| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.1 LAccepted-Finance BHAGWATI NAGAR JAMMU | 1 | Accepted-Finance OK | |
| 2 | 2₹10.6 L+₹58,200 (5.79%)Accepted-Finance BYPASS NH NEAR SBI SIDHRA JAMMU | 2 | Accepted-Finance OK | |
| 3 | 3₹10.8 L+₹73,200 (7.28%)Accepted-Finance BHAGWATI NAGAR JAMMU | 3 | Accepted-Finance OK | |
| 4 | 4₹12.2 L+₹2.1 L (20.9%)Accepted-Finance | 4 | Accepted-Finance OK |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
29 Aug 2022, 4:00 pmClosed
Executive Engineer
Executive Engineer PHE Mech. Div. Rajouri
Providing, installation, testing and commissioning of pumping Machinery along with allied electro-Mech equipment at Pumping station Seri Sayal Stage-Ist.
2022_PHE_184694_1
e-NIT PHE/MDR/57 of 2022-23 DATED 10-08-2022
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Rajouri
Please refer Tender documents.
3 documents required · 3 mandatory
₹250
Executive Engineer PHE Mech. Div. Rajouri
₹26,000
Yes
13 Sept 2022
20 Aug 2022
30 Aug 2022
20 Aug 2022
29 Aug 2022
20 Aug 2022
Amount
Providing of Horizontal Centrifugal Pump set 5000 GPH x 180MH coupled with suitable motor at Seri Sayal-stage ist. The pumping Machinery should confirm relevant ISO with all latest amendments. The equipment shall also be accompanied with test certificates and performance curves. Installation by way of Laying of foundation block of size 2mtr x 1 mtr x 1mtr depth inside the pump room by way of excavation of floor and disposal of the excavated earth by using manual labour outside the premises. Cleaning and levelling of excavated trench. Laying of foundation block of RCC for installation of HCP 5000 GPH X 180 MH. The job includes fabrication, welding and laying of steel mesh made from 12mm tor steel placed horizontally, vertically and diagonally at equal distance including form work. Laying of foundation block of RCC in the ratio 1:2:4 (cement, sand and Bajri) and grouting of fabricated foundation bolts. The entire block to be laid in such a way that it can dump all types of mechanical vibration created by dynamic load of the pump. Placing of base frame and levelling. Tightening of base frame by fastening of 6 No. foundation bolts. job includes cost of all types of material such as cement, sand, Bajri, tor steel, foundation bolts, nuts, washers, bolts, carriage of material to site of work on H/L, hire charges of tools and tackles, labour charges of skilled and semi-skilled workers. placing the HC pump set and motor on the base plate tightening of foundation bolts of pump and motor set fixing of coupling pulley on drive end side of pump and motor shaft with the help of cotters and coupling bolts. Proper leveling of pump motor set on the base frame by way of providing steel shims and checking the alignment of pump motor set. Complete job including cost of material such as bolts, nuts, washers, shims coupling bolts and tools and tackles required for execution of the job. Fabrication, fitting and laying of 80 mm dia suction line from service reservoir upto the suction of HC pump set as per site requirement by way of cutting, providing of 80 mm dia flanges and welding by using good quality electrodes so as to get leak proof joints. Providing and fitting of 80 mm dia heavy duty sluice valve with flanges, bends properly welded as per site requirement which is required for stopping the flow of water in suction line for maintenance of pump set. Providing and fixing reducer nipple with flanges on both sides with proper bend to be fitted on the suction side of the HC pump set. Fabrication, fitting and laying of 80 mm dia delivery line for HC pump set. Fabrication and fitting of expander nipple on the delivery side of pump set with flanges on both sides to be connected with delivery side of the pump set with matching holes on one side and 80 mm dia delivery line on the other side. Providing and welding 80mm dia half bends with flanges on both sides as per site requirement. Providing and fixing of 80 mm dia heavy duty sluice valve 1 No. and reflux valve 1 No. with nuts, bolts and gaskets with proper flanges on both sides. The complete welding work on the delivery line shall be done by using superior quality welding electrodes so as to avoid any air gap and to ensure leak proof joints. Making interconnections of delivery line with 80 mm dia existing rising main by fabrication and fitting of nipples, bends, flanges as per site requirement. Complete job including cost of material, hire charges of tools and tackles required at site.
Fabrication and fitting /grouting of angle iron panel board fitted with 12mm thick water proof ply with good quality mica. Providing/fitting of 200Amp 415V HRC type main switch (H/DUTY) -01 no, Providing/fitting of 185mm square aluminium cable -20 mtr-3.5 core for making of connection from LT fuse system to main switch with proper thimbling and insulation. Providing /fitting of 200amp busbar on the panel board. Providing /fitting of suitable capacity starter on the panel board. Providing /fitting of suitable capacity of copper cable for making connection from LT control panel to the motors. Checking continuity of whole electric circuit. Testing and commissioning of electro mechanical works by checking of all electrical connections, tapping and tightening all other connections. Testing the machinery on full load. Complete job
Fabrication/ Manufacturing of 100KVA Voltage Stabilizer at Oil cooled unbalance Type 415Volt at pumping station Seri Sayal stage ist, Complete with Transformer Oil in Copper windings capable of operating on unbalanced Voltage. Installation, testing & commissioning of 100KVA voltage stabilizers by way of carriage/ shifting of stabilizer to site of work on MT and HL. P/F of Aluminium cable 185mm sq unarmoured-20mtr appox of standard ISI make(as per site condition) for making connections from main switch to Voltage stabilizer for all the three phases in three leads with neutral & then from stabilizer to buss bar fuse system with proper thimbling duly crimpled by using crimpling tool & proper insulation. Filling of transformer oil up to required level after heat treatment/dehydration to make it moisture free. Job includes cost of material and Fitting charges. specification as below Capacity : 100KVA Phase : 03 Make Confirming to relevant ISO With all latest amendments Input voltage : (160-380 ) volt Output voltage : 415 volts +/- 1% Type : Manually operated Correction Rate : 12 to 35 V/sec Regulation : +/- 1% Frequency : 48 to 52 Hz Cooling Method : Oil Cooled Efficiency : 95% High & Low cut off : Installed with standard Capacity By pass change over Switch : Yes MCCB : Heavy Duty Single phase preventer : Yes Material of Construction : The Core should be first quality (CRGO) Silico Steel core, Conducting conductor should be off 99.95% of Electrolytic Copper MS Steel thickness of container 14/16 SWG. Transformer Oil to be used shall be of best quality Conforming of IS 335 with latest amendments. Voltage stabilizer shall be mounted on 02 pairs of H/D MS wheels for making shifting/ fixing easy. Voltmeter/Ampere meter Good quality ISI make of Required Specification, Toggle Switch 03 No for input/output reading of each face Rotary Switches Of suitable Amp range each of 08steps. Painting shall be enameled steel grey / Green Colour.
Testing and commissioning of HC pump motor set with stand by and all other allied electro mechanical works. Checking of all electrical connections, tapping and tightening all other connections. Plugging of leaking joints if any by way of welding, replacement of gaskets and tightening of nuts and bolts. Checking the alignment of pump and motor sets and testing the machinery on full load. Complete job
G S ENGINEERING WORKS
M/S FASTTRACK ENGINEERS
VK Mechanical Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .