Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.9 L+₹7,850 (0.53%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance Being L2 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AT HARNI AIRFIELD AND HARNI CAMP AT AF STATION BARODA
2020_MES_403432_2
8592/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹28,000
Yes
23 Mar 2021
18 Jan 2021
4 Feb 2021
18 Jan 2021
1 Feb 2021
19 Jan 2021
60 days
Amount
Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 310/ 280 Ltr. Capacity with new uncut hermitically sealed compressor including suitable relay and over load with new sealed unit as per the company manufacturer complete all as specified and directed.
All as above item No 1.00 but for 165/ 170/ 180 Ltr capacity refrigerator.
Material and labour in replacement of relay suitable for 286/ 310 liters cap refrigerator as per existing make complete all as specified and directed.
All as above item No 3.00 but cap 165 Ltrs. Refrigerator
M&L in repair of thermostat automatic `R' frost with knob suitable for 165/286/310 liters cap refrigerator as per existing make complete all as specified and as directed.
M&L in repair of freezer assembly complete with screw, jointing of tubes etc. and testing of cap 286/310 Ltrs refrigerator (any make) complete all as specified and as directed.
All as above item No 6.00 but of capacity 165/175 Ltr refrigerator.
Material and labour in replacement of condensor unit of refrigerator cap 286/ 310 Ltrs jointing of tubes and testing etc complete all as specified and directed.
All as above item No 8.00 but for 165 ltrs capacity refrigerator.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with suitable refrigerant for up to 310 ltr capacity refrigerator complete all as specified and directed. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labor for replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
All as per ser item No.11.00 above but for 2 TR capacity Split / Window type AC
Material and labor for rewinding of blower motor of Speed 900 RPM of window/Split Air conditioner of capacity 1.5/ 2 ton any make with super enameled copper conductor including replacement of worn out bushes ,Shaft and capacitor etc complete all as specified and directed.
Labour only for attending complaints of Air conditioner carried out by manufacture's authorised mechanic from the servicing centre without any delay with rectified the defects by carefuly opening and check the ACs parts which defects find out at site and replace the defected parts from the ACs for smooth functioning complete all as specified and directed Note :- Supply only item shall be measure and paid seperately under respective item of BOQ
All as per item no 14.00 above but for AC plant of 22 TR Capacity
Supply only of following parts for Split type/window type AC 1.5 /2.0 TR
Condensor fan motor of outdoor unit as per existing capacity and existing make
Blower motor of indoor unit AC/ DC type as per existing capacity and existing make
Capacitor of capacity 50/45 MFD, 240 volts 50 cycles
Capacitor of capacity 55/60 MFD, 240 volts 50 cycles
Over load protector with relay
Thermostat switch for window type AC cap.1.5/ 2.00 ton capacity
Defective wiring set (with suitable copper wire)
Condensing fan motor blade of outdoor unit
Air filter 5 micron as per existing size
Expansion valve as per existing size
Blower for window type AC
Blower for split type AC
Sensor for indoor unit of split type AC
Contactor NO/ NC type as per existing
Evaporator Coil
PCB Card for split type AC of capacity 1.5 TR as per existing make and model
PCB Card for split type AC of capacity 2.0 TR as per existing make and model
PCB Card for invetor type AC as per existing make and model
Remote hand set for split type/window type AC 1.5/2 TR capacity
Valve 1/2 " ,1/4 " and 5/8 " for split type AC 1.5/2 TR capacity
Condensor unit of capacity 1.5/2 TR
Connector unit
Drainout Pipe of existing make
Swing motor of existing make
Mounting stand for outdoor unit split type AC
Note: fixing of supply only item shall be measured and paid under respective item of BOQ
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-22, R-401A oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton complete all as specified and directed.
Material and labour for servicing/ overhauling with chemical wash of split /Window type AC unit capacity up to 2.0TR complete all as specified and directed.
M&L in repair of copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
M&L in repair of copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
M&L in repair of copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
Material and labour for foam type insulating flexible pipe fitted on suction/ discharge copper tubes complete all as specified and directed.
Taking down carefully existing split type AC of capacity 1.5/2 TR (complete unit) and refixing the same from one site to another site as per users requirement complete all as specified and directed.
Material and labour for repairing of PCB of split type AC of capacity 1.5/2 TR soldering and brazing of circuit, including replacement diode IC complete all as specified and directed.
Material and labour for replacement of electrical sub main wiring two run of single core 2.5 sq mm (Nominal area) multi-threaded copper conductor PVC insulated sheathed cable including one run of 1.5 Sqmm solid copper conductor PVC insulated cable in and including 20 mm dial rigid metallic conduit complete including junction boxes with metallic sheet top cover and other accessories complete all as specified and directed. NOTE:- Two run of main wire, one run of earth wire and pipe shall be measured as one length.
Supply and fixing single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 20 Amps as in replacement complete all as specified and as directed.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland or existing make) Note:- i) Old sealed compressor received from the water cooler will be property of contractor ii) The rate quoted by the contractor includes all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition iii ) The new sealed unit will be purchased from authorized dealer/manufacturer.
Supply and fix in repairs of following parts for Water cooler for Storage Capacity 80 Ltr Cooling cap 40 Ltr/hr complete all as specified and as directed.
Copper filter and capillary tube of existing make
Relay with over load protectors.Make :- Ranutrol/ Rockwell/ Annapurna
Condensor fan of motor HP- 1/32 ,RPM-1300 with clips and motor fixing stand with fan blade of existing make
Thermostat switch with knob of existing make
Drip tray made out stainless Steel sheet.(as per sample kept in AGE E/M office)
Fan motor mounting stand as per sample kept in AGE E/M office
Push cock, 15mm bore (as per sample kept in AGE E/M office)
Running capacitor of 10 Mfd.
Starting capacitor 40/60 Mfd 240 volt AC Supply.
Fan blade for condensing fan motor
Condenser unit
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with suitable refrigerant, oil charging complete in compressor of water cooler having capacity 40 ltr per hour of existing make complete all as specified and directed & with entire satisfaction of Engineer-in-Charge. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with super enameled copper wire of suitable gauge including insulating material and replacement of gun metal bush & capacitor 2.5 MFD complete all as specified and directed.
S&F in repair of copper piping with fittings for hot gas line from package AC unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 5/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of copper piping with fittings for liquid line from package AC unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 7/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of cath all driers 5/8"x5/8" for package type AC complete all as specified and directed.
S&F in repair of ball valves 5/8" in liquid line for package type AC complete all as specified and directed.
Material and labor for replacement of unserviceable cut sealed compressor of package type AC plant 11TR capacity with new uncut sealed scroll compressor unit 11TR capacity supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, complete and testing after completion of work satisfactory functioning complete all as specified and directed. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-407C complete in compressor package type AC plant capacity 11TR Ton with entire satisfaction of Engineer-in-Charge complete all as specified and directed.
S&F in repair of motor protection device (MPD) rating 11 to 30 Amp with display suitable for package type AC of capacity 22 TR complete all as specified and directed.
Material and labour for servicing/ overhauling with chemical wash of package type AC capacity 22 TR complete all as specified and directed.
Material and labour for rewinding of blower motor of 5 HP 3 Phase 415 V package type AC capacity 22 TR with super enameled copper conductor including replacement of worn out bushes, Shaft etc and testing complete all as specified and as directed.
Material and labour for rewinding of condensor fan motor of package type AC capacity 22 TR with super enameled copper conductor including replacement of worn out bushes ,shaft and capacitor etc and testing complete all as specified and as directed.
Supply and fix in repair of contactor CE certified for 5 HP motor starter 415 V, 50 Hz capacity for blower motor of AC plant of capacity 22 TR complete all as directed by Engineer-in-Charge.
Supply and fix in repair of contactor CE certified for 11 TR compressor 415 V, 50 Hz capacity for AC plant complete all as directed by Engineer-in-Charge.
Material and labour for rewinding of Desert Cooler fan motor 3 speed,1400 RPM any make of cap. 1/5 HP with super enameled copper wire of appropriate size incl. replacement of bush, shaft and oil filled capacitor 4 MFD, 240 volts complete all as specified and directed.
Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etc complete all as specified and directed.
Supply & Fix in repairs for replacement of following parts for Desert Cooler complete all as specified and directed.
Fan motor cap three speed,1400 RPM single phase with stand complete all as specified and directed.
Submersible pump for Desert cooler of existing make.
Wood/ wool chips pad for Desert Cooler (set of three pads)
Supporting jali of wood/ wool chips pad set made out of hard MS wire and fitted in side louvers. (set of three pads)
Name plate of front grill (as per sample kept in AGE E/M office).
Desert Cooler body with tank, slide panel, front grill etc complete
PVC water distributor of 3 outlets with MS nuts & bolts
PVC elbow suitable for desert cooler (as per sample)
PVC pipe 15 mm dia heavy duty for Desert Cooler Pump
3 pin plug top cap 5 Amp AC 240 Volts 50 Hz Make :Anchor/Cona/Havells
Motor fixing ring for desert cooler eight screw / clip type (as per sample kept in AGE E/M office)
Capacitor 4 mfd 240 Volt
Fan blade suitable for fan motor 1400 RPM capacity
S&F in repair of single phase input 180 to 250 Volts out put voltage stabilizer 230V complete and testing on completion of 5 KVA capacity complete all as specified and directed.
M &L in repair of replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/ 0.0076 cross sectional area superior quality complete all as specified and directed.
M &L for 50mm thick TF quality thermocole insulation with hot bitumen and cement plastic for external duct complete all as specified and directed.
M/s SK Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .