| 1 | L1₹2.4 CrAdmitted-Finance BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹2.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.5 Cr+₹17.6 L (7.47%)Admitted-Finance | ₹2.5 Cr+₹17.6 L (7.47%) | L2 | Admitted-Finance |
| 3 | L3₹2.6 Cr+₹23.7 L (10.1%)Admitted-Finance | ₹2.6 Cr+₹23.7 L (10.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bankers Construction L1 | CUBIX INFRASTRUCTURES L3 | RAJESH N D L2 |
|---|---|---|---|---|---|---|
| 1.00Civil Works | ||||||
| 1.01 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | 145.08 | Cum | 293.24 ₹42,543.26 Lowest | 295 ₹42,798.6 | 294 ₹42,653.52 |
| 1.02 | 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 22.91 | Cum | 7,891.26 ₹1,80,788.77 Lowest | 7,891.8 ₹1,80,801.14 | 7,892.1 ₹1,80,808.01 |
| 1.03 | Providing Steel Liner 10mm thick for curbs and 6+ 1mm for Steining of wells including fabricating and setting out as per detailed drawing. | 51,023.43 | Kg | 170.1 ₹86,79,085.44 Lowest | 196 ₹1,00,00,592.28 | 191.5 ₹97,70,986.85 |
| 1.04 | Providing floating platform of size 12mx7m on pontoon (as per drawing) in steel work riveted or bolted in builtup section etc. trusses and framed work M.S. angle, iron plats, tees etc. straightening, cutting, fabricating and hosting including applying one coat iron primer for pontoon including cost of materials, labour charges, mobilistaion charges, current charges for welding etc. hire for winch, chain, hook etc. and launching in to the river and all other incidential charges including lighting etc. complete for piling in river portion. | 690 | Rm | 1,150 ₹7,93,500 Lowest | 1,162.5 ₹8,02,125 | 1,160 ₹8,00,400 |
| 1.05 | Bored Cast-in-Situ M30 grade R. C. C Pile using batching plant, transit mixer and concrete pump excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m: Pile diameter 500mm. | 690 | Rm | 5,100 ₹35,19,000 Lowest | 5,350 ₹36,91,500 | 5,200 ₹35,88,000 |
| 1.06 | Chipping and removing extra length of R. C. C Piles - demolishing R. C. C works manually/ mechanical means including stacking of steel bars and disposal of unserviceble material with in 50meters lead as per direction of Engineer-in-charge - based on 15.3 of DSR 16. | 4.51 | Cum | 2,946.42 ₹13,299.55 Lowest | 2,947.25 ₹13,303.3 | 2,950 ₹13,315.71 |
| 1.07 | 20.6.2.2 Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile above 50 tonne and upto 100 tonne capacity: Routine test. | 1 | Nos | 35,770.72 ₹35,770.72 | 35,699.45 ₹35,699.45 Lowest | 35,772.15 ₹35,772.15 |
| 1.08 | 5.22.6 SSteel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
Thermo - Mechanically Treated bars of grade Fe-500D or more | 32,931.71 | Kg | 121.31 ₹39,94,945.51 Lowest | 128 ₹42,15,258.64 | 123 ₹40,50,600.1 |
| 1.09 | 5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 225.96 | Sqm | 805.61 ₹1,82,035.64 | 804.3 ₹1,81,739.63 | 802.25 ₹1,81,276.41 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
21 Jun 2022, 5:00 pmClosed
Manager Projects
KEL Kochi
DEVELOPMENT OF RURAL CIRCUIT MALANAD MALABAR CRUISE TOURISM PROJECT PHASE1 UNDER SWADESH DARSHAN SCHEME- Boat Race Gallery, Pattuvam Mangalseri
2022_KEL_494919_1
KRO/ BDC/1148/2022
Open Tender
Civil Works - Others
Item Rate
360 days
KEL Kochi
As per NIT
6 documents required · 6 mandatory
₹8,850
₹1 L
Yes
24 Jun 2022
14 Jun 2022
23 Jun 2022
14 Jun 2022
21 Jun 2022
14 Jun 2022
14 Jun 2022 - 21 Jun 2022
Amount
Civil Works
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing Steel Liner 10mm thick for curbs and 6+ 1mm for Steining of wells including fabricating and setting out as per detailed drawing.
Providing floating platform of size 12mx7m on pontoon (as per drawing) in steel work riveted or bolted in builtup section etc. trusses and framed work M.S. angle, iron plats, tees etc. straightening, cutting, fabricating and hosting including applying one coat iron primer for pontoon including cost of materials, labour charges, mobilistaion charges, current charges for welding etc. hire for winch, chain, hook etc. and launching in to the river and all other incidential charges including lighting etc. complete for piling in river portion.
Bored Cast-in-Situ M30 grade R. C. C Pile using batching plant, transit mixer and concrete pump excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m: Pile diameter 500mm.
Chipping and removing extra length of R. C. C Piles - demolishing R. C. C works manually/ mechanical means including stacking of steel bars and disposal of unserviceble material with in 50meters lead as per direction of Engineer-in-charge - based on 15.3 of DSR 16.
20.6.2.2 Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile above 50 tonne and upto 100 tonne capacity: Routine test.
5.22.6 SSteel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level
5.23 Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
11.20.3 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).
10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
13.46.1 New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm Finishing walls with Acrylic Smooth exterior paint of required shade:
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.7.2 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
13.52.2 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work
Electrical Works
Supply, installastion, testing and commisioning of cubical metering board, dust & vermin proof, front opening type,cable top entry type made of 16g CR sheet steel to accommodate1No. 3-Phase LCD type KWH meter & 3 Nos of 63A, Bakelite cutout fuse unit with HRC fuse & neutral link, 1No. Cubical 63 A TPN SFU with HRC fuse in separate chambers with hinged doors, including sealing provision for KSEB, glass cutout on meter door for meter reading purpose, all necessary internal rigid wiring [mini. 6sqmm] and earthing. The box shall be treated for anti rust/corrosion, painted with 2 coats of enamel spray paint etc. complete as required. [KSEB shall provide the KWH meter] (rate excluding SFU)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel , making connections, etc, as required - 63 A TP&N
supply & fabrication of M.S.Swaged tubular pole with base plate and single ornamental bracket,Pole height -6mts Pole dimension - 114.3 x 3.65 x 3000 mm ; 88.93 x 3.25x1750 mm ; 76.1 x 3.25 x1250 mm. Bracket 48.3 x 3.25 x 2700 mm x 1.Base plate
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling and secured with holding clamps , bolts , nuts,etc.as required
Supply, installation of 20W, 2000LM, color temperature of 5700K solar panel integrated post top light fixture (make: cromption, havells)
Supply ,installation of 4W, 400LM, color temperature of 5700K solar panel integrated bollard light fixture ( make : cromption,havells)
Supply & installation of 1 x 18w Sonora bollard Decorative (Available in Textured grey, textured brown, antique silver& sunflower green colours)
Supply of 4Cx 25 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098
Supply of 4C x 10 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098
Supply of 4C x 6 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required 4C x 25 sq mm AL cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required 4C x 10 sq mm AL cable
Supplying and fixing following way , single pole and neutral , sheet steel , MCB disribution board , 240 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar , interconnections , powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 12 way SPN DB (double door)
Supplying and fixing 40A , double pole, 240 V, Isolator in the existing MCB DB complete with connections , testing and commissioning etc.as required -
Supplying and fixing 25A, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc as required
Supplying and fixing following way , horizontal type three pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar, earth bar , din bar, Interconnections , powder painted including earthing etc. as required (but without MCB / RCCB / Isolator ) 6 way ( 4+18 ) TPN DB (double door)
Supplying and fixing 63A , four pole ,415 V , isolator in the existing MCB DB complete with connections , testing and commissioning etc.as required
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal / coke and salt) as required
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring/ cable as required
Additional conveyance and material charges to the site
EXCLUDING GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of installation, testing and commissioning cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD/Irrigation Dept. specification and direction of Engineer at site.
5.CEMENT: Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
9. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
10.ALUMINIUM WORK: Make: INDAL, JINDAL or eq. in the order of preference and prior sample approval from KEL, Client
11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
11.1 Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
12.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
13. VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
14. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
RAJESH N D
CUBIX INFRASTRUCTURES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .