| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹2.6 Cr Quoted ₹2.8 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.8 CrRejected-AOC CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | ₹2.8 Cr | L2 | Rejected-AOC Rejected |
| 3 | L3₹2.8 CrRejected-AOC EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹2.8 Cr | L3 | Rejected-AOC Rejected |
| 4 | L4₹2.9 CrRejected-AOC 121004 | ₹2.9 Cr | L4 | Rejected-AOC Rejected |
| 5 | L5₹2.9 CrRejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹2.9 Cr | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | Suprisons L6 | Powertech Engineers L3 | VIJAY CONSTRUCTIONS L1 | Neptune Engineers and Builders L4 | SHAIJAL T M L5 | Classic Builders L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each of size complete all as specified and directed. | 412 | Each | 200 ₹82,400 | 180 ₹74,160 | 100 ₹41,200 | 200 ₹82,400 | 250 ₹1.0 L | 190 ₹78,280 |
| 2.00 | Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area not exc 1.5 sqm each of size complete all as specified and directed. | 119 | Each | 175 ₹20,825 | 150 ₹17,850 | 200 ₹23,800 | 190 ₹22,610 | 150 ₹17,850 | 225 ₹26,775 |
| 3.00 | S&F 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. | 1.15 | Cum | 90,000 ₹1.0 L | 90,000 ₹1.0 L | 65,000 ₹74,750 | 63,500 ₹73,025 | 70,000 ₹80,500 | 70,000 ₹80,500 |
| 4.00 | S&F 2nd class hard wood, 35mm thick factory made door shuttersPlain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treatedcomplete all as specified and as directed. | 93 | Sqm | 3,000 ₹2.8 L | 2,900 ₹2.7 L | 2,250 ₹2.1 L | 2,500 ₹2.3 L | 2,400 ₹2.2 L | 2,250 ₹2.1 L |
| 5.00 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions | 270 | Rm | 750 ₹2.0 L | 700 ₹1.9 L | 825 ₹2.2 L | 1,050 ₹2.8 L | 600 ₹1.6 L | 900 ₹2.4 L |
| 6.00 | Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions | 74.6 | Sqm | 3,600 ₹2.7 L | 3,500 ₹2.6 L | 2,800 ₹2.1 L | 3,550 ₹2.6 L | 2,820 ₹2.1 L | 3,000 ₹2.2 L |
| 7.00 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples, chains hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified. | 50 | Kg | 140 ₹7,000 | 130 ₹6,500 | 150 ₹7,500 | 135 ₹6,750 | 150 ₹7,500 | 140 ₹7,000 |
| 8.00 | M&L for cutting holes in brick walls (not exc half brick) built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified. | 180 | Each | 120 ₹21,600 | 100 ₹18,000 | 75 ₹13,500 | 195 ₹35,100 | 100 ₹18,000 | 70 ₹12,600 |
| 9.00 | M&L for Preparing surfaces of steel and iron work, new or old, small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each, and treated with tar or coal tar black paint treating complete all as specified. | 2 | 100 Nos | 400 ₹800 | 300 ₹600 | 1,000 ₹2,000 | 900 ₹1,800 | 400 ₹800 | 100 ₹200 |
| 10.00 | S&F butt hinges 100mm Stainless steel hinges complete all as specified | 108 | Each | 110 ₹11,880 | 100 ₹10,800 | 75 ₹8,100 | 100 ₹10,800 | 120 ₹12,960 | 90 ₹9,720 |
Updated dates
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
25 Mar 2026, 6:00 pmClosed
SHRI R K SINGH IDSE
CWE (NW) KOCHI KOCHI
SPECIAL REPAIRS TO BLDG 202, 202A, 202B, 202C, 202D AND 255 BLOCK OF NAVY CHILDREN SCHOOL KOCHI
2026_MES_753254_1
CWE(NW)KOCHI/81631
Open Tender
Civil Works
240 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹2,000
GE (NW) KOCHI
₹3.5 L
17 Apr 2026
18 Feb 2026
27 Mar 2026
18 Feb 2026
25 Mar 2026
11 Mar 2026
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each of size complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area not exc 1.5 sqm each of size complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F 2nd class hard wood, 35mm thick factory made door shuttersPlain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treatedcomplete all as specified and as directed.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples, chains hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified.
M&L for cutting holes in brick walls (not exc half brick) built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified.
M&L for Preparing surfaces of steel and iron work, new or old, small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each, and treated with tar or coal tar black paint treating complete all as specified.
S&F butt hinges 100mm Stainless steel hinges complete all as specified
S&F Butt hinges,100mm heavy weight, cold rolled mild steel, and fixed complete all as specified.
M&L for 150mm size aluminium handle (ISI Marked) cast type anodized, fixed complete all as specified and directed.
M&L in repair for 150mm size aluminium handle (ISI Marked) cast type anodized, fixed complete all as specified and directed.
M&L for 150mm size aluminium tower bolt (ISI Marked) anodized, fixed complete all as specified and directed.
M&L in repair for 150mm size aluminium tower bolt (ISI Marked) anodized, fixed complete all as specified and directed.
S&F Floor door stopper of Aluminium alloy body and tongue , anodised with hard drawn steel spring, fixed in steel (overall length of cover plate 140mm)
S&F in repair Floor door stopper of Aluminium alloy body and tongue , anodised with hard drawn steel spring, fixed in steel (overall length of cover plate 140mm)
S&F 250mm long Aluminium alloy, anodised, sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
S&F in repair 250mm long Aluminium alloy, anodised, sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
Demolition of cement concrete unreinforced in any Position not otherwise specifically provided for.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified.
M&L for PCC, 1:2:4 type B1 using 20mm graded stone aggregate 25mm thick, as in flooring complete all as specified.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors with approved Pattern over cement sreed 15 mm thick in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per item No 24 here in before but as in skirting over cement backing coat 10mm thick in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M& L for glazed Ceramic tiles in vertical surface each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10 mm thick in CM 1:4 on fair face of brick work or concrete surface set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed
Demolition of stone slabs of any description or thickness laid bedded in any motar complete all as specified and directed
M & L for 20mm thick granite stone slab( Jet black )over cement screed 15mm thick in CM 1:4 over RCC Slab complete all as specified and directed .
Providing edge moulding to 18-20mm thick Granite stone of counter vanities etc. including machine polishing to edge to give high gloss finish etc. complete
S&F powder coated anodised aluminium frame windows, ventilator with one or more rebates including joining cleat for fixing etc. complete (Sliding type/Side hung type) complete all as specified and directed
S&F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21, 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F Anodised aluminium powder coated (not less than 50 micron) any colour window and ventilator shutter, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S&F Aluminium powder coated sliding type window with 4mm thick plain sheet glass including provision of airtight heading and handling arrangement complete with following section :- (i) Outer frame 50.8x25.40x1.5mm (ii) 2 Track frame 43.66x22x1.22mm (iii) Shutter fame 31.801x14.50x1.20mm (iv) Shutter interlock 31.80x20.50x1.20mm
S&F Aluminium powder coated sliding type window with 4mm thick plain sheet glass including provision of airtight heading and handling arrangement complete with following section :- (i) Outer frame 50.8x25.40x1.5mm (ii) 3 Track frame 43.66x22x1.22mm (iii) Shutter fame 31.801x14.50x1.20mm (iv) Shutter interlock 31.80x20.50x1.20mm
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S & F Powder coated anodised aluminium 5mm dia hexagonal channel for grill fixed to aluminium frame with aluminium bidding complete all as specifed.Make : JINDAL or equivalent section from HINDALCO/INDALCO/MS AJIT IND PVT LTD
S & F sheet glasses, plain 4.00mm thick glazing all with aluminum beading & rubber gaskets etc exc 0.5 sqm in each pane fixed in alumuninum window, ventilator complete all as specified and directed.
S & F Figured glasses, plain 4.00mm thick glazing all with aluminum beading & rubber gaskets etc not exc 0.5 sqm in each pane fixed in alumuninum window, ventilator complete all as specified and directed.
S&F 10mm thick toughen glass for aluminium door complete all as specified
Dismantling structural steel work including doors, gates but excluding framed truss etc
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement
Demolition Brickwork or stone/ boulder masonry, built incement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete.
M&L for precast cement concrete block masonry type C1, 1:3:6 (using 20mm graded aggregate) with solid blocks exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
M&L for Rendering 10mm thick in CM 1:6 internally on brick or concrete surfaces of wall finished even and smooth complete all as specified.
M&L for cement Plaser in two coats 8mm thick in CM 1:4 using WPC over 12mm thick in CM (1:6) on external surfaces complete all as specifeid. Approved WPC complete all as specified and as directed. Note : WPC shall be measured separate item
Supply only Liquid water proofing compound.
M & L for preparation new wall surfaces and applying Two coat of distemper oil emulsion over a coat of alkali resistant primer and 1.50mm thick wall care putty complete all specified and directed Note Application of paint, primer and wall care putty shall be as per manufacturers instruction
M&L for preparation new plastered external wall surfaces and apply Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over over 1.50mm thk wall care putty complete
M & L for preparation & complete removal of existing treatment on internal surfaces of walls, and applying Two coat of distemper oil emulsion over a coat of alkali resistant primer and 1.50mm thick wall care putty complete all specified and directed Note Application of paint,primer and wall care putty shall be as per manufacturers instruction
M&L for complete removal of existing suracfe finishes of external wall and apply Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over over 1.50mm thk wall care putty complete
M & L for complete removal of existing treatment & preparation of old surfaces and applying Two coat of white wash on ceiling all as specied and directed.
M & L for complete removal of existing treatment & preparation of old surfaces and applying Two coat of white wash on Wall all as specied and directed by Engineer in charge
M&L for Preparation of old wooden surface of any description over 10cm in girth/width and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of new wooden surface of any description over 10cm in girth/width and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparing old treated steel surfaces of any description exc 10 cm width or girth and applying two coat of anti corrosive paint over a coat of red oxide primer complete all as specified
M&L for preparing old treated surface of steel of any description n.exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L for Antitermite post costruction treatment along the external wall below concrete or masonry using chemical emulsion @2.25/linear meter including pluging holes etc
M&L for Antitermite post costruction treatment under existing floors using emulsion one litre /hole300mm apart including drilling along internal wall below including pluging holes 12 mm dia holes with CM1:2 to match the existing floors
M&L for Antitermite post costruction treatment at all points of contact of wood work by chemical emulsion @0.5litre/ hole by drilling 6mm dia holes at a down ward angle of 45 degree at 150mm centre to centre and sealing the same.
M&L for Treating crumple joints with necessary treatment etc complete by racking out joints, clearing of loose particles, providing preformed expendable synthetic filler board and top 15mm primed and sealant throughout the length of joints incl fixing aluminium sheets of 1mm thickness and 150mm length to with brass screws / washers all as speicified.(Make: BASF/Fosroc/IWL/ STP Ltd)
Taking down tar felt (water proofing treatement) on roof slab incl cleaning and removing tar felt material and disposing to a distance of exc 250m not exc 500 m complete all as specified
M&L for cement concrete 25 mm, thick type B-0, 1:2:4 using 12.5 mm graded stone aggregate as padding on roof slab complete all as specified and as directed .
M & L for 10mm thick rendering in CM ( 1 : 3 ) mixed with water proofing compound on fair faces of brick walls or concrete surfaces and finished even & fair complete all as specified. Note : water proofing compound paid separately
M & L The water proofing treatment in seven course and shall be carried out as follows: (i) Apply a coat of oil based bituminous primer @ 200 gram / square metre on the prepared surface. (ii) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area. (iii) Provide and lay 4mm thick APP modified torch applied water proofing membrane weighing not less than 4.00 Kg per square meter reinforced with non woven polyester matt, weighing not less than 160gm/sqm having softening point not less than 1400C, Longitudinal tensile strength not less than 600 N/50 MM, tear strength of 180N(Min), a static puncture resistance of 180, keeping a minimum of 10 cm over laps and 15cm end lap. (iv) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area. (v) Provide and lay 4mm thick APP modified torch applied water proofing membrane weighing not less than 4.00 Kg per square meter reinforced with non woven polyester matt, weighing not less than 160gm/sqm having softening point not less than 1400C, Longitudinal tensile strength not less than 650N/50mm, tear strength of 180N(Min), a static puncture resistance of 180, keeping a minimum of 10 cm over laps and 15cm end lap. (vi)Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area. (vii) Finishing surface with solar reflective bituminous aluminium paint, @ 100 gm/Sqm.
S&F in repair Stainless steel chromium plated bottle traps 32mm dia for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified.
Demolition of cement concrete (reinforced) in ground floor and paving not exceeding 15 cm thick (below or above G.L) all as specified and directed
M&L for RCC(Nominal Mix) in type-A1 1:1.5:3, using 20mm graded stone aggregate as in pre cast slabs supported on walls for cup board and Kitchen slabs, manhole covers,drains.
M&L for mild steel TMT bars 10MM dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed.
M&L Formwork to rough finished surface of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
S&F in repairs viterous China wash down water closet wall mounted, white incl plastic water closet seat, black, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device, fixing bolts, PVC valveless, concealed flush tank with required accesories complete all as specified and directed.
S&F in repair of conceald flushing cistern by replacing existing float valve and discharge valve including minor adjustments and servicing of Make - Cera/perryware/Jaquar etc
Demolition of cement concrete unreinforced in any Position not otherwise specifically provided for.
M&L for water proofing for sunken slabs including all materials as per the stages described below, complete all as specified and as directed. (a)Remove all dust, oil, dirt, laitance and other containments, loose particles from concrete surface . (b) Chamfering the floor wall junctions with cement mortar 1:4 admixed with NitoBond SBr or equivalnt @ 1 litre per 50 Kg bag of cement. (c) Annular space of out let/spout pipes shall be packed and sealed using Conbextra GP2 or equivalent mixed water and filling as per manufacturers specifications. (d) Carrying out ponding for minimum of 48 hours (e) Injection grouting of all leaking spot and honey combs with cementious pressure grouting with 40psi pump using Cebex 100 or equivalent @225 gms mixed to 50 Kg bag of cement incl joints packing using polymer modified mortar. (f) Providing and applying water proof coating using fosroc Nitoproof 600 or equivalent, over dry surfaces to achieve 1.5mm thick with 02 coats with interval period of 6 hours over the surface using spray/ squngee/ roller/ brush. Water proofing coating shall have the elongation of 500-700% (ASTM D412-90), tear resistance of 21Kn/m (ASTMD624-00) and tensile strength of >1.9 N/mm2. Termination to be done on wall extending the coating to min 300mm height above the finished floor level as per vendor recommendation. Laying 200gsm non-woven geo textile membrane over Nitoproof 600 coating with overlap sealed. Make:- FOSROC or equivalent as approved.
M&L for 50mm thick PCC 1:2:4, type B1 Using 20mm graded stone aggregate for sub base of sunken portion complete all as specified
M&L for PCC 1:5:10 type E2 using 40mm stone aggregate as in sunken floor of toilet/bathroom finished fair and even complete all as specified
M&L for 50 mm dia UPVC pipe of pressure rate 10kgf/cm2 as water spout in sunken floor complete all as specified and directed. Make:Prince/Supreme/Finolex
Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high
Index hands (natural size) or arrows (upto 40cm long) as directed
M&L for gap between the pipes / sleeves / bore of any dia and RCC shall be free from dust, laitance, oil and water using compressed air or by mechanical measures. All Pipes to be placed/inserted in the core cut areas shall be aligned properly prior to bore packing. Cleaning / Roughening the inside surface of the bore hole and PVC Pipe outer area. Pipes to be inserted in the core cut areas with effective leak-free shuttering system. The pipe to be inserted, appropriately roughening with hacksaw-blade, applying a coat of Epoxy bonding agent and sprinkle the quartz sand / fine sand and allow to dry for 6 hrs. Filling the gap between PVC pipe and core cut with chemical as per manufacturer instruction including shuttering the gap bottom with backer rod or with suitable material. Apply a coat of waterproof coat and place correct dimension comb cut piece of 60GSM geotextile fleece and place it across pipe and saturate it with waterproof chemical. Place another 60GSM geotextile fleece cut in flower pattern and placing at comb cut fleece and ensure to saturate the geotextile fleece with waterproof chemical.
M&L Pre-painted galvalume aluminum zinc coated A2-150 GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. Note New sheet shall be fixed over existing sheet in curve shape as per site requirement and no taking down need to be carried out
Dismantling timber scantiling 40sqcm and over in section unframed work in any position.
M&L for wrought 1st class hard wood timber Fir/Spruce/Pine wood runners of 70 mm X 45 mm treated with anti-termite solution and fixed on the bottom side to support the flooring with 10 mm thick EPDM cushioning pads by nails through the two wings at 350 mm c/c complete all as specified.
S&F for Kiln Seasoned Teak Wood Surface board finished with 21 mm thick, 50 to 85 mm width and in random length in tongue and groove. The edges of the boards will have a finger lock grove and the bottom side with air pass groove. The Installation: A vapor barrier will be placed on the leveled IPS sub-floor before laying the under frame. The runners having air cell cushioning pads will be placed on the vapor barrier in perfect level at 350 mm c/c in one direction. The surface boards will be screwed to the runners through the tongue only and will lock the screwed tongue by the groove of the adjoining boards. The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion gap of 8 to 10mm will be left open between the wooden flooring and the surrounding tiled area/wall complete all as specified and directed by Engineer-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation.
M&L for Non skid Polyurethene Lacquer polishing of wooden floor including cleaning and preparing the surface by machine sander with floor sander machine including a coat of wood filler with two or more coats complete all as specifiedand directed by Engineer-in-Charge.
S&F in repair Aluminium(Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (Make: Everite/Universal/Dyana)
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified
Demolition of 100mm AC or reinforeced concrete drain pipes, jointed in cement mortar and taking out of wall complete
S&F PVC (SWR) pipes 110 mm dia single socketed in any length , with rubber rings joints fixed to wall with claps including all as specified
S&F PVC (SWR) pipes 75 mm dia single socketed in any length , with rubber rings joints fixed to wall with claps including all as specified
S&F PVC (SWR) bends 110 mm dia with access door
S&F PVC (SWR) bends 75 mm dia with access door
S&F PVC (SWR) 110 mm dia vent cowl
S& F PVC (SWR) 75mm dia vent cowl
S&F PVC Nahani Trap 75mm (SWR) floor trap, plain with grating including jointing with solvent or cement
S&F In repairs for removal of old PVC/cast iron loor trap incl wall crossing pipe and fixed with new outlet 75mm pvc (swr) floor trap with stainless steel grating and new wall crossing and filling with pcc 1:2:4 with water proofing compound including matchng with existed tile and joining with outer pipe line with solvent all as specified and directed.
S & F 110mm dia PVC (SWR) T single junction with access door
S & F 75 mm dia PVC (SWR) T single junction with access door
S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified.
S & F in repairs Soap dish Stainless steel with chromium plated complete all as specified. Make : Prayag Cat No T6403A1 or equivalent in approved list
S&F CP in repair Tubular towel rail, brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified Prayag Cat No BA-30 or equivalent in approved list .
S&F in repair for SS towel ring of standard quality complete all as specified and directed. Prayag Cat No BA-31 or equivalent in approved list
Taking down rainwater pipe, eaves gutter and AC vent pipe of any size including AC gutters, walls etc incl all fittings.
S & F 300 mm width rectangular UPVC SWR ready made eaves gutter of pressure rating 6 Kg/cm2 of approved make including necessary fitting like bend WC/MS Clips etc complete all as specified.
S & F 150MM dia of PVC (SWR) pipe single socketed in any length with rubber joints including necessary fitting like bend WC/MS clips etc fixed on walls complete all as specified
Dismantling Single layer Mangalore pattern or similar tiles in roofing
S&F in repair Vitreous China urinals, half stall urinal type complete including prviding and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including spreader of PTMT any colour for fixing with 15mm dia pipe and including 32mm dia waste pipe coupling all as specified and directed.
All as above ser No 111 but refixing old only
S&F in repair vitreous Chinaware partition for urinal of size 310x700 mm all as specified.
M&L for mirror polishing on marble/granite/kota stone stone work where ever required to give high gloss finish complete all as specifed and directed.
Taking down old GI/CPVC pipe of size 40 mm complete all as specified and as directed
Taking down old GI/CPVC pipe of size 25 mm complete all as specified and as directed
Taking down old GI/CPVC pipe of size 20 mm complete all as specified and as directed
Supply and fix on wall/concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 40 mm dia complete all as specified and as directed
All as per item No 118 here-in-before but of size 25 mm dia complete all as specified and as directed
All as per item No 118 here-in-before but of size 20 mm dia complete all as specified and as directed
Taking down old bib cock long nose, pillar tap, angle valve, health faucet, angle cock etc complete all as specified and as directed
S&F 15mm bore bib cock Chromium Plated fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F Chromium plated fancy type 15mm stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions fixed as directed.
S&F health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metrre long flexible tube and ABS wall hook inlcuding making connections and fixed in position complete in all respect as specified.
S&F in 15mm Pillar cock Chromium Plated fancy type cast copper alloy with crutch or butterfl;y handle, screwed down, screwed for iron pipe of for brass ferrule complete all as specified and as directed.
S&F Chromium plated fancy type concealed type 15mm stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions fixed as directed.
Taking down old PVC connection complete all as specified and as directed
S&F PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and as directed
Dismantling old PVC water tanks of capacity exc 1000 ltr and n exc 2000 litres from its position complete all as specified and as directed.
S&F of rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position of capacity 1000 litres complete all as specified and as directed.
S&F of rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position of capacity 2000 litres complete all as specified and as directed.
Taking down old CPVC ball valve of size 40mm/ 20mm/ 25mm complete all as specified and directed.
S&F CPVC Ball Valve of size 25 mm dia suitable for CPVC pipe incl necessary fittings complete all as specified and as directed
S&F Float valve synthetic (PVC) of size 25 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 455gms) high pressure with polythene ball of size 6’’ dia and flynut complete all as specified and as directed
Taking down carefully existing copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed.
Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified
Materal and Labour for light point wiring with 1.5 Sqmm PVC insulated sheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non metalic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including chases cutting incl suitable size/ cap of sunken box for modular switch and socket and modular white cover plate, flush metal box etc inxl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
All as per Item No.138 here-in-before but for one fan/exhaust fan point controlled by one switch complete all as specified and as directed.
All as per Item No.138 here-in-before but for one bell point controlled by one push button on independent board complete all as specified and as directed .
All as per item No. 138 but for one 3 pin 5 Amp socket outlet point controlled by one switch on Independent boardcomplete all as specified and as directed .
All as per item No. 138 but for one 3 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and as directed .
All as per item No. 138 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cablecomplete all as specified and as directed .
All as per item No. 138 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cablecomplete all as specified and as directed .
S&F Modular Bell push 6A 1 module complete all as specified and directed. Make Legrand Cat Part No. 5734 13 or equivalent to Schneider/ L&T
M&L Switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make Legrand Cat Part No. 5734 00 or equivalent to Schneider/ L&T
M&L Switch modular type 16 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make : Legrand Cat Part No. 5734 10 or equivalent to Schneider/ L&T
S&F Socket outlet modular type 6A - 2 in 1,without shutter, 2 module, duly ISI marked, complete all as specified and directed. Make Legrand Cat Part No. 5734 24 or equivalent to Schneider/ L&T
S&F Socket outlet modular type 16A, 3 pin combined, 2 module, duly ISI marked, complete all as specified and directed. Make Legrand Cat Part No. 5734 71 or equivalent to Schneider/ L&T
S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed.
S&F Electric Bell, AC, 230 volts, single pole complete all as specifeied and directed. Make : Legrand Cat Part No. 5734 43 or equivalent to Schneider/ L&T
S&F rotary Stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 2 module, 120W, white in colour, duly ISI marked complete all as specified and directed. Make : Legrand Cat Part No. 5734 16 or equivalent to Schneider/ L&T
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10cm girth on Stone concrete block or slab walls complete all as specified and directed.
Taking down high bay light fittings of any description at height by providing necessary arrangements of scaffolding and keeping in safe custody complete all as specified and as directed.
Refixing of high bay lights of any description and making connection complete all as specified and directed.
S&F in replacement circular highbay LED light 100 Watt, 240 volt, min lmumens 110 Lm/w, IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make : Philips Cat ref. BY515P LED100S 5700 NB S1 PSU GR or equivalent to Havells/ Crompton
Supply and fixing in replacement LED lights fitting 1x 20 W, 220V, AC decorative box type,120 lumen/watt with driver, holder and high quality materials and design exttruded aluminium housing enhances safety, high quality PC diffuser reliable and robust housing structure including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and as directed. Make : Philips Cat ref. BN308C LED20S-6500 L120 PSU WH or equivalent to Havells/ Crompton
Supply and fixing in replacement LED lights fitting 1x 36 W, 220V, AC decorative box type,120 lumen/watt with driver, holder and high quality materials and design exttruded aluminium housing enhances safety, IP-20 rating, driver efficiency 90%,high quality PC diffuser reliable and robust housing structure including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and as directed. Make : Philips Cat ref. RC360B LED36S-6500 L120W30 PSU OD or equivalent to Havells/ Crompton
Supply and fixing in replacement LED lights fitting suspended type 1x 36 W, 220V, AC decorative box type,120 lumen/watt with driver, holder and high quality materials and design extruded aluminium housing enhances safety, IP-20 rating, driver efficiency 90%,high quality PC diffuser reliable and robust housing structure including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and as directed. Make : Philips Cat ref. SP1 70P LED25S-6500 PSU W5L113 OD WH or equivalent to Havells/ Crompton
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make : Philips Cat ref. SP1 70P LED25S-6500 PSU W5L113 OD WH or equivalent to Havells/ Crompton
S&F in replacement dimmable cob light light 6 watt, min 100 lumen/watt, 50 hz,230 volts with all accessories and connection to the electric circuit complete all as specified and as directed. Make : Philips Cat ref. RS262B LED6S/865 PSU MB WH or equivalent to Havells/ Crompton
S&F in replacement dimmable cob light light 12 watt, min 110 lumen/watt, 50 hz,230 volts with all accessories and connection to the electric circuit complete all as specified and as directed. Make : Philips Cat ref. RS263B LED15S/865 PSU MB WH or equivalent to Havells/ Crompton
Supply and fixing recessed LED light 15/18 watt round AC 220 volts type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make : Philips Cat ref. DN496 LED15S-6500 PSU WH or equivalent to Havells/ Crompton
S&F of LED luminaire 600mm x 600mm, 36W, 240 Volts, single phase recessed type with high efficiency PMMA diffuser soft glare light complete with driver suitable for roof ceiling including connecting up with driver three core flexible copper conductor of size 23/00.0076 all as specified and directed all as specified and as directed. Make : Philips Cat ref. RC370B LED36S-6500 G6 L60W60 PSU OD V3 or equivalent to Havells/ Crompton
Supply and fixing of recessed and surface LED 1 ft x 1 ft panel celing light with high performance commersial grade solution suitable for school 18 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make : Philips Cat ref. RC360B LED25S or equivalent to Havells/ Crompton
Supply and fixing of recessed and surface LED 1 ft x 4 ft panel celing light with high performance commersial grade solution suitable for school 36 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make : Philips Cat ref. RC380B LED36S-6500 G5 L12W3 PSU OD or equivalent to Havells/ Crompton
S&F of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make : Philips Cat ref. BRP331 LED36 CW R5N PC PSU S1 V1 or equivalent to Havells/ Crompton
S&F of all in one integrated Solar Hybrid LED street light fitting 25-30 Watt 230 V AC with luminous efficacy greater than 150 Lm/Watt outdoor type with in built lithium battery of min 30 AH capacity, Monocrystalline solar panel of min 60 Wp and MPPT charge controller with along with sensors in high pressure die cast aluminium housing with IP 65/66 protection incl mounting arrangement on building complete all as specified and as directed.
Taking down fan, sealing cable end, dismantling blades, removing fan, painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and refixing ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
Taking down exhaust fan, sealing cable end, dismantling blades, removing fan, painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and refixing exhaust fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
Taking down wall mounted fan, sealing cable end, dismantling blades and keeping in safe custody and refixing wall mounted fan after cleaning and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
S&F in replacement of ceiling fans, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose including taking down old ceiling fans complete all as specified. Note : Old Ceiling fans to be deposite at AGE E/M (NW) store yard. Make : Orient Cat ref. I-Falcon DEco BLDC or equivalent of Havels Enticer Prime BLDC Cat ref. FHCPE5SPWT48 / Usha Cat ref. Aeroedge Plus
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm including taking down old exhaust fans complete all as specified. Note : Old exhaust fans to be deposite at AGE E/M (NW) store yard. Make : Havells Cat Part No. Ventil Air-DX white or Crompton Cat Part No EXHD300-4-1 or equivalent to Orient
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep heavy duty with, blades, and frame and louvers including taking down old exhaust fans complete all as specified. Note : Old exhaust fans to be deposite at AGE E/M (NW) store yard. Make : Havells Cat Part No. Ventil Air-DB or equivalent to Crompton / Orient
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep heavy duty with, blades, and frame and louvers including taking down old exhaust fans complete all as specified. Note : Old exhaust fans to be deposite at AGE E/M (NW) store yard. Make : Havells Cat Part No. Turbo Force Neo 1P or equivalent to Crompton / Orient
Supply and fixing in replacement of metallic body wall fans, heavy duty, 230 volts single phase oscillating 450 mm sweep Five star rated with brushless direct current motor (BLDC) suitable for wall mounting including taking down old wall fans complete all as specified. Note : Old fans to be deposite at AGE E/M (NW) store yard. Make : Havells Cat Part No. Turbo Force Wall or equivalent to Crompton / Orient
S&F in replacement of Factory made three phase and neutral sheet steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming MCCBs and outgoing MCB the second for protection of MCBs fitted with colour cu bus bar of capacity 250 Amps, neutral link, earth bar and din rail suitable for use on 415V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified. Make Legrand Cat Part No. 5077 20 or equivalent to L&T/ Schneider
S&F of Factory made three phase and neutral sheet steel made out of CRCA 1.2 mm thick, powder coated double door distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 415V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified. Make Legrand Cat Part No. 5077 40 or equivalent to L&T/ Schneider
S&F of Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified. Make Legrand Cat Part No. 5076 00 or equivalent to L&T/ Schneider
S&F of Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified.
S&F MCCB 3 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 36 KA complete all as specified and as directed.
S&F MCCB 3 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 36 KA complete all as specified and as directed.
S&F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and as directed.
S&F MCB TP, 25Amps-63.Amps, 415 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning all as specified.
S&F MCB TPN/ FP, 40Amps-100Amps, 415 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning all as specified.
S&F MCB SPN, 40A - 63Amps, 240 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning all as specified.
S&F MCB SP, 6A-32 Amps, 240 volts, "C" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning all as specified.
S&F of single pole and neutral 240 Volts, enclosure with three pin and earth plug and socket complete with one DP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified.
M&L for Sub main wiring with two single core 2x1.5 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 1.5 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed. Note Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length
M&L for Sub main wiring with two single core 2x2.5 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 2.5 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed Note Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length
M&L for Sub main wiring with two single core 2x4 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 4.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed. Note Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length.
M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed Note Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length.
M&L for Sub main wiring with four single core 4x10 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 10.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed Note Four runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length
M&L for Sub main wiring with four single core 4x16 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 16.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed Note Four runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length.
M & L in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10mm c/c ,20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S&F in replacement of XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross sectuional area 16 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
S&F in replacement of XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross sectuional area 25 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
S&F in replacement of XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross sectuional area 70 sq.mm 3.5 core including taking down old unserviceable cable complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified.
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified.
Supply, Fill, Spread and ramming / consolidation in layers, dry river sand in trenches for cushioning and covering of UG cables complete all as specified.
Removal of excavated soil to a distance not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
technical_843690.pdf
techsummary_843690.pdf
finance_843690.pdf
BOQ Comparative Chart
xlsx
finsummary_843690.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
tenderdocuments.pdf
Tender Documents • 2.07 MB
BOQ_843690.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid