Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹17.1 L+₹3.5 L (26.0%)Rejected-AOC 199 79 SADAR BAZAR LANSDOWNE TAHSIL LANSDOWNE | L2 | Rejected-AOC NOT LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
18 Jan 2022, 6:00 pmClosed
CWE Hills Dehradun
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003 Tele 01352757790
REPAIRAND MAINT OF WATER SUPPLYING AND DISTRIBUTION PIPE LINE OF VARIOUS SIZES CLEANING OF VARIOUS SIZES CLEANING OF WATER STORAGE TANS AND ALLED WORKS UNDER AGE I LANSDOWNE
2021_MES_491260_1
87094/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Lansdowne
Class E Cat a ii
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹30,000
10 Feb 2022
29 Nov 2021
20 Jan 2022
29 Nov 2021
18 Jan 2022
6 Jan 2022
29 Nov 2021 - 7 Dec 2021
Amount
M&L for Cleaning of Semi UG Sump of capacity 16 Lakh Gln after emptying the sump with help of Pump, removing all mud, waste etc complete, scrubbing the entire sump inside with wire brush, washing the entire sump from inside with water and subsequently with bleaching powder solution and painting inside with two coats of lime wash and writing date of cleaning with white paint after making a block of black paint complete all as specfied & directed.
All as per Serial Item No. 1 above but 7.5 lakhs gallon semi water storage tank complete all as specfied & directed.
All as per Serial Item No. 1 above but 4.5 lakhs gallon semi water storage tank complete all as specfied & directed.
All as per Serial Item No. 1 above but 3 Lakh/2.5 lakhs gallon semi water storage tank complete all as specfied & directed.
All as per Serial Item No. 1 above but 2 Lakh/ 1.5Lakh/ 1.4 Lakhs gallon semi water storage tank complete all as specfied & directed.
All as per Serial Item No. 1 above but 1 Lakhs gallon semi water storage tank of Zero and Ist stage complete all as specfied & directed.
All as per Serial Item No. 1 above but 50000 /45000/40000 gallon water storage tank complete all as specfied & directed.
All as per Serial Item No. 1 but 10000 gallon water storage tank complete all as specfied & directed by Engg-in-charge. Note for item no 1 to 8 :-Date of cleaning shall be painted with synthetic enamel paint on sump complete all as specified & directed.
Excavation in trenches in any type of soil n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation laying of pipe etc n.exc 10 sqmm on plan and n.exc 1.5 mtr in depth and getting out complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not.exc 25cm each layers complete all as specified and as directed.
Removal of excavated material & surplus spoil to a distance n.exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Taking up or down existing GI pipe of following sizes from trenches / walls / roof / floor etc including connection and cleaning for refixing or removal from site and making good to distrubed area (surface of walls / floor etc) complete all as specified and as directed.
(a) GI Pipe 150 mm dia
(b) GI Pipe 100 mm dia
(c) GI Pipe 80 mm dia
(d) GI Pipe 40/50 mm dia
(e) GI Pipe 25 mm dia
(f) GI Pipe 20 mm dia
(g) GI Pipe 15 mm dia
S&F GI tubing, "medium grade" (Class B ISI Marked) with screwed joints or welded joints all as per site requirement incl all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge at water supply distribution system Lansdowne of following bore GI pipes :-
(a) GI Pipe 150 mm dia
(b) GI Pipe 100 mm dia
(c) GI Pipe 80 mm dia
(d) GI Pipe 50 mm dia
(e) GI Pipe 40 mm dia
(f) GI Pipe 25 mm dia
(g) GI Pipe 20 mm dia
(h) GI Pipe 15 mm dia
S&F GI tubing, "Heavy duty" (Class C ISI Marked) with screwed joints or welded joints all as per site requirement incl all fittings heavy duty complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge at water supply distribution system Lansdowne of following bore GI pipes :-
(a) GI Pipe 150 mm dia
(b) GI Pipe 100 mm dia
S & F in repair GI fitting (heavy Grade) ISI marked complete all as specified and directed for following sizes:- Note:- Site of fixing may be in any pumping installation at Lansdowne.
(a) GI socket of 80 mm Size
(b) GI union of 80 mm Size
(c) GI socket of 100 mm Size
(d) GI union of 100 mm Size
(e) GI socket of 150 mm Size
(f) GI union of 150 mm Size
Taking down the unserviceable sluice valve 150 mm dia installed in position and removed from site complete all as specified and directed.
All as per Item No. 16 above but 100 mm dia complete all as specified and directed.
All as per Item No. 16 above but 80 mm dia complete all as specified and directed.
S&F testing and connecting cast iron sluice valve heavy duty double flanged, 150 mm dia PN 1.6 confirming to IS 14846: 2000 ISI marked with Stainless steel spindle and two nos of MS flange of 16mm thick, 8 holes with nuts and bolts packing materials complete including cutting the existing watermain for fixing cast iron sluice valve and jointing welding complete required at site of water supply installations complete all as specified and directed. Make:- Kirloskar/L&T/Leader/ Zoloto
All as per Item No. 19 above but 100 mm dia complete all as specified and directed.
All as per Item No. 19 above but 80 mm dia complete all as specified and directed.
Disconnecting and taking down the existing unserviceable non return valves of cast iron and supply installing and testing of heavy duty cast iron non return valve PN 1.6 confirming IS 5312-1 (2004) ISI marked along with two Nos of heavy duty flange 16 mm thick, 8 hole sluitable for 100 mm dia with all fixing accessories such as suitable size nut and bolts of 16 Nos, packing material of leather buffalo including cutting the existing water main of 100 mm dia for fixing the non return valve, welding jointing complete as per site requirement at Zero/first/second/third stage/IInd lift/15 Lakh Gallon of water supply installations complete all as specified and directed.
All as per Item No 22 above but 80 mm dia As per site requirement at Zero/first stage/Jharpani water supply installations complete all as specified and directed.
Taking down the unserviceable gun metal gate valve 40/50 mm dia from installed position and removed from site complete all as specified and directed.
All as per Ser No. 24 above but 15 to 25 mm dia complete all as specified and directed.
S&F Gun metal gate valves of size 50mm ISI marked Class 150 confirmming to IS 778-1984 with iron wheel head, screwed both endsfor GI pipe complete all as specified and directed.
All as per Ser No. 26 above but 40 mm dia complete all as specified and directed.
All as per Ser No.26 above but 25 mm dia complete all as specified and directed.
All as per Ser No.26 above but 20 mm dia complete all as specified and directed.
All as per Ser No.26 above but 15 mm dia complete all as specified and directed.
M & L for construction of brick masonary valve chamber of internal size 900mm x 900 mm x 900 mm with foundation of PCC 1:4:8 type D2,(unsing 40mm graded stone aggreagate) brick work with sub class B bricks built in cement mortar 1: 4 with 15 mm plastering both internal and external surfaces (externally 15cm below GL) and 75 mm thick floor in PCC 1:4:8 type D2 (unsing 40mm graded stone aggreagate) and finishing the floor surface even & smooth using extra cement including provision of MS sheet cover 5mm thick surrounded by MS angle iron of size 40 x 40 x 6mm frame work embeded in 50mm thick PCC coping of 1:3:6 type C-2(unsing 40mm graded stone aggreagate) and painted with two coats of synthetic enamel paint over red oxide primer on steel surface including earth work and excavation in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
Fixing in repair valve pit chamber top cover of size 900x900 mm made with 2mm thick MS sheet with supporting MS angle iron frame made out of 40x40x6mm and painting with two coat of bitumen paint over a coat of red oxid primer and locking arrangment complete all as specified and directed. Note:- The Cost of connected civil works for fixing of valve chambers are deemed to be included in Quoted rates.
S&F in repair GI elbows/bend/unions/sockets/ tees/nipple with welding joint of 150mm water mains both ends for making leak proof between IInd lift to Stn HQ/SMT tank and any site of water supply installation all as specified and directed.
S&F in repair GI elbows/bend/unions/sockets/ tees/nipple with welding jointly of 100mm/80mm water mains both ends for making leak proof from Zero to IInd lift and or as per site requirement of water supply installation all as specified and directed. Notes for item No 33 and 34:- The cost of Fittings such as elbows/bend/unions/sockets/ tees/nipple etc shall be included in the unit rate quoted by the contractor.
M & L for angle iron work for support of water pipeline by welding at scattered location complete all as specified and directed.
M&L for walling of square rubble uncoursed well bonded, bedded and solidity hearted built in cement motor 1:6 for support for pipe line complete all as specified and directed. Note:- Site of work is hilly terrain which is not approachable by road
M&L for cement concrete 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in foundation, filling or mass concrete complete all as specified and directed
Cutting the existing floor/ roads for laying of GI pipe line and making good the distrubed surface with PCC 1:2:4 type B1 (using 20 mm stone aggregate) complete all as specified and directed.
M&L for complete removal of existing treatment by grinding the old surface and preparation of old painted surface by cleaning, rubbing with gunny bags/ wire brush and washing the entire surface with water mixed with bleaching powder and applying two coats of weather proof exterior acrylic emulsion paint with silicon additives over a coat of primer (Ist quality) entire surface of existing OH tank on staging incl columns, beams, cross beams, beams above slab, exterior surface of tank. The rate quoted by the contractor included all scaffolding arrangement to carryout the work on exterior surface of OH Tank from GF to top of existing tanks of any height. The application of paint shall be done with the roller/spray only. The contractor shall arrange all safety belt and all other equipment like helmets etc and shall be fully responsible for the safety of the labours. The contractor is advised to visit the site and work out the requirement before quoting the rates. The rate also includes minor repairs required and nothing extra shall be claimed by the contractor. Note :- The work shall be got executed by authorised applicator as approved by AGE(I). The complete materilas required for the work shall be brought by the contractor and depostied with the Engineer- in -charge.The stage after prepartion of surface by complete removal, application of primer, application of first and second coat shall be approved by AGE(I).
Disconnecting and taking down the existing unserviceable butterfly valves of cast iron and S&F testing and connecting cast iron butterfly valve lever operated heavy duty double flanged, 100 mm dia PN 1.0 confirming to IS 13095 ISI marked with Stainless steel stem and disc and two nos of MS flange of 16mm thick, 4 holes with nuts and bolts packing materials complete including cutting the existing watermain for fixing cast iron butterfly valve and jointing welding complete required at site of water supply installations complete all as specified and directed. Make:- Kirloskar/L&T/ Leader/ Zoloto
Supply and fix in repair LED flood light fitting 30 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on wall with 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from distribution box to light complete all as specified and as directed. Note:- (i) the firm has to give warranty for flood light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRSno Make:- Havells Cat No-JETAQUANTOPLUSFLP30WLED757SYM or Shakti Cat Part No-SZCFLMH030 or Crompton Cat Prt No-LFLN11-30-CDL
S&F in repair LED tube light batten 20 watts 4 fts polycarbonate housing, translucent diffuser with LED light source , 2200 lumen, natural white ,surge protection range- 2KV, voltage protection range 120-280 VAC , 2 years warranty ,system efficacy not less than 110 Lm/watt for the fitting , power factor>0.95 total harmonic distortation<20% , colour rendering index >80, coefficient colour temp 6500 K, fixed on site with all accessories all as specified and directed. Make:-Shakti Cat Part No-SZSLBMX020 OR Havells Cat Part No- LHEXARP71N1W 020 WLED757SASYTOPC OR Crompton Cat Part No-LDLSR20-CDL Note:- The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
M/S Balaji Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .