Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹39.9 L+₹19,007.55 (0.48%)Rejected-AOC | L2 | Rejected-AOC Rejcted | |
| 3 | L3₹41.9 L+₹2.1 L (5.38%)Rejected-AOC | L3 | Rejected-AOC Rejcted | |
| 4 | L4₹44.9 L+₹5.1 L (12.9%)Rejected-AOC | L4 | Rejected-AOC Rejcted |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
31 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS c o 56 APO
PROVN OF THREE VOLTAGE STABLISER, 10 LED SECURITY LIGHTS 50 W ALONGWITH CONNECTED ACCESSORIES AT 316 FD REGT, EXTERNAL WATER SUPPLY TO BLDG NO T11, T34 AND T55 FOR INF BN, 10 EXHAUST FAN WITH ALL
2020_MES_383646_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
270 days
Baramulla
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹86,000
Yes
14 Jan 2021
5 Oct 2020
2 Nov 2020
5 Oct 2020
31 Oct 2020
19 Oct 2020
60 days
Amount
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/ex fan point controlled by one 5 Amps switch one way
All as per sr item no. 2 above but One 3 pin 5 Amp switch socket outlet on independent board
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. Complete all as specified and directed by Eng-In-Charge.
S&F in repair switch piano Flush type, single pole 6 amp 240 volts, Complete all as specified and directed by Eng-In-Charge. Make: Anchor / Bajaj / Cona
S&F in repair switch piano Flush type, single pole16 amp 240 volts, Complete all as specified and directed by Eng-In-Charge. Make: Anchor / Bajaj / Cona
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type Complete all as specified and directed by Eng-In-Charge. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type Complete all as specified and directed by Eng-In-Charge. Make : Anchor / Bajaj / Cona
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store. Complete all as specified and directed by Eng-In-Charge.
S&F in repair stepped type modular fan regulator ,120 W 2 module. Complete all as specified and directed by Eng-In-Charge. Make: MK/Anchor (Roma)/ABB
Supply and fixing ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body. Complete all as specified and directed by Eng-In-Charge.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting Complete all as specified and directed by Eng-In-Charge. Make : Anchor / Cona / Bajaj
S & F MCB, SP 6-32 Amps 415 Volts Gold plus MCB B Curve. Complete all as specified and directed by Eng-In-Charge. Make : Havells Indo Asian / Standard.
S&F LED Lamp 9 W. Complete all as specified and directed by Eng-In-Charge. Make : Havells cat No. LHLDEUECNL8R009 or equivalent.
S&F office Pendent light. Complete all as specified and directed by Eng-In-Charge.
S&F decorative ultra slim aluminium LED lighting fixture 22 W with high lumen output, environmental friendly, energy efficient ready to use pack. Make:- Havells HEXBTP7IN1S022 or equivalent.
S&F MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA, Complete all as specified and directed by Eng-In-Charge.
S&F MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA, Complete all as specified and directed by Eng-In-Charge.
S & F Exhaust fan Non Metallic Range 250 mm. Complete all as specified and directed by Eng-In-Charge. Make: Havells, Code:8414 or equivalent.
S & F OFF LOAD CHANGEOVER SWITCH 200 Amp capacity With enclosure Rated Voltage - 415V-AC 50HzType - FP Complete all as specified and directed by Eng-In-Charge., Make : INDO ASIAN Code -OFFPO200 or equivalent.
M&L for XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade of cross sectional area 50 sq. mm 3.5 core. Complete all as specified and directed by Eng-In-Charge.
M&L for XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade of cross sectional area 35 sq. mm 3.5 core. Complete all as specified and directed by Eng-In-Charge.
M&L for Sub main wiring with 2 runs of 6 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 6 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring Complete all as specified and directed by Eng-In-Charge. Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth along with PVC conduit will be measured as one length.
S & F street light panel complete with three phase incomer and 200 Amp rating alumiunm bus bar , Frame size 2'x2' , incoming MCCB 100 Amp, Make : Havells or equivalent. Complete all as specified and directed by Eng-In-Charge.
S & F in repairs MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Eng-In-Charge. (Make:- Schneider as per cat part- NBKRESNDD08 or equivalent in Havell's or Standard)
S & F in repairs MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Eng-In-Charge. (Make:- Schneider as per cat part- NBKRESNDD08 or equivalent in Havell's or Standard)
S & F MCB, DP 32/40 Amps 415 Volts Gold plus MCB C Curve. Complete all as specified and directed by Eng-In-Charge. Make : Havells/ Indo Asian / Standard
S& F VTPN Vertical type distribution boards(MCCB Incomer) 4 way (4+12 ) module, Complete all as specified and directed by Eng-In-Charge. Make:-L&T or equivalent.
M&L for XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade of cross sectional area 25 sq. mm 3.5 core . Complete all as specified and directed by Eng-In-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes/cables etc and not exceeding 10 sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in hard/ dense soil. Complete all as specified and directed by Eng-In-Charge.
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 Cm thick, Complete all as specified and directed by Eng-In-Charge.
Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, Complete all as specified and directed by Eng-In-Charge.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. Complete all as specified and directed by Eng-In-Charge.
M&L for Sub class "B" bricks laid dry width wise across the line of cable in treanchs as cable protection. Complete all as specified and directed by Eng-In-Charge.
S&F voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 200 KVA. Complete all as specified and directed by Eng-In-Charge.
S&F voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 160 KVA. Complete all as specified and directed by Eng-In-Charge.
S&F voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 50 KVA. Complete all as specified and directed by Eng-In-Charge.
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts check nuts and washers of galnanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No-3 of SSR- Part-1 connected to earth strip all as specifed or indicated including testing on completion and necessary excavation and earth work in any type of soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm diia meduim grade watering pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer. Note : The rate is inclusive of necessary earth work, RFR and removal etc Complete all as specified and directed by Eng-In-Charge.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc. Complete all as specified and directed by Eng-In-Charge.
Supply & laying of UG cable LT 1100 volts grade XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor cross section area 70 Sqmm 3.5 core laid in trenches or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing. Make: Havells/CCI/Gloster/Finolex. Complete all as specified and directed by Eng-In-Charge.
Supply install, testing & commossionig of feeder & piller box outdoor /indoor type factory made dust & vermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee section 100x50x6mm (Fram) double door frant/ reare with opening & loking arrangement floor /wall mounted Bus Bar chamber (enclosed) with suitable size of 200 Amp aluminium Bas bar fixed on post imulated spray painting with two coates of synthetic enemal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on pcc blank fixed with granted bolts nuts & washers complete in all respect & including the following :-- (a) MCCB 4 Pole, 415 Volts 200 Amp with with 25 KA bracking capacity - 01 Nos(b) MCCB 4 Pole,415 Volts 100 Amp with with 25 KA bracking capacity - 02 Nos(c) Neon indicator lamp RYB - 01 Set (d) Digital volt meter 0 to 400 Volts with ss - 01Nos (e) Digital Ammeter 0 to 200 Amps with s/s & CT 's - 01 Nos. Complete all as specified and directed by Eng-In-Charge.
Supply install, testing & commossionig of feeder & piller box outdoor /indoor type factory made dust & vermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee section 100x50x6mm (Fram) double door frant/ reare with opening & loking arrangement floor /wall mounted Bus Bar chamber (enclosed) with suitable size of 200 Amp aluminium Bas bar fixed on post imulated spray painting with two coates of synthetic enemal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on pcc blank fixed with granted bolts nuts & washers complete in all respect & including the following :-- (a) MCCB 4 Pole, 415 Volts 200 Amp with with 25 KA bracking capacity - 01Nos(b) MCCB 4 Pole,415 Volts 100 Amp with with 25 KA bracking capacity - 02 Nos(c) Neon indicator lamp RYB - 01 Set (d) Digital volt meter 0 to 400 Volts with ss - 01Nos (e) Digital Ammeter 0 to 200 Amps with s/s & CT 's - 01Nos. Complete all as specified and directed by Eng-In-Charge.
S&F 40 mm bore GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in floors or fixed to walls. Complete all as specified and directed by Eng-In-Charge.
S&F 25 mm bore GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in floors or fixed to walls.Complete all as specified and directed by Eng-In-Charge.
S&F 20 mm bore GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in floors or fixed to walls.Complete all as specified and directed by Eng-In-Charge.
S&F 15 mm bore GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in floors or fixed to walls. Complete all as specified and directed by Eng-In-Charge.
Supply and Fixing Gun metal globe or gate valve non rising spindle heavy duty with iron wheel head, screwed both end for connection GI pipes complete all as specified for the following sizes of pipe (ISI Marked) including desmentling of unserviceable Complete all as specified and directed by Eng-In-Charge. (a) GI tubing 20 mm dia bore
All as per item No. 49 above but valve 25 mm dia bore
All as per item No. 49 above but Valve 40 mm dia bore
S&F cast iron sluice valve class PN 1.6 CONFORMING TO IS-14846, ISI marked with brass spindle complete with flanged ends incl necessary nuts, bolts, washers and rubbers gaskets, 3mm thick heavy and iron wheel complete with jointing materila incl taking out old unserviceable sluice valve of 80 mm dia size. Complete all as specified and directed by Eng-In-Charge.
Cutting of existing GI pipe line of size upto 100 mm dia and inserting new pipe line including all fittings complete all as specified & directed by Engr-in-charge.
S & F in repairs MCB DB 16 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. (Make:- Schneider as per cat part- NBKRESNDD08 or equivalent in Havell's or Standard)
S & F in repairs MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. (Make:- Schneider as per cat part- NBKRESNDD08 or equivalent in Havell's or Standard)
S & F MCB DP 63 Amps, 240 Volts, MCB B Curve Complete all as specified and directed by Eng-In-Charge. Make : Havells/ Indo Asian / Standard.
S&F plain galvanised steel sheet 0.63 mm thick in ridges, hips, valley, gutters and straight flashings (length and breadth 0.6 mx1.2m) with gauge of zinc coating fixing with screws , nut and bolts. Complete all as specified and directed by Eng-In-Charge.
S & F plain galvanised steel sheet 0.63 mm thick in ridges, hips, valley, gutters and straight flashings (length and breadth 0.6 mx0.6m) with gauge of zinc coating fixing with screws , nut and bolts
S & F plain galvanised steel sheet 0.63 mm thick in ridges, hips, valley, gutters and straight flashings (length and breadth 0.6 mx0.3m) with gauge of zinc coating fixing with screws , nut and bolts
Supply and fixing of off load change over switch 63 Amp , , Make : Havells Cat No-OFFP0063 or equivalent in Standard. Complete all as specified and directed by Eng-In-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5 core. Complete all as specified and directed by Eng-In-Charge.
Supply and install water, storage heater type of capacity 25 Litrs BEE 5 star, 230 volts, AC, 50 Hz including PVC connection of size 15 mm dia & 450 mm long for hot water complete with both end complete all as specified and directed by Engr-incharge. Make :- Havells GHWAPTTWHO25 or equivalent approved by GE.
S&F ENDURA CITYLINER NEX GEN New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP66 protection and impact resistance of IK07 complete all as specified and directed. Make:- Havells cat part No ENDURACITYLINERNEXGENSL48WLED757SASYBOPC or equivalent in CG/Philips/Bajaj.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 3 core, 1100 Volts grade. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing GI pipe, bracket for street light fittings made out of 32/40 mm dia GI Pipe light grade 1.2m long bent to required angle/shappe with and including necessary clamps of 03 sets necessary nuts, bolts & washers of suitable size and painting with two coats of aluminium paint over a coat of red oxide primer. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing Turbo Force SP Exhaust fan 300 mm sweep 230 volts, 900 rpm AC connecting up including provision of cable from ceiling rose/ connector to fan Complete all as specified and directed by Eng-In-Charge.
S&F exhaust fan AC single phase 230/240 volts of size 450 mm sweep with louver. Complete all as specified and directed by Eng-In-Charge.
S& F white cover plate with frame, 1 Moudule for bell point. Complete all as specified and directed by Eng-In-Charge.
Supply, installation, testing & commissioning of 80 HP FASD Starter at water point No-01 at Baramulla Mil Stn. The specification are as under:- i. MNX 110 main contractor of L&T make or equivalent ii. MNX 110 star/Delta contractor of L&T make or equivalent iii. Timer assembly iv. Overload relay: MN5 or equivalent v. Under voltage relay vi. On/off push button. The stator shall be complete with all accessories with internal wiring, thimbling and shall be complete in all respects. Complete all as specified and directed by Eng-In-Charge.
Suply, installation, testing and commissioning of (RO)Reverse Osmosis +Ultra Voilet purifying system for capacity of 150 Ltrs/Hr, Duty cycle 16 Hours (max) over and including connections complete all as directed,comprising of the following:- (a) Prefilteration (b) Granular Activated Carbon Filter (c) Carbon block filter (d) RO Membrane (e) Ultra violet rays (f) Post carbon filter (g) Dosing system of stable capacity to dose anti sealent chemical to protect the scaling formation on RO membrane of RO plant , complete all as specified and directed.by Engr in Charge. Make :- AQUAFRESH ASSEMBLED /Aquaguard/Eureka Forbes/Livepura/Dr Water/Sathya Sai Aqua Pura Services.
Supply & fixing rotational moulded polythene water storage tanks triple layers(Cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of 500 Ltrs capacity Complete all as specified and directed by Eng-In-Charge.
Supply & fixing rotational moulded polythene water storage tanks triple layers (Cylinderical vertical with closed top) hoisted and fixed in position specified in SSR Part-I of 1000 Ltrs capacity with angle iron staging Complete all as specified and directed by Eng-In-Charge.
S&F invertor type refrigerator of capacity 212 Ltrs. alongwith inbuilt stabilizer, single door, 5 Star rated, toughened glass, top freezer & direct cool defrosting type refrigerator direct electric driven (single phase). Complete all as specified and directed by Engr in Charge. Make :- Samsung RR22N385YB8/HL, 212 L 5 star or other equivalent approved by GE.
S&F sheet metal enclosures with socket plug top and MCBs having single pole and nutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240V Complete all as specified and directed by Engineer-In-Charge.
M&L for bib taps, cast copper alloy with crutch handle screwed down screwed for iron pipe or for brass ferrule and fixed for 20mm dia. Complete all as specified and directed by Engineer-In-Charge.
S&F for stop valves cast copper alloy screwed down high pressure with crutch handle screwed both ends for iron pipe or for unions and fixed for fancy type chromium plated for bor dia of 20mm. Complete all as specified and directed by Engineer-In-Charge.
S&F PVC connection but size 900mm long for hot/cold water complete with bath end Complete all as specified and directed by Engineer-In-Charge.
Supply, install and commissioning of kero based water heating plant of capacity 500 Liters alongwith complete connected/requirement accessories for opearating kero based water heating plant with full effieciency Complete all as specified and directed by Eng-In-Charge. (Note:- Quoted rate is inclusive cost of foundation)
S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastec ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) etc Complete all as specified and directed by Engineer-In-Charge.
M&L for lagging on 20mm internal dia pipe all round with 25 mm thick bonded mineral wool pre-formed 'SNAP ON' pipe section of density of 144 Kg/Sqcm confirm to IS 9842 including providing with chicken mesh wire netting 25 gauge 20 mm mesh etc Complete all as specified and directed by Engineer-In-Charge.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm Complete all as specified and directed by Engineer-In-Charge.
M&L for PCC 1:3:6 type C-2 40 mm graded in foundations, filling and mass concrete Complete all as specified and directed by Engineer-In-Charge.
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting, etc confroming, to Fe. 290 Gde E-165 Complete all as specified and directed by Engineer-In-Charge.
S&F 6mm thick Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming with riveted, bolted or welded attachment confirming to Fe-290 (Gde E-165) etc Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new previously untreated steel surfaces of any despcription, over 10 cm width or girth, otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. Complete all as specified and directed by Engineer-In-Charge.
Supply and fixing switch socket combination 5A/16 A 5 in 1, flush type Complete all as specified and directed by Eng-In-Charge.
M&L for point wiring with 2.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC concealed conduit 25 mm dia medium grade ISI marked with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) surface type, for 3 pin socket outlet, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc and continous PVC insulated and unsheathed 2.5 Sqmm copper conductor cable multistrand as earth wire, Complete all as specified and directed by Eng-In-Charge.
M/S SAHANI ASSOCIATES
M/S KULBIR SINGH SODHI AND CO
m/s mohd rafiq lone
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .