| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹10.8 L+₹2.9 L (36.3%)Rejected-AOC | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
6 Sept 2021, 6:00 pmClosed
BA Nirmal Kumar EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2021_MES_468720_1
8622
Open Tender
Civil Works
Works
150 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹20,000
Yes
23 Oct 2021
17 Aug 2021
7 Sept 2021
17 Aug 2021
6 Sept 2021
24 Aug 2021
18 Aug 2021 - 23 Aug 2021
Amount
Excavation in trenches nexc 1.5 mtr wide and n exc in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil complete.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm complete.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable complete.
M&L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete
Taking out UNSV LT under ground cable and removing cable from site and Supply, Laying, jointing and testing electric 16 sq mm 4 core under ground LT cable PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches ducts, pipe on walls, poles complete.
Taking out UNSV LT under ground cable and removing cable from site and Supply, Laying, jointing and testing electric 10 sq mm 2 core under ground LT cable PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches ducts, pipe on walls, poles complete.
M&L for 50 mm dia bore GI tubing light grade fixed on wall/pole laid in trenches/under road etc. Complete
M&L for KAPITRODE Earthing with Cast Iron pipe electrode, 75mm bore, 3.15mm wall thickness , 2.9 metres length,with GI pipe & funnel, buried directly and preferably vertically in ground with top edge not less than 2.9 metres below ground level connected with earthing lead of 25 x 5mm dia galvanised iron strip including the following, : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1 of size 450 x 450 x 450mm with Cast iron cover with suitable handle. (c) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead. (d) Requisite quantity of BFC Compound (bentonide powder) and black cotton soil. (e) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost complete.
Taking out cable loop after dismantling cable ends from panels, cutting / removing heated cable ends with burnt lugs and inserting new lugs after cutting opening of fresh cable end including earth work and relaying cable neatly around loop for cable size 70 to 185 Sqmm complete.
Comprehensive maintenance of street light fitting comprising of 70W / 125W / 150W / 250W / 400W HPSV / HPMV / lamp fittings of any make any model fitted on the pole at any height with any type of fixing arrangement by replacing the ignitor, ballasts, capacitor, flexible wire / Al wire two core 2.5 sqmm / 4sqmm, clamps, nuts and bolts and lugs, including if necessary increase or decrease to the height of the fixing arrangement by removing the bent pipe and clamps and refixing it to the proper height and removing all the hanging wires, cables, PVC pipes, old rusted clamps, hanging aluminium wires, hanging grasses etc and tightening of all nuts, bolts, clamps and fixing of the street light at proper direction complete.
(i) Payment shall be make at proportionate rates as arrived from quoted rates.
(ii) In case any light found unserviceable for more than one week for the reasons attributed to the contractor, the panel recovery at the rate of double the quoted rate per week or part there of shall be done through RAR.
The comprehensive maintenance period shall be reckoned from the date of commencement to actual date of completion of whole work which ever is later.
Decision of the accepting officer shall be binding upon the contractor regarding panel recoveries.
S&F in replacement steel tubular swaged cast iron plate base plate, finial plug, bolts, nuts and screws as specified type 410 SP-31 of length 9 mtr including earth work, PCC for foundation, copping all around the pole duly painted with aluminium paint over a red oxide primer as per SSR Part I complete.
Dismantling / taking out old defective cable form street light poles (Junction box to fitting / overhead line to fitting) and S&F aluminium conductor multistranded / solid on poles or passing through steel or PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete of following sizes :-
4 Sqmm two core conductor.
6 Sqmm two core conductor
S&F in replacement bracket with clamp for fixing street light fitting made out of GI pipe light grade including bending to shape of length 1.5 m complete :-
25 mm dia
40 mm dia
S&F in repair post top lantern fitting comprising with LED lamp similar to CAT Part No. LPTO-40-CDL/M, 40 watt of CG complete.
M&L in replacement MCCB 4 pole 100 Amps, 415 volts, 16 KA complete.
M&L in replacement MCCB TPN 63 Amps, 415 volts, 16 KA complete
Supply, fixing, testing and commissioning in replacement LED street light similar to LSTP-72 CDL 72 WATT of CG complete.
S&F in replacement wall security light LED type with 25mm dia GI pipe bend 1.2 mtr and fixing on wall / pole with 25 x 6mm MS clamp, nut & bolt etc. and similar to CAT Part No. LSTS-45-CDL 45watt of CG complete.
S&F in replacement street light box of PVC of Size 20 cm x 20 cm x 15 cm with hinged door inculding locking arrangment with consisting of 01 No MCB 10 Amps, 10 KA capacity (Single phase) including aluminium strip and necessary clamping, Nuts, bolt etc complete
Dismantling of analog timer and S&F Pole mountable (Timer switch for street lights) sensor based, astronomical and nature type timer switch with Nature switch - 02 Nos, power contactor for load switching, MCB, and terminal block with mounting brackets, cable glands, openable door with lock and key and enclosure made of UV stabliszed, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor complete.
M&L for preparation of existing old painted surface of any description such as LT/HT steel tubular electric pole/struts of any height including cross arms bracing clamps etc and apply one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT/HT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint etc. complete.
Trimming of tree branches around 3 meter from over head conductor with necessary tools and ladders complete.
Taking down old unserviceable flood light fitting and M&L LED flood light fitting 150 watt similar to CAT No. LFLN of CG complete.
Taking down old unserviceable flood light fitting and M&L LED flood light fitting 250 watt similar to CAT No. LFLN of CG complete.
M&L for Servicing of Vaccum Circuit Breaker 800 Amp Capacity with replacement of Worn out Parts, Bushings, Tripping Relays, RYB Indicators and greasing of movable parts and Testing on Load complete
CENTAUR ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .