Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-Finance | ₹16.4 L | L1 | Accepted-Finance L1 |
| 2 | L2₹19.2 L+₹2.8 L (16.7%)Rejected-Finance LAXMI BAZAER TEHSIL JOGINDERNAGAR DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | ₹19.2 L+₹2.8 L (16.7%) | L2 | Rejected-Finance L2 |
| 3 | L3₹20.2 L+₹3.8 L (22.8%)Rejected-Finance VILLAGE JHANJAIL PO ROPARI TEHSIL SARKAGHAT DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | ₹20.2 L+₹3.8 L (22.8%) | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | M/ Shiv Shakti Traders L2 | Pawan Thakur L3 | M/S THAKUR ELECTRICAL & HARDWARE STORE L1 |
|---|---|---|---|---|---|---|
| 1.00 | LWSS Namhol 2nd Stage
Supply and errection of horizontal spindle horizontal split casing/ multistages centrifugal/reciprocating pumps of standard make such as KSB/Mather platt / Kirlosker/WASP by the Department conforming to BIS-1520-1980 approprite IS/ISO 9001-2000 code ( with upto date ammendments ), read with IS: 9137-1978 or latest to handle clear water having turbidity 50 ppm.with impellers , casing ring &shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity where ever applicable coupled directli through a flexible coupling on a common base plate to Motor of Kirloskar/NGEFl/Crompton/Marathan/Jyoti and suitable for operation on 400 (+)/(-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
Discharge:-13.70 LPS, Total Dynamic Head :-360mtrs
Suction lift:-Positive, Dia of Rising Main :-125mm ,Length of R/Main :-1600mtrs, Pumping Hours:-8 Hours. | 1 | Per Set | 15,25,000 ₹15,25,000 | 15,95,000 ₹15,95,000 | 13,45,000 ₹13,45,000 Lowest |
| 2.00 | Providing and laying copper PVC insulated armoured power Multi core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor & as per directions of Engineer-in-Charge.
Motor side: suitable capacity/ size Min length = 20 mtrs.
Supply side:suitable capacity/ size Min. length =20 mtrs.
Quantity= 1 Job | - | - | - | - | - |
| 3.00 | Supply, Installation, Testing and Commissioning of suitable electrical control Pannel cubical type powder coated with star-Delta-Starter push button type, main incomer MCCB of required capacity, Volt meter 0-500 volts,Ampare meter 100/5 Amp., ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB, power capacitor of required capacity under voltage/over voltage release, over current earth fault relays,suitable to operate all 415 volatage +,- 10% AC supply all equipments shall be of make of L&T/ Havells make complete in all respects including all required accessories of required capacity & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Quantity= 1 Nos. | - | - | - | - | - |
| 4.00 | Supply of Kirloskar/Kilburn/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1.00 Provided with hand wheel/Cast iron Cap.
Quantity= 2 Nos | - | - | - | - | - |
| 5.00 | Supply of Kirloskar/KSB/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^²
Quantity= 1 Nos | - | - | - | - | - |
| 6.00 | Supply of Kirloskar/KSB/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^²
Quantity= 1 Nos | - | - | - | - | - |
| 7.00 | LWSS Silha
Supply and errection of horizontal spindle horizontal split casing/ multistages centrifugal/reciprocating pumps of standard make such as KSB/Mather platt / Kirlosker/WASP by the Department conforming to BIS-1520-1980 approprite IS/ISO 9001-2000 code ( with upto date ammendments ), read with IS: 9137-1978 or latest to handle clear water having turbidity 50 ppm.with impellers , casing ring &shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity where ever applicable coupled directli through a flexible coupling on a common base plate to Motor of Kirloskar/NGEFl/Crompton/Marathan/Jyoti and suitable for operation on 400 (+)/(-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
Discharge:-2.50 LPS per set, Total Dynamic Head :-230mtrs (1 No Working )
Suction lift:-Positive, Dia of Rising Main :-40mm ,Length of R/Main :-576mtrs, Pumping Hours:-8 Hours. | 1 | Per Set | 3,95,000 ₹3,95,000 | 4,25,000 ₹4,25,000 | 3,00,000 ₹3,00,000 Lowest |
| 8.00 | Supply, Installation, Testing and Commissioning of suitable electrical control Pannel cubical type powder coated with star-Delta-Starter push button type, main incomer MCCB of required capacity, Volt meter 0-500 volts,Ampare meter 100/5 Amp., ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB, power capacitor of required capacity under voltage/over voltage release, over current earth fault relays,suitable to operate all 415 volatage +,- 10% AC supply all equipments shall be of make of L&T/ Havells make complete in all respects including all required accessories of required capacity.
Quantity= 1 Nos | - | - | - | - | - |
| 9.00 | Providing and laying copper PVC insulated armoured power Multi core cable (one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
Motor side: suitable capacity/ size Min length = 15 mtrs.
Supply side:suitable capacity/ size Min. length =15 mtrs.
Quantity= 1 Nos | - | - | - | - | - |
Tender Value
₹17.2 L
EMD Value
₹34,400
Closing Date
18 Mar 2026, 3:00 pmClosed
EE JSV Division Jagatkhana
EE JSV Division Jagatkhana
Restoration of rain Damages of various schemes of JSV Sub Division Jukhala in Tehsil Sadar District Bilaspur (H.P.) (SHReplacement of Old Pumping Machinery with allied accessories of LWSS Namhol 2nd stage and LWSS Silha)
2026_HPIPH_131144_1
NIT 17490-17589 Dated 09.03.2026
Open Tender
Repair and Maintenance Works
Item Wise
60 days
Namhol
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
₹34,400
Yes
1 Apr 2026
11 Mar 2026
18 Mar 2026
11 Mar 2026
18 Mar 2026
11 Mar 2026
LWSS Namhol 2nd Stage Supply and errection of horizontal spindle horizontal split casing/ multistages centrifugal/reciprocating pumps of standard make such as KSB/Mather platt / Kirlosker/WASP by the Department conforming to BIS-1520-1980 approprite IS/ISO 9001-2000 code ( with upto date ammendments ), read with IS: 9137-1978 or latest to handle clear water having turbidity 50 ppm.with impellers , casing ring &shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity where ever applicable coupled directli through a flexible coupling on a common base plate to Motor of Kirloskar/NGEFl/Crompton/Marathan/Jyoti and suitable for operation on 400 (+)/(-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- Discharge:-13.70 LPS, Total Dynamic Head :-360mtrs Suction lift:-Positive, Dia of Rising Main :-125mm ,Length of R/Main :-1600mtrs, Pumping Hours:-8 Hours.
Providing and laying copper PVC insulated armoured power Multi core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor & as per directions of Engineer-in-Charge. Motor side: suitable capacity/ size Min length = 20 mtrs. Supply side:suitable capacity/ size Min. length =20 mtrs. Quantity= 1 Job
Supply, Installation, Testing and Commissioning of suitable electrical control Pannel cubical type powder coated with star-Delta-Starter push button type, main incomer MCCB of required capacity, Volt meter 0-500 volts,Ampare meter 100/5 Amp., ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB, power capacitor of required capacity under voltage/over voltage release, over current earth fault relays,suitable to operate all 415 volatage +,- 10% AC supply all equipments shall be of make of L&T/ Havells make complete in all respects including all required accessories of required capacity & any other fittings required as per site conditions & as per directions of Engineer-in-Charge. Quantity= 1 Nos.
Supply of Kirloskar/Kilburn/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1.00 Provided with hand wheel/Cast iron Cap. Quantity= 2 Nos
Supply of Kirloskar/KSB/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² Quantity= 1 Nos
Supply of Kirloskar/KSB/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^² Quantity= 1 Nos
LWSS Silha Supply and errection of horizontal spindle horizontal split casing/ multistages centrifugal/reciprocating pumps of standard make such as KSB/Mather platt / Kirlosker/WASP by the Department conforming to BIS-1520-1980 approprite IS/ISO 9001-2000 code ( with upto date ammendments ), read with IS: 9137-1978 or latest to handle clear water having turbidity 50 ppm.with impellers , casing ring &shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity where ever applicable coupled directli through a flexible coupling on a common base plate to Motor of Kirloskar/NGEFl/Crompton/Marathan/Jyoti and suitable for operation on 400 (+)/(-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- Discharge:-2.50 LPS per set, Total Dynamic Head :-230mtrs (1 No Working ) Suction lift:-Positive, Dia of Rising Main :-40mm ,Length of R/Main :-576mtrs, Pumping Hours:-8 Hours.
Supply, Installation, Testing and Commissioning of suitable electrical control Pannel cubical type powder coated with star-Delta-Starter push button type, main incomer MCCB of required capacity, Volt meter 0-500 volts,Ampare meter 100/5 Amp., ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB, power capacitor of required capacity under voltage/over voltage release, over current earth fault relays,suitable to operate all 415 volatage +,- 10% AC supply all equipments shall be of make of L&T/ Havells make complete in all respects including all required accessories of required capacity. Quantity= 1 Nos
Providing and laying copper PVC insulated armoured power Multi core cable (one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: suitable capacity/ size Min length = 15 mtrs. Supply side:suitable capacity/ size Min. length =15 mtrs. Quantity= 1 Nos
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
PWD8.pdf
Tender Documents • 1.31 MB
PWD6.pdf
Tender Documents • 0.68 MB
BOQ_193894.xls
BOQ • 0.25 MB
TC.pdf
Tender Documents • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .