Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.2 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Lowest | |
| 2 | L2₹67.8 L+₹3.4 L (5.28%)Rejected-AOC 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹68.4 L+₹4.0 L (6.20%)Rejected-AOC 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹68.6 L+₹4.2 L (6.50%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC Not Lowest | |
| 5 | Rejected-Technical 21 NEAR LAL KOTHI CHANDER NAGAR SAHARANPUR UP 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | - | Rejected-Technical Not fulfilling the criteria of Class C |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
20 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
CERTAIN REPAIR TO BUILDINGS AT 614 EME REGT UNDER GE CLEMENT TOWN DEHRADUN
2022_MES_550304_1
85378/CLT/E8
Open Tender
Civil Works
Item Rate
270 days
GE Clement Town
Class C cat a i
8 documents required · 8 mandatory
₹1,000
GE Clement Town
₹1.1 L
Yes
12 Nov 2022
6 Sept 2022
27 Oct 2022
6 Sept 2022
20 Oct 2022
8 Oct 2022
6 Sept 2022 - 14 Sept 2022
Amount
Dismantling asbestos cement (corrugated, semicorrugated or plain etc) sheets in roof coverings complete all as specified and directed
Dismantling plain or corrugated steel sheeting any gauge and any thickness as in roof covering complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, ridge etc fixed with self tapping screws complete all as specified and directed
S&F 1.0mm thick plain galvanised iron sheets using grade of zinc coating 120 inclusive of both sides in ridges, hips, valley gutters, drip and straight flashings etc, fixed in any pattern complete all as specified and directed
Fixing only retrived asbestus cement corrugated or semicorrugated sheets as in roof covering, walls etc fixed to steel/ timber purlines rafters etc complete all as specified and directed.
Demolition of PCC any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC (1:2:4) type B1, using 20 mm graded stone agreegate, as in roof kerb or mud stop rounded or chamfered on edges complete all as spd
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified and directed
Dismantling of timber as in scantling 40 sqcm and over in section in any position unframed work complete all as specified and directed
Description same all as per item No-10 above, but as in fillets rails posts rafter etc under 40 Sqcm in section in any position unframed work complete all as specified and directed.
M&L for GI snap grid framework including 4mm thick E-boards for false ceiling (grid size 605mm x 605mm ) including necessary notching and preparing holes and hangers 2mm dia GI adjusting level fixed to structural members. Galvanised steel section of exposes T section grid with exposed flange faces duly powder coated white/ivory colour. The suspension system consisting of perimeter wall angle of size 20x20x0.45mm of GS sheet to secured on wall/partition face with the help of rawl plug screws @450mm c/c. Universal T shaped main runner with single rotatary stiching of size 35x24mm made from 0.33mm thick GS sheet of length 3.60m to be spaced @1200mm c/c. Cross T shaped runner of size 25x24mm with double thick GS sheet 0.25mm thick spaced @ 600mm c/c. To form 600x600mm size module, intermediate T shaped cross runner of size 25x24mm made from 0.25mm thick GS sheet of length 600mm is placed inside the module of size 1200x600mm including suspension of the ceiling frame from structural members with 2mm thick GI wire and level adjusters all cut out etc to the required line and shape as per manufacturer recommendations complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed
M&L for brick work with subclass ‘B’ bricks, half brick thick wall, straight or curved on plan to any radius built in CM (1:4) complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for 15mm thick plaster in CM (1:6) on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed
M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed
M&L for 40mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) laid in alternate panels using glass dividing stripps, as in flooring including finishing top surfaces even and smooth without using extra cement complete all as specified and directed. Note : Glass dividing stripps shall be measured and paid separately.
S&F 3mm thick and 38mm wide glass dividing strips as in floors inserted in position, conform to design complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2, Using 40mm graded stone aggregate, as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete including filling the joints with mastic compound all as specified and directed.
M&L for 30mm thick PCC (1:2:4 ) type B1, using 20mm graded stone aggregate, as in sub base of floor finishing even and fair complete all as specified and directed
M&L for Non skid coloured ceramic tiles 8-9mm thick grade-4 (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of CM (1:4) complete all as specified and directed
M&L for Non skid coloured ceramic tiles 8 to 9 mm thick grade-4 (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering or bedding layer of CM (1:3) complete all as specified and directed
M&L for coloured glazed ceramic tiles in vertical surfaces 300x450x 7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of CM (1:3) complete all as specified and directed
M&L for Non skid coloured ceramic tiles 7 to 8mm thick grade-4 (square/ rectangular) area of each tiles exc 0.11 Sqm but n. exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of CM (1:4) complete all as specified and directed
M&L for 75mm thick PCC (1:4:8) type D2, using 40mm graded stone aggregate, as in sub base of path, finish the top surfaces even and rough to receive top layer complete all as specified and directed
M&L for white marble 18 to 20mm thick (table rubbed and polished) in floor, steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete complete all as specified
M&L for machine cut Kota stone slab 10-12 mm thick as in skirting/dado, pillars, window cills and the like, laid over and including 10mm thick rendering in cement mortar (1:4), set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing and polishing to achieve mirror finish complete all as specified and directed
M&L for rubber moulded coloured glossy finish cement concrete chequered tiles of size 30cm X 30cm X 20mm thick jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in floor over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed
M&L for cutting and grinding to existing kota stone flooring incl rubbing polishing to achieve mirror finish complete all as specified and directed
M&L for PCC (1:2:4) type B0, using 12.5mm graded stone aggregate, as in coping including necessary form work complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of interior acrylic emulsion including a coat of primer of approved tint over a coat of wall care putty to make the surface smooth complete all as specified and directed
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over a layer of wall care putty to make the surface smooth using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equivalent in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of old decorated surface of exterior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equivalent in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for PCC (1:3:6) type C1, using 20mm graded stone aggregate, as in surface channel or drain or benching in manhole complete all as specified and directed.
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but n. exc 2 sqm each complete all as specified and directed.
Description same all as per item No 45 above, but shutter n exc 1 Sqm each complete all as specified and directed.
S&F 30mm thick flush shutter solid core construction with block board core and ply wood face panels, commercial type both sides complete all as specified.
S&F second class timber framed wrought and framed hard-wood in scantlings complete all as specified and directed.
S&F 30mm thick 2nd class hard wood glazed and skelton shutter, open rebated and prepaned to receive glass, gauge etc divided in to square with plain and mitred beads and rebated sash bars any numbers edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified and directed.
S&F galvanised mild steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specifed and directed.
S&F 4mm thick sheet glass ordinary quality n exc 0.5 sqm each pane fixed with wooden beads or with glass putty.complete all as specified and directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm both side prelam PVC sheet and edges will be painted to match with the prelam sheet reinforced with MS square tube in opening incl necessary fixing arrangements as per specification and drawing complete all as specified and directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail and bottom rail on either side as gap insert for top rails, bottom rail, panelling of both side prelam PVC sheet to be fitting in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement in the frame at site as per specification and drawing complete all as specified and directed
S&F 250mm stainless steel sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed
S&F 100mm size stainless steel butt hinges medium weight ISI marked, cold rolled complete all as specified and directed
S&F 75 mm size stainless steel butt hinges medium weight ISI marked, cold rolled complete all as specified and directed
S&F 200mm long stainless steel barrel tower bolts complete all as specified and as directed.
S&F 150mm size stainless steel handles complete all as specified and as directed.
S&F 100 mm size stainless steel handles complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint to new undecorated wooden surfaces over a coat of pink primer including preparation, over 10cm width or girth complete all as specified
S&F in repair of 20mm dia stainless steel drapery rod, fancy type with and including stainless steel knobs and brackets, fixed in any length complete all as specified and directed
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
S&F 15 mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified
S&F 15mm bore gun matel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified.
Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
S&F 20 mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified.
S&F in repair double layer (ISI marked) rotational moulded PVC water storage tank cylinderical, vertical with closed top hoisted and fixed in position tank capacity 500 Ltr with and including PTMT float valve 20mm dia and making connection for inlet and outlet complete all as specified and directed.
S&F 20mm bore gun metel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified and as directed.
S&F in repair vitreous china water closet Orissa pattern of size 580 X440mm white ISI marked with and inluding of cast iron P or S trap and including provn of cement concrete bedding including connections to flushing cistern/pipe and making good disturbed portion to match existing surfaces complete all as specified
S&F in repair vitreous china white wash hand basin OVAL SHAPE of size 550x400mm including CI/MS brackets including cutting for and pinning in brackets but including waste pipe complete all as specified and as directed.
S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action push type with inlet ball valve and float including flush pipe long 32mm dia, ball valve, handle, bracket etc complete all as specified and directed.
S&F in repair 15mm dia brass chromium plated bib tap fancy type with wall flange complete all as specified and as directed.
S&F in repair 15mm dia brass chromium plated pillar tap with long swan neck for 15mm bore dia of pipe complete all as specified and as directed.
S&F in repair 15mm stop valve angle cock fancy type, chromium plated with long high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified and as directed.
S&F in repair 32 mm dia PVC pipe of polyethylene of low or high density (LDPE) for WHB, sink, urinal 750mm long with brass coupling complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed
S&F in repair 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal 110mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed.
S&F PVC (SWR) bend any radius 110mm bore with access door complete all as specified and directed
S&F PVC (SWR) bend any radius 75mm bore with access door complete all as specified and directed
M&L for reinforced precast cement concrete (factory made) (1:2:4) type B1, using 20mm graded stone aggregate, as in landings, cover slabs (for manholes /drain covers etc), shelves and similar articles (shape and size as directed) with plain faces including necessary form work, set in CM 1:4 complete all as specified and directed Note : Reinforcement shall be measured and paid for separately.
S&F mild steel framed work as in manhole cover frames conforming to Fe 410-W (Gde-E-250) quality 'A' complete all as specified and as directed
M&L for 18 to 20 mm thick machine cut, mirror polished kota stone slab as in flooring in full length in single peace without joint, over and incl 15 mm thick cement screed bed in CM (1:3) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing to achiev mirro finish complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, not otherwise described and applying one coat of synthetic enamel paints over 10cm width or girth complete all as specified and as directed.
Dismantling and taking down old unserviceable point wiring of any type (light, fan, socket, power etc) complete with fitting such as switches, sockets, ceiling roses, pendants, lamp holders, light fitting etc including CI/ pressed steel terminals, switch box and making good the disturbed surface of wall/ floor etc to match with the existing surfaces of wall/ floor complete all as specified and directed. Note :- (i) If the contractor fail to make good the disturbed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute, the decision of Accepting Officer will be final and binding. (ii) Old fittings/ fixtures / accessories like switches, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. (iii) Only old unserviceable items will be considered in credit Sch.
Dismantling and taking down unserviceable sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as specified and directed.
Taking down light fittings carefully by un-screwing from ceiling roses, for reuse at site, carrying to the store (To be measured only when found serviceable in all respect for reuse) and refixing the same as directed by Engineer-in-Charge complete all as specified and directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including surface PVC conduit "medium grade" (ISI marked), not less than 20mm dia with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
Descrition same all as per item No 138 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F switch modular single pole, one way 6 Amps, 1 module 240 Volts AC complete all as specified and directed. Make Legrand Cat No- 673401/ Indo Asian Cat No-800000/ Cona cat No-9251.
S&F switch modular, one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make Legrand Cat No- 673411/ Indo Asian Cat No-800002/ Cona cat No-9386.
S&F modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz complete all as specified and directed. Make Legrand Cat No- 673452/ Indo Asian Cat No-800020/ Cona cat No-9316
S&F modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz complete all as specified and directed. Make Legrand Cat No- 673455/ Indo Asian Cat No-800022/ Cona cat No-9416.
S&F step type modular fan regulator 120/280 V , 100watt complete all as specified and directed. Make Legrand Cat No- 673430/ Indo Asian Cat No-800043/ Cona cat No-9381.
S&F ceiling rose 3 terminal/PVC/ Polycarbonate, isolated body complete all as specified and directed.
S&F batton/ angle holder insulated bodywith back plate with and including 09 Watt LED Bulb complete all as specified and directed.
Taking down ceiling fan from existing building again refixing the same ceiling fan connecting up including provision of cable flexible 3 core of suitable size wire from ceiling rose to connect fan complete all as specified and directed.
S&F in repair LED lights fitting mirror type with high out put diffuser 2 feet, 10 watt 220V, AC decorative type with driver, holder nd LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. Make Shakti/ Havells/ Crompton
S&F in repair oval shape bulk head Edge-lit LED fitting comprising with high brightness LED 10 watt, IP-67 protection complete all as specified and directed. Make Crompton, Cat part No- LBHP-10-CDL or equivalent make in philips / Havells / Shakti
S&F in repair LED luminaire 600mm X 600mm, 35/36 watt, 220V AC Recessed type with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F in repair LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K fixing with new bracket of suitable size including 02 Nos MS Clamp made out of FI 40x6 mm, connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and directed. Note: (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No(iv) Connection toluminaire shall be done in suitable PVC connector wwithin the bracket/luminaire end and are inclusive in above.
S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed. Make- legrand / ABB/ Schnider
S&F MCB SP 06 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified and directed. Make- legrand/ ABB/ Schnider
S&F MCB SPN 40 Amp 240 V AC 'B' series 10 KA repturing capacity complete all as specified and directed. Make- legrand/ ABB/ Schnider
S&F sheet metal enclosure double door type for MCBs DB TPN (Triple pole and neutral) 240V AC 4 way with 200 Amps rated busbar complete all as specified and directed. Make- legrand/ Hair/ Schnider
S&F sheet metal enclosure double door type for MCCB DB VTPN 4 Way with 160 Amps, 36KA, 4 Pole MCCB complete all as specified and directed. Make legrand/ ABB/ Schnider.
S&F MCB TPN 63 Amp 240 V AC 10 KA repturing capacity complete all as specified and directed.
S&F sub main wiring two single core 4 Sqmm PVC insulated unsheathed stranded copper conductor cable ( FRLSH) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface on wall along with 4 Sqmm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed.
S&F in repair and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 16 Sqmm 4 core complete all as specified & as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cables, pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed..
M&L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable ( measurement to be taken after punning down consolidated thickness) complete all as specified and as directed .
Supply and laying , un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmX 150mmX40mm with breaking load capacity 200 KG complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI wire 4 mm as earthing lead with nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed.
RAMAPATI ENGINEERING SERVICES
M/S Manmohan Singh Anand
Alankar Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .