Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC 17 1305 ARIAKATTU PALLURUTHY KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹31.4 L+₹1.2 L (3.85%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹33.5 L+₹3.3 L (10.8%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹36.8 L+₹6.6 L (21.7%)Rejected-Finance MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹37.5 L+₹7.2 L (24.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
31 Jan 2023, 6:00 pmClosed
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2023_MES_573483_1
8191_GE_NW
Open Tender
Civil Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,800
Yes
27 Feb 2023
6 Jan 2023
2 Feb 2023
6 Jan 2023
31 Jan 2023
19 Jan 2023
6 Jan 2023 - 24 Jan 2023
Amount
Taking down Copper /aluminium point wiring (light ,fan ,socket ,bell, power point ) complete fitting such as switches ,ceiling roses ,pendants,regulators,sockets ,light fitting any type, building security light removing materials to store for keeping in safe custody for taking credit to match with existing surface complete all as specified and directed.
M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade including PVC casing and capping and connected accessories ISI marked with concealed sunken boxes with modular cover plate , PVC boxes, hylem sheet , including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for one light controlled by one switch complete all as specified and directed.
All as per item No-2 here-in-before but for one fan point controlled by one push button on independent board complete all as specified and directed.
All as per item No-2 here-in-before but for one bell point controlled by one push button on independent board complete all as specified and directed.
All as per item No-2 here-in-before but for 3 pin 5 Amps socket outlet point on independent board complete all as specified and directed.
All as per item No-2 here-in-before but for 3 pin 5 Amps socket outlet point on same board complete all as specified and directed.
All as per item No-2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
M&L for point wiring for one light with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and directed.
All as per item No-8 here-in-before but for one fan point controlled by one push button on independent board complete all as specified and directed.
All as per item No-8 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed.
All as per item No-8 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No-8 here in before but for one 5 pin 5 Amp socket outlet point on the same board complete all as specified and directed.
All as per item No-8 here in before but using with 2.5 Sqmm copper conductor cables multistranded (FRLSH) PVC insulated , unsheathed cable and including 2.5 Sqmm copper conductor cable multistranded(FRLSH) PVC insulated and unsheathed cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
S & F bell push flush type 5 Amps single pole complete all as specified and as directed
S & F electric bell, AC 230 Volt single pole complete all as specified and as directed
S & F switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S & F switch piano flush type single pole one way 15 Amp complete all as specified and as directed .
S & F switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified and as directed.
S & F in socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S & F fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
S & F ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
S&F in repairs , bell push flush type 5 Amps single pole complete all as specified and as directed
S&F in repairs , electric bell, AC 230 Volt single pole complete all as specified and as directed
S&F in repairs , switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S&F in repairs , switch piano flush type single pole one way 15 Amp complete all as specified and as directed .
S&F in repairs , socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F in repairs , socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F in repairs , switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified and as directed.
S&F in repairs , switch socket combination multipurpose 5 & 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F in repairs , fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
S&F in repairs , capacitor for ceiling fans,230 volts, 2.5 MFD including necessary soldering complete all as specified and as directed.
S&F in repairs , capacitor for any type of exhaust fan/pedestal fan/air circulator fan 230 volts AC including necessary soldering of capacity 4 MFD complete all as specified and directed.
S&F in repairs , lamp holder ,PVC /poly carbonate type with back plate suitable for batten fittings , complete all as specified and directed.
S&F in repairs , ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
M&L in repairs sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc complete all as specified and directed. Note:- Five run of cable and one run of PVC casing and capping shall be measured as one unit
All as per item No-35 here-in-before but 2 runs of 4 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing . Note:- Three run of cable and one run of PVC casing and capping shall be measured as one unit
All as per item No-35 here-in-before but 2 runs of 6 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing . Note:- Three run of cable and one run of PVC casing and capping shall be measured as one unit
M&L in repairs sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC conduits and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc complete all as specified and directed. Note:- Five run of cable and one run of PVC conduits shall be measured as one unit
All as per item No-38 here-in-before but 4 runs of 16 sq mm single core FRLSH copper conductor and 1 run of 16 sqmm conductor for earthing . Note:- Five run of cable and one run of PVC conduits shall be measured as one unit
All as per item No-38 here-in-before but 2 runs of 4 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing. Note:- Three run of cable and one run of PVC conduits shall be measured as one unit
All as per item No-38 here-in-before but 2 runs of 6 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing. Note:- Three run of cable and one run of PVC conduits shall be measured as one unit.
S&F in repairs , Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repairs , Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repairs , Sheet Metal Enclosure for MCB DB, TPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repairs , Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repairs , Sheet Metal Enclosure for MCB DB, SPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repairs , Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repairs , MCB TPN 63 Amps,415 Volt complete all as specified and directed.
S&F in repairs , MCB TPN 32 Amps,415 Volt, complete all as specified and directed.
S&F in repairs , MCB SPN 63 Amps,415 Volt, complete all as specified and directed.
S&F in repairs , MCB SP 6 to 32 Amps,415 Volt,complete all as specified and directed.
S&F in repairs , MCB SPN 6 to 32 Amps,415 Volt, complete all as specified and directed.
S&F LED Tube light fitting 20 Watts DAWN PLUS, smart Extruded Aluminium LED Batten (4 ft) with higher efficiency, Microwave sensor to save more energy reduces the light by 70% during non-occupancy complete all as specified and directed.
S&F in repairs LED glass T8 tube 20 watt, 220 volt ,50 Hz, LED tube rod, double side connection, inbuilt driver , complete all as specified and directed.
S&F in repairs LED light fitting 20 W, high performance batten , 220 volt ,50 Hz,6000 k surface mounted high quality extruded polycarbonate ,environmental friendly ,energy efficient , with all connecting accessories ,with suitable connection complete all as specified.
S&F in repairs LED light fitting 10 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified and directed.
S&F in repairs ceiling light driver up to 5 Watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs ceiling light driver 10 Watt with all accessories and connection to the electric circuit. complete all as specified and directed.
S&F in repairs ceiling light driver 20 Watt with all accessories and connection to the electric circuit. complete all as specified and directed.
S&F in repairs 15 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hz ,min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs 12 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hz ,min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs 15 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hz ,min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs 12 Watt recessed round down lighter with high luminous LED for indoor application, 230 volts ,50 Hz ,min 100 lm /watt with all accessories and connection to the electric circuit. Complete all as specified and directed.
S&F in repairs 12 Watt surface mounted round down lighter with high luminous LED for indoor application,230 volts ,50 Hz ,min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs dimmable cob light 7 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified and directed.
S&F in repairs dimmable cob light 12 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified and directed.
S&F in repairs Ceiling light in Dome series 18 watt round 18 watt 50 hz,230 volts with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs indoor wall mounted light 12 watt ,140 volt to 265 volts,IP-20 ,50 Hz ,aluminium housing with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs mirror light 18 watt 50 hz,230 volts with all accessories and connection to the electric circuit. Complete all as specified and directed.
S&F in repairs mirror light 12 watt 50 hz,230 volts with all accessories and connection to the electric circuit. Complete all as specified and directed.
S&F in repairs Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F in repairs Down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 2' long, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
All as per item No.72 above but 3' long
All as per item No.72 above but 5' long
S& F in repairs copper conductor multistranded cable flexible 03 core PVC insulated of size 40/0.076 at site/MES store yard complete all as specified and directed.
S&F in repairs Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F in repairs Rubber reel insulator, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S& F in repairs hanging hook for ceiling fan with nuts bolts and washer min thickness 5 mm complete all as specified and directed.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
All as per item No-79 above but exhaust fan of 450/300/250 mm sweep complete all as specified and directed.
All as per item No-79 above but wall mounted fan of 400 /450 mm sweep complete all as specified and directed.
All as per item No-79 above but pedestal fans 600 /400 mm sweep complete all as specified and directed.
All as per item No-79 above but industrial air circulator fans of any sizes complete all as specified and directed.
M & L in repairs Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 cm c/c , 20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
M&L in repairs earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
S&F in repairs Modular Bell push 6A, 1module, complete all as specified.
S&F in repairs Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed.
S&F in repairs switch modular 6 Amps 240 Volts one way switch complete all as specified and directed.
S&F in repairs Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified.
S&F in repairs Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type complete all as specified and directed.
S&F in repairs Switch modular type AC 240 volts 16 Amps one way complete all as specified and directed.
S&F in repairs sunken box with Modular white cover plate 2 module with removing old type sunken boxes /wooden board and match with existing surfaces complete all as specified and directed.
S&F in repairs sunken box with Modular white cover plate 3 module with removing old type sunken boxes /wooden board and match with existing surfaces ,complete all as specified and directed.
S&F in repairs sunken box with Modular white cover plate 4 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified and directed.
S&F in repairs sunken box with Modular white cover plate 6 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified and directed.
S&F in repairs SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed.
S&F in repairs triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed.
S&F in repairs triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 32 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed.
S&F in repairs triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 63 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed.
S&F in repairs XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sq.mm 2 core including taking down old unserviceable cable complete all as specified and directed.
S&F in repairs XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sq.mm 4 core including taking down old unserviceable cable complete all as specified and directed.
S&F in repairs XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sq.mm 4 core including taking down old unserviceable cable complete all as specified and directed.
S&F in repairs circular high bay LED light 80 Watt ,240 volt , min lumens 110 Lm/w ,IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.
S&F in repairs LED circular Flood Light 30 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed.
S&F in repairs LED Flood Light 50 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed.
S&F in repairs LED building security light 45 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed.
S&F in repairs LED building security light 60 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed.
S&F in repairs energy efficient ceiling fan of 1200mm sweep (5 star rated) 230 Volt, 50 Hz including all electrical connection and taking down old one and deposited with MES store yard complete all as specified and directed
S&F in repairs PVC body exhaust fan motor suitable for 250/300 mm of any make as per site requirement complete all as specified and directed.
S&F in repairs exhaust fan motor suitable for metallic body exhaust fan of any make as per site requirement complete all as specified and directed.
S&F PVC body wall fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed.
S&F 250mm sweep, PVC body exhaust fan heavy duty, single phase 230 volts, complete all as specified and directed. Note : Old fan shall be deposited in MES store yard.
Attending complaint including transportation of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at C And D area at Naval Base during off hours (1700 hrs evening to 0900 Hrs morning ) on all working days complete all as specified and directed. NOTE:- (i) The contractor should display contact number at complaint cell to register users complaint. (ii) The recovery of rupees 400 per complaints will be charged if contractor failed to attend that in stipulated time period . (iii) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. Including in all aspects like labours ,tool, transportation etc.
M&L for checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in distribution boards, MCBs in C & D Area at Naval base complete all as specified and directed. Note - 1. The contractor should prepared a register and enter office name with signature of office in charge and submitted to engineer in charge office. 2. Checking of 7 fans and 2 DBs of any type at a time is shall be considered as one job
M & L for checking of faulty / jumped energy meter (three phase /single phase ) with fixing of new energy meter in series and after one week submitted meter reading report of both energy meter complete all as specified and directed.
M&L in repairs aluminium strip 25 x 3.15 mm with porcelain insulators, saddles and fixing screws etc for roof conductor and down conductor above ground complete all as specified and directed.
M&L in repairs air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws and taking down old ones complete all as specified and directed.
M&L for Checking of earthing resistance and E-N voltage with calibrated earth tester meter and multimeter including recharging of conventional earthing of lightening arrestor of building /workshop/hanger /OTM etc at Naval Base Kochi complete with chemical, maintaining the earth testing record, rectification of earthing related fault also as per user signature and JE E/M verified by Engineer in charge.
M&L in repairs galvanised steel strip 32mmx6mm complete with, protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg. complete all as specified and directed.
M&L in repairs galvanised steel strip 25mmx4mm complete with, protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg. complete all as specified and directed.
M&L in repairs of earthling chamber of any type any size with necessary pack work required with smooth surface duly coloured after repair work and cover of the size of the earth pit complete all as specified and directed.
S&F in repairs 4mm dia galvanised iron or steel wire buried in ground fixed on walls and connected to main earth strip including excavation and earth work ,refilling etc. Complete all as specified and directed.
S&F in repairs for rigid non metallic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends, fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia. ISI Marked complete all as specified and directed.
S&F in repairs recess mounted/surface mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' , complete all as specified and directed.
S&F in repairs SS enclosure suitable for MCCB 100-200 amp complete all as specified and directed.
S&F in repairs MCCBs FP 63 Amps thermal magnetic 25 KA complete all as specified and directed.
S&F in repairs MCCBs FP 100 Amps thermal magnetic 25 KA complete all as specified and directed.
S&F in repairs MCCBs FP 160 Amps thermal magnetic 25 KA complete all as specified and directed.
S&F in repairs MCCBs FP 200 Amps thermal magnetic 25 KA complete all as specified and directed.
S&F in repairs bed side Lamp 3 watt 50 hz,230 volts,3000k with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repairs Suspended LED lighting solution with 52 mm width and 75 mm height 24 watt 230V,50 Hz, including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.
S & F Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 1 x 20 watt with glass & connector suitable for LED tube light with all accessories prewired, product in Al. die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR (No Suggestions) &CCOE(PESO) Nagpur along with ISI marking including testing complete all as specified and directed.
S & F Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 2 x 20 watt with glass & connector suitable for LED tube light with all accessories prewired, product in Al. die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR (No Suggestions) &CCOE(PESO) Nagpur along with ISI marking including testing complete all as specified and directed.
S & F FLP rotary switch single pole 16 Amps and fixing arrangement including taking down of existing FLP switch complete all as specified and directed.
N.O. Antony Contractors
ANIE JOHN CONTRACTORS
Oriental Constructions
K A ANTONY & SONS
ST ANTONY CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .