Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | ₹13.0 L Quoted ₹13.3 L | L1 | Accepted-AOC BEING LOWEST AND REASONABLE |
| 2 | L2₹15.2 L+₹1.9 L (13.9%)Rejected-Finance 21 KISHORE BHAWAN MALVIYA NAGAR AIR FORCE JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹15.2 L+₹1.9 L (13.9%) | L2 | Rejected-Finance BEING NOT LOWEST |
| 3 | L3₹15.6 L+₹2.3 L (17.2%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | ₹15.6 L+₹2.3 L (17.2%) | L3 | Rejected-Finance BEING NOT LOWEST |
| 4 | L4₹22.5 L+₹9.2 L (69.3%)Rejected-Finance | ₹22.5 L+₹9.2 L (69.3%) | L4 | Rejected-Finance BEING NOT LOWEST |
| 5 | L5₹24.1 L+₹10.8 L (81.2%)Rejected-Finance | ₹24.1 L+₹10.8 L (81.2%) | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹28.5 L
EMD Value
₹57,100
Closing Date
3 Jan 2025, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR Opp Mosam Vibhag Airforce Chauraha , Ratanada Jodhpur (Raj)-342011
REPAIR MAINT OF SECURITY LIGHT/ STREET HIGH MAST LIGHT IN DOMESTIC AREA, SU SITE 1A AND 1B AT AFS JODHPUR
2024_MES_687259_1
89021/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF JODHPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF JODHPUR
₹57,100
Yes
5 Feb 2025
6 Dec 2024
6 Jan 2025
6 Dec 2024
3 Jan 2025
20 Dec 2024
Amount
Supply,fixing in Replacement of automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light .The sensor (nature switch ) along with suitable power contactor,MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof ,termite proof and FF grade SMC junction box (sintex make) confirming to IP 54 suitable for three phase phase of 12KW model -Swadeep -02EC12kW3P of make -Nature switch or equivalent in legrand/siemens.
M&L for taking down of old u/s street light any type as directed.
Supply & Fixing in LED street light 70W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge
Supply & Fixing in LED street light 100W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge
Supply & Fixing in LED flood light 200W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge
Supply & Fixing in LED flood light 150W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge
Supply and fixing 6 sqmm 2 core, LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
S&F in repair PVC cable Junction box for street light including 6 Amp MCB SP with aluminium bus bar TPN for controlling the Street Lights complete with pole mounting type size 300x200x105mm with 02 Nos. MS clamp of MS flat iron with bolts, nuts and washer complete all fixed on poles/walls as directed by Engineer-in-Charge.
S&F in repair GI pipe bracket, made out of 40 mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all fixed on poles/walls as directed by Engineer-in-Charge.
Material & labour for Attending of complaint of existing 12mtr long High Mast light of any type, any wattage & any make , complaints received through telephone or in person and identification of defects , bringing down the system upto a normal heigt be manual/motorized & fixing at the same position after rectify the defect including flexible wire of required size, cleaning of light Fittings for clear reflection of light, as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement). Note : - (i) Contractor shall be provide / depute sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and rectified/replacement of parts (ii) contractor manpower shall attend daily to receive complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes
M&L for repair of mechanism of High mast and rewinding of three phase tower motor 440volt AC if burnt and incl. dismantling from high mast transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.
Attending and fault detection of day to day street / security light (LED ,MH/SODIAM Flood light fittings etc. of any make) complaints received through telephone or in person and Rectification of defects installed on Dispersal & High Mast light poles,Sun Shelter lights,Hanger light,perimeter light, watch tower light bringing down the fittings on grond or in position including cleaning of glass/ acrylic cover for clear reflection of light,jumper fixing,loose connection,GI bracket tightening, Checking the connection of Street light FRP junction Box,light allignment,replacement of flexible wire ,tightening of flood light safety chain in Hangers ,Proper insulation of cannection (VMTL Vehicle, ladder, tools ,LT tape and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.Note : (i)Light fitting,MH CHOKE,MH bulb, ignitor,driver,SPD if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply only. . (ii) contractor shall be provide / deputed sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and reactified the same within 24 hours of receipt of complaints. (iii) contractor manpower should attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes (iv) Contractor will depposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M daily based on assesment of complaints.(v)Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract.as directed by EIC
Supply only electric driver for 50 watt street light as directed
Supply only electric driver 75 watt as directed
Supply only electric driver for 100 watt street light as directed
Supply only electric driver for 150 watt LED light as directed
Supply only surge protection device rated 5kv for LED type fitting as directed
S&F in replacement of 2.5 Sqmm 2 core flexible unarmerd copper cable FRLS pvc sheathed for street light to PVC junction box connection as directed
Material and labour for painting of PCC/RCC poles (single pole structure) upto 2.4 meter height from ground level with cement based paint with strip of 0.6 m height at alternate of blue and white as existing pattern including cross arm channels painting on the top of poles with alluminium paint. including mentioning pole Nos reflector type on each pole complete all as specified and directed by the Engineer-in-Charge.
Material and labour for painting of steel poles (single pole structure) upto complete height as existing on site from ground level with aluminium paint including mentioning pole Nos on each pole complete all as specified and directed by the Engineer-in-Charge.
Trimming/cutting the tree branches/ bushes around the LT over head line and making safe clearance up to 1metre distance from line wire all as directed by Engineer-in-Charge.
GANPATI ENTERPRISES (BID ID -3201291)
VIJAY ENTERPRISES (BID ID -3200206)
BHAKAR RAM AND SONS (BID ID -3205473)
Shree Saaram Engineers (BID ID -3199643)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .