Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC SUMISHA ARCADE MURARI LANE KAITHAMUKKU PETTAH THIRUVANANTHAPURAM KERALA 695024 UDYAM KL 12 0030676 | THIRUVANANTHAPURAM | KERALA | 695024 | ₹13.8 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Reject L2 |
| Sl No | Description | Qty | Unit | Usha Fire Tech L1 | Skylight Innovations L2 |
|---|---|---|---|---|---|
| 1.00CIVIL WORKS | |||||
| 1.00 | 13.52.1
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as
per manufacturer's specifications including appropriate priming coat, preparation of
surface, etc. complete.On steel work | 93 | sqm | 650 ₹60,450 | 600 ₹55,800 |
| 1.00 | 22.23.1
Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels
/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the
same from negative (internal) side with the help of synthetic fiber brush. The material
shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as per
DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work
shall be carried out all complete as per specification and the direction of the
engineerin
charge. The product performance shall carry guarantee for 10 years against any
leakage.For vertical surface two coats @0.70 kg per sqm | 115.42 | sqm | 1,250 ₹1.4 L | 1,080 ₹1.2 L |
| 2.00FIRE HYDRANT SYSTEM WORKS | |||||
| 2.00 | OD31612/2025-2026
Maintenance of existing Fire Pumps Control Panel : Maintenance of existing Fire
Pumps Control Panel for Main Electric driven fire pump, jockey pump & diesel
pump set including replacement of switches if required, checking and repairing of
cable alley, inter-connection with accessories, internal wiring, earth terminals etc.
complete in all respect, suitable for Kerala State Fire and Rescue standard. Painting of
Panel board and checking and maintain the Battery charger for Diesel pump and auto
manual switch are also included. | 1 | Job | 45,000 ₹45,000 | 24,000 ₹24,000 |
| 2.00 | OD31614/2025-2026 SITC of Terrace Pump Control Panel : Supply, installation, testing and commissioning
of Automatic control panel, floor / wall mounting type, fabricated out of 2mm thick
CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof,
powder coated of approved shade after 7 tank treatment process, cable alley, inter
connection with suitable accessories and switches, mounting & internal wiring,
earth terminals, numbering etc. complete in all respect, suitable for Terrace pump set
complete with Kerala State Fire and Rescue Service standards, suitable for operation
on 415V, 3 phase, 50HZ AC supply with enclosure protection class IP42 as required. | 1 | each | 14,850 ₹14,850 | 40,000 ₹40,000 |
| 2.00 | OOD31610/2025-2026
Maintenance of existing Diesel Engine Driven Fire Pump : Maintenance of existing
Diesel Engine Driven Fire Pump, with Coil Winding charge, Pump Shaft maintenance
and board maintenance, including charge for removing of the Pump for repairing and
re-installing to the existing location as required | 1 | Job | 65,500 ₹65,500 | 35,000 ₹35,000 |
| 2.00 | OD31615/2025-2026
Maintenance of existing Main Electric Fire Pump : Maintenance of existing Electric
Driven Main Fire Pump, with Coil Winding charge, Pump Shaft maintenance and
board maintenance, including charge for removing of the Pump for repairing and re
installing to the existing location as required | 1 | Job | 21,500 ₹21,500 | 30,000 ₹30,000 |
| 2.00 | OD31616/2025-2026
Maintenance of existing Jockey Pump : Maintenance of existing Jockey Pump, with
Coil Winding charge, Pump Shaft maintenance and board maintenance, including
charge for removing of the Pump for repairing and re-installing to the existing location
as required | 1 | Job | 14,800 ₹14,800 | 17,200 ₹17,200 |
| 2.01 | OD31617/2025-2026
Maintenance of existing Terrace Pump : Maintenance of existing 5HP Terrace Pump,
with Coil Winding charge, Pump Shaft maintenance and board maintenance, including
charge for removing of the Pump for repairing and reinstalling to the existing location
as required. | 1 | Job | 16,500 ₹16,500 | 14,000 ₹14,000 |
Tender Value
₹17.2 L
EMD Value
₹43,500
Closing Date
26 Dec 2025, 5:00 pmClosed
MANAGING DIRECTOR KERALA POLICE HOUSING AND CONSTR
MANAGING DIRECTOR KERALA POLICE HOUSING AND CONSTRUCTION CORPORATION
Repair and Maintenance Works of Fire Fighting System and Fire Alarm System at IMHANS Kozhikode
2025_KPHCC_822611_1
NIT NO 102/KPHCC/2025-26
Open Tender
Electrical Works
120 days
Kozhikode
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,950
₹43,500
5 Mar 2026
18 Dec 2025
29 Dec 2025
18 Dec 2025
26 Dec 2025
18 Dec 2025
CIVIL WORKS
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
22.23.1 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
FIRE HYDRANT SYSTEM WORKS
OD31612/2025-2026 Maintenance of existing Fire Pumps Control Panel : Maintenance of existing Fire Pumps Control Panel for Main Electric driven fire pump, jockey pump & diesel pump set including replacement of switches if required, checking and repairing of cable alley, inter-connection with accessories, internal wiring, earth terminals etc. complete in all respect, suitable for Kerala State Fire and Rescue standard. Painting of Panel board and checking and maintain the Battery charger for Diesel pump and auto manual switch are also included.
OD31614/2025-2026 SITC of Terrace Pump Control Panel : Supply, installation, testing and commissioning of Automatic control panel, floor / wall mounting type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable accessories and switches, mounting & internal wiring, earth terminals, numbering etc. complete in all respect, suitable for Terrace pump set complete with Kerala State Fire and Rescue Service standards, suitable for operation on 415V, 3 phase, 50HZ AC supply with enclosure protection class IP42 as required.
OOD31610/2025-2026 Maintenance of existing Diesel Engine Driven Fire Pump : Maintenance of existing Diesel Engine Driven Fire Pump, with Coil Winding charge, Pump Shaft maintenance and board maintenance, including charge for removing of the Pump for repairing and re-installing to the existing location as required
OD31615/2025-2026 Maintenance of existing Main Electric Fire Pump : Maintenance of existing Electric Driven Main Fire Pump, with Coil Winding charge, Pump Shaft maintenance and board maintenance, including charge for removing of the Pump for repairing and re installing to the existing location as required
OD31616/2025-2026 Maintenance of existing Jockey Pump : Maintenance of existing Jockey Pump, with Coil Winding charge, Pump Shaft maintenance and board maintenance, including charge for removing of the Pump for repairing and re-installing to the existing location as required
OD31617/2025-2026 Maintenance of existing Terrace Pump : Maintenance of existing 5HP Terrace Pump, with Coil Winding charge, Pump Shaft maintenance and board maintenance, including charge for removing of the Pump for repairing and reinstalling to the existing location as required.
OD31618/2025-2026 Pressure Switch : Supply, installation, testing and commissioning charges of Pressure Switch arrangement for pump room and total system
OD31619/2025-2026 Pressure gauge : Supply, installation, testing and commissioning charges of Pressure gauge arrangement for pump room and total system
OD31620/2025-2026 SITC of 200 mm dia Cast Iron Butterfly Valve : Supply, Installation, Testing and Commissioning of 200 mm dia wafer type lever operated Cast Iron butterfly valves, EPDM gaskets, stainless steel shaft, SGI/SS disc with flanges, nut bolts & necessary accessories. The valve shall be PN16 rated. IS 13095
OD31621/2025-2026 SITC of 150 mm dia Cast Iron Butterfly Valve : Supply, Installation, Testing and Commissioning of 150 mm dia wafer type lever operated Cast Iron butterfly valves, EPDM gaskets, stainless steel shaft, SGI/SS disc with flanges, nut bolts & necessary accessories. The valve shall be PN16 rated. IS 13095
OD31622/2025-2026 SITC of 100 mm dia Cast Iron Butterfly Valve : Supply, Installation, Testing and Commissioning of 100 mm dia wafer type lever operated Cast Iron butterfly valves, EPDM gaskets, stainless steel shaft, SGI/SS disc with flanges, nut bolts & necessary accessories. The valve shall be PN16 rated. IS 13095
OD32213/2025-2026 SITC of 80 mm dia Cast Iron Butterfly Valve : Supply, Installation, Testing and Commissioning of 80 mm dia wafer type lever operated Cast Iron butterfly valves, EPDM gaskets, stainless steel shaft, SGI/SS disc with flanges, nut bolts & necessary accessories. The valve shall be PN16 rated. IS 13095
OD32215/2025-2026 SITC of 150 mm dia Dual Plate Non Return Valve : Supply, Installation, testing and commissioning of Dual Plate type Non Return Valves as per API594 PN16 wafer type, SS Disc with required flanges, nuts, bolts, washers, gaskets etc. complete as required. 150 mm dia
OD32217/2025-2026 SITC of 100 mm dia Dual Plate Non Return Valve : Supply, Installation, testing and commissioning of Dual Plate type Non Return Valves as per API594 PN16 wafer type, SS Disc with required flanges, nuts, bolts, washers, gaskets etc. complete as required. 100 mm dia
OD32219/2025-2026 SITC of 80 mm dia Dual Plate Non Return Valve : Supply, Installation, testing and commissioning of Dual Plate type Non Return Valves as per API594 PN16 wafer type, SS Disc with required flanges, nuts, bolts, washers, gaskets etc., complete as required. 80 mm dia
OD32223/2025-2026 SITC of 150 mm dia Y Strainer : Supply, installation, testing and commissioning of 'Y' Strainers complete with all accessories required for complete installation. 150 mm dia
OD32224/2025-2026 Ball Valve : Supply, Installation, Testing and Commissioning of Ball valves (PN 25) with fittings of screwed end type.20 mm dia
OD32225/2025-2026 SITC of 25 mm dia Ball Valve : Supply, Installation, Testing and Commissioning of Ball valves (PN 25) with fittings of screwed end type. 25 mm dia
OD32235/2025-2026 SITC of 63mm Branch Pipe (Yard) : Supply, installation, testing and commissioning of SS 63mm Short branch pipe with 2.3kg weight nozzle as per IS: 903, ISI Marked as required
OD32236/2025-2026 Hydrant Valve Service : Service and commissioning of Single headed, S.S.304 ISI marked, oblique pattern hydrant landing valve with supply of washer, PVC cap and Chain etc. as required
OD32237/2025-2026 Hose Box (Yard) : Supply and installation of Weather proof indoor hose cabinets fabricated from M.S. sheet with glass door with locking arrangement, suitable to accommodate .2 No 15 M long hose and 1 No branch pipe. Glass will be transparent. The cabinet shall be painted with coat of Approved red paint from outside and white paint from inside including all accessories as required for complete installation.(size shall be such that the above all items can be accommodated). as per industrial standards
OD32239/2025-2026 SITC of 63 mm dia RRL Hose (Yard) : Supply, installation, testing and commissioning of non-percolating, rubber reinforced lined fire hose pipe ISI marked (IS:636) 63 mm dia x 15 m long complete with instantaneous type S.S. 63 mm dia, ISI marked Male & Female couplings (IS:903) bound and riveted to hose pipe including all accessories as required for complete installation. ( C.P Hose Not Allowed)
OD32240/2025-2026 Air Release Valve : Supply, installation, testing and commissioning charges of Air Release as per IS: 5312. 20 mm dia
OD32241/2025-2026 SITC of Pendent type Sprinkler : Supply, installation, testing and commissioning of 15 mm dia. Quartzoid bulb type forged brass Sprinkler head suitable to operate at 68 deg. C (UL/FM approved) as required for complete installation as required. Pendent type
OD32242/2025-2026 Fire Brigade Connection Service : Service, Testing and Commissioning of 4 way Fire brigade Inlet connection as required
OD32244/2025-2026 Hose Reel Drum Service : Service, testing and commissioning of compact type first aid fire hose reel with wall mounting swinging-type drum complying with ISI marked.
FIRE ALARM SYSTEM WORKS
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD32252/2025-2026 SITC of 16 Zone conventional type Fire Alarm Control Panel : Supply, Installation, Testing and Commissioning of 16 Zone Fire Alarm Control Panel conventional type, micro processor based control panel, made of MS powder coated CRCA sheet with audio and visual display & supplied with all standard mounting accessories etc as required
OD32253/2025-2026 Manual Call Point : Supply, Installation, Testing and Commissioning of Manual Call Point break glass type powder coated MS box ,24/12 Volt DC operated, and with necessary attachments.
OD32254/2025-2026 Hooter : Supply, Installation, Testing and Commissioning of Audio alarm hooter (sounder) powder coated MS box, 24/12 Volt DC operated with necessary attachments
OD32255/2025-2026 Smoke detector : Supply, Installation, Testing and Commissioning of CONVENTIONAL SMOKE detectors with all standard accessories like base etc to be installed under or above false ceiling. Smoke detector
OD32256/2025-2026 MCP, Hooter and Smoke Detectors Checking : Service, Testing and checking of Conventional smoke detectors, MCP and Hooter installed under false ceiling as required
OD32257/2025-2026 Fire Alarm Cabling : Supply, Installation, Testing and Commissioning of PVC insulated fire retardant FRLS wire armoured 2Cx1.5 sq.mm with ISI mark.
OD32258/2025-2026 S/F of Signages Board : Supplying Installing of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, luminescent self adhesive vinyl painted foam board, complete with mirror fasteners. FIRE DUCT, EXIT, FIRE EXIT, NO SMOKING etc.
FIRE EXTINGUISHER
OD32285/2025-2026 S/F of ABC type Fire Extinguisher : Supply and Installation of ABC type fire extinguisher of 4 Kgs.IS 4308. Capacity with initial filling in brand new cylinder with powder coated finish, discharge hose, wall mounting bracket etc. complete. The Extinguisher is manufactured strictly as per IS: 15683:2018
OD32286/2025-2026 S/F of 2.5Kg Capacity CO2 fire extinguisher : Supply and Installation of CO2 type fire extinguisher of 2.5Kg Capacity with initial filling in brand new cylinder with powder coated finish, discharge hose, wall mounting bracket etc. complete. The Extinguisher is manufactured strictly as per IS: 15683:2018
OD32324/2025-2026 S/F of 4.5 Kg Capacity CO2 fire extinguisher : Supply and Installation of CO2 type fire extinguisher of 4.5 Kg Capacity with initial filling in brand new cylinder with powder coated finish, discharge hose, wall mounting bracket etc. complete. The Extinguisher is manufactured strictly as per IS: 15683:2018
OD32302/2025-2026 Refilling of ABC type fire extinguisher : Remove and refilling of ABC type fire extinguisher of 4-6 Kgs and re installed the same at the previous location as required
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1378678.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tendernotice_2.pdf
PDF • 0.36 MB
BOQ_1378678.xls
BOQ • 0.26 MB
tenderdocument2023.pdf
Tender Documents • 2.25 MB