| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹37.8 L+₹1.8 L (5.01%)Rejected-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹39.4 L+₹3.4 L (9.30%)Rejected-Finance | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹39.4 L+₹3.4 L (9.49%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹39.9 L+₹3.9 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
12 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-14/2021-22 PROVN OF CERTAIN SANCTION WORKS IN SECTOR A UNDER AGE B/R-II OF GE (NORTH) AMBALA CANTT
2021_MES_431877_1
GE(N)Amb-14/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹64,000
Yes
17 Sept 2021
12 Jun 2021
14 Jul 2021
12 Jun 2021
12 Jul 2021
28 Jun 2021
12 Jun 2021 - 28 Jun 2021
60 days
Amount
Schedule 'A' Part-I (B/R itmes) Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material to a distance exc 250m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:5:10 Type E2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L sand filling under floor or in foundation including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Demolition cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as direced by the Engineer-in-charge.
M & L damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for rough finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC 1:2:4 type B1 using 20mm graded aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L RCC in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs under- reamed piles and mass concrete type B1 1:2:4, (using 20mm graded crushed stone aggregate) complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 6 to 8 mm dia cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge exc 63mm and n exc 100mm , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1 :4 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:4 using water proofing compound @ 2% by weight of cement or as per manufacurer's instructions and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. ( water proofing compound shall be measured and paid for separately) .
M&L for rendring 15mm thick in cement plaster 1:6 on any faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in charge.
M&L rendering 5 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L 10mm thick cement plaster in CM 1:4 on roof slab mixed with water proofing compound @ 2% by weight of cement or as per manufacurer's instructions, surface finished fair and even complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid separately).
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of newly plastered or un-plastered surfaces on walls ,chajjas , roof projection , cornices etc. and applying two coats of cement based paint (white or tinted) over a coat of alkali resistant primer , complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of wall and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area n. exc 1.5 Sqm each and removal from site complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
S & F for steel windows or ventilators, fixed type, with glazing bars complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by engineer in charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately. complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 or Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
S & F Flush shutters 32 mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 4.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F Galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.00mm thick frosted and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing mild steel butt hinges 100 mm long medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 300 mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
Supply only mild steel butt hinges 50 mm long medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel door shutter two leaves with frame of 20 gauge MS sheet (all around) and leaves of 21 gauge MS Sheet ( all as per Godraj Pettern) with three way locking arrangement with brass lock with CP handle with duplicate key including two coats of spray painting over a coat or red oxide primer complete fixed in existing cupboard fixed with necessary nuts bolts including embedded in PCC 1:2:4 (area of opening shall be measured) complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and as directed by the Engineer-in-Charge.
M & L brushing neat cement slurry with 3.0 kg cement per sqm, complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/skirtings/dados of size 350x250x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in sub base of floor and finished even and fair to receive tiles etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L Machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L for providing Precast cement concrete 1:2:4 type B1 using 20mm graded aggregate as in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), Kerb Stone string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and set in CM 1:4 complete with joints to match complete all as specified and as directed by the Engineer-in-Charge.
Dismantling Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by the Engineer-in-Charge.
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the Engineer-in-Charge.
M & L cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed, set jointed and pointed in neat cement slurry with grey cement and no pigments, grouted flush in cement mortar 1:4 in roof over and including 15mm thick screed bed in CM 1:4, complete all as specified and as directed by the Engineer-in-Charge
M & L carring out roof treatment consisting of following:- 1. Cleaning of concrete roof surface by roughening, picking, sweeping, cleaning and washing down with water to remove dust etc, 2. Brushing neat cement slurry with 3.0 kg of cement per sq. metre. 3. Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufacturer of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
S & F 500 litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge Note:- Tank shall be in white colour.
S & F 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minium weight-200 grm) complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, including cast iron 'S' trap 100 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S&F 32 mm dia PVC waste pipe of standard length for wash hand basin / Kitchen sink etc complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing fancy type pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing as in repair fancy type pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated angular stop valves fancy type with long shank and cup , screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm as in repair bore cast copper alloy chromium plated angular stop valves fancy type with long shank and cup, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, concealed r type with long shank, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm as in repair bore cast copper alloy chromium plated stop valves, angular type with long shank, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
S&F brass as in repair chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
S & F of 20mm bore stop valve, cast copper alloy chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair of 20mm bore stop valve, cast copper alloy chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge
S & F bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge .
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified and as directed by the Engineer-in-Charge.
S & F aluminium powder coated curtain rod 25mm dia fixed with and including decorative brackets, two lotto in each length at the end etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) P/S trap including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC(SWR) bends of any radius etc complete all as specified and as directed by the Engineer-in-Charge.
M & L PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in surface channel and drain complete all as specified and as directed by the Engineer-in-Charge.
Extra for forming fair finish drain or channel 30 cm inner girth in cement concrete using extra cement including forms mould mitered/ stopped end etc complete all as specified and as directed by the Engineer-in-Charge.
M&L 150mm bore salt glazed stone ware drain pipe grade 'A' laid in trenches and jointed complete all as specified and as directed by the Engineer-in-Charge.
M & L concrete bed in PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate to drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 150 mm dia (internal) pipes complete all as specified and as directed by the Engineer-in-Charge. (Pipes shall be measured & paid separately).
M & L cutting into existing manholes for connecting new drain, making good to pipe 150 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
S & F of fixing GI OREO Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, complete for all heights as per specifications, and as directed by Engineer-in-charge. GI Metal Ceiling laying perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Dismantling of plain or corrugated steel sheet of any thickness incl Nainital or similar pattern coverings, complete all as specified and as directed by the Engineer-in-Charge.
S& F for 6mm thick asbestos cement, corrugated or semi-corrugated shets in roofs, walls, etc fixed with 'J' or 'L' type hooks, bolts, nuts and washers complete all as specified and as directed by the Engineer-in-Charge.
S&F kitchen plate rack of stainless steel sheet 1mm thickness of size 600mm x 750mm x250mm having for shelves and weight not less than 8.00 Kg each complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
M & L for taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, including cast iron 'S' trap 100 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper over prepared surfaces of wall, pillar, cornices complete all as specified and directed .
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of ceiling by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white lime wash over prepared surfaces of ceiling complete all as specified and directed .
M&L preparation of old decorated wooden Surfaces, and applying one coat of synthetic enamel (ordinary tint) on wooden surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and as directed by Engineer-in charge .
M&L preparation old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description area exc 1 sqm and not exc 2 sqm each and refixing in the same opening after easing of old shutter including welding wherever required and replacing of old hinges complete all as specified and as directed by the Engineer-in-Charge. ( new hinge shall be measured and paid for separately)
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white lime wash over prepared surfaces of wall, pillar, cornices complete all as specified and directed .
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in padding , filling of depression in roof slab to maintain proper slope roof complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases, to brick wall pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long as in reapir complete all as specified and as direced by the Engineer-in-charge.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet but excluding tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 25 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 143 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 143 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 25 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F electronic Fan regulator modular, step type,120 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,with one PVC block of size 75mm x75mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, pin type 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix as in repair MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB double pole, 240 volt, 6 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair RCBO 40 Amps, 2 Pole, 4 module 30 mA (HI immunity) sensitivity 230 volts 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps, 2 Pole, 4 module 30 mA (HI immunity) sensitivity 230 volts 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over and low voltage release 230 volts, single phase in one module, suitable for (1 Ph+n) AC, adjustable for 170volts to 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix as in repair over and low voltage release 230 volts, single phase in one module, suitable for (1 Ph+n) AC, adjustable for 170volts to 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing as in repair SPN distribution board 8 way, double door, IP 43, as per IS 8623 including 100amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimble, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral (VTPN) with TPN MCCB 100 Amp, 16 KA for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed after removing old Unserviceable MCB DB surface complete all as specified and as directed by the Engineer-in-Charge.
S & laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fixing indoor decorative LED tube light fitting Batten type 1x18/20 W with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 W LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED batten fitting 10-12 watt, 2 feet, 6500K aluminium housing and integrated electronic driver including tube rod cool/warm type industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair LED batten fitting 10-12 watt, 2 feet, 6500K aluminium housing and integrated electronic driver including tube rod cool/warm type industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED tube light fitting 1x18/20 Watt, box type made from extruded aluminum high lumen out put 6500 K, AC 220-240 Volts, 50 Hz including tube rod (lamp type LED tube light fitting 1x18/20 Watt) and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and as directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sqm nominal cross section area cable with PVC insulated aluminium conductor multi stranded served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 1.60 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed by the Engr-in-charge.
S&F as in repair LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 1.60 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed by the Engr-in-charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 10 sqmm cross sectional area, 2 core with multi stranded aluminium conductor, 1100 volts grade, complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables. and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, Filling in excavated soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L dry sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by the Engineer-in-Charge. Note:- for measurement, punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by the Engineer-in-Charge.
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wire earth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
Supply & Fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C'series complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan by disconnecting electric connection, sealing cable end, dismantling blades, washing the complete parts with surf to remove loose dirt, dust etc and applying one coat of painting on ceiling fans with synthetic enamel paint by spraying including filling cavaties with filler after cleaning all dust etc.and reassembling the same complete all as specified and as directed by the Engineer-in-Charge.
Fixing only as in repair tube light fitting, recess mounted LED fitting and connecting up including provision of flexible cable cable 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED batten light fitting 10/12 watt 220 volt AC decorative, 2 feet, 6500K, aluminium housing with integrated electronice driver including tube rod cool/warm white industrial model complete connecting with three core copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair recess mounted indoor decoraative, vertically/horizontally mounting, top opening, LED light fitting 2'x2' box type with a unique drop down opal diffuser, leading to uniform lighting experience illuminating high efficient aluminium housing body in CRCA body suitable for LED, high efficient, AC 220-240 volts, 50 Hz and including 36-40 watt LED luminaries (Warm/Cool as per site requirement) environment friendly , aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Durga Enterprises
Swami Enterprises
Ashwani Kumar
Karishan Kumar goel
Sawhney Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .