| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹35.1 L+₹1.7 L (5.19%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹35.2 L+₹1.9 L (5.62%)Rejected-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹36.1 L+₹2.7 L (8.24%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹40.3 L+₹6.9 L (20.7%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
19 Aug 2021, 6:00 pmClosed
GE (I) CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
REPAIR, MAINT/REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY, DG SET, INTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY, AC, GEYSER AND OTHER MISC ITEMS AT CGDHQ-15 OKHA UNDER GE(I) CG PORBANDAR
2021_MES_464185_1
8637
Open Tender
Civil Works
Item Rate
180 days
CGDHQ-15 OKHA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (I) CG PORBANDAR
₹64,000
Yes
27 Oct 2021
31 Jul 2021
20 Aug 2021
31 Jul 2021
19 Aug 2021
14 Aug 2021
Amount
SCHEDULE 'A'
Servicing of DG set ('C' Check) of Cap 100/125 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolant top up. Make of DG set: Ashok Leyland/ Kirloskar Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts/ Items of DG set 100/125 KVA (Make : Ashok Leyland/ Kirloskar) Oil Filter
Fuel Filter
Air Filter
Fuel Filter Assembly
Coolant
Engine Oil
Battery Terminals
Hose Pipe Set
AVR as per existing Specification
Servicing of DG set ('B' Check) of Cap 100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. Note: Defective parts if any other than listed at (a) to (c) above will be measured and paid separately
Supply only parts/ Items of DG set 100 KVA (Make :Koel) Spinion lube Oil Filter
Fuel Filter
Fuel Filter Assembly
Engine Oil
Servicing of DG set ('C' Check) of Cap 20/25/30 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolant top up. Make of DG set: Ashok Leyland/ Kirloskar Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts/ Items of DG set 20/25/30 KVA (Make : Ashok Leyland/ Kirloskar) Oil Filter
Fuel Filter
Air Filter
Fuel Filter Assembly
Coolant
Engine Oil
Battery Terminals
Hose Pipe Set
AVR as per existing Specification
Servicing/Calibration of old AMF Panel and rectification of defect if any including Repair/ Replacement of Unserviceable items all as specified and directed by engineer in charge.
AMF controller as per existing Make
Relay Card Start/Stop
Relay Card Contactor
4ST relay
Wiring as per existing specification
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts other than capacitors and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge. Note: Defective parts if any will be measured and paid seprately
Supply only items for APFC Panel Heavy duty gas filled Capacitor 10 KVAR,415V, 3phase, 50 Hz. Make: L&T/Legrand/Siemens
Heavy duty gas filled Capacitor 5 KVAR,415V, 3phase, 50 Hz. Make: L&T/Legrand/Siemens
Heavy duty gas filled Capacitor 3 KVAR/2KVAR,415V, 3phase, 50 Hz. Make: L&T/Legrand/Siemens
Supply and fix in replacement power factor controller,microcontroller based, 230V, 50HZ, 8+1 Alarm, all as specified and directed by engineer-in-charge Make: Havells/ L&T/Legrand/Siemens
Servicing of Servo Stabilizer oil cooled automatic type of capacity100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel level, supply system, Lubrication system, cooling system, rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lubrication oil. (b) 3 Phase Digital display system Make of Stabilizer : Volina Note: Defective parts if any will be measured and paid separately
M&L preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and apply one coat of red oxide on surface of PCC poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm black base complete all as spd and as directed by Engineer-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand/sintex
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
Material & Labour Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of following sizes-Make-Denson/Siemen, , complete all as specified and directed by Engr-in-Charge. 25 sq mm to 50 sq mm
70 sq mm to 150 sqmm
Taking out UNSV LT UG cables of any sizes from trenches ,retrieving of cover and stacking for reuse, complete all as specified and directed by Engr-in-Charge.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area. Make: Polycab/ Havells/Finolex/KEI, complete all as specified and directed by Engr-in-Charge. 120 Sqmm 3.5 Core
35 Sqmm 3.5 Core
16 Sqmm 4 Core
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick , complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point , complete all as specified and directed by Engr-in-Charge.
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories all as specified and directed by Engr-in-Charge. Note: (i) Cutting of floor/ road and making good with PCC deemed to be included in item rate Make: Rex/Poly/Gemini 63 mm OD
Supply and fix in replacement MCCB 4 pole 100 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 63 Amps of Breaking capacity 16KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 200 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement of LED driver of 150 watt search light of Input 240 V , 1.7 A, 50 Hz, output +54 V DC , IP 65 rated make as per existing
S & F 70 Watt LED street light luminaire, High Performance street light luminaire having Single Die ceramic base high power LED light source, IP66 protection, PDC housing with Finless design and polycarbobate cover (IK08) rated Voltage 240 Volt ,50 HZ, operating voltage Range 120-270 Volt , with mounting clamps, bolts and nuts,and bracket as specified with pole complete all as specified and as directed Make: Philips (BRP062 LED 84 CW SLC S1 PSU) /Wipro (LR02-781-XXX-57-G2)/Osram Lux power ST G2 35 Watt CW 20 x 1 AM 3100100GF
Cutting & removing existing joint and supply, jointing and testing outdoor type Heat hrinkable straight through cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade , complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON/3M.
Cutting & removing existing joint and supply, jointing and testing indoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON/3M
M&L for Dehydration/Centrifuging of tranformer oil minimum 3 cycles to achieve dielectrical strength 50KV in 2.5mm gap electrode with centrifuging machine at site and testing of transformer oil before and after dehydration complete all as specified and as directed by Engr-in-Charge.
M&L for topping up/replacement of transformar chamber and conservator with new transformer oil upto a required level (60 KV di- electric strength in 2.5 mm gap elevtrode to with stand for one minute) in any type and capacity of transformer complete all as specified and directed at site.
M&L for servicing and renewal/replacement of defective parts of oil type transformer capacity 400 KVA 11/.433KV indoor/out door type of any make by disconnecting of HT bus bar connection and providing electric power to user by alternative arrangement, opening of doors etc complete cleaning of the inside compartment,core and coils by vacuum cleaner incl lead supports,tap changer terminal boards,bushing and other insulated surface be wiped clean with dry cloth and all connection must be checked for tightening after cleaning up tothe satisfaction of Engr-in charge the transformer must be meggred and connectiong all connection and necessary testing complete with under mentioned scope of work defective part measured and paid under respective item however fixing charges included (i) Cleaninf of transformer from inside/out side including painting of outer body parts with existing specification (ii) Testing the transformer for IR values (iii) Checking/servicing/calibr ationof WTI for healthiness (iv) Magnetic balance test (v) IR Value check beforeand after the work (vi) Voltage ratio test at 440V. (vii) DC logic test (viii) Commissioning of transformer after completion of work. Note :- (i) Test result obtained shall be recorded and produced to the Engr-in-Charge. (ii) All measuring equipments and T & P required shall be arranged by the contractor. (iii) Any item/activity not listed/covred here above and required during/completing the overhauling work will have to be arranged by contractor himself. (iv) The rate quoted shall be deemed to include for disconnection of transformer HV/LV terminations for testing work and re-connections after completion of repair work.
Comperehensive maintenance / Calibration of RMU panel 11 KV, detection of defective components, replacement of wornout parts and servicing/cleaning of mechanical components through authorised service centre of VCB manufacturer /OEM or skilled VCB repairing agency, re-insertion oftrolly in HT panel, testing for smooth complete all as specified and directed by Engr-in-charge. Note: Worn out parts shall be measured & paid seperately under respective items.
Supply only parts/items for RMU Numerical relay for earth fault over current/short circuit, 24V/30V DC operated and setting at site complete all as specified and as directed Make: CG/L&T MC16C/AREVA
Motor cut off Limit switch Make: BCH/L&T/C&S
Closing coil 24V DC Assembly
Shunt trip coil 24V DC
Comprehensive maintenance, servicing and testing of AC of any make complete for during contract period by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, greasing of blower motor, checking and removing any vibration , and testing at site all as directed by Engineer-in-Charge. Note:(a) Cost of any minor nature repair / items such as nuts ,bolts,washers,screws,rubber mounting pads of compressor,top up of gas, etc and labour required for removing / refixing after repair of equipment is deemed to be included in the unit rate of this items. (b) Wornout compressure , blower motor, replacement if required shall be measured and paid seperately. a) Split type air conditioners of capacity 1.5 ton
Split type air conditioners of capacity 2.0 ton
M&L for detecting the cause of leakage in any type/capacity of 1.5 tonne AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity as directed by EIC including testing for smooth functioning complete all as specified and as directed. Notes :- (i) Dismantling of unserviceable compressor , cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates .
Ditto- but of capacity 2 tonne .
M&L for refrigerant tubing for suction /discharge including insulation tubing all as per site requirement and as directed by Engr-in-Charge.
Supply only spare part for Split type AC cap 1.5/2.0 TR of make as per AC of Item No. 1 Compressor Heremetically sealed Rotary Type for 1.5 TR AC
Compressor Heremetically sealed Rotary Type for 2.0 TR AC
Blower Motor / condensor Motor for 1.5/2.0 TR AC
Outdoor Unit without compressor for 1.5/2.0 TR AC
Indoor Unit with remote 1.5/2.0 TR AC
S&F in replacement of condensing coil (copper) of indoor split type AC 1.5/2.0 Tonne capacity complete all as per existing make and model
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 Litre complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed.
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc , complete all as specified and directed by Engr-in-Charge.
Taking down submain wiring of size 2.5 and 4.0 sqmm complete and making good to disturbed surfaces of wall ceiling and floor etc complete all as specified and directed
M&L Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets and fan regulators complete all as specified and as directed by Engineer-in-Charge. for the following:- Make of cable: Havells/ Finolex/ RR Kable/ KEI (a) One light point /fan point controlled by one switch with cable 1.5 Sqmm
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
M&L Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 2.8mm thick bakelite sheet white/coloured top cover for mounting of modular switches, sockets and fan regulators complete all as specified and as directed by Engineer-in-Charge. for the following:- Make of cable: Havells/ Finolex/ RR Kable/ KEI (a) one 3/5 pin 15/16 Amps socket
M&L for sub main wiring with two run of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
M&L for sub main wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
S&F in replacement MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engr-in-Charge. Make Hager/ L&T/ Legrand.
Supply and fix in replacement MCCB 4 pole 100 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 63 Amps of Breaking capacity 16KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 160 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately.
Supply only spare parts for Geyser Heating element 1.5 KW with rubber gasket .
Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug top
Supply and fix hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler , complete all as specified and directed by Engr-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor, rewinding electric motor, single phase 230 Volts of water cooler 40 ltrs/Hrs with super enameled copper wire of same gauge, complete all as specified and directed by Engr-in-Charge.
Supply and fix relay for water cooler of capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make Renetor/ Shriram /Dunfoss.
Supply and fix Thermostat for water cooler capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make:Renetor/shriram/Godraj/Danfoss
Supply and fix PVC Float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Casing and caping size 25mmX16mm , complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ , complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge..
Dismantling of Exhaust fan 250mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge.
S&F in repair 10 Watt LED batten luminaire suitable for wall mounting of capacity 10 Watt 2 feet long with voltage range 100-240 volts and inbuilt protection,complete all as specified and directed by Engr-in-Charge. Make: Wipro(LL20-111-XXX-65-NE3) or equivalent in Philips/Crompton Greaves.
S&F in repair 20 Watt LED luminaire, nominal lumen output 2000 lm, extruded aluminum housing, IP20,voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed by Engr-in-Charge. Make: WIPRO (LL20-281-XXX-65AL1) or equivalent in Philips/Crompton Greaves
S&F in replacement LED Luminaires recessed mounted down lighter 18/20 watt 5700K system efficiency not less than 100lm/watt,thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires complete all as specified and as directed by Engineer-in-Charge. Make :Wipro (LD06-221-XXX-57-XX) or equivalent in Philips/Crompton Greaves
S&F in replacementr 12 W 3000 colour Lumens LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast Make : Wipro Cat part No LD98-131-024-40-XX or equivalent in Philips/Crompton Greaves
S&F in replacement 10 watt flood light of cool white, IP 65 rated, 80lm/W efficacy, including mounting arrangement and driver complete all as specified and directed by Engr-in-Charge. Make : Philips Cat No. BVP131 LED8/CW 10W 100-240V WB IN or equivalent in Wipro/Crompton Greaves
S&F in Replacement of u/s light any type LED flood light 150 Watt LM6 high pressure die cast aluminium housing, IP 66, Nominal Lumen output 14000 lm, Colour temprature 5700K, THD<10%, PF>0.95, Operating Voltage 140-270V AC, 50HZ , complete all as specified and directed by Engr-in-Charge. Make: Wipro cat part No-LF20-192-060-57-G2 or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s LED building security light of capacity 30 watt , LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro cat part No-LR02-331-XXX-57-XX or equivalent in Philips/Crompton Greaves
S&F in replacement LED driver for 300 watt LED light fittings confirming to IP 67 rating out put 12 V 23 A DC , input 180-270 V AC complete all as specified and directed. Make : as per existing
S&F in replacement LED driver for 12/22 watt LED light fittings confirming to IP 66 rating input 180-270 V AC complete all as specified and directed. Make : as per existing
Supply and fix in replacement following items for maintenance of Internal Electrification , complete all as specified and directed by Engr-in-Charge. Lamp holder plug for Batten fitting.
Piano switch, flush type 5 Amps, 1 way.
Piano switch, flush type 5 Amps, 2 way.
Bell push, flush type 5 Amp.
Electric bell Ding Dong type , 230 Volts Single pole.
Socket Outlet 2 in 1, 3 pin, 6A
Switch socket combination, 6 Amps flush type.
Switch socket combination, 16 Amps flush type.
2.5 mfd Capacitor
Stepped type electronic fan regulator
Modular switch 1 way 6 amp 1 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular switch 1 way 16 amp 1 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular socket 6A-2/3 pin combined, 2 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular socket 6A/16A-2/3 pin combined, 2 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
White cover plate with frame,2 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
White cover plate with frame,3 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
White cover plate with frame,4 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
White cover plate with frame,6 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
White cover plate with frame,8 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular Metal/polycarbonate Flush Box, 2 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular Metal/polycarbonate Flush Box, 3 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular Metal/polycarbonate Flush Box, 4 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular Metal/polycarbonate Flush Box, 6 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Modular Metal/polycarbonate Flush Box, 8 module Make: Legrand (Arteor)/Schneider (Zencelo)/Hager (Berker)
Ceiling rose surface type bakelite / PVC three terminal 65 x 50mm.
Supply and fix in replacment MCB of following rating Make legrand/Siemens/L&T, complete all as specified and directed by Engr-in-Charge. 6-32 Amp SP ,240 volt 'C' series, 10 KA
32 Amp SPN ,240 volt 'C' series, 10 KA
32 Amp TPN,440 volt 'C' series, 10 KA
63 Amp TPN,440 volt 'C' series, 10 KA
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of following sizes 25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and lay lead free uPVC pipe in trenches/walls/cellings or laying in floors including suitable amount of solvent for piping and all fittings including threaded and sovent base as per site requirement complete of sizes of nominal dia:- 25 mm bore Make: Astral/Supreme/Finolex
40 mm bore Make: Astral/Supreme/Finolex
50 mm bore Make: Astral/Supreme/Finolex
80 mm bore Make: Astral/Supreme/Finolex
S & F uPVC Gate /ball valves as per requirement of the site of the following 25 mm bore Make: Astral/Supreme/Finolex
40 mm bore Make: Astral/Supreme/Finolex
50 mm bore Make: Astral/Supreme/Finolex
80 mm bore Make: Astral/Supreme/Finolex
Dismantling the centrifugal Pump 15 HP including disconnecting suction and delivery etc and reassembling after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete all as specified and as directed by Engr in charge. [NOTE: Replacemnt of worn out spares will be measured and paid separately].
Supply and replace following worn out spares of Centrifugal/monoblock pump sets. Bearing as per existing Size suitable for 15 HP motor
Rubber bush for coupling as per existing size for 15 HP motor
Gland packing for 15 HP motor
Taking down electric motor 3 phase, 415 Volt capacity 15 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Construction of brick masonry valve pit complete including necessary excavation and earth work complete all as specified with internal dimension 150x150x110cm (type 'B') including MS sheet cover 3mm thick welded with hinges on angle iron frame 50x50x6mm with hold fast grouted in 100mm thick PCC (1:2:4) type B-1 coping on top of brick wall including necessary locking arrangement complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable foot valve 80/100 mm dia from the UG sump and S & F new foot valve 80 mm dia ball type incl rubber gasket, bolts, buts complete all as directed. Make: Kartar/Kirloskar/Normax/Zoloto
Supply & fix of sluice valves flanged type class PN 1.6 complete all as specified and directed 100 mm dia bore Make: Kartar/Kirloskar/Normax/Zoloto
150 mm dia bore Make: Kartar/Kirloskar/Normax/Zoloto
300 mm dia bore Make: Kartar/Kirloskar/Normax/Zoloto
Supply and fix in replacement Automatic star delta starter for 15/20 Hp centrifugal mono block pump set, 415 V 50 Hz three phase as per existing specification all as specified and directed. Make: BCH/L&T/ABB
M&L Earthing complete with Copper earth electrode 30 cm x 30 cm x 3.15 mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to copper strip 20X3mm as earthing lead by means of bolts,nuts, check nuts and washer etc made of copper/brass including 40 mm bore GI pipe medium grade up to 7.5 metres long all as shown in electrcial plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/ earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and as directed by Engr-in-charge. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any additional in length shall be adjusted through deviation order. (ii) Item includes trhe cost of 7.5 metre GI earth lead. Any additional in length shall be measured and paid under respective item of this Schedule.
Comprehensive maintenance / servicing and repair of search light system by replacement of worn out parts, and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories /relay/single phase preventor/motors etc. all as specified and directed by engineer-in-charge.
OM ENGINEERING
fakhrie apostrical
K K Construction Co
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .