Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.2 L+₹41,984 (1.63%)Rejected-Finance KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹26.4 L+₹63,571 (2.47%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹26.5 L+₹74,129 (2.88%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹26.6 L+₹83,604 (3.25%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIRS REPLACEMENT OF INTERNAL ELECTRIC FITTINGS FIXTURES INCLUDING SERVICE CONNECTIONS AT VARIOUS OFFRS JCOS AND ORS MARRIED ACCOMMODATIONS AT MASIMPUR MILITARY STATION UNDER GE SILCHAR
2023_MES_597310_1
8785/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MASIMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹50,000
19 Jun 2023
22 May 2023
14 Jun 2023
22 May 2023
12 Jun 2023
6 Jun 2023
29 May 2023 - 2 Jun 2023
Amount
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making god the disturbed surfaces, etc. complete all as specified and as directed
Taking down old unserviceable MCB DBs, enclosures, junction boxes, metal plug sockets, etc. from any location or position and disposing off complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' of size 230x115x 75mm laid in trenches for cable protection complete all as specified and as directed
Supplying, fixing / laying steel water tubing, 50mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing off old damaged tubing complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly with PVC surface terminal boxes complete all as specified and as directed for the following:
One light point controlled by one 5A one way switch
One ceiling fan / exhaust fan point controlled by one 5A one way switch
One 3 pin 5A socket outlet point controlled by one 5A one way switch on independent board
One 3 pin 5A socket outlet point controlled by one 5A one way switch on same board
One bell point controlled by one 5A bell push
M&L for point wiring with 2.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 2.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly with PVC surface terminal boxes for 3 pin 15A socket outlet complete all as specified and as directed
M&L for point wiring with 4sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 4sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly with PVC surface terminal boxes for AC / equipment controlled by one SP / SPN MCB on independent board complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F socket outlet, 2 in 1, 3 pin, 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 5 in 1, 3 pin, 5/16A flush type, ISI marked, 240V complete all as specified and as directed
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed
S&F bell push flush button type, 5A, AC, 230V complete all as specified and as directed
S&F bell buzzer, ding dong type, 230V, single pole complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F in repairs the following items without disturbing existing wiring / fittings including making good the disturbed surfaces of wall/ceiling complete all as specified and as directed
Ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals
Switch piano flush button type, single pole, ISI marked, one way 5A, 240V
Electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked
PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V
Socket outlet, 2 in 1, 3 pin, 5A flush type, ISI marked, 240V
Switch socket combination outlet, 5 in 1, 3 pin, 5/16A flush type, ISI marked, 240V
LED tube rod 20W single side connection
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including non-metallic rigid PVC casing capping 20mm wide, heavy duty, ISI marked surface on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including non-metallic rigid PVC casing capping 25mm wide, heavy duty, ISI marked surface on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed
Notes for item Nos. 34 to 35: (i) 2 runs of 4/6sqmm main cable, 1 run of earth conductors and 1 run of PVC casing capping as per item shall be measured as one length (ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit / casing as per requirement at site
S&F electronic meter tamper proof LCD display with polycarbonate cover, single phase, 230V, 10-60A, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and kWH duly fixed in suitable MS box with locks including taking down old / unserviceable meter any type complete all as specified and as directed
S&F electronic meter tamper proof LCD display with polycarbonate cover, three phase, 415V, 10-60A, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and kWH duly fixed in suitable MS box with locks including taking down old / unserviceable meter any type complete all as specified and as directed
Notes for item Nos. 37 to 38: (i) Old / unserviceable electric meters taken down shall be deposited at MES store including all loading, unloading, carting, etc. and rate quoted shall be deemed to be inclusive of all loading/unloading and carting, etc. as required (ii) Energy meter shall be of makes as stipulated hereinafter (iii) Meters shall be tested for performance as per relevant IS
S&F 1100V grade heavy duty cable PVC insulated aluminium multi-stranded conductor, served with inner sheating of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspension wire, two twin core cable flat or circular including taking down old unserviceable service connections and disposing off complete all as specified and directed of the following sizes:
S&F sheet metal enclosures for 4 way MCB DB, 240V, TPN, double door, powder coated, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for 4 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed
S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed
S&F MCB TPN, 240V, 63A, 4 pole, 10kA, 'B' curve complete all as specified and as directed
S&F MCB SPN, 240V, 40A, 10kA, 'C' curve complete all as specified and as directed
S&F MCB SP, 240V, 5 to 32A, 10kA, 'C' curve complete all as specified and as directed
S&F metal plug socket with MCB SP 20A, 240V enclosure for AC/equipment with neutral and earth point complete all as specified and as directed
S&F wall mounted, compact LED batten type fitting 20W having 30mins backup (working as regular 20W in normal mode and 4W in backup mode), all accessories prewired and connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to fitting including taking down and disposing off old fitting complete all as specified and as directed
S&F building security light, LED luminaire 25W IP 66 with LED lamp, driver, etc. with all accessories pre-wired and connecting with 3 core flexible copper conductor cable drawn through PVC conduit of size 20mm and taking down and disposing off old fitting complete all as specified and as directed
S&F LED bulb 10W, 5 star rated and connecting to lamp holder including taking down and disposing off old bulb / lamp complete all as specified and as directed
S&F heavy duty, metal body with steel blades, legs, ISI marked energy efficient BEE five star rated copper wound exhaust fan, AC, single phase, 230V, 50Hz, 1200RPM, 300mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type and depositing to MES storeyard complete all as specified and as directed
S&F rigid non-mettalic PVC conduit inclusive of boxes with all tees, bend, elbows, etc. of size 25mm complete all as specified and as directed
S&F non-metallic rigid PVC casing capping 25mm wide with accessories complete all as specified and as directed
S&F 3 pin 5A plug top, 230V, 50Hz complete all as specified and as directed
S&F 3 pin 15A plug top, 230V, 50Hz complete all as specified and as directed
S&F PVC rectangular block for mounting switches, sockets, regulators, etc. with 3mm thick plastic laminated sheet cover complete all as specified and directed of following sizes:
100x100mm and 50mm deep
175x100mm and 50mm deep
200x150mm and 50mm deep
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, screened, PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands and taking out old unserviceable cables and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
4 core 16sqmm
4 core 25sqmm
4 core 35sqmm
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 67: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
M/S SANJIB DEB
MS AFTAB LASKAR
m/s builders and suppliers
M/S PIJUSH BHATTACHARJEE
M/S TAPAN KUMAR RAY
P K ROY & SONS
M/S Manik Lal Gupta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .