Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹11.4 L+₹1.4 L (14.0%)Rejected-Finance 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹12.7 L+₹2.7 L (26.6%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹12.9 L+₹2.9 L (29.2%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹13.7 L+₹3.7 L (36.5%)Rejected-Finance DOOR NO 25 32 NAGARAPALEM ROAD MADHURAWADA VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
19 Jul 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIR/MAINTENANCE OF SECURITY/ STREET HGIH MAST SOLAR LIGHT SYSTEM AND OTHER CONNECTED WORKS AT NAD BHEEMUNIPATNAM AND INS KARNA VISAKHAPATNAM AND REPAIR/ MAINTENACE OF E/M INSTALLATION AND OTHER MISC ALLIED WORK AT INS KALINGA AND NAD BHEEMUNIATNAM
2022_MES_530166_1
GE (P)/N/K/8924 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹34,000
Yes
11 Aug 2022
10 Jun 2022
21 Jul 2022
10 Jun 2022
19 Jul 2022
24 Jun 2022
Amount
Taking down carefully existing aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification complete all as specified and as directed.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site complete all as specified and as directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
All as per Item no 3 here-in-before but for one fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item no 3 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 3 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item no 3 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed
Fixing only switch flush button single pole one way 5 amp all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be re-used)
Supply and fixing socket combination 2 in 1 3 pin 5 amp flush type universal all as specified and as directed.
Fixing only switch socket outlet 5 amp flush type all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be re-used)
Supply and fixing socket combination 2 in 1 3 pin 5 and 15 amp flush type universal all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
Fixing only ceiling rose surface bakelite three terminals all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be re-used)
Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed.
Fixing only fan regulator any type all as specified and as directed. Note : Material obtained from item No 2 here in before shall be re-used
Supply and fixing indoor luminare decorative batten for wall/ceiling mounting energy efficient saving LED BATTEN LIGHT 18 /20 W 4' (feet) with incl LED Tube T8 Type long incl twin twisted copper conductor flexible wire from ceiling rose to connector with taking down old unserviceable one complete all as specified and as directed.
M & L for LED Tube 18 /20 watt Fixing in existing unserviceable tube light Fitting with taking down old unserviceable tube complete all as specified and as directed
M & L for LED Tube 10 watt Fixing in existing unserviceable tube light Fitting with taking down old unserviceable tube complete all as specified and as directed
S&F on wall security light luminaire for 1x25 w LED with deep drawn housing complete with and including cable for connection from ceiling rose with 1.5 Sqmm PVC insulated stranded copper conductor complete all as specified and as directed.
Supply and fixing LED Strip Light 10 Watt with Suitable Driver of same make Fixing in False ceiling Grooves at Required Site and installed By Expert Electrician and Connect From existing incoming wire, incl taking down old u/s complete all as specified and as directed .
Supply and fixing LED Flood Light 120 W, IP65 suitable for at Existing false Ceiling/ Pole/ wall/ Tower/ Ground with suitable size necessary fitting and fixture(hook/suspended rod of reqired size) existing electric incoming cable including taking down old unservicebale one complete all as specified and as directed.
Supply and fixing LED highbay Light 150 W, IP66 suitable for at Existing false Ceiling /shed with suitable size necessary fitting and fixture (hook/suspended rod of reqired size) existing electric incoming cable, including taking down old unservicebale one complete all as specified and as directed.
Supply and fixing LED lamp 40 Watt in repairs of existing lamp fitting any type and size,incl taking down old u/s, all as specified and as directed .
Supply and fixing lamp holder insulated body suitable for Retrofit lamp incl taking down old u/s, all as specified and as directed.
Supply and fixing sheet metal enclosure for two pin and earth plug and socket complete with one 20 amps MCB, incl taking down old u/s all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as incl taking down old u/s specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar all as incl taking down old u/s specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar all as incl taking down old u/s specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position incl taking down old u/s all as specified and as directed.
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position incl taking down old u/s all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs and supply and fixing new power contactor 3 pole AC control capacity 25 Amp,220-240 coil volt, including the copper wire &copper lugs and testing complete all as directed. (Make : GE Cat no:- CL01A310T or equivalent as approved by GE.)
Material & Labour for taking down the unserviceable contactor & burned out copper wire,lugs and supply and fixing New power contactor 3 pole AC control capacity 25 Amp, 220-240 coil volt, including the copper wire& copper lugs and testing complete all as directed. Make : GE cat no:-CL25A300T or equivalent as approved by GE.
Material & Labour for taking down the unserviceable contactor & burned out copper wire,lugs and supply and fixing New power contactor 3 pole AC control capacity 32 Amp mounting type Din rail , 220-240 coil volt including the copper wire& copper lugs and testing complete all as specified and as directed. Make : ABB cat no: A30-30-10 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable contactor & burned out copper wire,lugs and supply and fixing power contactor 3 pole AC control capacity 25 Amp mounting type Din rail 220-240 coil volt including the copper wire& copper lugsall as specified and as directed, Make :C&S Model No : TC1D2510 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable contactor & burned out copper wire lugs and supply and fixing power contactor 3 pole AC control capacity 30 Amp,MNX12 TYPE, mounting type Din rail all as specified and as directed, Make :L&T MODEL no: CS94108 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable contactor & burned out copper wire,lugs and supply and fixing power contactor 3 pole AC control capacity 32 Amp, MNX32 TYPE, mounting type Din rail all as specified and as directed.
Material & Labour for taking down the unserviceable contactor & burned out copper wire, lugs and supply and fixing auxiliary contract block single phase DC voltage 600 V power contactor 3 pole AC control capacity 25 Amp all as specified and as directed. Make : GE cat no:-BCLP10 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable CONTACT BLOCK and supply and fixing auxiliary contract block single phase DC voltage 600 V power contactor 3 pole AC control capacity 25 Amp. Make : C&S Model no:-TA1-DN 22 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable CONTACT BLOCK and supply and fixing auxiliary contract block single phase DC voltage 600 Vpower contactor 3 pole AC control capacity 25 Amp Make :L&T MODEL no:-MNX-A2 or equivalent as approved by GE.
Material & Labour for taking down the unserviceable Timer and supply and fixing Timer mounting din rail rated voltage 230 V ,IP 50 all as specified and as directed. MAKE :-SELEC CAT N0-800 SD-2-230 or or equivalent as approved by GE.
Material & Labour for taking down the unserviceable relay and supply and fixing relays RT series wide range of AC AND DC COIL VOLTAGE high switching current capability and reliable,long operational , all as specified and as directed
Material & Labour for taking down relays and supply and fixing relays ,range 14 to 23 amps , MN series type MN2 high switching current capability and reliable,long operational , all as specified and as directed.
Material & Labour for taking down relyas and supply and fixing relays ,range 09 to 15 amps MN series type MN2 , high switching current capability and reliable,long operational , all as specified and as directed.
S&F Digital Ammeter, 3 phase, 5 Amps, class 1, AC supply as fixed in repairs , incl taking down old u/s ,complete all as directed.
S&F Digital Voltmeter,3 phase,5 Amps,class 1,AC supply as fixed in repairs complete all as directed.
S&F MPD Power supplier of capacity 5-30 Amps auxilary supply,15 V,AC 230V,50Hz,AC supply as fixed in repairs ,incl taking down old u/s complete all as directed.
Material & Labour for taking down the defective unserviceable solenoid valve coil and supply & fixing of new coil suitable to work in single phase, AC 220 V,50 Hz complete all as directed.
Taking down unserviceable single phase preventer and S&F new single phase preventer,6 wires,230 V complete all as directed.
Supply and fixing modular plate switch flush type, single pole one way 16 Amps 250 volts with taking down old unserviceable one all as specified and as directed.
Supply and fixing modular socket 6 Amps 5 pin. with taking down old unserviceable one all as specified and as directed.all as specified and as directed.
Supply and fixing modular socket 6-16 amps 2/3 pin combined shuttered with taking down old unserviceable one all as specified and as directed.
Supply and fixing modular step fan speed regulator 120 w ,2 module with taking down old unserviceable one all as specified and as directed.
Supply and fixing modular plates white colour suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules.
All as per item No. 58 here-in-before but for 6 modules all as specified and as directed.
All as per item No. 58 here-in-before but for 3 modules all as specified and as directed.
All as per item No. 58 here-in-before but for 2 modules all as specified and as directed.
Comprehensive repair/maintenance electric operating system with gear and 3 phase 415 V for rooling shutter motor Dismantling the electrical connection from system and removing out the Induction Motor and Gear Box for Reconditioning /Overhauling Completely Transporting the Induction Motor capacity1 HP to civil work shop and strip opening the motor and removing out the burnt out winding and cleaning of the stator core and rewinding with suitable size super enameled copper wire with necessary insulations and varnishing becking and replacement of unserviceable ball bearing and assembling back the motor and re -fixing with gear Box and necessary electrical connections and testing and commissioning the rolling shutter all as specified and as directed.
M&L for Earthing complete with 2.5m CI pipe 80 mm dia with flanged ends, centifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slote up to 2 mtrs length buried directly and preferably vertically in ground with top flanged ended 2 mtrs below ground lebel welded/connected with GI strip 25X4 mm dia Galvanised iron or steel wire, connected to Earth electrode to DB for earthing including filling the pit with charcol common salt surrounding the earth pipe includingdrilling 400 mm dia bore in any strata of soil to lower the CI pipe complete
M&L for taking down high pressure SV/MV/MH/FTL/LED street light fittings and flood Light fittings of any wattage/ any height of pole/walls/ any location for repairs or replacement of burnt out the accessories and rectifying the fault etc. complete all as specified and as directed by the Engineer-in-Charge. Note: LED drivers, surge protection and cable etc. shall be measured separately under relevant items of this schedule.
S&F in repair LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 45 Watt complete with driver, lamp bracket with mpact and corrosion resistanat including thermal management in multiple optics all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LSTS-40-CDL-M or equivalent as approved by GE
S&F in repairs, LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 60 Watt complete with driver, lamp bracket with mpact and corrosion resistanat including thermal management in multiple optics all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No.LSTP-60-CDL-M or equivalent as approved by GE
S&F in repair LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 120 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLN-120-CDL/60-M or equivalent as approved by GE
S&F in repair LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 200 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLN-200-CDL/60-M or equivalent as approved by GE
S&F LED flood light 250 W, 230 Volts luminaire with pressure die-cast aluminium housing IP 66 protection, any height and any location including internal prewired with all materials complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLPI-250-CDL/60-M or equivalent as approved by GE
Supply only drivers for LED street lights 25W/35W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply only drivers for LED street lights 45W/60W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply only drivers for LED flood lights 100W/120W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply only drivers for LED flood lights150W/200W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply, laying and testing 3 core round flexible cable 1.5 Sq.mm. PVC insulated, 1100 Volts grade, PVC sheathed with two runs of single core multistranded FLRS copper conductor along with one run of necessary earth continuity conductor of 1.5 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
S&F digital time switches with battery back up 1100 hours with current capacity 16 A programmable every 1min with 1 changeover and total 28 programs complete all as specified and as directed by the Engineer-in-Charge. Make: Indoasian Cat. Part No. TDA43110 or equivalent as approved by GE
S&F in repairs contactor ML-2 of capacity of 32 Amps AC 3 phase heavy duty including taking down old unserviceable contactor complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs contactor ML-3 of capacity of 40 Amps AC 3 phase heavy duty including taking down old unserviceable contactor complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair timelite distribution board 32 Amps, 3 pole, 230 volts digital time switch complete all as specified and directed by Engineer-in-Charge. Make: Indoasian cat No. TL032DB0 or equivalent as approved by GE
M&L for cleaning the swaged steel tubular street light poles of 9/11 meters height including GI pipe of street light fitting and preparation of surfaces by cleaning including scrapping up old corroded paint/dirt/dust/rust carefully and applying two coats of aluminium paint over one coat of metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats of colour washing on PCC coping surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for cleaning the pre-stressed cement concrete street light poles of 9/11 meters height, preparing old plastered or unplastered surfaces and applying two coats of cement based paint over one coat of primer including writing of pole numbers and two coats of colour washing on PCC coping surfaces complete all as specified and as directed by the Engineer-in-Charge.
S&F GI bracket suitable for street light fitting made out of 40mm dia. GI tubing of light grade bent to shape of 1.5m length complete including taking out old one complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying LT underground cable XLPE insulated and sheathed armoured cable 1100 Volts grade of size 4 core 16 Sq.mm. aluminium conductor in trenches/poles and connecting with all accessories including taking out the old unserviceable cable complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m depth and getting out soft/loose soil for laying of under ground cable complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m depth and getting out soft/loose soil for laying of under ground cable complete all as specified and as directed by the Engineer-in-Charge.
Returning/filling including spreading, levelling and well ramming in layers n. exc. 25cm in thick complete all as specified and as directed by the Engineer-in-Charge.
Removal of surplus soil to a distance n. exc. 50m away and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and as directed by the Engineer-in-Charge. Note: Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and lay unreinforced precast concrete cable cover class LV, type 1, flat, size 250mmX150mmX40mm for protection of cable, laying in trenches complete all as specified and directed by the Engr-in-Charge
Supply and lay GI pipe 40mm dia. light grade for cable protection as per site requirement and sealing the pipe both ends with sealing compound complete including taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP-65 protection of size 250x250x150mm with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and as directed by the Engineer-in-Charge. Make: Hansel/Sintex
S&F in repairs, MS clamps suitable for 40mm GI pipe made out of 25x4mm flat iron complete with necessary nuts and bolts complete all as specified and as directed by the Engineer-in-Charge.
S&F rigid non metallic PVC conduit 20mm dia. including all the fittings like Tees, bends, elbows, reducers etc. and fixtures such as couplers, lock nuts, saddles, pipe hooks etc. complete including taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M&L for repairs and maintenance of LED solar lights with charging and topping up distilled water in solar light batteries to maintain necessary specific gravity with replacement of damaged battery lead clamps and worn out leads including taking down and fixing of batteries to its position complete all as specified and as directed by the Engineer-in-Charge.
Taking down high mast light of size 12/15/16 mtr from its base with help of crane, cleaning, greasing, and overhauling of all moveable parts like pullies,steel wire,chain,winches etc,replace unserviceable light if required and refix the mast on its original position complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs of Aviation light comprising aluminium housing and polycarbonated enclosure at any height and location complete all as specified and as directed by the Engineer-in-Charge. Make:-Bajaj/Havells/Crompton/C&S
S&F in repairs 12 Volt, DC, 75Ah/100Ah, maintenance free valve regulated Lead acid(VRLA) solar GEL Battery complete all as specified and as directed by the Engineer-in-Charge.
LEOENTERPRISES
suresh electricals
SHIKHARA PROJECTS
P NARAYANA RAO
SVG SUPPLIES
SRIVALLI ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .