| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | ₹24.8 L Quoted ₹26.1 L | L1 | Accepted-AOC Accepted being the lowest bidder. |
| 2 | L2₹27.0 L+₹89,021 (3.41%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹27.0 L+₹89,021 (3.41%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹30.9 L+₹4.8 L (18.2%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | ₹30.9 L+₹4.8 L (18.2%) | L3 | Rejected-Finance Not L1 |
| 4 | L4₹33.6 L+₹7.5 L (28.8%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | ₹33.6 L+₹7.5 L (28.8%) | L4 | Rejected-Finance Not L1 |
| 5 | L5₹36.9 L+₹10.8 L (41.3%)Rejected-Finance | ₹36.9 L+₹10.8 L (41.3%) | L5 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | M/s Shiv Builder and Suppliers L2 | M/S KAUTILYA GARG L1 | KAVYA ENTERPRISES L5 | VIJAY ENTERPRISES L4 | Nvimal Engineers and Contractor L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/ aluminium point wiring light, fan, socket or power complete (fittings such as switches, ceiling roses, pendents, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge. | 440 | POINT | 35 ₹15,400 | 10 ₹4,400 | 51 ₹22,440 | 5 ₹2,200 Lowest | 7.5 ₹3,300 |
| 2.00 | Cutting chases, pinning in stone concrete block or slab walls, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed. | 615 | RM | 85 ₹52,275 | 40 ₹24,600 | 111 ₹68,265 | 35 ₹21,525 Lowest | 66 ₹40,590 |
| 3.00 | Cutting chases, pinning in brick walls, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed. | 475 | RM | 50 ₹23,750 | 40 ₹19,000 | 111 ₹52,725 | 30 ₹14,250 Lowest | 56 ₹26,600 |
| 4.00 | M&L for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS - 694 (Phase - Red/ Blue/ Yellow, Netural -Black and earth continuity conductor 1.50 Sqmm Green) drawn through stove enameled steel conduit not less than 20x12mm, ISI marked, ivory colour including accessories like bends, tees junction boxes, etc. fixed on wall or ceiling etc. including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size, white sheet cover for mounting swiches, sockets, fan regulators etc. for One light point/fan point controlled by one switch 6 amp one way complete all as specified and directed.
Note:- If concealed wiring on any type of walls cutting chases, pinning in brick walls/ stone walls/ concrete walls shall be measured and paid separately in RM under relavent items. | 40 | POINT | 650 ₹26,000 | 600 ₹24,000 | 751 ₹30,040 | 350 ₹14,000 Lowest | 425 ₹17,000 |
| 5.00 | All as per item no..04 above but for 6 amp socket on same board. | 12 | POINT | 45 ₹540 Lowest | 100 ₹1,200 | 761 ₹9,132 | 220 ₹2,640 | 250 ₹3,000 |
| 6.00 | All as per item no. 04 above but for 6 amp socket on independent board. | 12 | POINT | 720 ₹8,640 | 600 ₹7,200 | 771 ₹9,252 | 420 ₹5,040 Lowest | 425 ₹5,100 |
| 7.00 | All as per item No. 04 above but with 2.5 Sqmm cable for independent one 6 pin 5/ 15 Amps socket outlet In and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 v grade IS - 694 FRLS cable for continuous earth wire. | 26 | POINT | 900 ₹23,400 | 800 ₹20,800 | 851 ₹22,126 | 480 ₹12,480 Lowest | 550 ₹14,300 |
| 8.00 | M&L for point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC concealed conduit 20 mm dia, medium grade, ISI marked, with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) for one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc. and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified and as directed.
Note:- If concealed wiring on any type of walls cutting chases, pinning in brick walls/ stone walls/ concrete walls shall be measured and paid separately in RM under relavent items. | 210 | POINT | 390 ₹81,900 | 400 ₹84,000 | 751 ₹1,57,710 | 350 ₹73,500 Lowest | 375 ₹78,750 |
| 9.00 | All as per item no. 08 above but 3 pin socket outlet, 5 Amp on same board. | 40 | POINT | 45 ₹1,800 Lowest | 100 ₹4,000 | 761 ₹30,440 | 360 ₹14,400 | 100 ₹4,000 |
| 10.00 | All as per item no. 08 above but 3 pin socket outlet, 5 Amp on Independent board. | 40 | POINT | 421 ₹16,840 | 500 ₹20,000 | 771 ₹30,840 | 380 ₹15,200 | 375 ₹15,000 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jul 2025, 6:00 pmClosed
GE AF JODHPUR
GE (AF) Jodhpur
REPAIR MAINT OF ELECTRICAL FITTINGS FIXTURES HIGHBAY LIGHTS CEILING FAN EXHAUST FAN PEDESTAL FAN WALL MOUNTED FAN AIR CIRCULATORS AND ALLIED WORKS IN TECH AREA AND SITE 1A AND 1B OF SU AT AF STN JODHPUR
2025_MES_715416_1
8424/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JODHPUR
₹90,000
Yes
19 Sept 2025
19 Jun 2025
17 Jul 2025
19 Jun 2025
15 Jul 2025
3 Jul 2025
Amount
Taking down carefully copper/ aluminium point wiring light, fan, socket or power complete (fittings such as switches, ceiling roses, pendents, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
Cutting chases, pinning in stone concrete block or slab walls, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
Cutting chases, pinning in brick walls, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS - 694 (Phase - Red/ Blue/ Yellow, Netural -Black and earth continuity conductor 1.50 Sqmm Green) drawn through stove enameled steel conduit not less than 20x12mm, ISI marked, ivory colour including accessories like bends, tees junction boxes, etc. fixed on wall or ceiling etc. including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size, white sheet cover for mounting swiches, sockets, fan regulators etc. for One light point/fan point controlled by one switch 6 amp one way complete all as specified and directed. Note:- If concealed wiring on any type of walls cutting chases, pinning in brick walls/ stone walls/ concrete walls shall be measured and paid separately in RM under relavent items.
All as per item no..04 above but for 6 amp socket on same board.
All as per item no. 04 above but for 6 amp socket on independent board.
All as per item No. 04 above but with 2.5 Sqmm cable for independent one 6 pin 5/ 15 Amps socket outlet In and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 v grade IS - 694 FRLS cable for continuous earth wire.
M&L for point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC concealed conduit 20 mm dia, medium grade, ISI marked, with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) for one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc. and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified and as directed. Note:- If concealed wiring on any type of walls cutting chases, pinning in brick walls/ stone walls/ concrete walls shall be measured and paid separately in RM under relavent items.
All as per item no. 08 above but 3 pin socket outlet, 5 Amp on same board.
All as per item no. 08 above but 3 pin socket outlet, 5 Amp on Independent board.
All as per item no. 08 above but for One bell point controlled by one bell push.
All as per item no. 08 above but with 2.5 Sqmm cable for independent one 6 pin 6/ 16 Amps socket outlet In and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 Volts grade IS - 694 FRLS cable for continuous earth wire.
S&F in repair switch piano 6 amps, flush type, single pole, one way complete all as specified and directed.
S&F in repair switch piano 16 amps, flush type, single pole, one way complete all as specified and directed.
S&F in repair socket outlet flush type, 5 pin, 6 amps complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5 pin, 16 amps, flush type complete all as specified and directed.
S&F in repair modular switches 6 amps, single pole, one way complete all as specified and directed.
S&F in repair modular switches 16 A ,single pole, one way complete all as specified and directed.
S&F in repair modular socketes outlet 6 amps, 5 pin complete all as specified and directed.
S&F in repair modular socket 6-16 A, 3 pin, combined ced shuttered complete all as specified and directed.
S&F in repair switch bell push flush type, 5 Amps, 240 volts complete all as specified and directed.
S&F in repair switch bell push modular type, 5 Amps, 240 volts complete all as specified and directed.
S&F in repair call bell ding dong muscial type, AC, 230 Volts, single pole complete all as specified and directed.
S&F in repair modular step fan speed regulator 5 steps complete all as specified and directed.
S&F in repair steped type elecrtonic fan regulator flush type on the existing phenolic laminated sheet etc suitable for 240 volt complete all as specified and directed.
M&L for taking down existing metal/ wooden box, switch board sheets, cover plates on walls and supply and fixing 3 way module cover plate with modular metal box complete all as specified and directed. Note:- Cutting of walls, fixing of metal boards, cover plates, making good a disturbed surfaces as existing are included in the quoted rates.
All as per item no. 26 above but 4 way module cover plate with modular metal box.
All as per item no. 26 above but 6 way module cover plate with modular metal box.
All as per item no. 26 above but 8 way module cover plate with modular metal box.
S&F in repair sheet metal enclosures with socket plug top and MCBs having single pole and nutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, 240 V complete all as specified and directed.
Supply and draw submain wiring with two single core 6 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into PVC conduit and all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed. Note:- (i) If concealed sub-main wiring on any type of walls cutting chases, pinning in brick walls/ stone walls/ concrete walls are measured and paid separately in RM under relavent items. (ii) Necessary scaffoldings are included the quoted rates. (iii) All runs of cable and one run of conduit shall be measured as one lenth of unit.
All as per Item No. 31 above but two single core 4 Sqmm for phase and neutral and 01 single core 4 Sqmm for earth wire.
All as per Item No. 31 above but two single core 2.5 Sqmm for phase and neutral and 01 single core 2.5 Sqmm for earth wire.
Supply and draw submain wiring with two single core 2.5 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into steel conduit and all necessary fittings including 2.5 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete including taking down old unserviceable submain wiring of any size and making good disturbed surface complete all as specified and directed. Note:- (i) If concealed sub-main wiring on any type of walls cutting chases, pinning in brick walls/ stone walls/ concrete walls are measured and paid separately in RM under relavent items. (ii) Necessary scaffoldings are included the quoted rate. (iii) All runs of cable and one run of conduit shall be measured as one lenth of unit.
All as per Item No. 34 above but two single core 1.5 Sqmm for phase and neutral and 01 single core 1.5 Sqmm for earth wire.
S&F in repair single pole neutral sheet metal enclosure for 08 way DBs when SPN to be used single phase 240 volts, single door complete all as specified and directed.
S&F in repair single pole neutral sheet metal enclosure for 12 way DBs when SPN to be used single phase 240 volts, single door complete all as specified and directed.
S&F in repair double door triple pole neutral Sheet metal enclosure DB 04 way when TPN to be used three phase 440 volts, including suitable for fixing of one TPN incommer and four TPN outcomer alongwith neutral links, cable in and out entry, cable gland packings, thimbles complete all as specified and directed. Note:- TPN MCB shall be measured and paid separately.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked, including required wiring connections with copper lugs of suitable size provided in MCB DBs of single pole 6 to 32 amp complete all as specified and directed.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked, including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 40 to 63 amp complete all as specified and directed.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 to 100 amp complete all as specified and directed.
S&F in repair MCCB 4 pole, 415 V, adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in repair IP 43 metal door vertical TPN DB with MCCB incomer of capacity 125A incomer, IK-09 model double door built with CRCA sheet steel powder coated enclosure, provided with insulated vertical phase bus bars/ neutral bars with shrouds/ earth bars, sticking saddles/ cement spill protector/ color coded interconnecting wire set, cable ties, blanking plates with provision for 4 pole MCCB* as incomer and TP MCBs as outgoings complete fixed into wall with grouting work breaking of wall/ cutting of wall surfaces and making goods with plaster/ wooden works colour washing to distubed surface complete all as specified and directed. Make:- L&T cat part no. DEVTL006DD or equivalent in Havells/ Standrad as approved by GE. Note:- MCCB, MCBs shall be measured and paid separately.
S&F in repiar 6500 K cool white LED 4 feet tube light fitting 1x 36 W LED linear batten aluminum HLO LED batten made from aluminium extruded channel, powder coated with opaque diffuser for glare free light complete with accessories connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repiar 6500 K cool white LED 4 feet tube light fitting 1x 20 W LED linear batten aluminum HLO LED batten made from aluminium extruded channel, powder coated with opaque diffuser for glare free light complete with accessories connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in replacement elegant white colour ceiling fan of size 1200 mm sweep, 3 blades, five speed, noise level up to 65 dB, single phase, 230 Volts, 50 HZ complete all as specified and directed. Make:- Havells cat No. FHCHM5SWHT48 or equivalent in Philips/ Bajaj/ Usha as approved by GE.
S&F in replacement metalic type ventil air DS Green single phase exhaust fan of sweep size 300 mm (12 inch), 1400 RPM, colour - Grey, three arm fan blades, steel shutters on exhaust side single phase 230 Volts, 50 HZ complete all as specified and directed. Make:- Havells cat No. FHVVEMTDSB12 or equivalent in Philips/ Bajaj/ Usha as approved by GE.
S&F in replacement metalic body round/ square type shutters suitable for of 300 mm sweep exhaust fans size (12 inch), colour - Grey, complete all as specified and directed.
S&F in replacement single phase non-metalic PVC exhaust fan of 10" Sweep alongwith PVC shutters complete all as specified and directed.
S&F in repair precisely designed decorative LED - IC serene slim backlit recess mounting 2x2 LED 36 W luminaire suitable for 2'x2' grid ceiling with flat duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified and directed.
M&L for cutting holes 300mm/ 450mm diameter for preaparing opening through brick/ stone masonary wall for fixing exhaust fan 300mm/ 450mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall complete all as specified and directed.
S&F in repair industrial LED warm white flame proof monochromatic clean room lighting fixture sealing/ surface mounted 600 x 600 mm, 60 Watt CMRI certified LED lights fixture, flame proof fittings suitable to use in gas/ vapor group zone area with an ingress protection of IP 65 as per IS/ IEC 60079-7 : 2006 for storage spaces within cleanroom areas. comes with an body material: die cast aluminium alloy, 6500 K, CLT22 series, area clasification: zone 1&2, material construction: M.S with stainless steel frame, earthing 01 No. inside & 2 Nos. outside, fixing arrange accessories, cable entry M 20x2 Nos. complete all as specified and directed. Note:- (i) Necessary scaffoldings for fixing flame lights are deemed to be included in quoted rate. (ii) Fixing accessories which are require to be fix flame proof lights are deemed to be included in quoted rate.
S&F in repair 200 Watt heavy duty LED highbay luminaries with engineering grade diffuser for added protection, secondary optics, suitable for industrial lighting applications, with options of IP65/ IP66 complete. Make:- Shakti model no. SZHHCPX200 or equivalent in Wipro/ Philips/ Crompton as approved by GE. Note:- (i) Necessary scaffoldings for fixing flame lights aredeemed to be included in quoted rate. (ii) Fixing accessories which are require to be fix flame proof lights are deemed to be included in quoted rate.
Taking down and dismantling the ceiling fan of any sweep & size from site and removing its allied smaller parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc. and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers complete including, flexible chord of 24/ 0.20mm with necessary connector (for blade/ body) as required after rewinding complete all as specified and directed. Note:- (a) Spares used shall be measured and paid seperatly under relevant item. (b) Re-winding shall be measured and paid seperately under relevant item.
All as per item No. 54 above but exhaust fan of any sweep & size. Note:- (a) Spares used shall be measured and paid seperatly under relevant item. (b) Re-winding shall be measured and paid seperately under relevant item.
All as per item No. 54 above but air circulators fan/ pedestal fan/ wall mounting fan of any sweep & size. Note:- (a) Spares used shall be measured and paid seperatly under relevant item. (b) Re-winding shall be measured and paid seperately under relevant item.
M&L for rewinding the ceiling fan of any sweep and size using super enamelled copper conductor cable of suitable gauge including insulation, varnishing, packing, etc. complete all as specified and as directed.
All as per item No. 57 above but for exhaust fan 300 to 450mm sweep.
All as per item No. 57 above but for air circulators/ pedestal fan of any sweep and size.
All as per item No. 57 above but for wall mounting fan of any sweep and size.
Supply only ball bearing suitable for ceiling fan of any sweep and size complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan any sweep and size complete all as specified and directed.
Supply only ball bearing suitable for air circulators/ pedestal/ wall mounting fan of any sweep and size complete all as specified and directed.
Supply only rotar for exhaust fan/ wall mounting fan, etc. complete all as specified and directed.
Supply only brass bush suitable for the ceiling fan of any capacity complete all as specified and directed.
Supply only brass bush suitable for the exhaust fan, wall mounting fan, air circulator of any capacity complete all as specified and directed.
Supply only shaft for ceiling fan/ exhaust fan/ wall mounting fan, air circulator complete all as specified and directed.
S&F in repair shakle and clamps including, rubber bush, bolts, nuts and split pin, fastners etc. for hanging of any sweep and size ceiling fan on roof top complete all as specified and directed.
S&F in repair modular fan step regulator, 120 W, 2 module complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenilic laminated sheet etc. as required complete all as specified and directed.
S&F in repair fan capacitors of size 2.5 MFD complete all as specified and directed.
S&F in repair fan capacitors of size 4 MFD complete all as specified and directed.
S&F in repair metalic body round/ square type shutters of grey colour, suitable for upto 450 mm sweep exhaust fan complete all as specified and directed.
S&F in repair steel wire mesh net mosquito alongwith aluminium frame, shape in round/ square type suitable for upto 450 mm sweep exhaust fans, necessary fixing materials complete all as specified and directed.
M&L for cutting holes 300mm/ 450mm diameter for preaparing opening through brick/ stone masonary wall for fixing exhaust fan 300mm/ 450mm sweep, making good to damaged surface of wall, make a smooth circular/ square surface and match with specification of existing wall complete all as specified and directed by Engr-in-Charge.
S&F louvers for exhaust fan of size 225mm to 450 mm sweep suitable for existing shape and size including taking down existing unserviceable/ rusted louvers complete all as specified and directed.
M&L for cleaning, preparing the old painted ceiling fans of any sweep and painting with one coat of synthetic enamel paint complete all as specified and directed
All as per item No. 77 above but for exhaust fan any sweep.
All as per item No. 77 above but for air circulator/ pedestal fan/ wall mounting fan.
S&F in repair MS down rod of size 15 mm bore 24" long including making holes etc. complete all as specified and directed.
S&F in repair MS down rod of size 15 mm bore 18" long including making holes etc. complete all as specified and directed.
S&F in repair MS down rod of size 15 mm bore 12" long including making holes etc. complete all as specified and directed.
S&F in repair blades set suitable for ceiling fan 1200/ 1400 mm sweep any make as per site requirement complete all as specified and directed.
S&F in repair blades set suitable for exhaust fan 300/ 450mm sweep any make as per site requirement complete all as specified and directed.
S&F in repair aluminum alloy blades set suitable for air circulators of size upto 650 mm sweep any make as per site requirement complete all as specified and directed.
S&F in repair MS down rod of size 15 mm bore 36" long including making holes etc. complete all as specified and directed.
S&F in replacement metalic type, turbo force, exhaust fan of sweep size 300 mm (12 inch), 1400 RPM, colour - grey, four arm fan blades, steel shutters on exhaust side, single phase, 230 Volts, 50 Hz complete all as specified and directed.
S&F in replacement single phase, non-metalic, PVC exhaust fan of 10" sweep alongwith PVC shutters complete all as specified and directed.
S&F in repair heating element including rubber gasket and washer etc. of capacity 1.5 KW suitable for existing make and shape complete all as specified and directed.
S&F in repair heating element including rubber gasket and washer etc. of capacity 2 KW suitable for existing make and shape complete all as specified and directed.
S&F in repair thermostat including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree centigrade suitable for existing geysers of capacity 25/ 35/ 50 ltrs complete all as specified and directed.
S&F in repair fusible plug melting at 90 - 100 degrees centigrade complete all as specified and directed.
S&F in repair high pressure valve with dead weight suitable for 25/ 50 ltrs capacity geysers complete all as specified and directed.
M&L for preparation of surface of geyser 25/ 50 Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour over a coat of zinc primer complete all as specified and directed.
S&F in repair armoured PVC connecting pipe 18" long with brass adopters for cold water and connecting up with complete for 25/ 35/ 50 ltrs capacity geysers complete all as specified and directed.
All as per item No. 95 above but hot water connection pipe.
S&F in repair indication lamp for 25/ 35/ 50 ltrs capacity geysers complete all as specified and directed.
S&F in repair 10 mm thick MS plate, nut & bolts, rubber packings suitable to connecting with air circulators stand of sweep size up to 750 mm along with switch box for speed controlling in four position including control wiring and required accessories for fixing air circulators on any type of wall/ steel structures complete all as specified and directed.
S&F in replacement industrial type, heavy duty, turbo force, wall/ steel girders mounting air circulators, air delivery 300 CMM, Colour - Parrot Green, No of Blades - 03 (aluminium alloy), Series - Turbo force, Single Phase - 220-240 V, speed-1400 RPM, Sweep size - 750 mm, suitable fixing on walls and supply steel structures including clamps, MS plates with Nut & Bolts & other required accessories for fixing of fans complete all as speified and directed
S&F in replacement desert cooler steel body, made of 22 gauge GI Sheet, electric driven, single phase, including heavy duty fan 1400 RPM, water pump, wooden pads etc. having nominal air flow capacity of 5000 Cum per hour or nearest size and tank capacity atleast 40 litres, having two speed modes min & Max complete all as specified and directed.
M/s Shiv Builder and Suppliers (BID ID -3350786)
Nvimal Engineers and Contractor (BID ID -3349551)
VIJAY ENTERPRISES (BID ID -3359991)
KAVYA ENTERPRISES (BID ID -3359042)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .