Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.3 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹27.6 L+₹2.3 L (9.03%)Rejected-Finance | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹27.9 L+₹2.6 L (10.1%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹28.6 L+₹3.3 L (13.2%)Rejected-Finance 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹29.1 L+₹3.8 L (14.9%)Rejected-Finance | 5 | Rejected-Finance Not L-1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Sept 2020, 6:00 pmClosed
Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINTENANCE OF INTERNAL WIRING FITTINGS FIXTURES AT ABE PARK DAD DSC ACCN AND NAD RESIDENTIAL AREA UNDER AGE EM OF GE ND VISAKHAPATNAM
2020_MES_366547_1
8901
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE ND Visakhapatnam
₹80,000
Yes
11 Nov 2020
5 Aug 2020
8 Sept 2020
5 Aug 2020
3 Sept 2020
27 Aug 2020
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
All as per item No. 2 above but suitable for 5 Amps socket point on independent board.
All as per item No. 3 above but in same board
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 2.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 2.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for power socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for power socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point controlled by two nos two way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through existing concealed PVC conduit including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
All as per item No. 8 above but suitable for 5 Amps socket point on independent board.
All as per item No. 8 above but in same board
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through existing concealed PVC conduit including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One power socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through existing concealed PVC conduit including modular terminal boxes and white cover plate with frame and provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point controlled by two nos, two way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for sub main wiring with 5 runs of single core 1100 volts grade, PVC insulated, 10.0 Sqmm, drawn through and including 25mm dia PVC conduit and conduit accessories including provision of 1 run of 10.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 6 runs of 10.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, 6.0 Sqmm, drawn through and including 20mm dia PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, 4.0 Sqmm, drawn through and including 20mm dia PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular switch single pole, 1 way, 16 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, omplete all as specified and directed.
S & F modular bell push flush type 5 Amps
S & F piano type bell push flush type 5 Amps
S & F Calling bell, AC, 230 Volts, single pole
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
S & F Switch Piano, flush type, single pole, one way, 6 Amps, 230 Volt complete all as directed.
S & F Switch Piano, flush type, single pole, two way, 6 Amps, 230 Volt complete all as directed.
S & F switch socket combination multipurpose 3 pin, 5 Amps controlled by one switch 5Amps flush type complete all as specified and directed.
S & F switch socket combination, multipurpose, 2 in 1, 3 Pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 volts, complete all as specified and directed
S & F electronic fan regulator, socket type complete all as specified and directed.
S & F MCB, SPN, 40 Amps
S & F MCB, SP, 5 to 32 Amps
S & F in repairs MCB DB, SPN, 12 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCB DB, SPN, 8 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCB DB, SPN, 4 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCB DB, TPN, 4 way, double door, 415 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F MCB, Four Pole, 63 Amps
S & F IsolatorB, Four Pole, 100 Amps, 415 Volts
S & F in repairs MCB DB, Vertical TPN, 8 way, double door, 415 Volts with 200 Amps rated bus bar suitable for incomer 160 Amps TPN MCCB (01 No) 25 KA with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
Taking down existing light fittings of any type and refixing in the same location with new PVC flexible copper wire of suitable size complete all as directed.
Taking down existing ceiling fan of any type and sweep from any position and refixing the same in original position after necessary over hauling / servicing, cleaning for dust, grease including replacement of defective spare parts as required and strip opening and winding with suitable gauge copper wire and applying one coat of synthetic enamel paint (spray painting) complete all as specified and directed by the Engineer-in-Charge. [Note:Quoted rate is deemed to be inclusive for writing MES Nos on the fan as per existing]
M & L for cutting, chasing, pinning in and making good disturbed surfaces in CM 1:3 for concealed wiring as required to the satisfaction of Engineer-in-Charge
M & L for cutting of existing hard standing, chequered tiles and concrete surfaces for laying of GI earth wire including making good disturbed surfaces in CM 1:3 or PCC 1:2:4, type B-0 to the satisfaction of Engineer-in-Charge
S & F in repairs Rigid non-metallic PVC conduit of 20mm dia complete with accessories such as junction boxes, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories, lock nuts, saddles, pipe hooks, etc for drawing telephone / TV cables complete all as specified and directed.
S & F in repairs Rigid non-metallic PVC conduit of 25mm dia complete with accessories such as junction boxes, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories, lock nuts, saddles, pipe hooks, etc for drawing telephone / TV cables complete all as specified and directed.
Supply and replace fan clamps with nuts, bolts and washers suitable for ceiling fans of any sweep
Supply and replace mild steel powder coated down rod 18" long suitable for hanging ceiling fans
Supply and replace mild steel powder coated down rod 48" long suitable for hanging ceiling fans
S & F in repairs PVC box of size 250x250x155mm shock proof, rust proof, with provision for cable entry at bottom and/or sides, weather proof suitable for LT 1 Phase KWH meter including taking down and refixing energy meter with all connections complete all as specified and directed
Taking down old DBs housing MS box of size (Appx 0.8mx0.85mx0.4m) from the existing location and making good the opening / surface to flush with existing wall with necessary brick work in CM 1:6, rendering in CM 1:4 and finishing the surfaces to match with adjoining surfaces complete all as directed
S & F DLP-s UPVC Trunking system with accessories of size 100x50mm including fixing arrangements to walls / ceiling including removing old PVC tray complete all as directed by the Engineer-in-Charge.
S & F LED tube light fittings, 2 feet long of 900 to 1000 lumens of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED Bulkhead light of 900 to 1000 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down existing light fittings of any type and making good to the disturbed surafces to match with existing complete all as specified and as directed by the Engineer-in-Charge.
S & F Square recessed mounted LED light (2'x2') of minimum 3600 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light LED type of minimum 2500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 10 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 6 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
S & F Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
SRI SAI VAGDEVI BUILDERS
koneru enterprises
SAI SAMPATH ELECTRICAL AND ENGINEERING
VARADHI ENTERPRISES
venkata sai constructions
SAI POWER SYSTEMS
MVV Prasad
R AND A ASSOCIATES ENGINEERS CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .