Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.7 LAccepted-AOC OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC L1 | |
| 2 | L2₹90.6 L+₹25.0 L (38.0%)Rejected-Finance GN6 BASEMENT GROUND FLOOR SHIVAJI COLLEGE ROAD OPP KOHLI TENT HOUSE RAJOURI GARDEN NEW DELHI WEST DELHI DELHI 110027 | WEST DELHI | DELHI | 110027 | L2 | Rejected-Finance BEING OTHER THAN L1 BID | |
| 3 | L3₹99.5 L+₹33.8 L (51.4%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-Finance BEING OTHER THAN L1 BID |
Tender Value
₹9.4 Cr
EMD Value
₹1.7 L
Closing Date
30 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAREILLY
HQ Commander Works Engineers AF Military Engineer Services Bareilly 243002
PROVN OF PRE-FABRICATED STRUCTURE FOR LIVING OFFICERS AND AIRMEN AT AF STN BHOWALI
2024_MES_670247_1
81440/E8
Open Tender
Civil Works - Others
Lump-sum
180 days
BHOWALI
AS PER NIT
10 documents required · 10 mandatory
₹1,000
AGE(I) AF BHOWALIl
₹1.7 L
12 Dec 2024
2 Sept 2024
2 Nov 2024
2 Sept 2024
30 Oct 2024
18 Oct 2024
3 Sept 2024 - 30 Sept 2024
Amount
NOTE: Schedule ‘A’ Part I under Ser No. 1.10 to 1.30 are not prepriced by MES and estimated rates indicates 0.00 under column 6 signified this fact only (Lumpsum amount to be quoted by the bidders under column 7).
Design, supply & Erection of three room set pre-fab building built based on LGSF technology for single occupancy with individual toilet including provision water tank staging with tank of 1000 Ltr capacity & booster pump, 2 mtr wide approach path with core Endura tiles in front of building etc. complete all as specified & shown in drawings.
Design, supply & Erection of two room set pre-fab building built based on LGSF technology for single occupancy with individual toilet including provision water tank staging with tank of 500 Ltr capacity & booster pump, 2 mtr wide approach path with core Endura tiles in front of building etc. complete all as specified & shown in drawings. Note for item No 1.10 & 1.20 above- (i) LGSF/Structural steel shall be of procured from main producer of steel i.e Tata/SAIL/RINL/JINDAL. (ii) The contractor shall submit complete design with all parameters duly vetted all as specified in particular specification for approval and changes suggested based on structural/technical/utility requirement shall be incorporated without any additional cost and deemed to included in quoted rate. Similarly the quoted rate is for entire completion of pre-fab building with foundation & complete fixing all fitting/fixtures (quoted lumpsum amount/rate is excluded catered for item No 1.30 to 3.39) for immediate use. (iii) The following shown/specified in drawings/specified in notes stipulated are not included in quoted lumpsum of item No 1.10 & 1.20 above, hence lumpsum amount is to be quoted accordingly:- Refer Drg No CWE/AF/BHOW/AR-08 sheet -1/7(R) & CWE/AF/BHOW/AR-09 sheet-1/6(R) Note No 4 stipulated for furniture items and Note No.6 stipulated for Septic tank with soak pit are not included in above items.
Design, construction of Septic tank of size 1.70 m x 5.20 m with soak pit size 1.50 m x 1.50 m x 2.40 m built with sub class ‘B’ brick masonry in 1:4 outer wall, concrete block baffle wall built in CM 1:3, PCC 1:3:6 flooring, RCC M-25 cover slab, sewer line of RCC NP3 150 mm diameter Pipes laid on 150 mm thick bed in PCC 1:4:8 type D2 with excavation in any type of soil, haunching, including manholes/drop manhole of outer size 1.0x1.0 m made of Brick masonry in CM 1:4 with RCC M25 cover and frame and all items and activities to execute and make sewer line functional including all sanitary work required for connection upto toilet complete all as specified & shown in drawings
NOTE: Schedule ‘A’ Part II to V under Ser No. 2.10 to 2.40 are Pre-priced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE & DEVELOPMENT” as listed in Schedule ‘A’ Part-II
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-V
SCHEDULE `A' PART -VI (MISC E/M ITEMS) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
M&L for point wiring using approved colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 sq mm nominal cross sectional area, single core, PVC insulated and unsheathed FR-LSH cable 1100 volts grade ISI-694 marked with valid CML No drawn through new PVC casing & caping ISI marked including provision of casing & caping, fabricated branded modular steel flush box duly make embossed, fixed on wall with suitable modular inner and outer plate module for housing modular switches/socket outlets/fan regulator etc. including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FR-LSH cable as earth continuity conductor to common earth and connecting to earth dolly, complete for light/ceiling fan/exhaust fan point controlled by one 5/6 amps one way switch complete all as specified and directed. (Note : Modular Switch / socket and fan regulator measured and paid separately under respective items).
One light point or one fan point controlled by one way, single pole switch complete all as specified and directed.
One bell/buzzer point controlled by one push button, complete all as specified and directed.
One 3 pin socket outlet 5 Amp on independent board complete all as specified and directed.
One 3 pin socket outlet, 5 Amps on same board with other switches complete all as specified and directed.
All as per item No. 3.10 here-in-before but point wiring using 2.5 Sqmm (nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 16 Amps on independent board with 2.5 sqmm with one single run copper conductor cable as earth continuity to common earth dolly, complete all as specified & directed.
Supply & fixing modular switch one way 6 Amps, 1 module, 240 volt, single pole , ISI marked conforming to IS 3854 style single colour series with complete all as specified and directed.
Supply & fixing Socket, 6A - 2/3 pin combined 2 module, 240 Volt AC, flush type, style single colour series with complete all as specified and directed.
Supply & fixing modular Switch one way 16A, 1 module, 240 volt AC, style with single colour series"complete all as specified and directed.
Supply & fixing modular socket outlet 6A/16 A -2/3 pin,combined 2 module, 240 Volt AC, style with single colour series"complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50 mm, three terminals with back plate etc. complete all as specified and directed.
Supply & fixing modular bell push 6 Amps, 1 module, 240 volt, complete all as specified and directed.
Supply and fixing Bell, multi music type AC 230 volts, single pole all specified & directed.
S&F electronic step type fan regulator 240 volts, 50 Hz, 120 watt. modular type complete all as specified and directed.
Supply and fixing of white cover plate with frame, 2 module for modular switch/socket complete all as specified and directed.
Supply and fixing of white cover plate with frame, 3 module for modular switch/socket complete all as specified and directed.
Supply and fixing of white cover plate with frame, 12 module for modular switch/socket complete all as specified and directed.
S&F MCB SPN ‘C’ Curve 10KA, SPN 32 Amps 240 volts complete all as specified and directed .
Supply and fixing LED luminaire 600mmx600mm 35/36 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser soft glare free light complete driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
Supply and fixing LED batten luminaire surface mounted 2 feet system wattage of 10 watt, > 1000 system lumen output with life time of 50000 burning including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
Supply and fixing exhaust fan 250 mm sweep made of sturdy engineering plastic body with louvers, frame and louvers, AC single phase 50 Hz, 230 volts, including making of hole for exhaust fan and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , complete all as specified and directed.
S&F factory made epoxy powder coated load line distribution board vertical TPN 4 ways with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall suitable for universal mounting, including insulated 200 Amps rated copper bus bar, isolated neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and with 01 nos MCCB TPN 100 Amps as incomer, and conforming to IS-8623 , complete all as specified and as directed.
Supply and Installation electric water heater storage type steel body with copper inner tank capacity 25 litres and heating element upto 2 KW, BEE 5 star rated complete with all accessories as safety valve, thermostat, non return valve, connection pipes, all as specified & directed.
S&F batten/angular lamp holder, insulated body with back plate, with colour ring for light point, complete all as specified & directed.
Supply and fixing ceiling fans complete with blades, down rod and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor ( BLDC), complete all as specified and directed.
S&F MCCB 4 pole 63 Amps rating, 10 KA breaking capacity, 415 volts, adjustable type, complete all as specified and directed.
T&P for boring of holes horizontally under road/pavement/hard-standing without damaging the surface of road (minimum 1.00 meter below the road surface) for inserting GI tubing 50mm to 80mm bore for passing of U/G cable, complete all as specified and directed. (Note: GI pipe will be measured and paid separately under respective item of Sch 'A' Part-III )
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.50 mtr below normal ground level, earth plate surrounded by 15 cm thick packed layer of charcoal/coke and common salt upto 0.90 mtr depth all around the earth plate and connected to earth lead of copper strip 20x3 mm by means of bolts, nuts and washers of brass thimbles and other end of the earth lead connected to earth test terminal block and protected by galvanized iron pipe light grade 32 mm bore and water pipe 20 mm bore GI ‘medium grade’ with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES Schedule Part- (2009) complete all as specified and directed. Notes : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 50mm thick reinforced with XPM weight not less than 4 Kg/Sqm in lieu of CI cover. 2. On completion testing of earthing shall be done. If desired earth resistance is not achieved, the earthing will be redone at no extra cost to obtain the desired earth resistance.
Supply, installation, testing and commissioning outdoor type, floor mounted step down, transformer 11KV/433 volts (at no load) AC 3 phase, 50 Hz, energy efficient Level-3, conforming to IS -1180 of 2014 (ISI marked and BEE approved) capacity 100 KVA CRGO with m4 grade, core type, double copper wound, oil immersed, naturally cooled, oil neutral (ONAN), Class-A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector groupl Dyn-11 with natural brought out on secondary side (LV) and having tapings at +2.5% to +5% on HV side to be changed by means of hand operated off load tap changer gear, the maximum temperature rise should not exceed 40 degree celcius and 45 degree celcius in HV/LV windings when measured by resistance method after continuous full load run on an ambient temperature of 50 degree celcius and comprising of the following:-
(a) 01 Nos cable box chamber on HV side (primary) consisting of 03 Nos porcelain bushing with copper rod complete with nuts, bolts and washers with 01 Nos cable gland suitable for existing cable. (b) 01 Nos cable box chamber on LV side (secondary) consisting of 04 Nos porcelain bushing with copper rod complete with nuts, bolts and washers with 01 Nos cable gland 100 KVA. (c) Oil conservator tank with filter type drain plug and oil level gauge. (d) Dehydrating breather with first fill of silka gel. (e) Explosive vent, thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting hole with cap/plug with connection plate complete, air release valve plug at 04 Nos plate soil cast steel detachable rollers. (f) 01 Nos 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celcius with metal guard having maximum perimeter temperature reading indicator with setting device. (g) 02 Nos earthing terminals on tank cover to facilitate fixing of 4x25 sqmm LT cable for earthing of body, rating plate and terminal marking plate. (h) Extra bushing for natural in the LT cable box for providing independent set of earthing for natural. (i) First fill of new and unused transformer oil, IS-335 marked filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes. (j) Providing adequate size channels embedded in floor for movement of transformer. (k) Buchholtz relay complete with electric connection upto relay – 01 Nos
Deepali Designs And Exhibits Pvt Ltd (BID ID -3147842)
Sudhir Sharma Associates (BID ID -3147893)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .