| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹38.8 L+₹36,255.02 (0.94%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹44.5 L+₹6.1 L (15.9%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹45.0 L+₹6.5 L (17.0%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹45.5 L+₹7.0 L (18.3%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Feb 2021, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-55/2020-21 MANNING AND OPERATION OF DG SET INSTALLED AT ZONE A AT AF STN AMBALA UNDER GE AF AMBALA
2021_MES_415862_1
GE AF/AMB-55/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹90,000
Yes
8 Jun 2021
25 Jan 2021
1 Mar 2021
25 Jan 2021
26 Feb 2021
13 Feb 2021
1 Feb 2021 - 5 Feb 2021
Amount
PART-I (M&O WORKS)
Manning & Operation of substation with 1No. DG set 160kVA (make Cummins) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for GCA power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 160kVA (make Cummins) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for base OPs power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 75kVA (make Cummins) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for CRRW/AFNET complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substations with DG sets 1No. 160kVA (make Kirloskar) at 14Sqn new DSS, 1No. 100kVA at 14Sqn (make Crompton Greaves), 1No. 200kVA at 14Sqn Reccelite building (make Cummins) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 400kVA (make Crompton Greaves) by providing 01 (one) skilled FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for 27 MMPU complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Notes for serial item Nos. 1.00 to 6.00: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) The minimum wages as derived by the Department including all statutory provision such as EPF, ESIC, Bonus, GST, etc. as applicable except the Contractor's profit for skilled FGM/ person works out to Rs. 765/-per person per shift (iii) Bidder has to upload an signed undertaking in firm's letter head confirming that he has not quoted his rates lower than the derived minimum rates of the Department. Bids not accompanied with such undertaking shall not qualify for opening of the price bids. As applicable, his tender will be treated as 'NON BONAFIDE' if found at any stage and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only
Notes for serial item Nos. 1.00 to 6.00 contd: (iv) However increased minimum fair wages as notified time to time by the Government of India / State Government / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, irrespective of derived minimum wages as above (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase shall be passed over to the workers (vi) Rates quoted by the bidder shall be deemed to be inclusive of any extra manpower required (if any) for relieving, replacement, etc. and all stipulations as per tender documents (vii) The operator placed shall be responsible to attend complaints concerned to the location/s as directed (viii) Conveyance/vehicle for moving around of the staff employed and or any T&P required and detailed specifics as per particular specifications shall be provided by the Contractor. (ix) A penalty of Rs. 500/- per complaint shall be imposed on non-attending of such complaints as directed. Such penalties shall be recovered immediately from corrosponding RARs/FB of the Contractor.
PART-II (REPAIRS & OTHER WORKS)
Surface excavation not exceeding 30cm deep and averaging 15cm deep in soft / loose soil and getting out including taking out roots, shrubs etc, complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
M&L for removing vegetation of any type, including roots from surrounding areas of sub-stations, etc. by manually digging carefully and levelling the disturbed surfaces and spraying with and inlcuding Herbicide chemical (GLYPHOSATE 41% SL) with spray machines to stop further vegetation growth with all required tools / machineries, etc. complete all as specified and as directed
M&L for taking out 40/20mm graded stone agregates from inside of substation / fenced areas, screenig, cleaning with water and re-spreading and levelling in same areas to required thickness complete all as specified and as directed
Supplying and spreading 40mm graded crushed stone aggregates, levelling in layers not exceeding 150mm thick around transformers / LT panels, etc. at sub-stations / installations complete all as specified and as directed
Supplying and spreading 20mm graded crushed stone aggregates, levelling in layers not exceeding 150mm thick around transformers / LT panels, etc. at sub-stations / installations complete all as specified and as directed
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
M&L for dismantling and disposing off existing unserviceable earthing at any location and in any position complete all as specified and as directed
M&L for dismantling rusted / damaged fencing of any size / type from any height and disposing off complete all as specified and as directed
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed
S&F in repairs cable path indicator made out of MS sheet 3mm thick of size 300x250mm spot welded with angle iron of size 40x40x5mm thick 750mm long embeded in PCC 1:3:6 type C1 including painting with two coat of synthetic enamel black paint over a coat of red oxide primer and sign writing with white paint showing grade of HT/LT cable and size complete all as specified and as directed
Supply and lay / fix rubber matting chequered sheet of size 1.0x2.0m, 19mm thick, heavy duty, conforming to relevant IS, electric shock proof suitable for 11kV complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, bolts, nuts and screws type 410 SP-31, 9m long with detachable bracket arms including two coats of silver paint over shop coat of primer complete all as specified and as directed
S&F factory fabricated feeder pillar box cubical type, powder coated, of size 900x900x900mm suitable of 3 phase 415V outdoor type fabricated out of 3.15mm thick MS sheet and 40x40x6 angle iron frame, with suitable 1100V aluminium busbar 4Nos. for 3 phase system, front & rear openable type, PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4, 500mm in depth, type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer (on exposed surfaces of legs) provisioning of cable glands incoming 1No. and outgoing 1No. and taking down and disposing off old feeder boxes complete all as specified and as directed
M&L for hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh, etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
S&F MS XPM (expanded metal), not exceeding 4kg/sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed to wood or steel members complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
M&L for plain cement concrete type B-1,1:2:4 (using 20mm graded stone aggregates) in copings to poles, padding, PCC bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, etc. including necessary formwork complete all as specified and as directed
M&L for preparing of old steel surfaces of fencing posts / MS flats, welded mesh, XPM jalli, etc. over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of old steel surfaces of any description over 10cm in width or girth and applying two coats of aluminium paint complete all as specified and as directed
S&F 1.5m long 40mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including 2Nos. FI 50x6mm clamps as required to fix on concrete / steel poles and taking down and disposing off old unserviceable brackets complete all as specified and as directed
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V (earthed) grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. from any location and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
Supplying, fixing / laying in repairs PVC insulated copper conductor cable, 2 core 2.5sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in connections complete all as specified and as directed
S&F in repairs energy efficient LED Flood light fitting 70W and input voltage 230V, AC, 50Hz with ingress protection IP-65 with CRCA housing including fixing arrengment like clamps, nuts, bolts and washers, fitting shall have PF>0.9, input voltage 90-300V, IP-68, LM 80 stranded luminaries efficiency 100lumen/watt complete all as specified and as directed
S&F in repairs galvanised iron strip of size 32x6mm buried in ground / laid in ducts / fixing along walls, etc. including necessary saddles, nuts, bolts, etc. as required complete all as specified and as directed
S&F in repairs galvanised iron strip of size 25x3mm buried in ground / laid in ducts / fixing along walls, etc. including necessary saddles, nuts, bolts, etc. as required complete all as specified and as directed
S&F in repairs LED light fittings 90W, input 110V to 280V, with auto shut down on high voltages, life>50000hrs, operating temperature 1oC to 50oC, protection class IP 65 street light, luminaries comprising of rectangular shape pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of min 5000 lumens with 120 degree view angle, the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10kV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 i, fitting having PF >0.9, input voltage 90-300V, IP-68, LM 80 stranded luminaries efficiency 100lumen/watt complete all as specified and as directed
S&F in repairs thermoplastic cable junction box with 02Nos. PVC gland, weather proof, IP 66/67 protection class, for outdoor installation with knock outs for cable entry of size 300x250x200mm hinged type with 4Nos aluminium bus bar of size 25x6mm and 8Nos. terminals with all required nuts, bolts, mounted on bus bars and connecting up with existing cable and duly fixed with MS clamps made out of FI 40x3mm thick with nuts & bolts as required complete all as specified and as directed
M&L for earthing using GI earthing strip 32x6mm with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
M&L for bore earthing by making bore 20 feet deep and 150mm dia manually with help of augar (Boki) including provisioning of 40mm dia medium grade perforated GI pipe bolted with GI strip 32x6mm from bottom of pipe upto test point, filling around pipe with 6 inch dia & 150mm thick alternate layers of charcoal dust & salt, with funnel and wire mesh, PCC 1:3:6 type C1 in chambers, RCC 1:2:4 type B-1 in pit cover reinforced with 8mm dia deformed bars @ 150mm c/c both ways including necessary excavation & earthwork, all as shown in electric plate No. 3 of MES Sch Part-I of 2009, PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering complete all as specified and as directed
Notes for serial item Nos. 46 & 47: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
MAHESH GAUR AND CO.
Swami Engineers
Esha Engineers
M/S Sonu Traders
m/s parmod kamar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .