Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹39.0 L+₹1.2 L (3.12%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹40.2 L+₹2.4 L (6.27%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
30 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
PROVN OF CRECHE, PROVN OF RCC JAIL WALL AROUND THE OFFICERS RESIDENTIAL COLONY, PROVN OF BUILDING NEAR MAIN GATE FOR INSTALLATION AND OPERATION OF SECURITY GADGETS AND PROVN OF POL ROOM AT NAD BHEEMUNIPATNAM UNDER GE(P) NAVY KALINGA
2021_MES_492056_1
GE (P)/N/K/8846 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹87,200
Yes
24 Mar 2022
2 Dec 2021
1 Jan 2022
2 Dec 2021
30 Dec 2021
16 Dec 2021
60 days
Amount
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard / dense soil.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc.
Plain cement concrete (1:3:6) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft /loose soil.
Removing excavated materials (soil) exc 250mm and n. exc 500m and depositing where directed at a level n.exc 1.5m above the starting point.
Treating the backfill in contact with the foundation at the rate of 7.5 Ltrs of anti termite emulsion per Sqm of vertical surface.
Treating the top surface of filled earth @ 5 ltrs of emulsion per Sqm of surface area.
Treating the soil under plinth protection @ 5 ltrs of emulsion per Sqm of surface area.
Treating the soil along with external perimeter of building @ 2.25 ltrs of emulsion per meter of the perimeter wall.
Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in foundations, including rafts, footings, plinth beams, bases for columns, basement slab, under-reamed piles etc..
Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in columns, pillars, piers, posts etc.
Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in beams, cantilever, bressumers, lintel over 1.5 mtr span etc.
Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in slab supported on walls and the like.
Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in chajja and the like etc.
Precast Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab for manholes, landings, shelves and similar articles etc set in CM 1:4.
Use and waste of formwork to sides of foundation/ footings, plinth beams and similar work for rough finished surfaces.
Use and waste of form work to sides of columns, pillars, posts, struts, piers and stanchions etc for fair finished surfaces.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work, not exceeding 200mm thick for fair finished surfaces.
Use and waste of formwork to chajja and similar items including edges.
TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including cranking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
TMT bars 6 to 8mm dia cut to length, bent to shape required including cracking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required including cranking bending hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips.
Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:6).
Brick work with sub class 'B' bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:4).
Brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4.
Earth filling in floors or pavings, laid in layers n exc 15 cm thick spread, levelled and rammed including watering.
Hardcore of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface,.
75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base/ floor/ plinth protection etc,.
25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floors.
Non skid/matt finish ceramic tiles 7mm to 8mm thick area of each tile exc. 0.18 Sq.m. but n. exc. 0.38 Sq.m., in floors etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finishes.
Non skid/matt finish ceramic tiles 7mm to 8mm thick size of each tile 600mm X 600mm, in vertical surfaces(skirting) etc. set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 10mm thick in CM 1:3 for laying floor finishes.
Glazed ceramic coloured tiles 250 x 450 x 7 mm/ 300 x 450 x 7mm thick (Ist quality) conforming to IS-13753, as in vertical surface such as skirting/dado set in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick rendering to receive tiles in CM (1:3) finished even and rough.
20 mm thick granite (of any type) work table rubbed and polished in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20 mm thick screed bed in CM 1:4.
Rendering 10mm thick on internal surfaces of brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in two coats, first coat shall be 10 mm thick in CM 1:6 and second coat shall be 5 mm thick in CM 1:4, mixed with water proofing compound as per manufacturer's instructions in the outer layer finished even and fair. Note: WPC will be measured and paid separately as supply only
Rendering 5mm thick in cement plaster on ceiling in cement mortar (1:3) finished even and fair.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
Applying two coats of oil bound distemper over a coat of primer including preparation of new plastered surfaces of walls.
Applying two coats of weather shield exterior emulsion paints over a coat of primer including preparation of new plastered surfaces of wall.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash.
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, (minimum thickness of powder coating 50 micron).
Powder coated anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door, hinges anodised aluminium snap beading, screws etc (thickness of powder coating not less than 50 micron).
Anodised powder coated aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron).
Solid PVC door frames of size 50mm X 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain color PVC ‘C’ channel having a PVC strip of 20mm width stuck inside with solvent cement for stiles & plain color PVC sheets for top rail, lock rail & bottom rail on either side & gap insert for top rail & bottom rail, paneling of plain color PVC sheet to be fitted in the MS frame, welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent.
100mm size butt hinges, medium weight, stainless steel.
150mm size aluminium handles, cast type, anodised.
150 mm long, aluminium alloy barrel tower bolts anodised extruded section ISI marked.
300mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy.
Wash hand basin vitreous China white coloured flat back/ angle back of size (550x400)mm including a pair of bracket and waste coupling and cutting for pinning in ends of brackets.
1mm thick stainless steel kitchen sink with drainage board of 915mm x 460mm over all size and 410 x 330 x 160 mm bowl size with plugs wastes and washers including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe.
Grating doom 125mm dia of PTMT approved quality (minimum weight 40 gms).
Vitreous china squatting Pan "Orissa" pattern size 580 x 440 mm white with integral foot rest, connecting to trap including provision of cement concrete bedding including connections to flushing cistern and flush pipe, anti syphonage pipe etc.
10 Ltrs (PVC) white, valve less, syphonic action type, dual type flushing cistern, low level with inlet ball valve, float, top push button type and 32 mm dia flush pipe.
15mm dia pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts. Screwed for iron pipe.
PVC connection 15mm size with PTMT nuts of length 450mm.
15mm dia angle valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions.
15 mm dia two way bib cock chromium plated fancy type.
15mm bore Health faucet with 1.5m long easy flex tube in chrome finish and wall hook,.
PP-R ball valves (brass insert) suitable for 25 mm bore PP-R pipe including connection & testing.
PP-R gate valves (brass insert) suitable for 25mm bore PP-R pipe including connection & testing.
25mm outer dia. 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc..
16mm outer dia. 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc..
15mm thick screed bed on concrete surface in cement mortar 1:3 with water proofing compound before carrying out water proofing treatment over roof slab. Note: WPC will be measured and paid separately as supply only
APP based polymeric membrane minimum weighing 3 Kg/Sq.m. and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/Sq.m.) laid on primed surface after applying a coat of blown bitumen 85/25 grade @ 1.20 Kg/Sq.m. over bitumen primer @ 0.50 Kg per Sq.m. by forced application, applying another coat of hot blown bitumen 85/25 grade @ 1.20 Kg per Sq.m. over water proofing membrane and applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg per Sq.m. all as per the manufacturers instructions.
75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection/ sub base and paving finished cement concrete surfaces even and fair without using extra cement.
40mm PVC (SWR) pipes single socketed in any length with rubber ring jointed to wall.
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls.
PVC (SWR) pipes 150 mm dia single socketed in any length with rubber ring joints laid in trenches.
PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm dia drain pipe.
110 mm bore PVC (SWR) bends any radius with access door.
PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls.
PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints laid in trenches.
75 mm bore PVC (SWR) bends any radius with access door.
75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement.
PVC (SWR) gully trap 110mm square or round mouthed type 'S' setting and jointing with solvent cement .
PVC (SWR) vent cowl 110mm bore.
4mm thick figured glass, pin headed type & glazing with oil putty in square not exc. 0.5 sqm in each pane.
4mm thick sheet glass, pin headed type & glazing with oil putty in square exc. 0.5 sqm in each pane.
5.5 mm thick sheet glass, ordinary quality and glazing with oil putty in square exc. 0.5 Sq.m. in each pane.
12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber/ aluminium frame work.
Anodised coloured aluminium grill of design No.DG-117, 10mm thick of DECOGRIL or equivalent make as approved by GE fixed with and including 'F' sections.
Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples.
Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) Conforming to IS 12701-1996 hoisted and fixed in position 500 ltrs capacity complete all as specified in SSR Part I .
Cutting into existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 110 mm bore drain pipe.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft / loose soil.
Reinforced Cement Concrete,1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in foundations, including rafts, footings, plinth beams etc and the like.
Reinforced Cement Concrete, 1:1.5:3, type A1 (Using 20mm graded granite stone aggregate) in columns, pillars, piers, posts and struts etc and the like.
Reinforced Cement Concrete 1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in beams, cantilevers, lintels over 1.5 m span etc and the like.
Removing excavated material from site to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point.
Providing cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as cast in situ in lintels upto 1.5m span, cills and other similar bands, plinth courses, parapets, railings upto 60 cm height, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating.
Rendering 10mm thick on fair surfaces of brick wall or concrete surface in cement mortar 1:4 finished even and fair without using extra cement.
Preparation of new external surfaces of walls and applying two coats of cement based paint over a coat of primer.
Providing precast cement concrete type B-0 (using 12.5 mm graded aggregate) as in louvers and jallies, 50mm thick (measured solid), set in CM 1:4 including all mouldings.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in natural ground and making good disturbed ground
Dismantling of barbed wire fencing in position.
Boulder pitching, laid dry, hand packed tightly and grouting with cement sand mortar 1:4.
Non skid/matt finish ceramic tiles 7mm to 8mm thick area of each tile exc. 0.11 Sq.m. but n. exc. 0.18 Sq.m. (400 mm x 400 mm size), in floors etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finishes.
Non skid/matt finish ceramic tiles 7mm to 8mm thick of size 400mm X 400mm, in vertical surfaces(skirting) etc.set and jointed in neat slurry and pointed in white or coloured cement to match for tiles over backing coat of 10mm thick in CM 1:3 for laying wall tiles.
Brushing neat cement slurry with 3.0 kg of cement per sqm.
2nd class hard wood (well seasoned) plain, solid, straight, chowkats and frame, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
35mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces and size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated.
200 mm long, aluminium alloy barrel tower bolts anodised extruded section ISI marked.
125mm size MS butt hinges medium weight cold rolled fixed to frame.
Preparation of new wooden surface of any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint first grade quality over a coat of pink primer,.
50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors finished even and smooth without using extra cement.
Glass dividing strips 3 mm thick & 38mm wide inserted in position conforming to design .
Sand filling over/ under floor or in foundations including watering and consolidation/ sand cushioning for protection of underground cable consolidated and compacted with dry clean sand.
100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors finished with using spike roller for making impression of expanded metal while the concrete is green .
Preparation of new plastered surfaces of walls and applying three coats of white wash.
40 mm thick damp proof course in 1:2:4 type B-0 using 12.5 mm graded aggregate to horizontal or vertical surfaces including necessary formwork.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil.
Point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes , concealed type with 2 mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface.
All as per Item no 115 above but for one 3 pin switch socket outlet, 5 Amp on independent board.
All as per Item no 115 above but for one ceiling fan/ exhaust fan controlled by one way switch.
All as per Item no 115 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 115 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4.0 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire.
Switch piano flush button single pole one way 5 amps.
Switch socket outlet with indication lamp 3/ 5 pin 5 amp flush type with incl switch .
Socket out let multipurpose with indication lamp 3 pin 15 amp and one 3 pin 5 amp controlled by and including one 15 amp switch.
Ceiling rose surface bakelite 65 x 50 mm, three terminals.
Fan regulator electronic deluxe rotary step type.
Sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface. NOTE: 3 runs of 4.0 Sqmm and one run of PVC concealed conduit 25 mm dia will be measured as one unit i.e. RM
Sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar, .
MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position,.
MCB double pole of capacity up to 40 amps, 240 Volts C-series with 10kA breaking capacity, .
Surface mounting luminaries LED downlighter of 12 watt white shape of square 1'x1'. Make Havells Cat No. LHEAAWP6IL1W012 or equivalent as approved by GE
Indoor luminaries decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector. (CG Cat Part no. CCS-100-20-65-HL2-DP-NWH or equivalent as approved by GE)
Lamp holder insulated body suitable for Retrofit lamp.
LED security light fitting luminaries 1X25 W and including cable for connection from ceiling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt,nut,washer,clamp etc. Make CG Cat Part No. LSTS-25-CDL/NL-M or equivalent as approved by GE
Ceiling fan 1200mm sweep, decorative blades pearl white BEE 5 star rated with high air delivery at low voltages, with double ball bearing in ivory gold/white colour including down rod of 19mm dia 300mm long and connecting up with flexible 3 core 1.5sq.mm twisted copper cable from terminal point to ceiling fan. (Havells Cat Part No. ES 40 or equivalent as approved by GE)
Exhaust fan wall mount type 300 mm sweep metal body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6).
Wall mounted Air circulators fans PVC body 400 mm sweep 230 volts SP complete with accessories.
XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trench /poles/on wall.
Laying bricks common burnt clay building bricks sub-class B of size 230x115x75 complete all as directed by Engr-in-Charge.
Boring of holes under road, pavement hard standing by trenchless technology using ultrasound technology & necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 Mpa working pressure.
Galvanized iron tubing 25 mm bore light grade with all fittings for protection of FRLS cable, laid in trenches/wall/floor including necessary clamps, bolt/nut. Note: Earth work excavation will be measured and paid separately.
AC single phase static Electronic KWH energy meter of accuracy class 1.0, 240 volt, 50Hz, with backalite LCD Display, of rating 10-60A with transparent hinged type Box with six month History of energy in KWH with taking down old meter and kept in MES store yard with accessories. Make L&T Cat Part No. WM101BC7DDH or equivalent as approved by GE
Earthing complete with 7.5m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 2.5mtrs length buried directly and preferably vertically in ground with top flanged ended 2.5mtrs below ground level welded/ connected with GI strip 32×6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore in any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab and necessary testing on completion. .
Concealed point wiring complete with 2.5 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade conforming to IS drawn through and including suitable dia PVC conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc with 2.5 Sqmm copper earth wire for earth continuity conductor and connection to common earth dolly for 15 Amp socket on independent board.
Surface point wiring complete with 1.5 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto light fittings/ fan with 1.5 Sqmm copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for one light/ fan point controlled by one flame proof rotary one way switch.
Surface point wiring complete with 4.0 Sqmm PVC insulated unsheathed FRLSH cable multi stranded copper conductor 1100 volt grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed in surface of wall/ ceiling/ floors etc for flameproof application connected upto power switch socket with 4.0 Sqmm copper earth wire for earth continuity conductor and connection to common earth dolly and to be terminated for one 3 pin power socket controlled by one 16 Amp one way switch.
Flame proof junction boxes LM-6 2/3/4 way suitable for 20 mm dia ERW steel conduit complete certified by CIMFR for Gas group I, IIA & IIB for zone I & II.
Sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6.0 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface. NOTE: 3 runs of 6.0 Sqmm and one run of PVC concealed conduit 25 mm dia will be measured as one unit i.e. RM
XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trench /poles/on wall.
Single pole and neutral enclosure with two pin earth plug with 01 Nos of MCB SP 20 Amps 'C' series.
Flame proof rotary switch socket and plug combined with separate cable terminal box including rubber gasket as per IS 2149, SP 16 Amps, 2 pole+earth, 250 volt ISI marked for power ON/ OFF, made out of aluminium alloy LM-6 marked in high tensile steel with anti corrosive epoxy paint grey shade CMRI certified with cable entries.
LED tube light 20 W, 230 V, 50 HZ including LED light driver holder connecting up with three core flexible copper conductor of suitable size upto ceiling rose.
LED light fitting 2 x 16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , triple pole and neutral (TPN) 240 Volt , double door, suitable for 5 way with din rail earth and neutral bar.
Note : 1. All items in the schedule shall be read in conjunction M&L or S&F as applicable. 2. All items in the schedule shall be completed in all respect as directed by the Engr-in-Charge.
SWATHI CONSTRUCTIONS
SRI GOWRI ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .