Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-Finance AT UPPER BOOTY NEAR KRISHNA NURSING HOME P S SADAR RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | ₹15.3 L | L1 | Accepted-Finance L1 |
| 2 | L2₹15.5 LRejected-Finance AMETHIA NAGAR NAMKUM RANCHI | RANCHI | JHARKHAND | 829205 | ₹15.5 L | L2 | Rejected-Finance L2 |
| 3 | L3₹15.6 LRejected-Finance FLAT NO 2B SWARANA PALACE GAMHARIYA SERAIKELA KHARSAWAN 832108 JHARKHAND | GAMHARIYA | SERAIKELA KHARSAWAN | JHARKHAND | 832108 | ₹15.6 L | L3 | Rejected-Finance L3 |
Tender Value
₹15.3 L
EMD Value
₹31,000
Closing Date
20 May 2026, 3:00 pmClosed
General Manager
Transmission Zone-VIII, Chaibasa, Tata By-Pass Road, Sikursai, Chaibasa, District-West Singhbhum, Pin- 833201, Jharkhand
AMC work of 132/33 kV GSS, Chakradharpur for the period from 01.06.2026 to 31.03.2027 i.e. 304 days
2026_JSEB_113650_1
89/PR/JUSNL/2026-27
Open Tender
Electrical Works
Chakradharpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Yes
₹31,000
Yes
27 May 2026
6 May 2026
21 May 2026
6 May 2026
20 May 2026
6 May 2026
Checking and Observation (1. Clamp, connectors & jumpers. 2. Air & Gas Pressure. 3. Batteries & Battery System. 4. Control & Relay Panels. 5. Transformers Oil & Winding temperature, Fans Oil Level, Silica Gel, Oil leakage and Equipment noise.
Preventive/ Routine Maintenance of Grid Sub-station as per schedule provided by Engineer Incharge.
132 kV Bay-Nut bolt tightening, adjustment of contacts (Male/female) cleaning, greasing, mobilization & jelly putting in clamp & connectors, Earthing flat, jumpers and other equipments related with Insulators, Isolators, CT, PT, CB, LA, dropping and panel of a Bay etc. halfyearly. (as per direction of E/I)
33 kV Bay-Nut bolt tightening, adjustment of contacts (Male/female) cleaning, greasing, mobilization & jelly putting in clamp & connectors, Earthing flat, jumpers and other equipments related with Insulators, Isolators, CT, PT, CB, LA, dropping and panel of a Bay Quarterly.
33 kV Half Main Bus Nut bolt tightening, adjustment, cleaning, greasing, mobilization & jelly putting in clamp & Connectors, Earthing flat, jumpers and other equipments related with Insulators, Isolator, PT quarterly.
33 kV Transfer Bus- Nut bolt tightening, adjustment, cleaning, greasing, mobilization & jelly putting in clamp & connectors, Earthing flat jumpers and other equipments related with Insulators, Isolators, PT halfyearly.
132 kV Half Main Bus- Nut bolt tightening, adjustment, cleaning, greasing, mobilization & jelly putting in clamp & Connectors, Earthing flat, jumpers and other equipments related with Insulators, Isolator, PT halfyearly.
132 kV Transfer Bus- Nut bolt tightening, adjustment, cleaning, greasing, mobilization & jelly putting in clamp & Connectors, Earthing flat, jumpers and other equipments related with Insulators, Isolator, PT halfyearly.
Transformer- Nut bolt tightening, cleaning in clamps & connectors, Earthing flat, jumpers silica gel filling and other equipments related with transformer body. (132/33 KV) halfyearly.
SST - Nut bolt tightening, adjustment, cleaning, clamp & connectors, Earthing flat, jumpers, silica gel filling and other equipments related with SST body quarterly.
Transformer- IR Value measurement (132/33 KV), including SSTs yearly
Transformer & SSTs BDV measurement quarterly.
Circuit Breaker- IR Value measurement (132/33 KV) yearly.
CT (of a Bay)- IR Value measurement (132/33 KV)yearly.
LA (of a Bay)- IR value measurement (132/33 KV) yearly.
PT/CVT (set)- IR Value measurement (132/33 KV) yearly.
Measurement & Testing of transmission line using fault locator or any other device (132 KV )
Measurement & Testing of CB and relay using CT Injection Kit or any other device (132KV)
Measurement & Testing of any grid equipment using any kit available in JUSNL or Grid (132KV)
Maintenance / Emergency Maintenance of Grid Substation as per schedule and JOB provided by Engineer In-charge.
Replacement of Nut- bolts (132/33 KV)
Replace of jumper (conductor/strip)
Replacement of clamp & connectors/PG/jumper conia
Replacement of female contact
Replacement of female contact base
Replacement of Isolator blade
Replacement of Isolator blade base
Replacement of Insulators
Replacement of CT/PT junction Box including termination & connection
Minor repairing of Transformer- Meggering with opening of bushing connectors, checking of PRV, vent pipe & Buchholz relay, oil top-up etc... Including all or any. (132/33 KV)
Minor repairing of CB- Meggering, Gas filling, checking of MCB, contactors, motors, spring and tripping or closing coils, SF6 gas filling etc... Including all or any
Minor repairing of Isolators- Adjustment of contacts & moving parts etc… (33 /132 KV)
Minor repairing of Panel- Looping & wiring of cables, loose contact rectification, replacement of lugs, ferrules etc…
Fixing and replacement of Earthing copper bond/ flat
Fixing and replacement of Energy meter/ MW meter/ Voltmeter/Ammeter/Relay
Misc. work of Grid Substation as per schedule and JOB provided by Engineer In-charge
Battery System cleaning and measurment /recording of each cell voltage, sp. Gravity etc. monthly.
Cleaning of Panels (including all 33kV Panels, 132 kV Panels, 220 kV Panels, ACDB, DCDB etc..) monthly
Rectification of lighting and auxiliary power supply in Grid premises
Material/Equipment manual shifting & movement in Grid Premises
Measurement of Earth footing resistance of all earth pits halfyearly.
Supply of Hydra/ Crane (upto 8MT capacity) as per requirement at concerned store and GSS site
Complete overhauling with painting of 150MVA , 50MVA Transformer Cooling Fans with supply of all materials if required
Repair and Overhauling of 3ph Sub-mersible pump including materials, lifting & lay down of Sub-mersible pump from Borewell , repair of water supply pipe all complete job & Transporation cost.
Repair of 132kV SF6 Breaker 3PH/1Ph spring charged motor and isolator motor if required
Repair of 33 kV VCB 1Ph spring charge motor if required
Testing of Transformer/ICTs including tan delta test, winding resistance test, turn ration test, magnetic balance test, open ckt and short ckt test, IR & PI etc. ( All test must be performed and report shall be submitted in standard format)
132/33 KV Transformer/ICTs
Break down maintenance if required
supply of Emergency Gang with T&P for work like Conductor snapping of main bus
Mobilization/Demobilization of Labour Gang
Laying of control cable
Filtration of transformer oil (if m/c supplied by firm)( for Power transformer,SST,CT and PT)
Erection, connection, testing and commissioning as per direction of E/I
33 kV Vacuum circuit Breaker
132 KV SF6 CB
132 kV CVT/PT
Dismantling of following equipments with Crane/Derrick at site including handling the material/ equipment carefully at site including labour charges for all incidental and operational items of work ( Excluding cost of transportation charges from store to site)
33 kV Vacuum circuit Breaker
132 KV SF6 CB
132 kV CVT/PT
Transportation of Transformer accessories/fittings, other GSS equipments, transmission line materials inclusive ERS through Truck/Pick-Up (having capacity upto 3MT) including loading, unloading of the materials/equipments in proper packing (before loading) & unpacking (after loading)
Upto First 50kM
50km<distance<500km(Rate per km)
Air Conditioner maintenance
Service charge for indoor and outdoor unit
Gas Filling Charge
Assessment of defects of battery charger at the GSS
Maintenance and replacement of defective parts/equipments of battery charger including battery bank).
Supply of Consumables viz. Markin cloth, Distilled water, grease, Mobil, Nuts & Bolts, cotton waste, Joute, Petrolium Jelly, Kerosine, WD-40 rust remover etc. Required time to time for O&M works of GSS.
Testing of transformer oil by recognized laboratory including supply of sampling bottle (A mandatory test and it shall be performed at least once in the financial year)
Water content PPM
Contingency ( Including sampling bottle, To&Fro Charges including fooding & lodging)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
AMCChakradharpurBOQ.pdf
Tender Documents • 1.15 MB
AMCChakradharpurPPART-II.xls
Additional Documents • 0.07 MB
Download all tender documents and submit your bid