Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation and commissioning of Hi wall inverter Split Air Conditioning Machines for the newly constructed residential building of his lordship Honble Mr. Justice S.G Chattapadhya, Judge high court of Tripura at Durjoynagar Airport road
2022_CEPWD_34474_1
89/EE/DNIeT/MECH.DIVN/AGT/ 2022
Open Tender
Electrical Works
Works
60 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹2,660
14 Feb 2023
25 Nov 2022
5 Dec 2022
25 Nov 2022
5 Dec 2022
25 Nov 2022
Amount
Providing of Split type Hi- wall 1.5 TR (4500 K cal/hr ± 2%) split AC machine inverter Compressor technology Operating on non-CFC refrigerant (R-410/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS: 1391(part-II) specification(Evaporator & Condenser must have copper pipe) suitable for operation on 230 Volt ± 10 % , not less than 3(three) Star rating (2019 standard), 50 Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.(Haier/Hitachi/ Blue Star/ Carrier/Voltas make ). i) 1.5 TR
Providing of Split type Hi- wall 2.00 TR(6000 K cal/hr ± 2%) split AC machine inverter Compressor technology Operating on non-CFC refrigerant (R-410/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS: 1391(part-II) specification(Evaporator & Condenser must have copper pipe) suitable for operation on 230 Volt ± 10 % , not less than 3(three) Star rating (2019 standard), 50 Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. (Haier/Hitachi/ Blue Star/ Carrier/Voltas make ). j) 2.00 TR
Standard installation of 1.5 TR/2.00 TR capacity High wall Split type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation of copper pipes and also providing electrical 3 pin 16 amp top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge.
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line with installation and necessary wiring between indoor and outdoor unit beyond the standard length.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts/cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between MCB to indoor/outdoor. A) 3C X 2.5 Sq. mm Copper Cable.
R.P.ELECTRONICS
Eastern Commerce
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_35007.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .