineer-in-Charge.
Taking down Exhaust Fan of any capacity and depositing to MES store yard for further disposal all as specified and as directed by the Engineer-in-Charge.
Taking down Electric meter of any capacity and depositing to MES store yard for further disposal all as specified and as directed by the Engineer-in-Charge.
CREATIVE BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.13 MB
NIT.pdf
Tender Documents • 0.12 MB
com_pge.pdf
Tender Documents • 0.18 MB
ps_i.pdf
Tender Documents • 0.10 MB
ps-ii.pdf
Tender Documents • 0.57 MB
SplCon.pdf
Tender Documents • 0.20 MB
Pre_sch.pdf
Tender Documents • 0.08 MB
test.pdf
Tender Documents • 0.06 MB
BOQ_624322.xls
BOQ • 5.69 MB
siteplan.pdf
Additional Documents • 6.19 MB
SWIMMINGPOOLREVISEDDRGS.pdf
Additional Documents • 0.83 MB
structuraldrg.pdf
Additional Documents • 5.24 MB
Download all tender documents and submit your bid