Loading…
Loading…
Tender Value
₹14.8 L
EMD Value
₹14,785
Closing Date
10 Sept 2026, 11:00 am5d left
NBCC Bhawan
NBCC Bhawan
The work includes retrofitting/renovation of Store rooms, involving dismantling, Ceiling works, Tiles work, Electrical work, Bathrrom renovation
NSL/CEO/LKA/NIT/2026/937~EW551fecea53473a4156ef5b81
NSL/CEO/LKA/NIT/2026/937
Open Tender-Domestic
Miscellaneous
NBCC Bhawan
₹2,950
₹14,785
2 Sept 2026
2 Sept 2026
10 Sept 2026
2 Sept 2026
10 Sept 2026
NAME OF WORK: Repair and Renovation Work (Store Room)
SR. NO. ITEM DSR
1 Waterproofing ( Roof) 125,856.50
2 Dismentaling & Disposal 33,552.53
3 Civil Work 660,919.20
4 Ceiling works 203,370.00
5 Electrical Works 296,174.46
6 Plumbing/Sanitary works 43,778.55
7 HVAC works 114,792.00
Digitally signed by MANISH
NAME OF WORK: Repair and Renovation Work (Store Room)
S.No. DSR REF. NO. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT
1 Waterproofing ( Roof)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting,
unloading to approved municipal dumping ground, beyond 50m initial lead, for all leads including all lifts involved.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer In-
1.2 charge complete in all respect.Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications
and direction of EngineerIn-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified
proportion of approved polymer
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand
with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge
12 mm average thickness.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane on concrete roof, after preparation of surface as required,
consisting of applyng One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted
elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns), complete in all respect as per the
direction of Engineerin-Charge
2 DISMANTALING & DISPOSAL
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable
material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkats, architrave, holdfasts etc.
complete and stacking within 50 metres lead.
15.12.1 Of area 3 sq. metres and below. Each 2.00 367.20 734.40
Dismantling existing flushing cistern (PVC / CI / low level / high level / concealed type) including disconnecting
2.3 15.52 water supply connections, fittings and making good the surface, complete as per direction of Engineer-in- each 2.00 112.05 224.10
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of dismantled
material within 50 metres lead, as per direction of Engineer-in-Charge.
Dismetaling tiles work on floor and roofs laid in cement mortar including stacking material within 50 meters lead.
For thickness of tiles 10mm to 25mm
Demolish Cement concrete manually / by machanical means including disposal of material within 50 mtr lead as per
Nominal concrete 1:3:6 or rich mix (incl. equivalent mix)
Demolish Brick work manually / by machanical means including stacking of serviceable and disposal of unserviceable
material within 50 mtr lead as per direction of EIC
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means,
2.7 15.6 including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in- CUM 10.00 263.95 2,639.50
charge, beyond 50 m initial lead, for all leads including all lifts involved.
Digitally signed by MANISH
S.No. DSR REF. NO. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT
Dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of
unserviceable material and stacking of serviceable material within 50 metres lead as directed by Engineer-in-charge.
Dismantling existing stone slab flooring laid in cement mortar, stacking reusable pieces, and disposing of unwanted debris within
Total 33,552.53
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq m and under, including cutting the patch in
3.1 14.1 proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of
rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand) Sqm 20.00 547.40 10,948.00
Repair to plaster in patches, including cutting, raking out joints, preparing and replastering wall surface with white cement
3.2 14.75 based polymer modified self-curing mortar including disposal of rubbish, all complete as per direction of Sqm 20.00 670.95 13,419.00
Engineer-in-Charge.
Brick work with common burnt clay FPS( non modular) bricks of class designation 7.5 in superstructure above plinth level
up to floor V level in all shape and size in:
6.4.1 cement mortar 1:4 (1 cement : 4 coarse sand). cum 2.00 9,344.25 18,688.50
3.4 13.1 12mm cement plaster of mix :
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All
work up to plinth level
4.1.8 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). cum 5.00 6,812.00 34,060.00
Dismantling existing stone slab flooring laid in cement mortar, stacking reusable pieces, and disposing of unwanted debris within
Providing and laying Kota stone slabs over 20 mm thick base, jointed with grey cement slurry mixed with pigment to
3.7 11.26 match the shade of the slab, including rubbing and polishing complete, with base of cement mortar 1:4 (1 cement : 4
coarse sand), all as per direction of Engineer-in-Charge.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and
smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound
13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre sqm 200.00 73.95 14,790.00
3.10 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10
3.11 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 Two or more coats on new work sqm 200.00 155.90 31,180.00
Digitally signed by MANISH
S.No. DSR REF. NO. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen
and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in
recommended proportions including rounding off junction of vertical and horizontal surface.
3.12 22.3 (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in SQM 8.00 769.90 6,159.20
recommended proportion including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to
Each other with bitumen @ 1.7 kg/sqm).
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid
on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including
grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond
cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and
rubber mallet for placing the tiles gently and easily.
11.41A.3 Glazzed vetrified tiles matt/antiskid finish
Providing and fixing vetrified 1st Class Ceramic wall tiles conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by
Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of
matching shade complete.
Tiles Size : 600x1200 mm
4 Ceiling Works
GYPBOARD CEILING :- Providing and fixing false ceiling at all height including providing and fixing of frame work made of
special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as
per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm
centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other
flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other
end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to
centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having
4.1 12.45 lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels
0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long. Including jointing and finishing to a flush finish of
tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per
manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made
with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer
in Charge but excluding the cost of painting with :
12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) SQM 150.00 1,355.80 203,370.00
5 Electrical Works
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,
single core cable in surface/ recessed steel conduit as required.
a 1.7.1 2x1.5sqmm+1x1.5sqmmearth wire Per mtr. 410.56 370.00 151,906.46
c 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Per mtr. 50.00 476.00 23,800.00
Digitally signed by MANISH
S.No. DSR REF. NO. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections
but excluding modular plate etc. as required.
b 1.24.4 3 pin 5/6 A socket outlet Each 8.00 136.00 1,088.00
d 1.24.5 6 pin 15/16 A socket outlet Each 8.00 219.00 1,752.00
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess
etc. as required.
5.4 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed conduit as required.
Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of
following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5.8 8.5 LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt )
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular)
COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver
efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade,
internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified
Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum
50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per
ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/
Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing
facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor
single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135
lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted.
Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of
aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded
aluminium Body including trim with Aluminium Reflector
6 Plumbing / sanitary works
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape
6.1 17.78 including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable EACH 1.00 14,999.15 14,999.15
to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved
17.7A quality and make, including painting of fittings and brackets, cutting and making good the walls wherever
(a) White Vitreous China Wash basin size 550x400 mm with a
15 mm CP Brass single hole basin mixer
6.3 17.7 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the
waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Digitally signed by MANISH
S.No. DSR REF. NO. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT
6.5 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
6.6 17.28.2 Flexible pipe
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6
mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
18.21 Providing and fixing uplasticised PVC connection pipe with brass ions :
a 18.21.2 45 cm length
b 18.21.2.1 15 mm nominal bore Each 1.00 97.75 97.75
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply
6.9 18.9 including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent
cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
a 18.9.4 32 mm nominal dia Pipes Metre 5.00 438.60 2,193.00
b 18.9.5 40 mm nominal dia Pipes Metre 5.00 563.05 2,815.25
c 18.9.6 50 mm nominal dia Pipes Metre 5.00 794.25 3,971.25
6.10 18.16 Providing and fixing brass stop cock of approved quality complete.
18.16.2 20 mm nominal bore Each 1.00 379.20 379.20
6.11 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
18.17.2 32 mm nominal bore Each 1.00 689.95 689.95
Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931 a)
15 mm nominal bore.
18.53.1 15 mm nominal bore Each 1.00 574.30 574.30
6.13 18.74 Providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts coller and bush of approved quality and colour.
18.74.2 15mm nominal bore with 45cm length Each 1.00 121.90 121.90
Total 43,778.55
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU),
Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular
pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green
Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC
supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The
7.1 32.2 system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM)
warranty both compressor
and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International
Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS
12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door
Digitally signed by MANISH
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT lalit Kala Academy.pdf
Tender Document
SCC lalit Kala Academy.pdf
Tender Document
list of make.pdf
Tender Document
Technical circular upto 33 amendment.pdf
Tender Document
updated forms.pdf
Tender Document
ITT.pdf
Tender Document
GCC 2026 upto 2nd amendment.pdf
Tender Document
BoQ Store Room.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .