Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.4 L+₹90,459 (9.56%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹13.3 L+₹3.8 L (40.3%)Rejected-Finance 81 INDRA COLONY JAISALMER 345001 RAJASTHAN | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
4 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Maint/Repair of certain building at Air Force Station Ramgarh under (AF) Jaisalmer
2021_MES_493884_1
8797/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
₹20,000
Yes
15 Mar 2022
10 Dec 2021
6 Jan 2022
10 Dec 2021
4 Jan 2022
22 Dec 2021
11 Dec 2021 - 15 Dec 2021
60 days
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
Vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement and sand mortar 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified.
Vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved) on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
Coloured glazed ceramic tiles 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement and sand mortar (1:4) including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
Coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc over 15mm thick in cement and mortar (1:6) bedding set and jointed in neat cement slurry and pointed in coloured cement to match including dismantling floor, hearth or wall tiling cement mortar bedding complete all as specified and directed
Taking down PVC door chowkhats or frame with shutters (without taking off shutters from the frames), area not exceeding 1.5 sqm each complete all as specified.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames), area exceeding 1.50sqm but not exceeding 4.00sqm each complete all as specified and directed.
Powder coating standard anodised aluminium extruded sections as in frames for chowkats, doors, windows shutters with style and rails or for fixed glazed partitions wall frame made to shape required fixed with 150mm long screw and rawl plug with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing for fixing, anodised aluminium snap beading screws etc complete all as specified and directed.
Anodized aluminium sections as in window and ventilator shutters, side hung type without sash bars (aluminium sections weighing 0.55 kg/m) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (01 Nos each shutter), extruded anodised aluminium alloy with galvanised mild steel hinge pin, 100mm long (03 Nos each shutter), extruded anodised handle of suitable type (01 No. each shutter) etc. complete all as specified and as directed.
Figured glass 4.8mm thick (Tinted) pin head type and fixed as window/ventilators and glazing with oil putty or aluminium beads and rubber in square exceeding 0.5 sqm in each pane complete all as specified and directed.
Factory made 30mm thick flush shutter, solid core construction, with block boards core and plywood face panels, commercial type on both sides (ISI Marked) fixed to chowkhats complete all as specified and directed.
Wood grain printed 1mm PVC sheet fixed or laid on to flush doors by using rubber based adhesive, supplying & fixing at site as per specification complete all as specified and directed.
Stainless steel Butt hinges, 100mm long complete all as specified and directed.
150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
Brass handle 125mm long cast type, anodized complete all as specified and directed
250mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed
Aluminium extruded section body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851-1000mm in width & weight between 61 to 80 Kg, complete all as specified and directed.
Galvanized, corrugated mild steel sheet 0.63mm thick with two corrugation side lap, fixed with L-type or J-Type or cranked hook bolt and washers as in wall claddings etc. with grade of Zinc coating 275, including dismantling of old unserviceable sheet complete all as specified & as directed.
Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface any type of soil complete all as specified and directed.
PCC (1:2:4) Type B-2 (using 40mm graded stone aggregate) as in foundations for filling & mass concrete complete all as specified and directed.
Rolled mild steel work as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410) quality 'A' complete all as specified and as directed.
Steel work in tubular pipes stanchions, purlins including special shaped , including special shaped washer etc. complete using or including butt welded tuber cum forming to IS 1161-1979 grade st-240 complete all as specified and as directed.
Prepariation of newly steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Wind ties for including securing bolts, including all necessary drilling, bolting or riveting, and similar work conforming to Gde E-310 (Fe-410) complete all as specified and directed.
Anodized aluminium snap grid frame work for false ceiling as per manufacturer's instructions with hangers from RCC soffit/steel trusses with 6mm dia GI rod (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long with including exposed metal frame ceiling with 12mm thick gypsum board for ceiling fixed with screws as per manufactures instructions including taking down/dismentling of false ceiling boards complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 500 Litre capacity triple layered white (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including taking down existing water storage tank complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 Litre capacity triple layered white (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including taking down existing water storage tank complete all as specified and directed.
Ball valves, high pressure of PTMT (Polytetra methylene terephthalate) with epoxy coated aluminum rod & high density plastic ball and fly nut, screwed for iron pipe 20mm dia (minimum weight 210 gms) fixed as in repair complete all as specified and as directed.
Vitreous china urinal, half stall type, white coloured, including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs and including 60mm long brass screws, pointing around urinal back in cement, with and including grating and union for discharge pipe, including 40mm size brass chromium plated waste coupling with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed as repair complete all as specified.
Flushing cistern PVC capacity 10 Litres valve less syphonic action type, low level, white coloured, with inlet, ball valve, float and handle including brackets complete with flush pipe fixed as in repair complete all as specified and directed.
40mm bore of pipe Low Density Polythylene Pipes (LDPE) with fittings as required of pressure rating 6 kgf/cm2 and fixed complete to walls, ceilings or in floors etc. fixed as in repairs complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls or concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
10mm thick plaster in cement and sand mortar (1:6) on concrete surfaces or masonry surfaces as in manholes, gully traps and finished even and smooth without using extra cement complete all as specified and directed.
5mm thick internal plaster in cement mortar (1:3) on uneven surfaces of concrete with wall care putty smooth finished surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
Dubbing out in cement and sand mortar (1:6) average 10mm thick on irregular face of walls/ceiling complete all as specified and directed.
Preparation of newly treated/decorated external wall/roof surfaces of any storeys/height upto 10m of any description and applying two coat of exterior emulsion paint (weather coat) over a coat of primer 1st quality in different tints/shades in sigma/camouflaging pattern as approved complete all as specified and directed.
Preparation of newly plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered surfaces or unplastered surfase of walls and applying two coats of oil emulsion distemper over a coat of cement primer in different tints/shade in sigma/camouflaging pattern as approved complete all as specified and directed.
Preparation of old decorated surfaces of wall by washing, rubbing down and stopping of painted sufaces and applying one coat of oil emulsion distemper of any tint etc complete all as specified and directed.
Preparation of old decorated surfaces of ceiling surfaces by washing, rubbing down and stopping of painted sufaces and applying one coat of oil emulsion distemper of any tint etc complete all as specified and directed.
Preparation of old treated/decorated wall/roof surfaces height exceeding 10m but not exceeding 20m and description and applying ono coat of exterior emulsion paint (weather coat) 1st quality in different tints/shades in sigma/camouflaging pattern as approved complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
75mm thick Plain Cement Concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as floor and plinth protection, finishing surface even and smooth without using extra cement complete all as specified and directed.
Providing Precast Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate as in landing cover slab (for manholes) and similar articles with plain faces including use and waste of formwork as required and set in cement and sand mortar (1:6) and including demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed
Mild steel TMT bars upto 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Precast cement concrete (1:3:6), type C-1 (using 20mm graded stone aggregate) as solid block masonary exceeding 10cm and set in cement and sand mortar (1:6) complete all as specified and directed.
PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) as in foundations for manholes complete all as specified and directed.
Plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in surfaces channels, drains and benching for manhole and finishing of exposed surfaces of concrete complete all as specified and directed.
Providing cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in cill, step and for inserting hold fast of door & window, coping of masonry wall including weathering, slightly rounded or chamfered angles and throating, necessary formwork as required complete all as specified and directed.
15mm thick plaster in cement and mortar (1:6) on stone masonary surface on other than fair face of brick work or concrete surfaces or stone masonry surfaces of wall, complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150mm bore pipe complete all as specified and as directed.
150mm bore reinforced concrete pipe, class NP2, laid and jointed complete with collars, laid and jointed on concrete bed complete including testing, after demolition and breaking up drain pipes set in cement mortar complete all as specified & as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching, for removing existing branch drain, making good to walling and rendering, cutting out branch channel, and making good benchings; Internal diameter of pipe 150 mm complete all as specified.
Cleaning and desilting of manhole of any size and capacity or description upto 1.00 metre deep by excavation sewage wet/dry soil in foul condition and removing the waste in covered vehicles (van/trolley) outside the MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manholes, placing the cover of manholes in position and removing the sludge in covered van/trolley out side in MD land complete all as specified and directed.
Cleaning of sewage line of 100/150/200mm bore by roding and flush water in line after roding to clean the line complete all as specified and directed. Note : The contractor shall arrange safaiwala immediately as receipt of complaint and ensure that complaint is resolved within 24 hours and no lapses will be allowed.
Cleaning of septic tank/soakage well upto 25 users capacity by balling out taking out sludge and removing the sludge to a distance exceeding 1.5 Km but not exceeding 2.00 Km from the camp area and including removing stone patti/RCC cover slab and refixing the same position complete all as specified and directed.
Cleaning of septic tank/soakage well upto 10 users capacity by balling out taking out sludge and removing the sludge to a distance exceeding 1.5 Km but not exceeding 2.00 Km from the camp area and including removing stone patti/RCC cover slab and refixing the same position complete all as specified and directed.
Removal of blockage in between WC and nahani trap/WC to Ist manhole / floor trap to nahani trap etc. by flexible roding and removal the all dirt up to a distance of 100 metre complete all as specified and directed. Note : (i) In case a blockage reoccured with in 7 days the same shall be removed without any extra cost of the Govt. (ii) Cleaning of line in between manhole where in the blockage remove shall deemed to incl the rate coated. (iii) If contractor failed to clear the blockage with in 24 hours from the receipt of complaint, a penalty of Rs. 50 per day will charge up to 7 days and after 7 days same will be Rs. 100.00 till completion of complaint.
Stop valve with 15mm bore (concealed type) cast copper alloy chromium plated screwed down, high pressure, screwed both ends for iron pipe or for union fixed as in repair complete all as specified and directed.
15mm bore fancy type chromium plated pillar taps with capstan heads, screwed down high pressure with long screwed sharks and fly nuts screwed down for iron pipes etc and fixed as in repair complete all as specified and directed.
15mm bore chromium plated Bib taps fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repairs complete all as specified and directed.
Galvanized steel water tubing medium grade of 15mm bore with & including all fittings fixed to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
Galvanized steel water tubing medium grade of 20mm bore with & including all fittings fixed to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
PVC connection suitable for 15mm bore with PTMT nuts of 450mm length and including taking down old unserviceable complete all as specified and directed.
Waste coupling of PTMT (half or full threaded) (minimum weight 45gms) suitable for stainless steel sink 32mm bore pipe fixed as in repair complete all as specified and directed.
32mm bore of pipe Low Density Polythylene Pipes (LDPE) with fittings as required of pressure rating 6 kgf/cm2 and fixed complete to walls, ceilings or in floors etc. fixed as in repairs complete all as specified and directed.
PVC (SWR) floor trap 75mm dia outlet plain with grating including jointing with solvent cement and jointing to waste pipe fixed in cement concrete type B-1, 1:2:4 complete all as specified and directed.
15mm bore bib tap standard of PTMT any colour, high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) fixed as in repair complete all as specified and as directed.
15mm bore with long body bib tap standard of PTMT any colour, high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) fixed as in repair complete all as specified and as directed.
Swivel shower of PTMT any colour with shower 195mm long and 15mm dia pipe (Minimum weight 40gms) fixed as in repair complete all as specified and directed.
Peg set 6 (Zinc) fixed as in repair complete all as specified and directed.
Ball valves, high pressure of PTMT (Polytetra methylene terephthalate) with epoxy coated aluminum rod & high density plastic ball and fly nut, screwed for iron pipe 20mm dia (minimum weight 210 gms) fixed as in repair complete all as specified and as directed.
Shelf of PTMT fixed with and including chromium plated brass screws & wooden/plastic cleats (Minimum weight 300 gms) fixed as in repair complete all as specified and directed.
Liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) etc fixed as in repair complete all as specified and directed.
Tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges fixed as in repair complete all as specified and directed.
Stainless steel wire cloth 0.56mm nominal dia of wire and average width or aperrture 1.18mm and fixed with tinned tackles or stainless steel wire staples fixed as in repair complete all as specified and directed.
3mm thick figured glass pin headed quality and glazing with oil putty/wooden beading not exceeding 0.50 sqm in each pane fixed any bldg height including hacking out old broken glass any thickness size, quality or description from wooden frame glazed with puty or fixed with beads complete all as specified and directed.
4mm thick sheet glass ordinary quality and glazing with oil putty/wooden beading not exceeding 0.50 sqm in each pane fixed any bldg height including hacking out old broken glass any thickness size, quality or description from wooden frame glazed with puty or fixed with beads complete all as specified and directed.
Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work confirming to Fe-290 Grade E-165 including dismantling structural steel work complete all as specified and directed.
Mild steel flat as in hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 including dismantling structural steel work complete all as specified and directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete of Gde E-165 (Fe-290), drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooken and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing in position including dismantling structural steel work complete all as specified and directed. Note : Cost of welding butt hinges to the door frame deemed to included in quoted rate and butt hinges shall be measured & paid for “Supply only” separately under relevant item of this schedule.
M/S Rana Enterprises
M/s PRABHU DAN DETHA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .