Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.3 LAccepted-AOC | L1 | Accepted-AOC Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
30 Dec 2020, 6:00 pmClosed
Executive Engineer, Electrical, HEED
Executive Engineer, Harbour Engineering Electrical Division, Kamleswaram. Thiruvananthapuram
Electrification of 120 tons/day ice plant at Sakthikulangara Fishing Harbour
2020_HED_401383_1
30/HEED/2020-21/S
Open Tender
Electrical Works
Item Rate
180 days
Sakthikulangara Fishery Harbour in Kollam
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,335
Yes
₹50,000
Yes
28 Jul 2021
18 Dec 2020
4 Jan 2021
18 Dec 2020
30 Dec 2020
18 Dec 2020
Amount
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group C
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 9 w LED amps including connection etc as required.
Supply of Keselec Schreder make SID or equivalent Street light luminaire, 20W LED, IP66 optical & control gear compartment, die cast aluminium painted housing,anti UV Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 105 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K).
Supply, fabrication, conveyance and fixing 40 mm dia GI pipe with clamps made from 20 x 3 mm MS flat bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply of Exhaust fan 305mm sweep single phase, heavy duty 1400 RPM, Almonard or Equivalent in metal frame
Supply of single phase heavy duty exhaust fan dia 450mm,1400 rpm ALMONARD OR Equivalent in metal frame
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying metal shutters suitable for 305/405 mm sweep heavy duty exhaust fan
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply and fixing 3W/ 9 W LED ,BC, lamp OSRAM or equivalent
Supply of surface mounting corrosion resistant industrial lighting luminare WT550 C LED 40S CW PSU S1 PC (Philips) or equivalent 40 W LED lamp
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following ways surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board henzeal make transparent door FPVN 400 , dust protected, IP 43 , IK 09, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision for MCCB as incomer, interconnection between incomer MCCB and bus bars .4way (4+12) Double door
Supply, conveyance and fixing 40 A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Supply and fixing IP 65 Thermoplastic circuit breaker boxes 3 row 36 module 295 x 583 x 129 mm MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.4way (4+12) Double door
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, single pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, single pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing tinned 25x3mm copper strips having sufficient number of holes of 3/6mm dia as required on surface of wall using nuts & bolts as earth bus
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 865 T8 API Philips or equivalent
Supply of 3 core 185 sq mm 11KV PVC insulated and PVC sheathed XLPE power cable
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 11 kV grade above 120 sq. mm and upto 400 sq. mm size in the existing RCC/HUME/ METAL pipe as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
Supply of the standard Indoor end termination kit comprising stress cum semi conducting pad, sliding core,self bonding insulating tape, boot (with 3 core kit), earth continuity connection (with 3 core kit),earthing lug (with 1 core kit), adhesive-cum-solvent, PVC (NA) tape,Silicon grease, Aluminium crimping lug,Aluminium oxide cloth, nylon string,copper binding wire, hose clamp and bi-metallic washer
Supply of the standard outdoor end termination kit comprising stress cum semi conducting pad,cap,rain shield,self bonding Insulating tape, sliding case, leakage current collector, protective corrugated hose pipe, boot, earth continuity connection (with 3 cores only)earthing lug (with 1core kit over lay) adhesive cum solvent PVC (NA) tape,Silicon grease,Aluminium crimping lug, Aluminium oxide cloth,nylon string, copper binding wire, hose clamp and bi-metallic washer
Labour for making HT cable joints and end terminations Cable jointer
Labour for making HT cable joints and end terminations Beldar
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle MAIN panel board of size 900x1700x300mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over a coat of epoxy primer, having vertical bus bar chamber, vertical cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x4.4mm MS channel provided at the bottom as support and comprising the following.Incomer:-1.KSEB supply -800A 50KA 4Pole mechanically operated drawout type ACB with 3 overcurrent and one earth fault release with current setting range 50% to 100% In with mechanical interlock - 1 No.2. Generator supply - 630A 50KA 4Pole ACB mechanical drawout type 3 overcurrent relay with current setting range 50% to 100% In with mechanical inter lock - 1 No. Stand by Low Set E/ F Relay- 1 Nos Neutral CT Extra current limiting - 1 No Outgoings:- 630A 50KA 4Pole MCCB microprocessor based isolation duty with current setting range 50% to 100% In with shunt release - 1 No.200A TPN MCCB 35 KA -3 No with 230V shunt release Super Power capacitor Heavy duty 30 Kvar - 1 No Capacitor duty Power contactor - 1 No100A Neutral Link - 4 Nos Busbar chamber:- 800A busbar chamber with 800A TPN copper Bus Bar fitted on epoxy insulator. Switch interconnections to be done with suitably rated copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the MCCB and bus bar is also to be carried out using same size and materials used as bus bar. Internal Earth Bus shall be 40x5 mm copper stripMetering and Indication:- Smart demand controller (make Schnider or equivalent), RS 485 to Ethernet converter and SMP power supply PM7230 + EGX300 Integrated Gateway Server with port, accuracy class 1 - 1 No,Panel surface mounting 96 Sq.mm, LED Multi-function meter with communication port having three line display to read V,A,,kVA,kVAr,PF and frequency of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2Nos, 800/5 A Epoxy wound CT 3 Nos , 160/5A Bus bar mounting type tape wound C.T class1 for low set earth fault relay and 4A SP MCB C Curve (Cat B)- 6Nos. and a 32A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters for ACB / MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 38x6 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429 / 1969.
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.5C X 300 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.5C X 400 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.0 C X 240 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.5C X 185 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.5C X 120 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.5C X 35 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 3.5C X 50 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 4C X 25 sq.mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 4 core X 16 sq mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 4 core X 10 sq mm
Supply of following size 1.1 KV PVC insulated and PVC sheathed armoured aluminum cable 4 core X 6sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. Mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 400 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3 X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 16sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 10sq. mm (28mm) and 4 X 6 sq.mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose , pressure gauge and clamps including fixing it to wall as required.
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m: Pipes, cables exceeding 80 mm dia but not exceeding 300 mm dia
Supply of 120mm dia (OD 120mm and ID 103mm nominal)DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle SUB panel board of size 1250 x 1450 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over two coats of epoxy primer, having one vertical bus bar chamber, three vertical and one horizontal cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following. Incoming:- 200A, 25kA FP MCCB setted to 160A and rotory drive kit including BUC handle and shunt release with auxiliary contact- 1No Outgoings:-63 A TP MCCB 25 KA setted to 50A - 4Nos with rotary handle and 63 A two way disconnectable type neutral link suitably connected 40 A FP MCCB 16 KA setted to 32A - 1No with rotary handle and 32 A two way disconnectable type neutral link suitably connected All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) Busbar Chamber: Busbar chamber with 38X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. Protection :- ELR with CBCT current setting 0.03A to 1A with time setting - 1 No Metering and Indication:- Panel surface mounting 96 Sq.mm, LED Multi-function meter with RS 485 communication port having three line display to read V,A,,kVA,kVAr,PF and frequency of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2Nos, 100/5 A Tape wound CT 3 Nos , and 2A SP MCB C Curve -9Nos ,Phase indication lamp - 3 Nos 63A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters and quarterturn key lock for MCCB cubicles,meterchamber and front openable bolted type busbar covers,cablechamber and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 38x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 16A 1 way switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ 11 Telephone jack
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required CAT 6 RJ 45 computer data socket
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ 45 frame
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 module metal box in recess
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 2 module metal box in recess
Supplying and drawing 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing UTP four pair CAT 6 LAN cable in the existing surface/recess steel/ PVC conduit
Supply,installation,testing and commissioning of 630 KVA UNITISED SUB STATION 11000/440V, 3 phase, 50 Hz, vector Dyn11 Transformer with offcircuit tappings from +5% to -10% in steps of 2.5%, changeable on offcircuit by tap links provided ,HT& LT cable,12kv Load break switch panel,Cast resin air cooled transformer with associated protection,Electronic meter with TOD metering facility, terminal box suitable for 4 runs of PVCA cable including the base channel and steel fabricated housing. Make - INTRANS/ABB/SCHNEIDER or equivalent.
Supply installation,testing and commissioning including getting approval from KSEI of 3 phase,415 V 320kVA/256 KW Diesel Generator set with standard control panel, radiator cooled diesel engine 1500 rpm with CPCBII approved acoustic enclousure and standard accessories coupled to brushless self excited Alternator rated 320 KVA at 415 volts conforing to IS/IEC 60034-1mounted on Channel Iron Base Frame complete with Fuel Tank ,Engine moinitoring relay remote start stop provision (Prefe rred make: Engine CUMMINS, KIRLOSKAR,CATERPILLER; Alternator : BHEL EML, KIRLOSKAR, STAMFORD. Include charges for transportation of 3Ф,415V AC 50Hz 256KW/320 KVA, Diesel generator set to Sakthikulangara ,erection and commissioning of Diesel Generator set including installation over plinth, positioning,testing and commissioning includingDocumentation and getting approval from Electrical Inspectorate .
Exhaust piping with 150mm MS Class B pipe , heavy duty bend and flexible connector, MS support etc.including 2 coat heat resistant painting.
Making thermal insulation on exhaust piping 100mm thick (using glass wool & Aluminium cladding)
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 15652/2006
Supply and providing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/wall bracket fillled with fine sand, painting the frame work/floor stand including making good the damages, colour washing etc.as required.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
Supply and providing single line diagram duly framed,laminated and placed in a conspicuous location for clear vision
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Providing and fixing B class G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 50 mm dia nominal bore
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In lime mortar
Supply and filling HSD oil
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_570709.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .