Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC | ₹2.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.8 LRejected-Finance THRISSUR KERALA | THRISSUR | KERALA | 679105 | ₹2.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹2.9 LRejected-Finance | ₹2.9 L | L3 | Rejected-Finance L3 |
| 4 | L4₹2.9 LRejected-Finance | ₹2.9 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | SHARJAS A L4 | Johnson AV L1 | J R Associates Electrical Engineers and Contractors L3 | SURESH K S L2 |
|---|---|---|---|---|---|---|---|
| 1.00Electrical | |||||||
| 1.00 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 10 | point | 1,000 ₹10,000 | 1,050 ₹10,500 | 946.05 ₹9,460.50 | 936.49 ₹9,364.90 |
| 1.00 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 6 | point | 950 ₹5,700 | 975 ₹5,850 | 882.96 ₹5,297.76 | 874.04 ₹5,244.24 |
| 1.00 | 90.2.1.10:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Medium point | 8 | point | 1,100 ₹8,800 | 1,140 ₹9,120 | 1,030.96 ₹8,247.68 | 1,020.55 ₹8,164.40 |
| 1.00 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | 4 | each | 350 ₹1,400 | 520 ₹2,080 | 472.84 ₹1,891.36 | 468.06 ₹1,872.24 |
| 1.00 | 90.2.1.11:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Medium Point. | 12 | point | 1,500 ₹18,000 | 1,745 ₹20,940 | 1,575.26 ₹18,903.12 | 1,559.35 ₹18,712.20 |
| 1.01 | 90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point | 8 | each | 450 ₹3,600 | 695 ₹5,560 | 630.46 ₹5,043.68 | 624.09 ₹4,992.72 |
| 1.01 | OD328225/2025-2026:supply and providing ,fixing 240 v ,400mm size wall mounting fan (mettal body) with standered accessories and giving connections as required (havells/crompton/bajaj/usha) | 8 | no | 3,200 ₹25,600 | 3,130 ₹25,040 | 2,821.58 ₹22,572.64 | 2,793.09 ₹22,344.72 |
| 1.01 | OD328226/2025-2026:Supply Conveyance, installation, testing and commissioning of 30W LED street light fitting,
light output greater than 105lumen/W 4000-6000 K with IP 65 protection, power factor greater
than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast
Powder coated housing, acrylic/glass cover complete with THD less than 10%, duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for
maintenance (3 year warranty) and giving connection etc as required. | 2 | no | 3,000 ₹6,000 | 1,925 ₹3,850 | 1,737.41 ₹3,474.82 | 1,719.86 ₹3,439.72 |
| 1.01 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps | 3 | metre | 200 ₹600 | 715 ₹2,145 | 645.75 ₹1,937.25 | 639.23 ₹1,917.69 |
Tender Value
Refer Docs
EMD Value
₹7,945
Closing Date
16 Oct 2025, 5:00 pmClosed
AEE SUB DIVISION OLK
Office of Assistant Executive Engineer LSGD Sub Division Ollukkara BP
Annual Plan-2025-26 Electrification of Day Care first Floor-S0129/26 OLLUKARA BP General Electrical Work-electrification
2025_LSGD_806824_1
129/AE/OLK/2025-26
Open Tender
Electrical Works
180 days
OLLUKKARA BP
Please refer Tender documents.
8 documents required · 8 mandatory
₹705
Yes
₹7,945
15 May 2026
8 Oct 2025
18 Oct 2025
8 Oct 2025
16 Oct 2025
8 Oct 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1344221.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1344221.xls
BOQ • 0.35 MB
viewnitdaycare.pdf
Tender Documents • 0.02 MB
fot.pdf
Tender Documents • 0.03 MB
affidavit.pdf
Tender Documents • 0.02 MB
epaymentform.pdf
Tender Documents • 0.01 MB
paedited.pdf
Tender Documents • 0.38 MB
viewsbddayc.pdf
Tender Documents • 1.63 MB
integrity.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid