Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹46.9 L+₹2.9 L (6.65%)Rejected-Finance 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹47.3 L+₹3.3 L (7.53%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹49.0 L+₹5.0 L (11.5%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L4 | Rejected-Finance Being L4 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
PROVISION OF FLAME PROOF FITTING AT ARMOURY AND VARIOUS POL STORAGES AND 02 SEARCH LIGHT WITH CONNECTED ITEMS AND PROVISION OF ELECTRICAL GROUNDING AT VARIOUS PLACES AT CGDHQ-15 OKHA UNDER GE(I) CG PORBANDAR
2023_MES_630779_1
8956/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OKHA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹80,000
Yes
9 Mar 2024
2 Dec 2023
13 Jan 2024
2 Dec 2023
11 Jan 2024
19 Dec 2023
Amount
SCHEDULE 'A' E/M ITEMS
Material & Labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including rigid Steel conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed surface/ recessed in wall or ceiling etc including 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire, complete all as specified and directed by Engineer-in-Charge. Note:- Cost of Making Good of existing disturbed surface deemed to be included in unit rate. One light point or one fan point with cables 1.5 Sqmm size
Material & Labour for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required grade drawn through and including rigid Steel conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement, complete all as specified and directed by Engineer-in-Charge.
2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro/crompton/Philips
Supply and fixing LED light fitting 100 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED Flood light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro/crompton/Philips
Supply and fixing 610 mm wall mounted fan flame proof, single phase, 230 V, 50 Hz, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with nut bolts, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer-in-Charge. Make: Bajaj/Havells/khaitan/ Crompton
Supply and fixing Exhaust fan flame proof, single phase, 230 V, 50 Hz, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with nut bolts, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. with louvers shutter, of sweep 300m, complete all as specified and directed by Engineer-in-Charge. Make: Bajaj/Havells/khaitan/ Crompton
Supply & Fixing Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Flame proof Proof Multiway Junction Box, Aluminium Die Cast, Alluminum Alloys LM-6, Waterproof, Flameproof, IP 65, Anti Corrosive Epoxy Powder Coated , 415V, 30 A, complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commissioning of 2X150W LED high intensity, long range, weather & dust proof motor operated security search light with highly polished stainless steel reflector cum body, suitable sinks, toughten front glass, retaining ring, MS cradle and passivated bolts, swiveling type & have both vertical and horizontal operational control with help of remote control unit with suitable control cable, suitable for installing on the roof of the watch tower cabin, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing MCB (DB) TPN 4 way double door 415 V made of sheet metal enclosure for MCB's as incomming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Material & Labour for MCB TPN pole 415 volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002 of 40/63 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for MCB SP 240 volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002 of 6/32 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Material and Labour for DWC pipe 50mm OD laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories, complete all as specified and directed by Engineer-in-Charge. Note: (i) Cutting of floor/ road and making good with PCC deemed to be included in item rate Make: Rex/Poly/Geminie
Supply, laying, Jointing and testing XLPE insulated, Extruded PVC outer sheath and inner sheath, galvanised steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade and laid in trenches/pipe / ducts or on pole, complete all as specified and directed by Engineer-in-Charge. and of the following sizes :- (a) 16 sq mm 4 core
Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge. NOTE :(1) The conctrete pit shall be PCC 1:3:6 tye C -1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars with suitable cast iron handle shall be provided (ii) Item includes the cost of 7.5 Metre GI pipe for protection of earth strip (iii) Item includes the cost of 7.5 Metre length earth strip 4mm dia.
Material & Labour for bore Earthing, 150mm bore for earthing with maintenance free chemical earthing using copper electrode of size 19mm dia - 01 No, 3 Metre long, Copper earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg) - 01 set, complete all as specified and directed by Engineer-in-Charge, shall be deemed to be included in the unit rate. Note: (i) IR Value should be less than 1.0 ohm. (ii) Copper earth stip of size 32 x 6 mm including installation 7.5 Mtr (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge. NOTE :(1) The conctrete pit shall be PCC 1:3:6 tye C -1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8mm TMT bars with suitable cast iron handle shall be provided (ii) Item includes the cost of 7.5 Metre GI pipe for protection of earth strip (iii) Item includes the cost of 7.5 Metre length earth 20×3mm copper strip
Earthing complete with copper plate 60cm × 60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge. NOTE :(1) The conctrete pit shall be PCC 1:3:6 tye C -1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars with suitable cast iron handle shall be provided (ii) Item includes the cost of 7.5 Metre GI pipe for protection of earth strip (iii) Item includes the cost of 7.5 Metre length earth 20×3mm copper strip
Material and Labour Copper earth strip of size 20x3 mm as earth continuity conductor or mainearthing lead fixed to wall on batten or recess or chases or buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. as required, complete all as specified and directed by Engineer-in-Charge.
Material and Labour Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 galvanised iron strip, complete all as specified and directed by Engineer-in-Charge.
Taking down old US GI earthing with strip & Wire, complete all as specified and directed by Engineer-in-Charge.
shree chamunda enterprise
JAY BHARAT METAL SUPPLIERS
Harsh Infrastructure
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .