Amount
OD4148/2022-2023:S & F of compartmentalized cubical panel board duly powder coated made out of 16 SWG MS sheet with Al. bus bar i/c interconnection copper wiring arrangement for mounting for switchgears, change over switches ,MCCB i/c making the foundation brick work /angle iron frame on floor/wall with proper locking arrangement etc complete as required at site. upto depth 30 cm
OD4149/2022-2023:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of 2×10 sqmm as required.
OD4150/2022-2023:P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd.(a) 3 X 4 sq.mm.
OD4151/2022-2023:Supplying and fixing following sizes of steel flexible safety rope for holding submersible pump set i/c clips etc complete as reqd.(a) 6 mm dia .
OD4152/2022-2023:S&F MS clamp made up of flat iron of size 50mmx 6 mm with 4 nut bolt for holding the G.I.Pipe 32 mm dia pipe etc as reqd.
OD4153/2022-2023:Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd.
OD4154/2022-2023:Supplying, lowering,testing and commissioning of vertical type, multistage, totally enclosed waterfilled deep well submersible pumping set complete i/c connection etc. as reqd. (a) Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head.
OD4155/2022-2023:S&F following sizes of GI Socket as reqd. (a) 32 mm dia
OD4156/2022-2023:S&F following sizes of GI Elbow as reqd.(a) 32 mm dia
OD4157/2022-2023:Supplying, lowering and fixing following size of G.I. Pipe (M- Class) i/c cutting threading on both sides etc ISI marked etc as reqd.(a) 32 mm dia (Nominal Bore)
OD4158/2022-2023:Supply, Installation, testing and commissioning of cubical type control panel board for single Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd.(b) 1.5 HP Submersible P/set.
OD4159/2022-2023:SITC of single phase monoblock pumpset complete with all accessories workable on 240/415V, 50Hz AC supply (a) 1 HP (0.75 kW) single phase pump set head from 12-30 mtr suction and delivery 25x25mm.
OD4160/2022-2023:P/F ABC(Alluminium phosphate) Power type fire extinguisher 6 Kg capacity complete in all respect with ISI mark i/c fixing arrangement etc complete as reqd.
OD4161/2022-2023:P/F 4.5 kg CO2 type fire extinguisher squeeze grip type,trolly wheel as well mounting type complete in all respect with ISI mark i/c fixing arrangement etc complete as reqd
OD4162/2022-2023:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: (a) Total system wattage 20 watt +/- 5% (b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
OD4163/2022-2023:P&F Hot press sheet moulded compound (SMC) fire retardent (lemp,resistance up to 200 C ). IP 55 weather proof pole box of inner dimension 200×160×98mm(NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp Double isolator (MCB/Isolator excluded ) with neutral link duly shorting on DIN Channel with 2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
OD4164/2022-2023:Supply of 1200 mm sweep 50 Watt,Energy Saver ISI marked BEE 5 star rating AC ceiling fan suitable for 230 Volts, 50Hz AC supply without regulator with blades, downroad etc.complete as required.
OD4165/2022-2023:Supply of light Emitting diode (LED) lamp 15 watt cool day light type suitable for working on 220V, 50 HZ A.C Supply as reqd.
OD4166/2022-2023:SITC of 72W LED Street Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage =72 watt +/- 5% (d) Luminaire Efficacy>=100 Lm/w (e) Power Factor>=0.95 (f) Protection Class- IP-66.
1.15.3:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
1.5:Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.6:Wiring for light / power plug with 4x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit along with 2 Nos 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.45:Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.2:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
120.1442:Supply of Brass batten/ angle holder
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.12:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
14.16.1:Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .