Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.0 L+₹4.2 L (25.2%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹15.4 L
EMD Value
₹25,000
Closing Date
25 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Executive Officer
Chief Executive Officer, Cyber Park, Park Centre, KSITIL SEZ, Nellikode (P.O), Kozhikode 673016.
SUPPLY, ERECTION, TESTING AND COMMISSIONING OF THE KITCHEN VENTILATION SYSTEMS AND ASSOCIATED WORKS AT SAHYA BUILDING, CYBERPARK, KOZHIKODE
2023_CP_554434_1
CP/ITB/MEP/PROJECTS/2023/02
Open Tender
Electrical Works
Item Rate
50 days
Government Cyberpark
Bidder must have experience of minimum 5 years and previous experience in similar works
3 documents required · 3 mandatory
₹2,950
Yes
₹25,000
Yes
Government Cyberpark, Kozhikode
10 Apr 2023
2 Feb 2023
27 Feb 2023
2 Feb 2023
25 Feb 2023
6 Feb 2023
2 Feb 2023 - 21 Feb 2023
22 Feb 2023
Amount
CIVIL WORKS
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge: In lime mortar
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-Inchargecomplete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2kg cement per sqm of surface area mixed with specified proportion of approved polymer
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
16.12.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.16.12.2.1 : Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.16.12.2.2 : Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.12.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.16.12.2.3 : Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.00 mm thick
Supply and installation of powder coated extruded aluminum extract louvers for kitchen extract duct . These louvers shall also be provided with bird mesh/ Insect screen 1700X900
Supply and installation of powder coated extruded aluminum fresh air louver with sand trap arrangements for kitchen make-up air supply 1750X600
Supply , Installation, Testing & Commissioning of Volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised steel frame and blades of 1.55 mm galavanised sheet steel. 500X400
Supply , Installation, Testing & Commissioning of Volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised steel frame and blades of 1.55 mm galavanised sheet steel. 600X300
ELECTRICAL
Supply, installation, testing and commissioning of following breaker with accessories as listed below, confirming to relevant standards & specifications: Remote push button station with illuminated ON & OFF push button, trip indicator and associated accessories in suitable weather proof enclosure
Supply, installation, testing and commissioning of following breaker with accessories as listed below, confirming to relevant standards & specifications 3Pole, 32A, 10kA, MCB in existing DB<br>
Breaker with / with out enclosure.<br>Make: L&T/ Schnieder/ ABB : Supply, installation, testing and commissioning of following breaker with accessories as listed below, confirming to relevant standards & specifications 1 Nos of 4Pole, 40A, MCB isolator+ 4Pole 40A 100mA RCCB with IP-20 enclouser with all accessories
Breaker with / with out enclosure.<br>Make: L&T/ Schnieder/ ABB : Supply, installation, testing and commissioning of following breaker with accessories aslisted below, confirming to relevant standards & specifications 1 Nos 4Pole, 63A,MCCB isolator with IP-65 enclouser with all accessories like ELR, RYB indicator set, etc.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3.5 core 50 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required4 core 16 sq mm with factory made clamp
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 90.16.5.3 3.15 mm (10 SWG)
9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 50 sq. mm (32MM)
9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 16 sq. mm (28mm)
90.16.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required90.16.1.3 3.15 mm copper conductor ( 10 SWG)
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20 mm
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.1.21.2 25 mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 3 core 6 sq mm
3 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 1.14.8 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 amps switch
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.3 15/16 amp switch
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin 5/6 amp socket outlet
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.5 6 pin 15/16 amp socket outlet
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1.27.2 3 Module (100mmX75mm
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1.27.4 6 Module (200mmX75mm)
Supply,Installation,testing and commissioning of wet scrubber with self contined blower evaporative section, filter and pump. The unit will have horizontal single phase 220V, +/- 6%, 50Hz supply monoblock self priming pump assembly to provide recirculated tank water and a pressurized flow via piping system for proper pad and media water distribution. All wet section will include 5 layer 30 micron aluminium wiremesh filter of 50mm thickness including the mounting channels. The filter to be designed at 2.5 m/s. to give 90% efficiency down to 30 micron and complete as per specifications and approved shop drawing. Fan shall be of 12000 cfm capacity at 125mmwc external static pressure & 10HP MOTOR with VFD drive and its controls( for kitchen Exhaust Fan ) with wet scrubber. motor should be suitable for outdoor mountable type. Price shall be inclusive of unloading, shifting to terrace(above VI floor)
Supply & Installation of axial type Ventilation fan comprising of fan section & filter section (pre-filter 10 micron)of following capacity for Fresh air supply system. supply and installation of 9600cfm @ 30 mm of wc external static ductable tube axial exhaust air fan with motor rating of 5.5kw with VFD drive and its control Supply & Installation of Weather proof Make-UP air fan complete with all sections as listed above & detailed in tender drawings
Supply Installation Testing and Commissioning of 240V Panel cooling 4 inch axial fan
Supply, Installation, Testing and Commissioning of UPVC ASTM Schedule 40 Pipes of 25mm Nominal Dia wilth all accessories like bends for water supply joined using solvent cement fitting with metal support at 1m intervals suitable for working pressure.The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 1.6mm thick confirmed to IS 1239 etc.,complete as directed by the employer.(Hitech Supports/ Equivalent);Hot dip galvanized (Fully exposed to weather and wet areas).Rates must also include the application of primer in the Slotted rail as well as Clamps
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore of Make Normex/Leader
Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energisation certificates from Electrical Inspectorate for commissioning of the whole installation from which the supply is availed (Note: The rate must include the approval of existing DB/Panel from which supply to Wet scrubber as well as Fresh Air Fan is taken )and All statutory payments will be reimbursed on production of the original receipts after the completion of the work.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete withG.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia
techmech engineers
Bidder Name
techmech engineers
AMS Electro Consultants and Contractors Private limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .