| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | ₹4.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹4.2 LRejected-AOC | ₹4.2 L | L2 | Rejected-AOC Second Lowest Bidder |
Tender Value
₹4.0 L
EMD Value
₹9,954
Closing Date
2 Mar 2026, 2:00 pmClosed
Assistant Executive Engineer
PWD Electrical Sub Division Ernakulam
Electrical AC Work
2026_PWD_839942_1
ESDE(ET)-182/AEE/2025-26
Open Tender
Electrical Works
365 days
Ernakulam
Please refer Tender documents.
10 documents required · 10 mandatory
₹880
₹9,954
23 May 2026
24 Feb 2026
4 Mar 2026
24 Feb 2026
2 Mar 2026
24 Feb 2026
MAINTENANCE
OD82791/2024-2025:Charges for troubleshooting the complaints of split/ ductable air conditioners, attending the repairs etc. and making the unit in good working condition.
OD82794/2024-2025:Servicing of 1.5 / 2 TR split AC unit- Cleaning of indoor unit & cleaning of outdoor unit with pressure washer, checking all mechanical and electrical parts, attending petty repairs etc. and making the unit in good working condition.
OD82792/2024-2025:Dismantling the existing 1.5 / 2 TR split AC indoor & out door unit, refitting the same after water servicing both indoor & outdoor units using pressure washer, cleaning filters, checking all mechanical and electrical parts, attending petty repairs etc. and making the unit in good working condition.
OD82793/2024-2025:Servicing of 5.5/8.5/11.5 TR Ductable & Cassette type AC unit, cleaning the indoor unit filters, water servicing the outdoor unit with pressure washer, cleaning filters, checking all mechanical and electrical parts, attending petty repairs etc. and making the unit in good working condition.
OD82797/2024-2025:Supply and providing following sizes of soft drawn copper refrigerant pipe with all accessories such as elbow, support clamp etc. for interconnecting indoor unit and outdoor unit including thermal insulation with 9 mm nitrile rubber tubings, bracing, leak testing etc. 3/8"(9.52mm) and 5/8"(15.8mm) 22 gauge.
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD82798/2024-2025:Supplying and fixing the following sizes of PVC pipe with necessary fittings, hangers/supports etc. and insulated with 13mm thick nitrile rubber sleeves. Size: 25 mm dia
OD82799/2024-2025:Supply of 48mm white colour, PVC Self Adhesive Tape and wrapping in the existing Air Conditioner Copper Pipe and make it weather proof.
OD82800/2024-2025:Supply and providing 9 mm nitrile rubber tubings in existing copper refrigerant pipe by replacing the existing damaged nitrile rubber insulation.
OD82801/2024-2025:Relocating existing hard drawn copper refrigerant pipe with all accessories such as elbow, support clamp etc. for interconnecting indoor unit and condensing unit including thermal insulation with rubber seal, foam sleeve, bracing, leak testing etc.( 5/8" & 3/8'') diameter 22 gauge.
OD82802/2024-2025:Supply of universal/ specific make Remote control compatible for all type of Air conditioners.
OD82803/2024-2025:Supply and renewal of outdoor fan motor of 1.5 TR AC in place of damaged one and giving connections etc. as required
OD82804/2024-2025:Supply and renewal of outdoor fan motor of 2 TR AC in place of damaged one and giving connections etc. as required
OD82805/2024-2025:Supply and fixing fan blade in the existing 1.5/2TR Split AC outdoor unit and making the unit in working condition.
OD82806/2024-2025:Supply and renewing Running Capacitor 45 MFD for AC unit - 1.5 TR in place of the existing faulty ones and giving connections etc as required
OD82807/2024-2025:Supply and renewing Running Capacitor 50 MFD for AC unit - 2 TR in place of the existing faulty ones and giving connections etc as required.
OD82808/2024-2025:Charges for dismantling and relocating the outdoor unit of 1TR/1.5TR/2TR Split AC unit and servicing of indoor unit, outdoor unit, filling required quantity of gas and making the AC in good working condition.
OD82809/2024-2025:Charges for supply and filling R-32 / R-410A gas after evacuating air conditioning system. (including refrigerant lines, coils, etc)
OD82810/2024-2025:Supply, conveyance, installation, testing and commissioning of Filter drier DML084 M/24 of Danfoss make.
OD82811/2024-2025:Supply and renewal of condenser coil of 1.5 / 2 TR split AC in place of damaged one and giving connections etc. as required
OD82812/2024-2025:Supply and renewal of rotary compressor ( Suction tube 16 mm dia , discharge tube 9.7 mm dia , discharge pressure maximum < 2.06 Mpa , suction pressure maximum 0.1 - 0.69 Mpa ,230 V , 50 Hz ) of 2 TR AC in place of damaged one and giving connections etc. as required
OD82813/2024-2025:Supply and renewal of rotary compressor ( Suction tube 16 mm dia , discharge tube 9.7 mm dia , discharge pressure maximum < 2.06 Mpa , suction pressure maximum 0.1 - 0.69 Mpa ,230 V , 50 Hz ) of 1.5 TR AC in place of damaged one and giving connections etc. as required
OD82814/2024-2025:Supply and renewal of outdoor unit PCB of 2TR split A.C and make the unit in good working condition.
OD182405/2025-2026:Charges for repairing the indoor/ outdoor unit PCB of 5.5/8.5 TR ductable AC unit and make the unit in good working condition.
OD182406/2025-2026:Charges for repairing the indoor/ outdoor unit PCB of 1.5/2TR split AC unit and make the unit in good working condition.
OD82815/2024-2025:Supply and renewal of outdoor unit PCB of 1.5TR split A.C and make the unit in good working condition.
OD82816/2024-2025:Supply and renewal of indoor PCB suitable for 1.5 TR split AC unit in place of damaged one
OD82817/2024-2025:Supply and renewal of indoor unit PCB of 2TR ductable AC and make the unit in good working condition.
OD82818/2024-2025:Supply and renewal of outdoor unit PCB of 8.5TR ductable A.C and make the unit in good working condition.
OD82819/2024-2025:Supply and renewal of indoor unit PCB of 8.5TR ductable A.C and make the unit in good working condition.
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
OD182432/2025-2026:Engaging helper for one day for cleaning the filters of Air Handling units.
OD182320/2025-2026:Supply, conveyance, installation, testing and commissioning of 8.5TR capacity ductable split air conditioner condensing unit with scroll compressor, Copper condenser coil etc. Bluestar make Model-DSA 1021 R1O
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1415670.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tendernotice_2.pdf
PDF • 0.05 MB
Tendernotice_3.pdf
PDF • 0.12 MB
Tendernotice_4.pdf
PDF • 0.19 MB
Tendernotice_5.pdf
PDF • 0.38 MB
Tendernotice_6.pdf
PDF • 0.04 MB
Tendernotice_7.pdf
PDF • 0.03 MB
viewsbd.pdf
Tender Documents • 1.63 MB
viewnit.pdf
Tender Documents • 0.02 MB
BOQ_1415670.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid