Loading…
Loading…
Tender Value
₹14.3 Cr
EMD Value
₹14.3 L
Closing Date
21 Apr 2026, 6:00 pmClosed
Executive Engineer, Water Works Department.
CONSTRUCTION OF 24 ML RAW WATER GSR INCLUDING TWO YEARS OF O & M AT SIDSAR IN WESTER AREA OF BHAVNAGAR
291930
BMC/WATER WORKS/34/MARCH 2026
Open
Civil Works - Water Works
Bhavnagar
5 documents required · 3 mandatory · 2 optional
₹18,000
Commissioner, Municipal Corporation, Bhavnagar
₹14.3 L
31 Mar 2026
31 Mar 2026
31 Mar 2026
21 Apr 2026
31 Mar 2026
Raw Water G.S.R In Western Area Schedule B
Name Of Work : CONSTRUCTION OF 24 ML RAW WATER GSR INCLUDING TWO YEARS OF O & M AT SIDSAR IN WESTER AREA OF
Sr. SOR Rate in Amount
Description Unit Quantity
1 Clearing and grubbing road land including uprooting rank vegetation grass
bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier
and disposal of unserviceable materials (C) By mechanical means in area of light jungle
2 Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful
materials and disposing off the excavated stuff upto 50 Meter lead.(C) Hard Murrum
3 Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking
of useful materials and disposing off the excavated stuff upto 50 Meter lead.(C) Hard
4 Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking
of useful materials and disposing off the excavated stuff upto 50 Meter lead. (D) Soft rock
not requiring Blasting UGSR (1.50 m to 3.00 m) Cum 1,175.40 304.12
5 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking
of useful materials and disposing of the excavated stuff upto 50 Meter lead.(C) Hard
Murrum (3.00 m to 5.00 m) Cum 752.70 304.12
6 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking
of useful materials and disposing off the excavated stuff upto 50 Meter lead.(D) Soft rock
not requiring Blasting (3.00 m to 5.00 m) Cum 4,516.20 328.23
7 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking
of useful materials and disposing off the excavated stuff upto 50 Meter lead.(E) Hard Rock
8 Extra for additional depth more than 5.0 m for excavation for foundation including sorting
out and stacking of useful materials and disposing off the excavated stuff upto 50 m
lead.(D) Soft rock not require Blasting Cum 4,020.50 367.81
9 Extra for additional depth more than 5.0 m for excavation for foundation including sorting
out and stacking of useful materials and disposing of the excavated stuff upto 50 m
lead.(E) Hard Rock Cum 4,020.50 723.85
10 Dewatering by pumping set
Dewatering by pumping set of required capacity including temporary platform carting
pumping at site and fixing the same in position including all accessories, and fuel and
labour etc. complete. HP/hr 11,300.00 18.32
11 P.C.C.M-10 levelling course
Providing and laying cement concrete 1:3:6 (1-Cement : 3-coarse sand : 6- hand broken
stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in
(A) Foundation and Plinth Cu.mt 32.00 3075.91
12 Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone
aggregates 20 mm nominal size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
PCC for CC Road works Cu.m 34.00 3,786.24
13 Providing and casting in situ C.C. in grade M-15 (porportions as per mixdesign or as per
Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of
size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle
vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and shuttering etc. comp. for structure
for other than water retaining. Footing for column or foundation (with form work)
14 Providing and casting in situ controlled cement concrete M-250 for R.C.C. return as per
drawings including centering shuttering, scaffolding where necessary, laying vibrating,
curing and finishing complete But excluding cost of reinforcement for reinforced concrete
work in foundation, footings, base of columns and mass concrete CC M25 FOR Column
footing (Only Fresh Play & Steel props shall be used). Cu.mt 25.00 5205.92
15 Providing and casting in situ controlled cement concrete M-250 for R.C.C. return as per
drawings including centering shuttering, scaffolding where necessary, laying vibrating,
curing and finishing complete But excludingcost of reinforcement for reinforced concrete
work in CC M25 FOR GROUND BEAM (Only Fresh Play & Steel props shall be used).
16 Providing and casting in situ controlled cement concrete M-250 for R.C.C. return as per
drawings including centering shuttering, scaffolding where necessary, laying vibrating,
curing and finishing complete But excluding cost of reinforcement for reinforced concrete
work in foundation, footings, base of columns and mass concrete CC M25 FOR Column
footing (Only Fresh Play & Steel props shall be used). Cu.mt 14.00 7638.63
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
17 Providing and cast in situ C.C. in grade M-30 proportions of ingredients as per mix design
by weigh batching using granite, quartzite trap metal of size 12 mm to 20 mm and or 6 mm
to 20 mm including scaffolding formwork, needle vibrated consolidation, curing and
hydraulic testing etc. complete (excluding cost of reinforcement) with centering and
shuttering/deshuttering etc. comp. up to required height or depth from average G.L. for
all water retaining structures.
Base Raft Cu.M. 3,602.00 8,213.00
18 Column Footing Cu.M. 23.00 8,213.00
20 Top Slab Cu.M. 56.00 8,412.00
21 Columns Cu.M. 43.00 9,317.00
23 Stairs Cu.M. 8.00 8,486.00
24 Chhajja Cu.M. 3.00 8,486.00
25 Lintel Cu.M. 2.00 8,486.00
26 Providing and Casting in situ controlled Cement Concrete M-30 for R.C.C. Raft and cutt-off
walls Excluding necessary shuttering laying, vibrating, ramming and curing complete.
(Minimum Cement content 410 Kg/cum) for all RCC works. Cu.m 45.00 4,855.99
27 Providing TMT Bar FE 500D reinforcement for R.C.C Work including bending, binding and
placing in position complete upto floor two level Kg 10,950.00 76.52
28 Supplying, cutting,bending, binding and placing in position steel as per plan and design
and as per ISS 2502 including cost of steel and binding wire for reservoir /structures only
including lift up to 6 mt. height or depth below G.L. for all diameters.
Do- CRS steel all diameter Fe 500 garde confirming to relevant I.S MT 677.00 78,577.00
29 Providing fusion bonded Epoxy coating not less than 175 micron thickness and up to
micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of
coating at plant and all taxes (A) 10mm to 16mm dia bar M.T. 11.90 10062
30 Brick work using common burnt clay building brick having crushing strength not less than
35 kg/sq.cm in foundation and plinth in Cement Mortar 1:6 (1-Cement : 6-Fine sand)
(B)Conventional cu.m. 206.57 4,237.60
31 Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations
etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by
ramming and watering. cu.m 361.10 136.11
32 Filling in foundation and plinth with murrum or selected soil in layers of 20 cm thickness
including watering , ramming and consolidating etc. complete. cu.m 3,249.90 301.58
33 Carriage of Earth. 3km. (more than 10 ton)
Disposal of earth cu.m 23,750.00 23.66
34 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M . 1:3(1-cement : 3-sand) and 8mm thick
finishing coat of C.M . 1:1 (1-cement : 1-sand)etc. complete. Sq.mt. 1,333.00 347.1
35 Cement plaster 20 mm thick in C.M. 1:2 using water proofing compound of approved
quality including finishing etc. complete. sq. M. 3,480.00 202.00
36 Providing 15 mm thick cement plaster in single coat on Rough (similar)side of single or half
brick walls for interior plastering upto floor two level and finished even and smooth
in(i)cement mortar 1:3(1-cement : 3-sand) sq. M. 625.00 198.10
37 Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded
stone aggregate 20mm nominal size) laid in one layer and finished with a floating coat of
neat cement. (A) 40mm thick.
IPS Flooring Sqm 3,047.00 294.60
38 Extra for providing and mixing water proofing material in Cement concrete in mix Litres or
proportion recommended by the manufacturers. @ 0.50 kg or 0.50 liter water proofing Kg per
compund per 1 bag of cement Quintal
Cement 774.00 48.67
39 Providing PVC water stopper at transverse construction and joints as per IS: 15058 :2002
of water and fixing in concrete walls and check leakage.
150mm wide thin ribbed PVC sheet Rmt. 3,504.00 330.00
40 Providing and laying polished kota stone slab flooring over 20 mm (Average) thick base of
cement mortar 1:6 (1 cement: 6 coarse sand) or L.M. 1.1.5(1-Lime putty :1.5-coarse sand
sand) laid over and joined with grey cement slurry mixed with pigment to match the shade
of slab including rubbing ]and polishing etc. complete. (A) 25 mm thick Sqm 258.00 1,009.30
41 Providing and laying broken china mosaic flooring for terrace using 12mm to 20 mm
broken piece of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out up to surface using white cement including rounding
off junctions and extending them up to 15 cm along the wall, clearing with water and
oxalic acid etc.as directed by engineer in charge.
Pump room terrace Sqm 155.00 771.98
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
42 Providing and fixing 35 mm thick shutter for Doors, windows and clerestory windows
including Indian teak wood frames 10 cm x 7 cm. size including black enamelled iron
oxidixed fixtures and fastening including primer coat of approved quality and two coats of
oil painting etc complete. II) fully panelled Sqm 26.00 5,285.45
43 Providing and fixing standared extruded of alluminium section of size 63mm x 38.10mm x
1.2mm (Jindal Section :2434, @ Wt. 0.643 Kg/mt) with colour anodized alluminium frame
for ventilation with 5 mm thick frosted glass as details etc complete for Ventilation
(Anodized from factory)
44 Providing and fixing M.S. Grills of required pattern to wooden frames of windows etc.
with MS flats at required spacing and frame around square or round bars with round
headed bolts and nuts or by screw (A) plain grill kg 1,037.00 107.68
45 Providing fabricating and fixing / installing C.I. gates of size as per enclosed drawings with
operating handle etc. for by pass arrangement With ISI Mark
C.I. Gates KG 500.00 82.00
46 Providing and fixing rolling shutter of approved make made of 80 mm wide M.S laths
interlocked togather at their entire length and jointed together at the ends by end locks
mounted on specially designed pipe shaft with bracket plates, guide channels and
arrangement for inside and outside locking with push-pull operation including the cost of
hood cover and spring etc. complete.
(A)Shutter having width below 3.5M. Sqm 16.00 3,519.21
47 Applying two coats of putty & two coats of primer of approved brand and manufacture on
new wall surface to give an even shade including thoroughly brushing the surface free
from mortar dropping and other foreign matter and sand papered smooth. Sqm 1,959.00 40.19
48 Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture
on undercoated wall surface to give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter and sand papered smooth.
49 Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to
give an required shape even shade after thoroughly brushing the surface to remove all
dirt, and remains of loose powdered material etc. complete or as directed by engineer in
charge. Sqm 2,683.00 120.93
50 Water Level Indicator/ Depth Gauge
Providing and fixing Water Level Indicator or depth gauge painted on TW plank 25 mm/MS
plate 4 mm thick float, level indicator sliding wire on standard pulleys incl. necessary
arrangement to prevent the swinging etc. complete with calibration up to 5 mt height.
51 Fixing water level indicator
Labour charges for fixing wooden / steel water level indicator including all accessories and
jointing material etc. complete.
For Sump No. 1.00 513.00
52 Ultrasonic Type Level Transmitter with Remote Display : Design, Supply, Installation,
Testing and Commissioning of NOn Contact Ultrasonic Type Level Transmitter with Remote
Display. Sensor:The sensor should be non contact type, field mounting type, housing shall
have minimum IP65 protection, PP/ PVC Sensor MOC, with sensor to transmitter
cable.Remote Indicator cum Transmitter: Microprocessor based indicator with LED / LCD
digital display,panel/ wall mounting type, power supply shall be 110-240 Vac or 15 to
Vdc, 50 Hz ± 10 %.Accesories: Mounting bracket, nut, bolts etc as per system requirement
and Hook up diagram of the Instruments. Level Transmitter shall be suitable for following
ii)0 to 10 Meter No. 1.00 59,436.00
53 Providing and supplying D. I. K-9 grade pipes for following nominal bore diameter with
internal cement mortar lining including all taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading, unloading, conveyance to departmental
stores, stacking etc. complete. (IS 8329-2000). Rate for DI pipe based on wholesale price
index of pig iron as 157.60 for the month of Dec-2022.
600 mm dia DI k-9 Pipe ( For Inlet chamber) Rmt. 18.00 10,309.00
54 RCC PIPE (vertically cast)
Providing and supplying ISI Standard R.C.C. pipes(of Sulphate Resisting Cement) in
standard lengths of following class and diameter suitable for either collar joints or rubber
ring joints including all taxes, insurance, transportation, freight charges, octrol, inspection
charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
For overflow arrangement
Class NP3 Test Pressure 0.7 Kg/sq.cm
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
Manufacture, Supply & Delivery of Electric Resistance Welded (Up to 400mm)/Submerged
Arc Welded(Above
400mm) M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its
latest revision/ ammendment for following thickness outside diameter at GWSSB store or
site anywhere in Gujarat State including all taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading, unloading conveyance to Departmental
stores, stacking etc. all complete. (Rate for MS Pipe based on the ex. works price of HR Coil
as Rs.58500 per MT - withouth GST (Above 3.15 mm to 10 mm) & Rs. 59000.00 per MT
without GST (Above 10 mm) as onJan-23.( WPI Index of H. R Coil of Dec-22 is 144)
I/S Solvent free Liquid Epoxy Lining (406 micron) + O/S 3 LPE Coated M. S. Pipe
Pipe dia in OD 323.9 5.6mm thickness RMT 33.00 3,293.00
56 Pipe dia in OD 457.0 6.3mm thickness RMT 42.00 4,662.00
57 Lowering, laying and jointing D.I. S & S Spun pipes suitable for Tyton joints / Mortar lined
D. I. Pipes of various classes with CI / MS specials of following diameters in proper position,
grade and alignment as directed by Engineer-in-charge including hydraulic testing etc.
600 mm dia DI k-9 Pipe ( For Inlet chamber) Rmt. 18.00 404.00
58 Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees, reducers
or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for use with D.I.
Pipes manufactured as per IS:8329/1994delivery of specials is to be made to
(departmental store) or site of works any where in Gujarat including all taxes, loading,
unloading, carting, stacking, insurance, inspection charges, octroi etc. complete.
59 Lowering, laying and jointing R.C.C pipes in C.M. 1:1 1/2 of following diameter in proper
position, grade and alignment at all level as directed by Engineer in charge including
conveyance from stores to site of work, labour, giving hydraulic testing as per ISI code.
Class NP3 Test Pressure 0.7 Kg/sq.cm
60 Lowering, laying, jointing & welding in position to correct line & level M.S. Pipe with
outerside 3 LPE coating & inside solvent free liquid epoxy lining on pedestal or chairs upon
prepared formation or prepared bedding in trenches the rates include conveyance from
store to site of work loading, unloading, heat shrink sleev jointing hydrotesting
Welding in all positions with required number runs, for M.S.Pipes internally and/or
externally including gauging wherever necessary, fixing appurtenances and other
accessories in connection with pipe laying work as per specification.As Above for Butt
joint:Plate thickness
1) welding for Pipe thickness 4mm to 7mm
63 Gas Cutting of MS Pipe / Plates
Gas cutting(Either square cut or V cut) pipes, plates etc. including all costs for the followng
2) Above 5mm up to 10mm RMT 40.00 56.00
64 MS Specials flange ended
1) Up to 300mm dia. Kg. 950.00 98.00
66 Sluice valve
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of
following class and diameter including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores,
stacking etc. complete.
PN-1.6 With gear operated (Ait-1 type long body)
69 PN- 1.6 600 mm (For inlet arrangement) Nos. 2.00 1,63,813.00
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
70 Reflux valves
Provide and supplying ISI mark CI D/F reflux valve as per IS: 53112 (latest edition) of
follwing class and diameter including alll taxes, insurance, transportation, frieght charges,
octroi, inspection charges, loading, unloading, conveyance to departmental strores,
stacking etc. complete.
Reflux valves PN 1.6 IS 5312 with ISI mark
Providing and supplying C.I Temper proof Air valves with SS 304 float gun metal- nozzle of
approved make & quality of following class and diameter including all taxes, insurance,
trasportation, freight charges, octroi, inspection charges, loading, unloading, conveyance
to departmental store, stacking etc. complete.
With Isolating sluice valve PN
73 Lowering, laying and jointing in position following C.I. D/F Reflux valves, Butter flyvalves,
Sluice valves and Air valves including cost of all labour, jointing material, including nut
blots and giving satisfactory hydraulictesting, etc.complete (Rate for all classof valves)
Sluice valve / BF valve
Air valves double ball flanged - 50mm Nos. 1.00 379.00
74 Sluice Valves - 50mm Nos. 1.00 378.00
75 Sluice Valves - 300mm Nos. 3.00 1,141.00
76 Sluice Valves - 450mm Nos. 1.00 2,760.00
77 Sluice valveS - 600 mm No. 2.00 3,967.00
78 Reflux valve - 300mm Nos. 3.00 1,141.00
79 Reflux valve - 450mm Nos. 1.00 2,760.00
80 Construction of valve chamber in brick locally available in CM 1:6 Foundation concrete
mm thick in CC 1:4:8 of trap metal size 25mm to 40 mm thick, inside cement plaster in C.M
1:3 &cement pointing out side in C.M 1:3 and top cover or precast RCC slab 100 mm thick
(with key hole in two patrs, each with handles or MS Bar etc.comp. as given size) Up to
Mt depth from GL to pipe invert level including complete civil works but excl. cost of
excavation & refilling. With cast in situ RCC slab in one single piece with of C.I.M.H Frame
& cover. (excl. cost of C.I.M.H Frame & cover) with 23 mm thick brick masonary wall in
81 Sewer Manholes
Providing and constructing Sewer manhotes. scraper manholes and unit house connection
chamber, as per the type design in brick masonry in C. M. 1:5 and inside and outside
20mm thick plastering in C. M. 1:3 necessary 100 mm coping wilh reinforcement in
R.C.C.M. 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply
of manhole frame and covers) over manholes and house connection chambers and fixing
Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc.
complete. providing and fixing safety chain wherever necessary as per the stipulations in
the type design complete as per latest CPHEEO manual.
(excl. excavation).
C) Manhole type "c" circular type having inside diameter of minimum 1500 mm and for
depth beyond 4.0 m to 6.0 m (for 150 mm to 1800 mm dia sewers)
1. Manhole type "C" as above but upto 4.0 m depth.
82 (a) MS iron Ladder (without safety cage)
Providing and fixing 50 cm wide M.S. Ladder fabricated from M.S. flats 10 mm x 75 mm
with 20 mm dia steel bar steps in double rows, @ 30 cm c/c. the include stays of 10 mm x
50 mm flats fixed at 3 meter c/c with welding anchoring and 3 coats anticorrosive paint.
83 (b) M.S. Monkey ladder (with safety cage) Kg 165.00 67.00
84 Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B)
conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall
using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every
2000 mm center to center or shall be concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
For Rain Water Disposal
Pumping Room Terrace Rmt 10.00 888.90
85 Painting letters
Painting letters for "Capacity of tank" the size of letters will be 45 cm height and 50 mm
width. No. 50.00 34.00
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
86 Providing and fixing aluminium zinc alloy metallic coated steel sheet for roofing as per IS
15965:2012, having BMT 1.40 mm and AZ 150 (Class 3, Category C3 or higher) coating
class, fixed with rain water gutter & S.S 304 grade with polycarbonate, Base plate Length-
1800 mm, Fins- aluminium Dia - 24" Inch air turbo ventilator on roof complete work.
(Make: JSW, TATA)
Note: The agency shall have to submit the detail structural design and working drawings of
roof sheeting for the approval of client. The work shall be started only after approval of
87 Providing and fixing pre-moulded compressible filler board in black colour confirming to
MoRT&H Specifications (Clause 1015), having minimum density 95kg/cum.metre, non-
staining with less than 1% water absorption & compression recovery of 93% minimum as
per specification for 40 mm wide expansion joint including cutting to required size and
shape at all levels etc. complete as directed Sq.mt 9.00 1317.74
88 Providing and Fixing 'Y' Shaped Barbed wire fencing on compound wall top with verical
angle of 50x50x6mm & 0.50 Mtr height @ 3.0 mt. c./c, two cross angles 50x50x6 mm &
0.45 Mtr. Length, having 3 Horizontal and two diagonal rows of barbed wire(9.38 kg/100
rmt) on vertical angle and three horizontal and two diagonal barbed wire rows on each
cross angles incl. cost of barbed wires, necessary GI stapplings, fixing in column of Cement
concrete in 0.20 mt depth, on top of compound wall, painting angles with one coat of
anticorrossive primer and two coats of enamel paint of approved quality, necessary
scaffolding etc. complete as per the direction of the Engineer in Charge.
89 Compound Gate
Steel work welded in built up sections framed work including cutting ,hoisting,fixing in
position and applying a priming coat of red lead paint (A) In beams and joists, channels
angles Tees, flats , with connecting plates or angle cleats as in main and cross beams. HIp
and jack rafters, purlins connectes to common ratfters and the like. q 5.00 9018.3
90 Stabilization of existing ground soil of road base by excavation up to 200mm depth,
pulverizing the soil using equipments like disc harrows, rotavators or any other suitable
machineries to make soil in finer size, removal of vegetation or any other deleterious
matter, stumps of trees, including excavation of existing base, stacking of soil, spreading
of soil in layer, mixing with using lime - Flyash admixture with excavated sub base soil,
free from organic matter/ deleterious material . The lime shall be commercial dry lime
confirming latest revision of IS 1514, slaked at site or pre-slaked with CaO content not less
than 70 per cent, Fly ash to conform to latest revision of IS 3812 gradation as per clause
4.3 of IRC: 88-1984, lime + fly ash content ranging approximately 10 to 30 per cent, ratio of
lime: fly ash : soil shall be approximately 3:12:85 or both of proportions as per design mix
to achieve the minimum CBR value after 4 days soaking to be 8 per cent in laboratory and
For CC Road works Cu.m 45.00 319.00
91 Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam
(WMM) in two layer as per specification and drawing including premixing the Material
with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site,
laying in uniform layers with paver in sub- base / base course on well prepared surface
and compacting with vibratory roller to achieve the desired density as per MORT&H fifth
revision clause-
For CC Road works (wmm) Cu.m 45.00 1,173.00
92 Providing & laying of 150mm compacted thickness Granular sub base (GSB) in grading V
in table 400-1 of the specification MORT&H fifth revision and compactor to the required
density with 8 - 10 tonne vibratory roller with plain drum or heavy pneumatic tyred roller
of minimum 200 to 300 KN weight in all seasons as per MORT&H , maintaining the
required slope & grade during the operation as approved by the engineer in charge &
watering to the proper moisture content and sprinkled with the help of truck mounted
water tank fitted with suitable arrangement .
(fully saturated having CBR value greater or equal to 30)
For CC Road works (GSB) Cu.m 34.00 999.00
93 Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of M250 grade concret as per approved design
and including excavation for fixing in proper line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete. Rmt 90.00 371.21
94 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm
thick with grade of concrete M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in proper line and level as per guidlines of IRC : SP
63-2018 etc. Complete.
Paver blocks in the side area of USSR and in the parking area. Sqm 1,630.00 700.54
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
95 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of
serviceable materials and then disposing of surplus soil, by spreading and neatly levelling
within a lead of 50 m and making up the trenched area to proper levels by filling with
earth or earth mixed with sludge or / and manure before and after flooding trench with
water (excluding cost of imported earth, sludge or manure). cum 468.00 119.00
96 Supplying and stacking of good earth at site including royalty and carriage upto 5 km
complete (earth measured in stacks will be reduced by 20% for payment). cum 208.00 803.75
97 Supplying and stacking sludge at site including royalty and carriage upto 5 km complete
(sludge measured in stacks will be reduced by 8% for payment). cum 104.00 431.75
98 Supplying and stacking at site dump manure from approved source, including carriage
upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :
4.1 Screened through sieve of I.S. designation 20 mm cum 52.00 391.35
99 4.2 Screened through sieve of I.S. designation 16 mm cum 52.00 447.05
100 4.3 Screened through sieve of I.S. designation 4.75 mm cum 52.00 491.65
101 Rough dressing the trenched ground including breaking clods. sqm 1,040.00 2.30
102 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water
including disposal of uprooted vegetation. sqm 1,040.00 7.45
103 Fine dressing of the ground. sqm 1,040.00 5.60
104 Spreading of sludge, dump manure and/or good earth in required thickness as per
direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid
separately). cum 468.00 79.70
105 Mixing earth and sludge or manure in the required proportion specified or directed by the
Officer-in-charge cum 468.00 55.70
106 Supplying & Stacking of Selection No.1 Grass at site fresh & free from weeds having proper
roots in green including loading, unloading, carriage and all taxes paid etc.and as per
direction of officer in charge. Per sqm 1,040.00 64.70
107 Grassing with selection No. 1 grass including watering and maintenance of the lawn for
days or more till the grass forms a thick lawn, free from weeds and fit for mowing
including supplying good earth, if needed (the grass and earth shall be paid for separately).
10.1 In rows 5 cm apart in both directions
108 10.2 With grass Turf sqm 1,040.00 20.30
109 Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering
and removal of unsaverieable material’s as per direction of officer in charge (excluding
cost of plant & water).
Trees Plant (Every 2mt.) Each 200.00 9.45
110 Shrubs Plant Each 200.00 4.70
111 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with
manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after
reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding
with water, dressing including removal of rubbish and surplus earth, if any, with all leads
and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
Holes 90 cm dia, and 90 cm deep
112 Holes 45 cm dia, and 45 cm deep. Each 200.00 20.65
113 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size
HDPE bag as per direction of the officer-in-charge. Each 200.00 97.50
114 Providing and stacking of Polyalthia longifolia (Ashok) height 180-195 cm. in gunny bag
size 30 cm as per direction of the officer-in-charge.
At every 2 mt. Each 200.00 108.35
115 Electro mechanical components of Pumping Station having installed capacity up to ≤
kW with working load not exceding 75 KW.
Supply, installation, testing & commissioning of electro-mechanical equipment of water
supply pumping system viz. pumping machinery (of following type & rating), valves
(SV/BFV/DPCV), Suction-delivery-discharge header pipes & specials, expansion bellows,
flow meter (full bore electromagnetic - For size ≤ 1400 mm) / ultrasonic - For size ≥
mm), material handling system (motorised chain pulley block with geared travelling
trolley), vaccum pumps with accessories or horizontal mono submersible (drain) pump
with accessories including LV MCC - APFC panels, LV XLPE insulated Cu / Al armoured / PVC
insulated round Copper submersible cables with tray & kits, earthing system, fire
extinguisher, exhaust fan, safety accessories etc. as per specifications.
Header Pipe Dia in ID 450mm & Dilevery pipe
Volute type submerged centrifugal Pump
94.70 lps, 18 M Head, (2W + 1S)
Each pump set of Tentative 38 KW x 3No. KW 114.00 27,663.00
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
116 Expansion Below
Supply, testing & commissioning of flange ends expansion bellow as per EJMA standards of
overall length of minimum 300 mm, designed for 15 mm axial compression and 5 mm axial
extension with tie rods etc. of following MOC & pressure ratings.
MOC: Bellows: SA 240 Gr. 304; Internal sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B;
Flanges: IS 2062 Gr. B (Drilling as per IS 1538 / IS 6392) & Limit rods & nuts: CS - IS
118 Full Bore Electromagnetic Flow Meter- Regular Power operated
Design, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow
meter with factory calibrated,Regular Power Operated, flanged connection, Flow sensor,
Indicator, transmitter and totaliser with all accessories viz.surge arrestor, associated
cables, cabinets, hardwares, etc complete as per following specifications:
Flow Transmitter/ Converter ( Remote Field Mounted):
Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate,
forward, reverse, sum totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity, 4 to
mA with HART/Modbus output, one scalable pulse, one status output, IP 67 protection,
Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass
window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to
transmitter communication etc alongwith wall mounted/ stand mounted cabinet.
Full Bore Electromagnetic Flow Meter (Regular Power Operated)- PN
For PN 16 rating, 10% rise in rate to be considere on rate of PN 10 rating Item (Item No.
(13)450mm Nominal Bore
119 Pressure Gauges with Accessories
Design, Supply, Installation, Testing, Commissioning of Diaphragm sealed Pressure Gauge,
±1% accuracy, Direct bottom 1/2" NPT (M) process connection, IP 67, Glycerine filled,
SS304 Case with Bayonet Type Bezel, SS316 L Diaphragm, SS316 Bottom Housing Material,
SS 316 Movement material, Aluminium dial with black graduation on white background,
Micro Zero adjustable pointer, neoprene gasket, Blow out disc, shatter proof glass, SS tag
plate etc as per IS
(b) 150 mm Dial Size, 0 to 21 Kg/cm2 Nos. 3.00 3,012.00
120 Pressure Transmitter
Design, Supply, Installation, Testing and Commissioning of Sealed Diaphragm Type
Pressure Transmitter.
Piezo-resistive sensor technolgy based pressure transmitter with Micro-processor based
integral LED/ LCD display, with accuracy of ± 0.3% of span, external zero and span
adjustment, self diagnostics, temperature sensor for compensation. 15 to 36 V DC power
supply, output signal of 4-20 mA DC with HART. Minimum IP 65 degree of protection.
Aluminium housing with epoxy coating, Accessories like snubbers for pump discharge
applications, three way manifold, mounting brackets, name plate etc. Material for
accessories shall be SS. Protection Box/Canopy shall be provided for outside installed
transmitters. Pressure Transmitter shall be suitable for following Range.
121 Ultrasonic Level Transmitter
Ultrasonic Type Level Transmitter with Remote Display : Design, Supply, Installation,
Testing and Commissioning of NOn Contact Ultrasonic Type Level Transmitter with Remote
Sensor: The sensor should be non contact type, field mounting type, housing shall have
minimum IP65 protection, PP/ PVC Sensor MOC, with sensor to transmitter cable. Remote
Indicator cum Transmitter: Microprocessor based indicator with LED / LCD digital
display,panel/ wall mounting type, power supply shall be 110-240 Vac or 15 to 36 Vdc,
Hz ± 10 %. Accesories: Mounting bracket, nut, bolts etc as per system requirement and
Hook up diagram of the Instruments. Level Transmitter shall be suitable for following
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
122 LV MCC Panel
SITC of LV MCC Panel totally enclosed, dust & bermin proof, indoor type, minimum degree
of protection - IP 52 as per IS: 2147, operation on 3-Phase, 4 Wire, 415V, 50Hz, Neutral
effectively grounded, with instrumentation compartments accomodating LED type
indicating lamps, control contactors as per IS: 13947, CT of accuracy class- I as per IS:
relays, meters & control MCBs, air insulated electrolitic grade Aluminum bus bar for three
phase & neutral system with incomming breaker- microprocessor based Air Circuit
Breakers (electrically operated drawout type)/ air break fixed type MCCB with trip free
mechanism, current limiting type as per IS: 8828, Motor Contractor (as per type -2
coordination), Overload Relay with built-in single phasing prevention feature & auxiliary
feeders as per SLD drawings, momentary contact type push buttons, equipment fittings,
bus bars, cable boxes, cable gland, incoming & ougoing cable connection for 1100V grade,
Aluminium/ Copper conductor XLPE / PVC insulated & PVC sheathed armoured cable, 10%
spare terminals, power wiring using 1100V grade, FRLS insulated copper conductor wires
conforming to IS: 694 - - - -
& 8130, cable compartments / alleys of minimum 300 mm size, GI / Al earth bus bar for
entire length. MCC shall be fabricated from cold rolled, coled annealed (CRCA) sheet steel
& minimum thickness of various members shall be as follows:
Base Frame / Channel / Gland Plate: 3 mm, Load Bearing Members / Doors: 2 mm and
Internal Partitions: 1.6 mm(1500 x 600 x 2175)
Auto Transformer Starter with MCCB, Contactor, O/L relay, cast resin type CT, Digital
MFM, Analogue Ammeter, SPP, Timer etc.
123 Microprocessor Based LV Variable Frequency Drive
Supply, installation, testing & commissioning of 415 V Fully automatic microprocessor
based Variable Frequency drive for pump control application as per general specification
The VFD unit shall have modular construction, 6 Pulse Bridge rectifier, speed control by
means of sensorless vector control (open loop), high torque at low frequencies, locking at
high and low frequency settings, In-built PID control, frequency accuracy of ± 0.1 % (min),
frequency resolution of ± 0.1 Hz (min), protections against; a) overload (motor and drive),
b) short circuit, c) ground fault, d) input / output phase loss (open circuit), e) stalling, f)
input / output undervoltage (momentary power loss restart), g) input / output
overvoltage, h) over-frequency, i) Input surge, j) over temperature of heatsink, k) loss of
remote speed signal etc. The VFD shall also have user friendly programming software & it
shall be - - - -
capable of at least two level parameter setting with password lock for critical parameters,
programming for I/Os, speed search function, copy parameters (upload / download) to
other identical unit, tuning to energy saving mode (maximum efficiency), event / fault
recording (last 5 faults in non-volatile memory) & RS 485 communication port (MODBUS
RTU protocol) with required software.
124 Remote Control Panel Board for motor
DOL / Star Delta starter suitable for local & remote pump control application consisting of
MPCB, overload relay and contactors as per Type II coordination including digital
voltmeter, analogue ammeter with selector switch, run hour meter, required protective
relays & control accessories. ON/OFF and emergancy stop.
near pump use for remote control ON/OFF and emergancy stop. No. 3.00 6,924.00
125 LV POWER CONTROL CENTER (PCC)
Supply, installation, testing and commissioning LV Distribution Board (LVDB) totally
enclosed, dust & vermin proof, indoor type, fabricated from CRCA sheet steel with
minimum thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load
bearing members / doors & 1.6 mm for internal partitions, minimum degree of protection -
IP 52 as per IS: 2147, suitable for operation on 3-Phase, 4 Wire, 415 V, 50 Hz, Neutral
effectively grounded, with instrumentation compartments accomodating meters, aux /
protective relays, LED type indicating lamps & control MCBs as per IS: 13947, current &
voltage transformers as per IS: 2705, air insulated electrolitic grade Aluminum / Copper
bus bar for three phase & neutral system, GI earth bus for entire length, power / control
wiring using 1100 V grade, FRLS insulated copper conductor wires conforming to IS: 694 &
8130, equipment fittings, horizontally running busbar compartment height of minimum
300 mm, incoming & ougoing cable connections for 1100 V grade, Aluminium / Copper
conductor XLPE / PVC insulated & PVC sheathed armoured cable. LVDB shall have required
incomming / bus coupler / outgoing modules of following type & ratings.
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
Above 80 A, upto & including 250 A, 3 & 4 Pole, Air Break Fixed MCCB conforms to IS / IEC
60947-2 with trip free mechanism, current limiting type with Thermal-Magnetic /
Microprocessor release (O / C, S / C & E / F) with adjustable settings & having minimum
2NO+2NC potential free auxiliary contacts with all necessary Electro-Mechanical
protections & interlocks etc. MCCB module, when used as Incommer / Bus Coupler, shall
have enclosure dimensions- 1800(H) x 600(W) x 600 (D) & following technical features:
4 Pole, MCCB with Breaking Capacity of Icu=50 KA at 415V (Ics =100% of Icu),
Microprocessor release
126 Above 16 A, upto & including 80 A, 3 & 4 Pole, Air Break Fixed MCCB conforms to IS/ IEC
60947-2 with trip free mechanism, current limiting type with Thermal Magnetic /
Microprocessor release (O / C, S / C & E / F) with adjustable settings & having minimum
2NO+2NCpotential free auxiliary contacts with all necessary Electro-Mechanical
protections & interlocks etc. MCCB module, when used as Outgoing(s), shall have
enclosure dimensions- 300(H) x 500(W) x 600 (D) & following technical features:
4 Pole, MCCB with Breaking Capacity of Icu=50 KA at 415V (Ics =100% of Icu),
Microprocessor release Nos. 4.00 35,352.00
127 LV APFC PANEL
Supply, installaton, testing & commissioning LV APFC panel consisting of required
capacitor banks for continuous duty to improve P.F. 0.85 to 0.99 in required steps
enclosed in dust & vermin proof compartment, indoor type, fabricated from CRCA sheet
steel with minimum thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for
load bearing members / doors & 1.6 mm for internal partitions, minimum degree of
protection - IP 42, busbar chamber, required size of Al bus bar / terminals, minimum
stage APFC relay, metering, indicating lamps, push buttons complete as per IS: 16636-2017
with latest ammendment & detailed technical specification and data sheet as under.
Up to 50 KVAR capacity: APFC panel consisting following items.
a) 125 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-
125 A range analogue ammeter of 96 x 96 mm size
with selector switch
c) 3 nos. 125 / 5A, 10 VA CL-1.0 cast resin type current transformer d) Suitable rating
MCCB / MCB &Contactors for each capacitor bank
e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB / non toxic
oil, internally delta connected with built in internal
fuses complete with discharge resistances & terminal cover) of approoved make in
required steps with well suited detuned reactor is placed in
series with each capacitor step. (e.g. 50 KVAR capacity will be provided in steps of 2 nos x
KVAR, 2 nos x 7.5KVAR & 2 nos x12.5 KVAR). f)
Enclosure dimensions: 1600 (H) x 1150 (W) x 600 (D)
As per above specification No. 1.00 1,38,383.00
128 PVC insulated round submersible cable as per detailed technical specifications conforming
to IS 694, IEC 60227 /
129 Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2
sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing
cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site
requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of following sizes:
f) 3.5 core x 120 Sqmm
130 Cable Terminals (Lugs)
Providing & fitting crimping type Cable Terminals (Lugs) conforming to IS of following
types and sizes
Aluminium Tubular Terminals (Long Barrel) (in Sq. mm.)
131 Copper Tubular Terminals (Long Barrel) (in Sq. mm.)
132 Providing & fitting heavy duty brass cable glands (nickel-plated) with washers & rubber
ring conforming to IS, suitable for 3, 3½ & 4 core cables of following type & sizes:
Double Compression Brass Cable Glands
134 Supplying rubber matting of following thickness as per IS:15652/IEC
135 Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. NO. 2.00 212.00
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
136 Providing and erecting metallic vitrified danger notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. NO. 4.00 69.00
137 Providing and erecting metallic vitrified danger notice board as per language suggested by
engineer incharge for HIGH VOLTAGE installation to be erected as per IS.-2551. NO. 4.00 81.00
138 Supplying & erecting ABC powder type 'Ceasefire' type Fire extinguisher as per IS 13849 or
6 Kg capacity with necessary clamp for erection on wall NO. 4.00 5,040.00
139 Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with
necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall
[B] For 5.5 / 6.5 KG Capacity NO. 2.00 8,586.00
140 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the
fault all over the run and back filling the same and making the surface as normal ground.
141 Covering of cable with second class bricks or cement tiles laid cover the cable crosswise &
also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks
per meter) Mtr. 200.00 139.00
142 Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of cable. below ground / road
surface for enclosing cable
(A)50 mm outer dia Mtr. 250.00 62.00
143 (C))90 mm outer dia Mtr. 200.00 95.00
144 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as
145 Supply & laying GI perforated type cable trays with returned edge / flange, fabricated from
2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly hot dipped galvanized after
fabrication as per IS 2629-1989 / IS 4759-1984 including accessories such as coupler
plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware
etc, erected on existing support as per specification and instruction of Engineer-in-charge.
c) 300(W) x 35(H) x 2.0 mm Thick
146 Supply, installation, testing & commissioning single girder type fully electrically operated
EOT crane with electrically operated hoist, class II duty, geared travelling trolley with
seven meter lift complete with long travel rail track (40 mm sq. bar), moving or cross
girder, all three motions electrically operated by suitable rating motor IP 54, control panel
& down pendant control block, brake, safety device, cables form motor to starter panel &
other required accessories & tested as per IS Specifications.
capacity 2 Ton, Span 6m -9m, Long travel 12mtr, Lift 6m -10m set 1.00 476250.00
147 Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T.
OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. Kg. 50.00 77.00
148 Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of
12mm with constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications with chamber and heavy duty
cover.(approved make OEM has to submit test certificate) & having back filling compound
of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted.
(b)For Electrical installation up to 11 KV in normal soil.
Length of Pipe : 2.00 mtrs
Back filling Compound :1 no. Bag of 25 Kg.
149 Supplying & erecting single phase approved make industrial exhaust fan suitable for
medium duty ring mounted low noise operation suitable for medium duty having
following dia size and maximum speed in RPM
[D] 450 mm dia 900 RPM cat III Ea. 2.00 3,306.00
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
150 Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq.
mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multi strand copper
wires upto max length of 10 mt, in below type of pipe erected with 6A Tissino Type ISI
marked flush type switch / bell push and accessories erected on Metal / PVC/Wooden
Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling
complete Pt. 15.00 368.55
151 Point wiring for independent PLUG with following size mains earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires
upto 10 mt length, in following below of pipe erected complete with ISI marked 3 / 5 Pin
socket and tissino type switch erected with earth continuity connection erected on Metal
/ PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet.
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
[B] 6/16A Plug and 16 amp switch with 2-2.5 sq. mm Cu. Mains from mcb d b boards.
(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling
152 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole
should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by manufacturer considering site
(D) 6 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm long J-Bolt.Approx Pole
weight 59 kg Ea. 18.00 8,111.00
153 Providing and erecting street light pole bracket comprising main B Class GI pipe of
cm/require outside dia. complete with suitable B Class G.I sleeve tubing of approx.
45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient
fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per
site condition & suitable welded stiffener reducer and nipple with check nut complete
painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms.
[A] Single Arm Bracket 1 Mtr Ea. 18.00 608.00
154 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. galvanised
iron pipe with coupling and buch buried in specially prepared earth pit complete with
necessary 8 SWG earth wire. Ea. 18.00 365.00
155 For using salt and charcoal / coke as required for pipe type earthing. Ea. 18.00 170.00
156 Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2
sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing
cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site
requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes:
4 Core x 6.0 Sqmm
157 Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with
Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body
and blade sets having ornamental design shanks , canopy erected with earthing. [ Make
shall be approved by Engineer in Charge] Ea. 2.00 2,289.00
158 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod
erected duly painted for fan complete with proper insulation without leakage and
earthing. Ea. 2.00 107.00
159 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with Making
the site as original. Ea. 2.00 43.00
160 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up
to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling with necessary finishing. Ea. 2.00 107.00
161 Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt & Nuts
erected with necessary hook of 10 mm M.S. Round Bar. Ea. 2.00 98.00
162 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box. Ea. 2.00 18.00
Bhavnagar Municipal Corporation
Raw Water G.S.R In Western Area Schedule B
Sr. SOR Rate in Amount
Description Unit Quantity
163 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor
more than 0.9, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet CAT III
164 Supplying and erecting LED street light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage protection.
(iii) Above 60 to 90 watts cat-III Ea. 20.00 5917.00
165 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI
marked copper wires of following size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed Mtr. 300.00 46.00
166 (k) 4.00Sq.mm 4 core round PVC sheathed Mtr. 150.00 175.00
167 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate
on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark Ea. 24.00 111.00
168 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having characteristic of quick action &
tripping with all advance feature & do not incorporate any electronic component for
following Max. rating erected as directed.
(ii) 40Amps. FP CAT III Ea. 2.00 2,611.00
169 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
(b)40 Amp. Cat III
170 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
(B) 40 Amp. CAT III Ea. 3.00 327.00
171 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be
used of same company of MCB to be used) suitable for
(b) sheet steel double door (IP-43)
172 Supplying & erecting approved make IP 55 grade Company fabricated Timer Panel of
following capacity for switch On-Off street lights on time scheduling basis made from 16G
CRCA sheet duly epoxy power painted inside and outside with hinged doors and locking
arrangement consisting of suitable size of 4 Pole MCB and 4 pole contactor (cat-III)with
analog time switch, auto manual switch of same make and suitable input and output
Bakelite terminals and with door earthing approved by Engineer in charge.
173 Operation & Maintenance of electro-mechanical components from end to end (Source to
user) service for 1st year.
174 Operation & Maintenance of electro-mechanical components from end to end (Source to
user) service for 2nd year.
Total Amount in Rs.
Total Amount in Rs.
Bhavnagar Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01. Vol-I Technical Bid (PQ).pdf
02 Vol-IB Generel and Special Conditions of Contract.pdf
03 Vol II Itemwise Technical Specification.pdf
04. Vol III_Price Bid.pdf
Schedule B.pdf
3. CC ROAD.pdf
1. LAYOUT RAW WATER UGSR.pdf
1.1 GAD RAW WATER UGSR.pdf
BMC Vendor list-2023.pdf
vendor list - 30.03.2026.pdf
Download all tender documents and submit your bid