Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAdmitted-Finance | ₹5.5 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Fincantieri India Pvt Ltd L1 |
|---|---|---|---|---|
| 1.00CHARGES FOR 1ST YEAR | ||||
| 2.00SERVICE CHARGES | ||||
| 3.00 | Software up-gradation as and when required/obsolescence defects - This includes backend support from Seastema, Software being proprietary to the OEM. | 1 | EACH | 13,99,980 ₹13,99,980 Lowest |
| 4.00 | Rectification of breakdown defects and restoration of systems operability | 1 | EACH | 4,36,090 ₹4,36,090 Lowest |
| 5.00 | Defect identification and analysis of break down / recurrent failures. Generation of technial report (followed by sr 2 ) | 1 | EACH | 2,85,660 ₹2,85,660 Lowest |
| 6.00 | Adjustment of systems components and calibration - Does not include any software changes. | 1 | EACH | 4,63,115 ₹4,63,115 Lowest |
| 7.00 | Functional checks of interfaces with associated systems and equipment - Necessary interface data from the respective OEMs,if required, to be provided by IN | 1 | EACH | 4,64,555 ₹4,64,555 Lowest |
| 8.00 | Setting to work | 1 | EACH | 5,80,590 ₹5,80,590 Lowest |
| 9.00 | Post sailing assessment and generation of technical report on status of the system | 1 | EACH | 1,48,600 ₹1,48,600 Lowest |
| 10.00 | Software support, version control and de- bugging - This includes backend support from Seastema, Software being proprietary to the OEM. | 1 | EACH | 10,49,720 ₹10,49,720 Lowest |
Tender Value
₹2.7 Cr
EMD Value
₹9.0 L
Closing Date
7 Oct 2020, 12:00 pmClosed
CAPT RAKHI RAM
FMU(MBI) NAVAL DOCKYARD MUMBAI 400001
TENDER ENQUIRY FOR PRICE AGREEMENT FOR REPAIR MAINTENANCE OF INTEGRATED PLATFORM MANAGEMENT SYSTEM IPMS FITTED ONBOARD INS DEEPAK
2020_NAVY_378176_1
FMU/344/PA/IPMS
Single
Marine Services
Turn-key
365 days
FMU(MBI) NAVAL DOCKYARD
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
PCDA(NAVY)
₹9.0 L
28 Oct 2020
16 Sept 2020
8 Oct 2020
17 Sept 2020
7 Oct 2020
17 Sept 2020
17 Sept 2020 - 5 Oct 2020
Amount
CHARGES FOR 1ST YEAR
SERVICE CHARGES
Software up-gradation as and when required/obsolescence defects - This includes backend support from Seastema, Software being proprietary to the OEM.
Rectification of breakdown defects and restoration of systems operability
Defect identification and analysis of break down / recurrent failures. Generation of technial report (followed by sr 2 )
Adjustment of systems components and calibration - Does not include any software changes.
Functional checks of interfaces with associated systems and equipment - Necessary interface data from the respective OEMs,if required, to be provided by IN
Setting to work
Post sailing assessment and generation of technical report on status of the system
Software support, version control and de- bugging - This includes backend support from Seastema, Software being proprietary to the OEM.
System health checks using programming tool
Rectification of any fault in system panel (including server/clients CPUs and RIOs
Inspection and Tightening of panel Terminals(including RIO's , CPU's, Server/Clients)
Check health of the communication networks(Including communication between RIO's , CPU's, Server/ Clients and vice- versa) with cable and accessories.
Check of BDCS application as well as functionality on DCHQ console and its backup running of MCR server and CCR server
Replacement of Cabinet Door Filters and maintenance of panels and cabinets.
Examine and Repair of Faculty Analog/ Digital Input and Output cards
Examine and repair of any hardware and software faults in Main and RIO CPU's
Examine and Repair of Profibus Cards and DEIF's
Check the condition and Validation of IPMS Logic in all main and RIO PLC's
Replacement of faulty battery modules of RIO's and CPU cabinets
Backup of server/Clients hard disk after any software or hardware upgradation
Health checks of electrical insulation and grounding connection of the operators stations, RIO's and CPU's cabinet
Inspection and replacemnet of defective field sensor from OBS (onboard spares) if required
Problems associated external to the panel to be identified and solutions to be suggested
SPARES CHARGES
RX7I 17 SLOT RACK WALL (REAR MOUNT)
1.8 GHZ CPU, ETHERNET, REDUNDANCY
RX 7I POWER SUPPLY, 350 WATT 85 264VAC
DIGITAL OUTPUT MODULE 64 POINT
RX 7I PENTIUM M CPU _ 600MHZ WITH 64 MEG OF USER MEMORY
ANALOG INPUT MODULE 32 CHANNEL
ANALOG OUTPUT MODULE 16 CHANNEL - Obsolete
ANALOG OUTPUT MODULE 16 CHANNEL
DIGITAL INPUT MODULE 64 CHANNEL
RX 7I STANDALONE ETHERNET MODULE 10/100 - Obsolete
RACK COOLING FAN 115V
PAC SYSTEM RX 7I REDUNDANT MEMORY EXCHANGE 16 MB
PSM-ME-RS232/485-P (INTERFACE CONVERTER)
MINI-MCR-SL-PT 100-UI-NC- (TEMPERATURE TRANSDUCER)
MINI-MCR-SL-RPS-I-I-(N'16 FOR 1 ANALOG OUTPUT)
AC-DC CONVERTER QUINT PS-100-240AC/24DC/5
SWITCH ETERNET LEVEL 3
SWITCH ETERNET LEVEL 4
PROFIBUS DP CARD
CHARGES FOR 2ND YEAR
SERVICE CHARGES
Software up-gradation as and when required/obsolescence defects - This includes backend support from Seastema, Software being proprietary to the OEM.
Rectification of breakdown defects and restoration of systems operability
Defect identification and analysis of break down / recurrent failures. Generation of technial report (followed by sr 2 )
Adjustment of systems components and calibration - Does not include any software changes.
Functional checks of interfaces with associated systems and equipment - Necessary interface data from the respective OEMs,if required, to be provided by IN
Setting to work
Post sailing assessment and generation of technical report on status of the system
Software support, version control and de- bugging - This includes backend support from Seastema, Software being proprietary to the OEM.
System health checks using programming tool
Rectification of any fault in system panel (including server/clients CPUs and RIOs
Inspection and Tightening of panel Terminals(including RIO's , CPU's, Server/Clients)
Check health of the communication networks(Including communication between RIO's , CPU's, Server/ Clients and vice- versa) with cable and accessories.
Check of BDCS application as well as functionality on DCHQ console and its backup running of MCR server and CCR server
Replacement of Cabinet Door Filters and maintenance of panels and cabinets.
Examine and Repair of Faculty Analog/ Digital Input and Output cards
Examine and repair of any hardware and software faults in Main and RIO CPU's
Examine and Repair of Profibus Cards and DEIF's
Check the condition and Validation of IPMS Logic in all main and RIO PLC's
Replacement of faulty battery modules of RIO's and CPU cabinets
Backup of server/Clients hard disk after any software or hardware upgradation
Health checks of electrical insulation and grounding connection of the operators stations, RIO's and CPU's cabinet
Inspection and replacemnet of defective field sensor from OBS (onboard spares) if required
Problems associated external to the panel to be identified and solutions to be suggested
SPARES CHARGES
RX7I 17 SLOT RACK WALL (REAR MOUNT)
1.8 GHZ CPU, ETHERNET, REDUNDANCY
RX 7I POWER SUPPLY, 350 WATT 85 264VAC
DIGITAL OUTPUT MODULE 64 POINT
RX 7I PENTIUM M CPU _ 600MHZ WITH 64 MEG OF USER MEMORY
ANALOG INPUT MODULE 32 CHANNEL
ANALOG OUTPUT MODULE 16 CHANNEL - Obsolete
ANALOG OUTPUT MODULE 16 CHANNEL
DIGITAL INPUT MODULE 64 CHANNEL
RX 7I STANDALONE ETHERNET MODULE 10/100 - Obsolete
RACK COOLING FAN 115V
PAC SYSTEM RX 7I REDUNDANT MEMORY EXCHANGE 16 MB
PSM-ME-RS232/485-P (INTERFACE CONVERTER)
MINI-MCR-SL-PT 100-UI-NC- (TEMPERATURE TRANSDUCER)
MINI-MCR-SL-RPS-I-I-(N'16 FOR 1 ANALOG OUTPUT)
AC-DC CONVERTER QUINT PS-100-240AC/24DC/5
SWITCH ETERNET LEVEL 3
SWITCH ETERNET LEVEL 4
PROFIBUS DP CARD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
tenderenquiry.pdf
Tender Documents • 0.16 MB
BOQ_421941.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .