Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 CrAccepted-AOC PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARAHILLS HYDERABAD HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | ₹17.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹19.4 CrRejected-AOC | ₹19.4 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹20.1 CrRejected-AOC | ₹20.1 Cr | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹18.0 Cr
EMD Value
₹5 L
Closing Date
13 Oct 2020, 5:00 pmClosed
Managing Director, KINFRA
KINFRA House, TC 31/2312, Sasthamangalam, Trivandrum-695010
Development works for Rice Technology Park at Palakkad for Kerala Rice Park Limited
2020_KINFR_388537_1
KINFRA/RTP-PLKD/11/2020-21
Open Tender
Civil Works - Others
300 days
Palakkad
As per NIT
3 documents required · 3 mandatory
₹17,850
online
₹5 L
KINFRA Mega Food Park, Palakkad
25 Jan 2021
29 Sept 2020
16 Oct 2020
29 Sept 2020
13 Oct 2020
6 Oct 2020
6 Oct 2020
Amount
Earthwork
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
Carriage of materials by mechanical transport including loading, unloading and stacking beyond 50 m initial lead up to 5 km, including all lifts involved as directed by the Engineer-in-Charge. Excavated Earth/rock
Concrete Works
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note :- Minimum Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)
Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards
Centering and shuttering including strutting, etc. and removal of form for:Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide
Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.
Extra for shuttering in circular work in Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Extra for shuttering in circular work Foundations, footings, bases of columns, etc. for mass concrete
Extra for shuttering in circular work in Suspended floors, roofs, landings, balconies and access platform
Extra for shuttering in circular work in Lintels, beams, plinth beams, girders, bressumers and cantilevers
Extra for shuttering in circular works- Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and walls Above 20 cm wide
Extra for shuttering in circular work in Edges of slabs and breaks in floors and walls Under 20 cm wide
Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.
Masonry Works
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.
Flooring Works
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Medium shade pigment using 50% white cement 50 % Grey cement
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying Anti-skid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.
Providing and fixing PVC tile edging to match the wall tiles and finishing as directed by the Engineer-in-Charge at all levels.
Joinery Works
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With pin headed glass panes of 4.0 mm thickness
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:250x10 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.
Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710
Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suitable for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded)
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately)
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
Supplying and fixing 200 mm Aluminium aldrop
Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.
Steel and PEB Works
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area
Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 16.80 sqm in area
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Design, material, fabrication, supply , erection, transportation, labour, supervision of Pre-Engineered superstructure,roofing and cladding as per drawing including all primary members, secondary members, roof & wall sheeting, canopy as per drawing, fasteners, sealer/rope sealer, closures/filler stripes, ridge cap, flashing and trim, eave gutters and downspouts, anchor bolts, ventilators and Turbo ventilators etc. complete as per the drawing and as directed by the Engineer-in-charge with the following specification at all levels. Unless specified all work shall conform to the latest Indian Standards. Building type: Clear Span (CS) as per drawing. Building area and height : As per drawing Building slope: As per drawing Type of End Frame: Post & Beam Design codes- IS 800-2007, IS 875 (Part 3 Wind load) 1987, IS 801-1975, IS 1893:2002, AWS D1.1.96,D1.1-2004 Roofing sheet: roofing system made out of 0.50mm TCT 550MPa 150GSM colour coated galvalume/zincalume sheet with silicon modified polyester coating of 20 microns of approved colour on the top over 5 microns primer and 5 microns back up epoxy coating at the bottom over 5 microns primer. Sheets will be in high rib profile with 28mm crest height in 195mm pitch with 975mm covered width and length can be as per the site requirement upto a maximum of 12m. Sheets will be fixed to the purln with imported self-drilling fasteners with EPDM washers for perfect sealing. Cladding sheet: Cladding with profiled sheets made out of 0.50 mm TCT 550 MPa 150 GSM colour coated Galvalume/zincalume sheet with silicon modified polyester coating of 20 microns of approved colour on the top over 5 microns primer and 5 microns back up epoxy coating at the bottom over 5 microns primer. Sheets will be in hi-rib profile with 28mm crest height in 195mm pitch with 975mm covered width. Sheets will be fixed to the girts with imported self drilling fasteners with EPDM washers for perfect sealing. Steel Work Finish: All primary members (Columns and Rafters) will be cleaned by Shot Blasting and Painted with Two Coats of zinc Chromate Primer (2*30 microns) and Two coats of Synthetic Enamel Paint (2*30 microns). The Welding for the Primary Structures are Single side Continuous Arc Welding. All secondary Members (Purlins, Girts, Eave struts and sag Angles) will be Galvanized (275gsm). All primary and secondary Bolts are Black Coated Except Anchor Bolts Turbo Ventilator- As per the design requirement. Gutter: Gutter made from metal sheets for both eave ends of the building as per drawing and design requirement . Down Water Pipe: Down water pipe upto GFL as per the standard. (Note: Plan area shall be measured for payment.)
Plant Building (Rice Mill) :Building Dimension as per Drawing
Pre Cleaning & Drying unit :Building Dimension as per Drawing
Finished Goods Storage :Building Dimension as per Drawing
Roofing and False ceiling works
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.
Finishing Works
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Melamine polishing on wood work ( one or more coat)
15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer in required areas at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)
Road and Paver Works
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m etc complete as per MoRTH Specification
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2 etc complete as per MoRTH Specification
Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading-II - Plant Mix Method etc complete as per MoRTH Specification
Construction of sub-grade and earthen shoulders with approved material obtained from roadway cutting with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 etc complete as per MoRTH Specification
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density etc complete as per MoRTH Specification
Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom etc complete as per MoRTH Specification
Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means etc complete as per MoRTH Specification
Dense Graded Bituminous Macadam :- For Grading II (26.5 mm nominal size)Providing and laying dense graded bituminous macadam with 80-100 TPH HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects as per MoRTH Specification
Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 325 mm high in M 20 Grade PCC Using Concrete Batching and Mixing Plant on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of MoRTH Specification
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes etc complete as per MoRTH Specification
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces etc complete as per MoRTH Specification
Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-etc complete as per MoRTH Specification
Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Miscellaneous works
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.With 20 mm diameter round bar
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )
Circular shape 560 mm internal diameter
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
Providing and fixing S.S fan clamp of 16mm dia in RCC slabs, beams including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levels.
Supplying and sinking in position RCC open well 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) up to 2.0 m inner diameter and depth maximum upto 10m in all kinds of soil other than rock to line and levels and plumb by scooping out from inside and below the steining .A layer of 6 mm aggregate,up to thickness of 30 cm shall be filled all around the well to act as a filter media which will be paid seperately under relevant item. The rate shall include the cost and conveyance of all materials ,labour , concrete , reinforcement ,shuttering including removal of obstacles to a suitable location as directed by the Engineer in Charge etc. complete as per drawing and as directed by Engineer - in - Charge
Supplying and stacking of stone Aggregate (Single size) : 6 mm nominal size at site
Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab(1:1.5:3) over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.
Providing and constructing soak pit 1.5 m x 1.5 m x 1.5 m size with honey comb brick work on the sides upto a height of 0.9m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.2 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.
Providing and fixing ferrocement septic tank for 25 users including cost and conveyance of all materials, labour charges,excavation, base PCC,back filling, lead, lift, sundries, etc . complete as directed by the Engineer-in-Charge at all levels
Water Proofing works
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.
Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.
Providing and Iaying PVC membrane waterproofing system over the vertical side for RCC wall. Installing geotextile of 300gsm as correction layer, over the vertical side of the wall, before installation PVC membrane 2mm thick of approved manufactor shall conform to the physical and chemical properties such as: Elongation at break (300%) UNI EN ISO 527-3 or equivalent, Ultimate Tensile Strength (> 16.7 N/mm²), Puncture resistance (> 1100mm) DIN 16726-5.12 or equivalent, Hydrostatic pressure Waterproof UNI EN 1928 resistance (6 hours at 5 bar) or equivalent on vertical side, providing and fixing suitable arrangement for fixing mechanically onto the vertical wall to hold the membrane in vertical position against sagging due to self weight of the membrane and without damaging the PVC membrane and providing and Installing 2mm thick synthetic membrane of plasticized PVC with double seam welding of PVC waterproofing membrane joints and pressure testing of the same to 2 bars up to 10 minutes and with compartmentalization by welding PVC water stop with welding fins at all construction joints and at strategic locations to make a compartment of 200 sqmtrs pre installed with required number of injection flanges in every compartment fitted with inlet / outlet pipe and surface access box. The cost shall include the cost for providing and Installing a minimum protection layer of 300gsm or 25mm thick EPS protection boards over the vertically installed PVC waterproofing membrane, on the vertical face of the retaining wall to act as a protection layer against backfill and all pressure release mechanism etc complete as directed by the Engineer In Charge. (The above work shall be carriedout by an agency having sufficient experience in membrane water proofing and should ensure a guarantee of 5 years). Only skilled and experienced persons shall be employed for this purpose. Only external surface area of retaining wall will be measured.
Providing and laying PVC membrane waterproofing system in horizontal plane including adjustment layer to take up any surface irregularities of the substrate, in order to avoid any imperfections or foreign particles damaging the waterproof layer. It shalll composed of geotextile, weight of 300 g/m2, laid in dry conditions with edge overlap of 10/15 cm. Synthetic membrane of plasticized PVC, 2mm thick of approved manufactor shall conform to the physical and chemical properties such as: Elongation at break (300%) UNI EN ISO 527-3 or equivalent, Ultimate Tensile Strength (> 16.7 N/mm²), Puncture resistance (> 1100mm) DIN 16726-5.12 or equivalent, Hydrostatic pressure Waterproof UNI EN 1928 resistance (6 hours at 5 bar) or equivalent. Double seam welding of PVC waterproofing membrane joints pressure tested to 2 bars of 10 minutes the waterproofing project to be divided into sectors if required and it is composed of shaped joints of PVC and it is welded to the existing waterproof liner.The rate shall be inclusive of providing and laying protection layer of non-woven 300gsm geo-textile membrane over the laid PVC waterproof membrane system, followed by a cement mortar screed of 50mm thick over the top layer of geo-textile membrane to facilitate the placing and tying of reinforcement bars of raft and all pressure release mechanism etc complete as directed by the Engineer-In-Charge.(The above work shall be carriedout by an agency having sufficient experience in membrane water proofing and should ensure a guarantee of 5 years). Only skilled and experienced persons shall be employed for this purpose.
Landscaping Works
Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler
Supplying river sand brought from outside including transportation, loading, unloading etc complete as directed by the Engineer-in- Charge
Supplying and planting healthy plants of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.
Supply and stacking of plant Nerium oleander (kaner) dwarf of height 30-40 cm. in earthen pot of size 20 cm as per direction of the Engineer-in-Charge.
Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 120 to 150 cms, shrubs to have a height of 30 to at the time of planting) Trees Tabernaemontana Divaricta.
Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 120 to 150 cms, shrubs to have a height of 30 to at the time of planting) Ground cover (min 30cm height) LANTANA YELLOW .
Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 120 to 150 cms, shrubs to have a height of 30 to at the time of planting) Shrubs Duranta Gold.
SANITARY WORKS
Providing and fixing vitreous china under counter wash basin of approved make andsize including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubber plug,s 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap,CP brass 15mm angle valve,complete including CI/MS brackets duly painted, nuts, washers, etc. complete,including cost andconveyance of all materials labour charges ,lead, lift necessary wall cutting / chasing and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model<br>no:Hindware 10049/Cera S2030104+ Jaquar catalogue no: OPP-15001PM or equivalent,+Jaquar catalogue no: ALD-705L130 or equivalent+Jaquar catalogue no: ALD 769 L 300 or equivalent+Jaquar catalogue no: OPP-15053PM or equivalent)
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
Providing & fixing star white vitreous china flat back urinal with CP brass flush valve auto closing system with built in control cock and wall flange of approved size with all accessories to<br>provide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead, lift,necessary wall cutting / chasing and making good the walls,floors,slab, as required for urinal flushing etc complete, testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model:Jaquar catalogue noL URS-WHT-132530+PRS-073 or equivalent).
Providing and fixing of star white vitreous china urinal division plate of approvedquality and make with fittings/fastener including cutting and making good the walls,floors,slab ,cost andconveyance of all material, labour charge, lead, lift, etc. complete as directed by the Engineer in charge at alllevels.(Model: Hindware catalogue no:61001 or equivalent)
Providing and fixing CP brass long body bib cock etc. complete including cost and conveyance of all materials labour charges ,lead, lift,including cutting and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at alllevels.<br>(Model:Jaquar cat no: OPP-15037PM or equivalent)
Providing and fixing C.P. brass concealed stop cock (control valve) of standard designand of approved make conforming to IS:8931 etc. including cost and conveyance of all materials, labourcharges, lead,lift, necessary wall cutting / chasing and making good the walls,floor,slab etc complete, testingand commissioning to the satisfaction of Engineer in charge at all levels. <br>(Model-Jaquar cat no: OPP-15083KPM+ALD-089FT or equivalent)
Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade<br>floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete<br>as directed by the directed by the Engineer in Charge at all levels
Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm dia
Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels.110 mm dia
Providing and fixing sanitary fixtures for handicaped toilet including one washbasin,one pair mounting brackets,one number pillar cock & all other related fittings like bottle trap,angle<br>cock,waste coupling, etc,one number EWC & Cistern complete with fittings & seat cover, one no.hinged rail 76cm & 4nos. of grab rails 60cm etc designed for people with special needs comes with as permanufactures specification including cutting and making good the walls and floors wherever required as perdrawing and as directed by Engineer in charge. (Model no: Hindware cat no : 70002 or Cera cruse set, Jaquarcat no: OPP-15001PM+ ALD 705L130+ALD 769 L300+OPP-15053PM or equivalent)
Providing and fixing CP brass sink cock of approved quality conforming to IS: 8931 etccomplete including cost and conveyance of all labour charges etc complete as directed by the Engineer incharge at all levels.(Models: Jaquar cat no: LYR-38347S or equivalent)
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
Providing and fixing liquid soap dispenser of approved make including cost and conveyance of all materials labour charges ,lead, lift, cutting and making good the walls, floors and slab wherever required etc complete, testing and commissioning to the satisfaction of the Engineer in Charge at all levels .(Models: Jaquar catalogue no: SDR-WHT-DJ0010F or equivalent)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 200 mm
Providing and fixing frameless mirror complete, with all four edges machine<br>polished/bevelled and back side protected with safety film and 4 mm thick BWP grade Plywood backing and<br>fixed on walls with mirror screws(spacer). The rate is including cost and conveyance of all materials, labour<br>charges, lead,lift ,cutting and making good the walls,floors,slab etc complete as directed by the Engineer in<br>charge at all levels
Providing and fixing floor trap with cockroach trap (multi trap) SS304 grade floor grating<br>with cup,PVC multitrap including cost and conveyance of all materials, labour charges, sundries,cutting and<br>making good the walls,floors,slabs etc complete as directed by the directed by the Engineer-in-Charge at all<br>levels.
WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal
Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal
Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
Providing and fixing C.I. basket type dirt box strainer for bulk type water meter withnuts, bolts, all accessories etc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer in charge 65mm dia
Providing and fixing C.I. basket type dirt box strainer 50mm dia for bulk type water meter with nuts, bolts, rubber etc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge.<br>150mm Dia<br>
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge.<br>80mm Dia<br>
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
Providing and fixing 110mm dia PVC vent cowl to pipe already fixed as directed by<br>Engineer-in-charge at all levels. 110mm dia
Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80<br>mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>100 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>80 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>65 mm nominal outer dia pipes
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200mm dia 6 Kgf/cm2
Supplying and fixing GM foot valve with all accessories including cost and conveyance<br>of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <br>40 mm
Supplying and fixing GM foot valve with all accessories including cost and conveyance<br>of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <br>50 mm
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 65mm
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 80mm
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 100mm
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 200mm
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 65mm
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 100mm
Providing and fixing 75mm dia PVC vent cowl to pipe already fixed as directed by<br>Engineer-in-charge at all levels. 75mm dia
Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer
Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 40mm 'Y' type strainer
Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 160 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work75 mm nominal inner dia pipes
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 150mm
Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber fittings etc. ( The tail pieces if required will be paid separately):<br>50 mm dia nominal bore
Providing and fixing enclosed type water meter (bulk type) 65mm dia conforming to IS :2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labouRretc. complete and as directed by<br>Engineer-in-Charge.<br>
Supplying, fixing and commissioning of centrifugal pump of CI construction, bronze impeller complete with motor,working with 415 V, 3 pH, 50 Hz including base plate foundation bolts, nuts,<br>pressure gauge, priming arrangements and all accessories. <br>'Capacity : 43m3/hr, Head : 33metre
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2
Providing and fixing heavy duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge.<br>600x600mm
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 160 mm dia 10 Kgf/cm2
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including<br>collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2<br>(1 cement : 2 fine sand) including testing of joints etc. complete.<br>300 mm dia RCC pipes.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
Supplying and installing activated carbon filter of size 20 m3/hr with internally and externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at inlet and outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, V-notch Board etc and all other accessories .The rate shall include cost and conveyance of all materials, labour etc.<br>complete and as directed by Engineer-in-Charge.
Supply and erection of dual media filter of vertical type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness, 6mm dish<br>thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves and graded<br>pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure, back wash<br>arrangement, etc and all other accessories .Flow rate 20m3/hr
Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels<br>>Head 35m, Capacity-20 m3/hr
Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels<br>Capacity : 10m3/hr Head : 31 m
Supply and installation of water level indicator with electronic integrated circuit and<br>necessary accessories etc complete as directed by the Engineer in charge at all levels
Supplying,installing, testing and commisioning of electronic integrated circuits and wireless water level controller including necessary cabling and transformers with all accessories etc complete as directed by Engineer in charge for water supply level control in water tanks
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Supplying and fixing of open well submerssible pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levels 10m3/hr:27 mHead
Supplying ,fixing, testing and commissioning of portable drainage pump with 12mm<br>solid handling, with stainless steel construction, stainless steel impeller complete with motor , with carrying<br>handle and all accessories and working with 415V, 3ph and 50 Hz frequencyCapacity:10m3/hour,Head-15m
Providing and fixing CI non-return valve of approved quality (screwed end):<br>100 mm nominal bore<br>
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5
Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal
Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreHorizontal
Supplying, Installing, Testing and Commissioning to the satisfaction of Engineer in charge of low noise 3 layered poly propylene pipes & push fittings (PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102 and specials of approved make such as tees elbows, unions, bends, sockets bends, flanges, reducers, end caps, saddles, plugs, coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers, ferrule, pipe supports, cost of extra wastage of fittings during laying of pipe line etc. hire of tools and plant, cost and conveyance of all materials, labour charges, including testing pipe line to the specified hydrostatic test pressure, rectifying any leakage or defects etc. complete for concealed works as directed by Engineer-in-Charge at all levels.(Proper pipe supports shall be provided at suitable locations.) 110 mm dia
Supplying, Installing, Testing and Commissioning to the satisfaction of Engineer in charge of low noise 3 layered poly propylene pipes & push fittings (PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102 and specials of approved make such as tees elbows, unions, bends, sockets bends, flanges, reducers, end caps, saddles, plugs, coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers, ferrule, pipe supports, cost of extra wastage of fittings during laying of pipe line etc. hire of tools and plant, cost and conveyance of all materials, labour charges, including testing pipe line to the specified hydrostatic test pressure, rectifying any leakage or defects etc. complete for exposed works as directed by Engineer-in-Charge at all levels.(Proper pipe supports shall be provided at suitable locations.) 110 mm dia
Supplying, Installing, Testing and Commissioning to the satisfaction of Engineer in charge of low noise 3 layered poly propylene pipes & push fittings (PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102 and specials of approved make such as tees elbows, unions, bends, sockets bends, flanges, reducers, end caps, saddles, plugs, coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers, ferrule, pipe supports, cost of extra wastage of fittings during laying of pipe line etc. hire of tools and plant, cost and conveyance of all materials, labour charges, including testing pipe line to the specified hydrostatic test pressure, rectifying any leakage or defects etc. complete for external works as directed by Engineer-in-Charge at all levels.(Proper pipe supports shall be provided at suitable locations.) 110 mm dia
Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels<br>Capacity: 10m3/hr<br>Head: 15m
HT EQUIPMENTS- 11 KV DP STRUCTURE Supply, Installation testing and commissioning of 11 kV 13 m DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and supporting structure for 11 kV components with 65x65x6 mm MS angle bracings between consumer and supplier structure,cross arms, 11 kV pin,disc insulators and stay insulators, stay wire, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbig arrangement using barbed wire,earthing etc. on a suitable concrete foundation including the cost of foundation.The DP structure shall consists of the following (Note:All the MS items shall be hot dip galvanised)(Note:The work shall be as per KSEI & KSEB standards) 11 kV, 400A , single brake,TP, gang operated AB switch with operating handle & locking mechanism - 1 No 11 kV Lighting Arrestor -1 set of 3 Nos 11 kV Drop out fuses-1 set of 3 Nos .The DP structure shall be with all necessary accessories for connecting 11kV cable .
Chain link fencing Supply and fixing of 1.8 mtr high chain link fencing over 600 mm high random rubble masonry as per drawing and specification, using 4 mm thick PVC coated UV stabilised chain link with a framework of 50x50x6 mm MS angle between vertical posts of ISMC 75 mm at 2400 mm intervel, which are fixed to the concrete footing (1:3:6) of size 450x450x300 mm (above GL) with adequate footing depth, between the RR masonry. RR masonry (450 mm thick) and 300 mm from ground level for foundation & plinth in in cement mortar (1:6). The random rubble masonry is to be pointed using cement mortar 1:3 to have a flush finish. Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing.The MS frame work for chain link fencing is finished using zinc chromate primer & 2 coats of synthetic enamel paint. 1.5 mtr wide gate shall be provided with suitable locking arrangements.The rate shall be inclusive of all materials, labour, lead, lift, etc including excavation works and fabrication and assembly works including all nuts, bolts & other miscellaneuos items, etc. complete as per drawing
Supplying and filling the proposed yard with 40 mm size blue jelly of 150 mm thick including cost and conveyance of all materials, labour charges etc. complete.
HT Metering Kiosk Supply, installation, testing and commissioning of TOD meter KIOSK with TOD meter (with RS485 or RS232 communication facility), CT(0.2S) and PT(0.2) ,test terminal block, control fuses,armoured copper cable between CTPT unit. The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 65 with canopy, weather proof,undergone seven tank process,powder coated finish ,earthing,entire civil work including suitable foundation and all mounting accessories as required complete as per the rquirement of State Electricity Board. The metering cubicle shall have glass window for meter reading and locking facility.
TRANFORMER AND ACCESSORIES- UNITIZED SUBSTATION- 800KVA Design, fabrication,Supply, installation, testing and commissioning of outdoor type Unitized Substation including RCC foundation for 800 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 54 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works icluding RCC foundation etc. complete as per single line diagram & technical specification. HT Chamber : 800A 25kA(3sec) 11kV VCB with earth switch (Non drawout type) CTs of 100/5A 15VA 5P10 50/51 50N/51N numeric overcurrent and earth fault relay( with DC trip) Transformer Compartment:800kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, outdoor distribution Transformer. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 10% to -10% in steps of 2.5%. Necessary cooling fans shall be provided winding temperature, alarm trip relay. The transformer shall also have suitable enclosure including supply and fixing of neutral CTs of 200/5A 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in MSB. LT Chamber:Suitable for terminating 4 runs of 3.5 sqmm 400 sqmm cable.
HV CABLES AND CABLING Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date.
3C X 300 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number 11 kV grade XLPE cable of size not exceeding 400 sq.mm in the existing RCC/ HUME/ STONEWARE/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.
Above 120 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on wall or surface as required.
Above 120 sq. mm and upto 400 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3C x 300 sq.mm.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3C x 300 sq.mm.
Providing, laying and fixing following dia RCC pipe NP4 class HEAVY duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (1.2 m deep) and refilling etc as required.
300 mm dia
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
DG AND ACCESSORIES 125 kVA DIESEL GENERATOR Supply, Installation, Testing and Commissioning of 125 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 125 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inculsive of all the civil work like RCC foundation etc. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.
500 kVA DIESEL GENERATOR Supply, Installation, Testing and Commissioning of 500 kVA prime rated D.G Set with outdoor acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc., including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 500 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inclusive of all the civil work like RCC foundation etc. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.
UPS AND ACCESSORIES Supply , Installation, Testing and Commissioning of 7.5 kVA, three phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation
Supply , Installation, Testing and Commissioning of 5 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation
Supply , Installation, Testing and Commissioning of 2 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation
CABLES AND CABLING Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date.
3.5C 400 Sq.mm Al
3.5C 240 Sq.mm Al
3.5C 150 Sq.mm Al
3.5C 120 Sq.mm Al
3.5C 70 Sq.mm Al
4C 35 Sq.mm Al
4C 16 Sq.mm Al
4C 10 Sq.mm Al
3C 185 sqmm Al
3C 10 sqmm Al
3C 4 sqmm Cu
2C 10 sqmm Al
2C 4 sqmm Cu
4C 2.5 sqmm Cu
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C 400 Sq.mm Al
3.5C 240 Sq.mm Al
3.5C 150 Sq.mm Al
3.5C 120 Sq.mm Al
3.5C 70 Sq.mm Al
4C 35 Sq.mm Al
4C 16 Sq.mm Al
4C 10 Sq.mm Al
3C 185 sqmm Al
3C 10 sqmm Al
3C 4 sqmm Cu
2C 10 sqmmAl
2C 4 sqmm Cu
4C 2.5 sqmm Cu
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1kV grade fo the following sizes in ground including excavation ,sand cushioning , providing protective covering and refilling the trench etc. as required
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100 mm dia
Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required
600 MM WIDTH X 50 MM DEPTH X 2 MM THICK
450 MM WIDTH X 50 MM DEPTH X 2 MM THICK
300 MM WIDTH X 50 MM DEPTH X 2 MM THICK
150 MM WIDTH X 50 MM DEPTH X 2 MM THICK
Fabrication, supply and installation of following size of perforated GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required
300 MM WIDTH X 50 MM DEPTH X 2MM THICK
150 MM WIDTH X 50 MM DEPTH X 2 MM THICK
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.
WIRING AND ACCESSORIES Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.(Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 52.01) Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 52.01)
Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point(without independent switch etc.) with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required.(Note:The total distance from one point to another the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 52.01)
Circuit wiring -Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
3x1.5sqmm
3x2.5sqmm
3x4sqmm
Supplying and fixing following modular switch/ socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.
15/16 amp switch
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)
Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
MCBs AND MCB DISTRIBUTION BOARDS Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 125/160 amps TP 16/25 kA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100Amp,25kA ,FP MCCB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (8 + 24), Double door
6 way (8 + 18), Double door
4 way (8 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
4 pole 63 amps. (415 Volts), 100mA sensitivity.
4 pole 40 amps. (415 Volts),30mA sensitivity.
2 pole 25 amps. (240 Volts), 30mA sensitivity-
Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.
6A to 32A, SP, B/C-CURVE
40-63A FP MCB,
6-32A TP MCB,
6A to 32A, SP, D-CURVE
Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)
Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB
Cable end box for 8 way double door horizontal type TPN DB
Cable end box for 4 way double door horizontal type TPN DB
Cable end box for 12 way double door horizontal type SPN DB
Supply, Installation, Testing & Commissioning of 32 A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.
LIGHT FIXTURES AND FANS Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,with a maximum system wattage of 40 Watts,lumen output of luminaire greater than 4000 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24
Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,with a maximum system wattage of 20 Watts,lumen output of luminaire greater than 2000, power factor >0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Osram Luxsmart LED batten G2 or equivalent approved make
Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuser ,along with driver,with a maximum system wattage of 10 Watts,lumen output of luminaire greater than 1000, power factor > 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100 lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: OSRAM LUXSMART led BATTEN G2 or equivalent approved make
Supply of Symmetric LED Highbay fixture with encapculated potted driver,system wattage maximum of 80 Watts,lumen output of luminiare greater than 9500 lumens, IP 65, Wide beam, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 120 lumen/watts, with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Philips make BY325P LED100S CW PSU GR FG WB XTFCL V1 or equivalent make
Supply of LED recess mounted down light made of die cast aluminium, along with driver,system wattage of 18+/-3 Watts, CCT- 5700K (warm white) with lumen output of luminaire greater than 950 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 90 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO LD90-231-XXX-65-XXor equivalent approved make
Supply of Symmetric LED Highbay fixture with encapculated potted driver,system wattage maximum of 105 Watts,lumen output of luminiare greater than 12500 lumens, IP 65, Wide/Narrow beam, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 120 lumen/watts, with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Philips make BY325P LED130S CW PSU GR FG WB XTFCL V1 or equivalent make
Supply of Symmetric LED Highbay fixture with encapculated potted driver,system wattage maximum of 132 Watts(+/-5),lumen output of lamp greater than 15500 lumens, IP 65, Wide/narrow beam, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 120 lumen/watts, with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Philips make BY325P LED160S CW PSU GR FG WB/NW XTFCL V1 or equivalent make
Supply of Symmetric LED Highbay fixture with encapculated potted driver,system wattage maximum of 160 Watts(+/-10), lumen output of lamp greater than 19000 lumens, IP 65, Wide beam, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 120 lumen/watts, with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Philips make BY325P LED195S CW PSU GR FG WB/NW XTFCL V1 or equivalent make
Supply of recess mounted LED panel light fixture light made of die cast aluminium with corrosion resistance p[owder coating, along with driver,system wattage of 36 +/- 2 Watts with lumen output of lamp not less than 3600 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No:Wipro: ElateLED or equivalent one)
Supply, installation, testing and commissioning of flood light luminaire with die cast aluminium housing with powder coated finish, with suitable driver,system wattage 100+/-10Watts,lumen output of lamp greater than 10000 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, IP 65 compliant including all necessary accessories as required complete. Make :- Cat number Wipro LF20-122-XXX-57-XX or equivalent approved make
Supply of outdoor Bulkhead LED light fixture with pressure die cast aluminium housing and Polycarbonate Diffuser with IP66 cover,along with driver,system wattage of 12+/-2 Watts,lumen output of lamp greater than 1100, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips WT202W LED10S CW PSU S3 PC or equivalent approved make.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)
Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)
Supply of 450 mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: ALMONARD or equivalant approved make)
Supply of 400 mm size wall fan having speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor and all accessories as required complete. (Make: Crompton Greaves Hi Flo 3 Blade Wall Fan or equivalant approved make)
Supply of 750 mm size wall mounting oscillating type air circulator with regulator suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make: Almonard air circulator 750 mm or equivalent approved make).(Waiting Area)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required.
Installation, testing and commissioning of High bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.
Installation, testing and commissioning of LED fittings with GI chain - Installation testing and commissioning of prewired fluorescent / LED fittings of all types complete with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.
P/F extra chain with copper wiring- Providing and fixing extra chain 2x10 cm length with using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor including painting etc. as required. (more than 5 cm length shall be rounded to the nearest 10 cm. and 5cm or less shall be ignored)
Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete.
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.
EARTHING AND SAFETY EQUIPMENTS Earthing with C.I. earth pipe 3 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 600X600mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)
Supply,installation ,testing and comissioning of maintenance free earthing using 3 mtrs length,20mm dia 250 microns molecularly copper bonded steel rod, stainless stell connectors and fasteners for connecting earth strip.The earth electrode shall be filled with earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound).FRP (UFE FRP)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 300mmx 300mmx 300mm with a weight bearing capacity of 15KN.The item shall be inclusive of installation charges,including digging bore,providing all required accessories like terminal connector,screw for fixing earth pit cover etc
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.
50mm X10mm GI
25mm X 6mm GI
25mm X 3 mm Cu
3.15mm Cu (10 SWG)
4mm GI (8 SWG)
4mm Cu (8 SWG)
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
50mm X10mm GI
25mm X 6mm GI
25mm X 3 mm Cu
3.15mm Cu (10 SWG)
4mm GI (8 SWG)
4mm Cu (8 SWG)
Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .
Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .
Supply and fixing of First aid box
Supplying of Rubber hand gloves suitable for 11 KV.
Supply and fixing anodised aluminum glass framed shock treatment chart.
Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
LIGHTNING PROTECTION Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip
Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-3
4Mtr Airterminal
2Mtr Airterminal
EXTERNAL LIGHTING High Mast Design & Supply of 25m height high Mast lighting system with accessories. Mast shaft shall be in 3 section , hot dip galvanized having top dia minimum 150 mm,bottom dia and plate thickness as per the structural requirement and suitable for wind velocity as per IS 875 part 3.It shall also include accessories for high mast including head frame ,stainless steel wire rope of minimum dia 6 mm , lightning arrestor, 2nos Earthing with C.I. earth pipe 3 metre long, 100 mm dia including connection to High mast earth terminal with 25 X 6 mm GI flats with accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 amended up-to-date) There shall be a control panel housing suitable rating switchgear, separate Contactors & timers for LED luminaire circuit, 24 hrs Digital Timer with inbuilt battery and control circuit at the bottom of the mast with suitable provision for incoming and outgoing cable termination. Flexible copper trailing cable of minimum 5 core 4 sq.mm shall be provided from bottom to top. This cable shall be terminated at a galvanized junction box at the top.From this junction box to the luminaires minimum 3 core 1.5 sq mm flexible PVC cable through flexible conduit shall be used, double drum winch,galvanised Lantern carriage arrangement suitable for required no of 300W LED Luminaire as per design and its drivers ) arranged as per design. High mast shall be provided with twin dome aviation obstruction lamps. Minimum galvanizing thickness of 65 microns should be maintained uniform through out the mast . Supply of single gear double drum winch having capacity of minimum 750kg and operating speed of suitable rpm, 2 nos of 6mm 304 Wire rope with safety factor over 5,metal clad socket with cap and hooking arrangement for power tool should be provided inside with each mast, portable power tool having output speed of suitable rpm, torque limiter, operating handle for manual operation etc,Trailing cable having adequate current rating etc as required complete.
Supply of suitable LED flood light fixtures, with maximum system wattage of 300W. complete with all necessary accessories like led drivers, prewired upto a terminal block including necessary accessories,IP 65, light fixture lumen output more than 40000lumens and connections suitable for operation on 230V, 50Hz AC supply. ( Make Bajaj 300W BENP 20FL or equivalent approved make )
Installation, testing and commissioning of 25m height high Mast lighting system with all accessories including design and supply of all materials, LED type twin dome aviation obstruction lamps and casting of suitable shallow foundation with square footing using M-25 concrete for the mast considering the safe soil bearing capacity at site as 10 T/sq. mtr. at suitable depth, filling the basement of highmast foundation pit .Backfilling the excavated ground after casting the foundation, earthing and supply a set of steel foundation bolts manufactured from special steel along with nuts, washers anchor plates and templates for each masts. The erection of the masts should be done with the help of suitable equipment.
Supply, erecting, installing testing and commissioning of 7 meter street light pole and LED street light fixture. The pole made out of hot dip galvanised 3 mm thick MS sheet, primered and octagonal pole with single arm bracket . The pole should have a flush door at bottom with inbuilt control box, proper cutout and provision for mounting DP MCB,four pole connector for easy loop-in loop-out,concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture. The pole shall be installed on existing civil foundation with foundation bolt. Along with LED street lighting fixture with die cast aluminium housing ,system wattage maximum of 55 Watts,lumen output of lamp greater than 6500 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 120 lumen/watts, with suitable driver IP 65 complaint and including all necessary accessories as required complete.
Supply
Supply, installation testing and commissioning of of LED bollards with a dia of 130 mm and 500 mm height having symmetrical illumination on ground surfaces with uniform luminance. LED lamp upto 10W can be fixed in the fixture. The body shall be made of extruded aluminium alloy with high corrosion resistant stainless steel screws. Glare free reflector system encased in clear uv protected polycarbonate diffusers for rotationally symmetrical distribution of light. Luminaries provided with LED driver ,MCB control and suitable for operation on 240V, 50Hz single phase ac supply. IP 44 compliant Bollards are mounted with E27 holders IP65 class protection & Terminal Connectors for Loop-in Loop out System.(KLITE 6956L1 or equivalent approved make)
DX TYPE UNITS - HI WALL SPLIT UNITS Supply, Installation, testing and commissioningof minimum 2.0 TR capacity Hi wall Split air conditioning unit(Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,outdoor unit and hi wall units for single phase 230 V supply minimum 3star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation ,suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19mm thick closed cell elastomeric insulation as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports finished with an 8 oz canvas cloth covering adhered between two coats of fungicidal protective coating,necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 12mm thick closed cell elastomeric insulation as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, finished with an 8 oz canvas cloth covering adhered between two coats of fungicidal protective coating suitably supported on trays, clamps etc first charge refrigerant gas R410A/R407C, cordless remote etc complete as required. ,inclusive of all taxes etc. complete as required as per specification/ISHRAE standards.
Supply, Installation, testing and commissioningof minimum 1.5 TR capacity Hi wall Split air conditioning unit(Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,outdoor unit and hi wall units for single phase 230 V supply minimum 3star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation ,suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19mm thick closed cell elastomeric insulation as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports finished with an 8 oz canvas cloth covering adhered between two coats of fungicidal protective coating,necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 12mm thick closed cell elastomeric insulation as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, finished with an 8 oz canvas cloth covering adhered between two coats of fungicidal protective coating suitably supported on trays, clamps etc first charge refrigerant gas R410A/R407C, cordless remote etc complete as required. ,inclusive of all taxes etc. complete as required as per specification/ISHRAE standards.
Air Distribution System Supply, Installation, testing and commissioning of acosutically inuslated in-line axial toilet exhaust fans with three phase direct driven motor of following capacity for exhaust complete with starter, required lengths of power and control wiring, clamping, earthing other accessories, supports etc. complete as required by the technical specifications.
200CFM ESP -10 mm of w.g
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
0.63 mm (24 Gauge)
Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers with damper,bird screen etc. complete in all respects as required by the technical specifications.
FIRE HYDRANT SYSTEM AND SPRINKLER SYSTEM Supplying, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2280 lpm at 90m. head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
Supplying, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2280 lpm at 90m. head conforming to IS 1520. (b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,2x12v 180AH Batteries and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity 300 Litres) with level indicator, By-pass line,MS Piping to diesel tank from engine, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
Supplying, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Vertical, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 90 m. head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads .
Supply, installation, testing and commissioning of electric driven pump set suitable for automatic operation and consisting of following, Monoblock Pump rated for 900lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP Squirrel cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation. Suitable cement concrete foundation, foundation bolts, anti vibration pads etc. as required including suitable capacity star delta starter and one isolator near the pump complete with all necessary cabling and accessories to provide successful automatic operation of the pump as per the technical specification.
Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 150 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.
Supply, installation, testing and commissioning of industrial type differential pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required as per technical specification.
Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories,and painting with synthetic enamel paint of approved shade as required as per technical specification.
Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/ IS 3589 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification.
200 mm dia (Pipe thickness 6.35mm)
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification.
150 mm dia
100 mm dia
80 mm dia
Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 rating conforming to API 594 complete with CI body, rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification.
200 mm dia
150 mm dia
100 mm dia
65 mm dia
Supply, installation, testing & commissioning of double flanged sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with GI nuts, bolts, washers, gaskets and conforming to IS 14846 of following sizes as required as per the technical specification.
200 mm dia
150 mm dia
100 mm dia
80 mm dia
Supply, installation, testing and commissioning of butterfly valve having PN 16 rating conforming to IS 13095/API 609 complete with CI body, SS Disc, Nitrile Rubber/EPDM seal, O -ring, flanges, GI nuts, bolts, washers etc. as required as per technical specification.
150 mm dia
100 mm dia
80 mm dia
65 mm dia
40 mm dia
Supply,installation, testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain, GI nuts, bolts, gasket etc as per technical specification.
Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe
Supply, installation, testing and commissioning of 63 mm dia, 15m long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636:2018 (type-1) as required as per technical specification.
Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.
Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.
Supply, installation, testing and commissioning of water monitor standpost type, made out of IS:1239 seamless steel tubes, hot dip galvanised, 75mm N.B. flanged inlet having ANSI B 16.5 drilling welded to 63mm reducer, IS:318 LTB2 gunmetal ball bearing swivel joints with brass locking arrangement, permitting of 360 degrees horizontal, 80 to -45 degrees vertical traverse, 32mm bore aluminium/copper alloy nozzle with male threaded inlet suitable for a discharge of 1750 l.p.m. at 7kg/cm2 pressure, 53m horizontal throw at 30 deg. angle in still air, bearing IS:8442 mark complete with flanges, gasket,nuts, bolts, etc. as required as per the technical specification.
Supply, installation, testing and commissioning of Fire brigade collective breaching with 4 nos. of 150 mm flanged out let connection and built in check valves complete as required as per technical specification.
Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification
Supply, installation, testing and commissioning of Y strainer with CI body, 3 mm perforated SS screen, flanged end connection, of following size confirming to IS specifications complete with GI nuts, bolts, gaskets, seal and accssesories as required as per the technical specification.
150 mm dia
100 mm dia
80 mm dia
Supply, installation, testing and commissioning of EPDM Rubber Flexible connectors (Vibration isolator/Expansion Bellows) of following sizes complete in all respects as required by the technical specifications
150 mm dia
100 mm dia
80 mm dia
65 mm dia
Design, supply, installation, testing and commissioning of orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 7 kg/cm2 complete as required.
Providing, fixing, testing & commissioning of sprinkler of the following type :
Standard response, standard coverage sprinkler, upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. complete as required as per the technical specification.
Quick response, extended coverage sprinkler ;3/4" NPT, K-11.2, Chrome Finish; operating temperature at 68 deg.C, complete as required as per the technical specification.
Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with IP55 class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 15Kg/cm2 and operating pressure ranging from 3.5kg/cm2 to 10Kg/cm2. complete as required as per the technical specification.
Supply, installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, GI pipe of required size, flanges, orifice plate, gasket etc. complete as required as per the technical specification..
PORTABLE FIRE EXTINGUISHERS Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.
Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.
Supply and installation of Mechanical foam extinguisher of ISI marked 9 litres capacity complete in all respects including initial fill. The Extinguisher should be manufactured and perform strictly as per IS: 15683:2006 complete as required as per the technical specification.
Supply, installation, testing and commissioning of Modular(Cealing mounted) ABC type extinguisher of 5Kg complete as required as per technical specification.
FIRE DETECTION AND ALARM SYSTEM Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke and heat) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be UL listed/FM Approved.
Supply, installation, testing and commissioning of Addressable/ Conventional with addressable module beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc complete as required as per the technical specifications. The product shall be ULlisted/FM approved.
Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be UL listed/FM Approved.
Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be UL listed/FM Approved.
Supply, installation, testing and commissioning of addressable type or conventional with addressable module 5A 24v Power supply unit for hooters with battery backup complete in all respect and as required as per technical specification.
Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be UL listed/FM Approved.
Supply, installation, testing and commissioning of UL listed/ FM approved microprocessor based intelligent addressable main fire alarm panel having 1 loops, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to connect printer to printout log and facility for integration with PA-Talk back system or analog/digital voice evacuation system, etc and complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers
Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occur, as per the technical specification. The product shall be UL listed /FM Approved.
Supply, installation, testing and commissioning of wall mounted talk back unit including all necessary accessories complete as required as per the technical specification..
Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.
Supply and laying of 2x 1.5sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above ground.
Supply and laying of 25mm dia PVC conduit along with accessories like PVC bends,couplers,junction box,fastners, iron staples/saddles/screws,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit etc. and complete as required as per the technical specification.
Supply, installation, testing and commissioning of CO2 Liner heat detection/trace tube panel flooding system for electrical panels consisting of CO2 cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, suitable capacity cylinder (One number), also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification.
SIGNAGE Supply and installation of glow signage (photoluminescent) such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite, panel conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
Supply and installation of glow signage (photoluminescent)of FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
Supply and installation of glow signage (photoluminescent)of "FIRE ORDER" of standard size (500*800 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
Supply and installation of glow signage (photoluminescent) such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
Supply and fixing of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwitched in Clear acrylic sheets fixed using SS Studs and other accessories, conforming to IS 9457, complete as required as per the technical specification.
DATA AND VOICE
Supply, Laying, Testing,Termination and commissioning of U/UTP cable - Category 6 , 4 pair, 23 AWG solid copper conductor, 600 MHz, CMR- with Fluke DTX 1800 Cable Analyser through existing conduits including termination, numbering tags ,Cable ties, ferrules and all accessoreis required as per specification.
Supply, Laying, Testing,Termination and Commissioning of Outdoor Category 6 cable , Outdoor, 4 pair, 23 AWG solid copper conductor, 600 MHz, CMR- with Fluke DTX 1800 Cable Analyser through existing HDPE conduits including termination, numbering tags ,Cable ties, ferrules and all accessoreis required as per specification.
Supply, Laying, Testing,Termination and Commissioning of one number of 6C Fiber Optic SM outdoor cable through existing conduits/trench or pipes as per specification
Supply, Laying, Testing and Commissioining of PVC Conduits, ISI, Class B, Medium Grade of 25mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.as per specification.
Cutting/ Chipping the wall for laying of conduits and making good the surface with all accessories as required at site to complete the installation.
Supply, Installation, Termination, Testing and Commissioning of Information Outlet for Data/Voice, Access Control , RJ 45 with all accessories required including termination complete as per specification
Supply, Installation, Testing and Commissioning of Metal Back Box for CAT 6 information outlet as per specification.
Supply, Installation, Testing and Commissioning of Dual Shuttered Face Plate with all accessories required as per specification.
Supply, Installation,Testing and Commissioning of Single Shuttered Face Plate with all accessories required as per specification
Supply, Installation,Termination, Testing and Commissioning of Patch Cord with end terminaiton for both data and voice with all accessories required as per specification.
Supply and Installation of PVC cable channel 45mm x 45mm as required.
Supply, Installation,Testing and Commissioning of 24 port patch panel with shutter fully loaded, including termination as required complete as per specification
Supply, Installation,Testing and Commissioning of 24 port voice patch panel with shutter fully loaded, including termination as required complete as per specification
Supply, Installation,Testing and Commissioning of 24 Port - Layer 2, switch 10/100/1000Base-TX ports with 2 x SFP+ ports with all necessary hardware & accessories, etc. as required at site as per specification.
Supply, Installation Testing and Commissioning of 12 port LC Single mode Rack mount Fiber enclosure LIU, Fully Loaded (with adapters / Couplers / Splice Tray / Splice holder) with all accessiries required as per specification
Supply Installation testing and commissioning of Fiber duplex patch Cord SM LC-LC with all accessiries required as per specification
Supply Installation testing and commissioning of SFP /SX (LC Type) transceivers supporting 1G with all accessiries required as per specification.
Supply, laying, testing and commissioning of 32mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. including excavation and refilling of trench/RCC road crossing, if required, complete including all necessary accessories required at site to complete the work as per specification.
Supply and laying of 50mm GI pipe ISI mark of class B medium with all accessories as required at site as per specification.
Supply, installation, testing and commissioning of Network Rack of following sizes along with all necessary hardware & accessories, etc.complete as required as per specification.
42U Server rack (800mmx1000mm)
Supply, installation, testing and commissioning of IP enabled EPBX System with Analogue Extension cards for 100 Analog extensions, 1 PRI etc. including all hardware, necessary licence ,softwares, operator console, both for software and hardware etc. required to complete the work as per specification
Supply and laying of 50 pair outdoor riser cable including termination as required as per specification
Supply, installation, testing and commissioning of 100 Pair MDF Box with Krone Modules with all accessories as required at site as per specification
Supply, installation, testing and commissiong of Analog phones as per speciication
Supply, installation, testing and commissiong of Firewall for 100 User Licence as per specification
Supply installation, Testing and Commissioning of IP Bullet Camera, Low-Light, 120Db wide Dynamic, IR Rugged Bullet Camera, 1/2.7inch imager, 4MP, 3.6mm lens, 3 IR LED's PoE, H.265, IK10 with all the required accessories to complete as per specification.
Supply, Installation, connection, configuration, operation, testing and commissioining of 16 Channel NVR with all other accessories as per specification.
Supply Installation, testing and commisioning of 8TB Hard Disk as per specification.
Supply, Installation, testing and commissioning of 55" commercial display 24/7 with HDMI, VGA, USB ports as per specification
Supply, Installation Testing and Commissioining of 8 Port PoE Layer 2 switch 10/100/1000Base-TX ports with 2 x SFP ports and single Port PoE Power Output 30W, Web Management Port with all accessories as per specification.
Supply Installation Testing and Commissioning of Desktop PC (i3 Processor with NVIDIA Graphics card) with monitor and keyboard as per specification
Biometric Attendance
Supply, installation, testing and commissioning of Biometric attendance / Access Control machine with software etc. required including all accessories required at site as per specification.
FURNITURE WORKS
Supplying and installing BOSQ TQ-W-101 or equivalent .The seat is made up of Nylon base 330 mm , synchronised simple/multi-function mechanism electroplated/powder coated TUV CLASS 4 Gas spring : 120 mm Seat . Upholstered with PU foam& back with mesh : Imported fabrics . Soft & adjustable lumbar support. <br>
Supplying and installing BOSQ JAZZ-301 or equivalent. 2.1 mm thick powder coated mild steel frame. Jazz Special –Lumber support. Seat upholstered with PU foam and back with mesh: Imported Fabrics
Supplying and installing AVID MID BACK-SEAT or equivalent: The seat should be made up of 1.4 ± 0.1 cmthick liot - prejsedOyvira(Sel, moulded polyurethane foam and upholstered with fabric. MORE INTERIODESIGN SEAT SIZE: 50.0cm (W)x 49.0cm(D). - - 2. BACK ASSEMBLY: The two part assemblyupholstered with Mesh fabric should be made up of back outer injection moulded in glass filled Polyamideand back inner injection moulded in glass filled Polypropylene. The back consist of adjustable Lumbarsupport made of injection moulded Polyoxymethylene (POM) which should be upholstered with foam andfabric having an adjustment of 5.5 ±0.5 cm. BACK SIZE: 48.0 cm(W) x 54.5 cm(H). 3. POLYURETHANEFOAM: The polyurethane foam for seat should be of density = 55 ± 3 kg/m3. 4. FOUR-WAYADJUSTABLE ARMRESTS: It should be made of glass filled Polyamide arm structure with PU armtopand height adjustment of 9.0 ±0.5cm.The armtop has swivel,side-to-side and to-fro movements. 5.MECHANISM: The mechanism should be designed with the following features: • 360° revolving type. •Auto-balance synchro - tilt • 4 position (including upright lock) giving option of variable tilt angle to thechair. 6. SEAT DEPTH ADJUSTMENT: Seat depth adjustment should be integrated in the seat through asliding mechanism. Seat depth adjustment range should be of 4.5±0.5 cm. 7. PNEUMATIC HEIGHTADJUSTMENT: The CLASS-4 pneumatic height adjustment has stroke of 9.5 ± 0.5cm. 8. PEDESTALASSEMBLY: The pedestal should be injection moulded in glasss filled Polyamide and fitted with 5 nos.twin wheel castors. The pedestal should be 67.0 ±0.5 cm P.C.D. 10.TWIN WHEEL CASTORS: The twinwheel castors are injection moulded in Polyamide having 6.0± 0.1cm wheel Diameter.
Supplying and installing TIME OUT 4 SEATER PU COATEDor equivalent, size shall be 1135 Width mm x1175 Depth mm x 750 Height mm . Top shall be 25 mm thick base material shall be 25 mm MDF board .On top PU painting of minimum 2H hardness with 75% glass as per color chart .Combination colorgraphics on the centre . Brown Laminate on bottom specially profiled edges for comfort . TheUnderstructure shall be having bend pipe structure of MS powder coated . Pipe dia 38 mm , 2 mm thickand it shall be fitted with top by SS machine screws . Legs shall be of MS powder coated and 38 mm dia.pipe legs are fixed with inderstructure and table top . Glide shall be of Plastic fixed at the understructureto prevent the damage of table top during stacking .
Supplying and installing TRIDENT JUNIOR 1 MAIN DESKor equivalent, size shall be 1200 Width x 600Depth x 743 Height . Top shall be of 18 mm thickness made of PLT board with 2 mm Edge banding.Wenge and savannah Maple PLT board shall be used. The Understructure shall be in pre-laminatedpanels made with PLT boards . 2- Drawerand 3 - Drawer storage units with different combinations tosupport tops made with 18 mm PLT boards of different colours.Modesty and back panels made with 18mm PLT boards. The pedestals / storages shall be fitted with necessary locks.
Supplying and installing AXIOM MAIN DSK+ERU LH BVRN BCH or equivalent-MAIN DESK | Size: 1600(W) x 800 (D) x 750 (H)<br>Main Top: 1600 x 800. Made of 48mm Thick (41mm) PLB. Edge banded withmatching PVC lipping.<br>Side Panel: 790 x 702. Made of 48mm Thick (41mm) PLB. Edge banded withmatching PVC lipping.<br>Modesty Panel: 1345 x 476. Made of 18mm Thick (41mm) PLB. Edge bandedwith matching PVC lipping.<br>ERU Size: 1800 (W) x 480 (D) x 645 (H)<br>Main Top: 1800 x 480. Madeof 18mm Thick (+1mm) PLB. Edge banded with matching PVC lipping.<br>Side Panel: 480 x 476. Madeof 18mm Thick (+1mm) PLB. Edge banded with matching PVC lipping.<br>Back Panel: 1755 x 470.Made of 18mm Thick (41mm) PLB. Edge banded with matching PVC lipping.<br>Sliding Door Panels:Made of 18mm Thick (+1mm) PLB. Edge banded with matching PVC lipping.
Supplying and Installing SENATE CONFERENCE TABLE WITH WIRE MANAGERor equivalent, sizeshall be Single seater 760 Width mm x 600 Depth mm , Two seater 1360 Width mm x 600 Depth mm ,Half Round (2 Seater ) R 713 + Quarter Round ( 1 Seater ) R 713 . The top shall be 31.6 mm thick (18mm + 12 mm + 0.6 mm DL ( both sides ) + 0.4 mm Membrane ) Edge Profile shall be waterfall edge 10mm radius on top edge and 5 mm at bottom . In Understructure the Legs shall be made from 25 mm PPBhaving a straight profile with half round edges and clad with 0.6 mm thick post Forming laminate . Overallthickness of leg shall be 26.2 mm The modesty panel in understructure shall be mae from PLT ( Prelaminated twin) boards of 18 mm thick . There shall be Wire Management wire carrier shall be made from0.6 mm thick CRCA painted and carrier cover shall be made of 12 mm thick MDF painted all over.
Supplying and installing PISA CENTER TABLE or equivalent-This should be a center table glass : itshould be 12 ±0.3 mm thick black tinted toughened glass uv glued with bushes made in ss 202 grade forfixing with understructure. pshould be a center table understructure : it should be a welded assemblymade in ss202 grade having dia. 12±0.04 as per should be :1762. Width of table= 112.0 cm, Depth=60.0cm, height=35.1 cm.
Supplying and installing PISA 3 SEATER or equivalent-with seat foam: the seat should be made of pufoam with density 32 ± 2 kg/cu.mtr having an additional top layer of j pu foam with density 28 ± 2 kg/cu.seat should be upholstered with fabric or leatherette. 2) back foam: the back should be made of pu foamwith density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 23±2 kg/cu. mtr,upholstered with fabric or leatherette understructre : understructure should be made up of 1.2±0.1 cm.thick hot pressed plywood ocp-qlta-pl14-18 4. dia 4mm zigzag spring assembly should be mounted inunderstructure for support and additional cushioning purpose leg assembly: it should be a weldedassembly made in stainless steel (grade ss 202) tube & plate.Width (W): 205.5 CM. Depth (D): 92.0 CM.Height (H): 82.0 CM. Seat Height (SH): 45.0 CM.
Supplying and installing CABIN TABLE - WISH or equivalent -52mm panel comprises of - 1) 2nos. Ofvertical trim made of aluminium extrutions. 2) Horizontal trims made of aluminium extrusions at everydivision of tile/block. The number of these horizontal trims vary as per panel height. 3) Blocks made out ofa composite construction of MDF and paper honeycomb. Numbers of these blocks vary as per panelheight. 4) 1no of fabricated bottom frme as welded structure of steel components. 4) 1 no of fabricatedbottom frame as welded structure of steel components. 5) 2nos of bottom tiles. 6) 2nos of top tiles. 7) 1noof top trim made of aluminium extrutions. 8) These panels are supported on legs with levelers at variouslocations depending on the layout requirements.
Design, Engineering, Drawings, Supply, Erection, Installation & Commissioning and training of 80 KLD Effluent Treatment Plant with all Electromechanical equipment as complete as required as per tender technical sepcification for the Development works for Rice Technology Park at Palakkad
Lee Builders
Vellapally Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid